• Title/Summary/Keyword: VI

Search Result 2,261, Processing Time 0.03 seconds

Fate and Transport of Cr(VI) Contaminated Groundwater from the Industrial Area in Daejeon (대전 산업단지 지하수의 6가 크롬 오염 및 확산 평가)

  • Chon, Chul-Min;Moon, Sang-Ho;Ahn, Joo-Sung;Kim, Yung-Sik;Won, Jong-Ho;Ahn, Kyoung-Hwan
    • Economic and Environmental Geology
    • /
    • v.40 no.4
    • /
    • pp.403-418
    • /
    • 2007
  • The objective of this research was to characterize the fate and transport of Cr(VI) contaminated groundwater in the Daejeon industrial area. Five subsidiary monitoring wells were newly installed and two existing wells were utilized for the investigation and the reduction process of Cr(VI) contaminated groundwater of the Daejeon(Mun-pyeong) national groundwater monitoring station. The Cr(VI) concentrations at the shallow aquifer well of the station were in the range of 3.2-4.5 mg/L indicating continuous contamination. However, Cr was not detected at the deep bedrock well and the other monitoring wells except MPH-1 and 3. The Cr(VI) concentrations of MPH-1 and MPH-3 were below the drinking water guideline value (0.05 mg/L). Therefore, the plume of the Cr(VI) contaminated groundwater was predicted to be confined within the narrow boundary around the station. The soluble/exchangeable Cr(VI) concentrations were below the detection limit in all core and slime samples taken from the five newly installed wells. Although the exact source of contamination was not directly detected in the study area, the spatial Cr(VI) distribution in groundwater and characteristics of the core samples indicated that the source and the dispersion range were confined within the 100 m area from the monitoring station. The contamination might be induced from the unlined landfill of industrial wastes which was observed during the installation of an subsidiary monitoring well. For the evaluation of the natural attenuation of Cr(VI), available reduction capacities of Cr(VI) with an initial concentration of 5 mg/L were measured in soil and aquifer materials. Dark-gray clay layer samples have high capacities of Cr(VI) reduction ranging from 58 to 64%, which is obviously related to organic carbon contents of the samples. The analysis of reduction capacities implied that the soil and aquifer materials controlled the dispersion of Cr(VI) contamination in this area. However, some possibilities of dispersion by the preferential flow cannot be excluded due to the limited numbers of monitoring wells. We suggest the removal of Cr(VI) contaminated groundwater by periodical pumping, and the continuous groundwater quality monitoring for evaluation of the Cr(VI) dispersion should be followed in the study area.

Spectroscopic Studies on U(VI) Complex with 2,6-Dihydroxybenzoic acid as a Model Ligand of Humic Acid (분광학을 이용한 흄산의 모델 리간드인 2,6-Dihydroxybenzoic acid와 우라늄(VI)의 착물형성 반응에 관한 연구)

  • Cha, Wan-Sik;Cho, Hye-Ryun;Jung, Euo-Chang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.4
    • /
    • pp.207-217
    • /
    • 2011
  • In this study the complex formation reactions between uranium(VI) and 2,6-dihydroxybenzoate (DHB) as a model ligand of humic acid were investigated by using UV-Vis spectrophotometry and time-resolved laser-induced fluorescence spectroscopy (TRLFS). The analysis of the spectrophotometric data, i.e., absorbance changes at the characteristic charge-transfer bands of the U(VI)-DHB complex, indicates that both 1:1 and 1:2 (U(VI):DHB) complexes occur as a result of dual equilibria and their distribution varies in a pH-dependent manner. The stepwise stability constants determined (log $K_1$ and log $K_2$) are $12.4{\pm}0.1$ and $11.4{\pm}0.1$. Further, the TRLFS study shows that DHB plays a role as a fluorescence quencher of U(VI) species. The presence of both a dynamic and static quenching process was identified for all U(VI) species examined, i.e., ${UO_2}^{2+}$, $(UO_2)_2{(OH)_2}^{2+}$, and $(UO_2)_3{(OH)_5}^+$. The fluorescence intensity and lifetimes of each species were measured from the time-resolved spectra at various ligand concentrations, and then analyzed based on Stern-Volmer equations. The static quenching constants (log $K_s$) obtained are $4.2{\pm}0.1$, $4.3{\pm}0.1$, and $4.34{\pm}0.08$ for ${UO_2}^{2+}$, $(UO_2)_2{(OH)_2}^{2+}$, and $(UO_2)_3{(OH)_5}^+$, respectively. The results of Stern-Volmer analysis suggest that both mono- and bi-dentate U(VI)-DHB complexes serve as groundstate complexes inducing static quenching.

Studies on the Selective Separation and Preconcentration of Cr(VI) Ion by XAD-16-Chromotropic Acid Chelating Resin (XAD-16-Chromotropic Acid 킬레이트 수지에 의한 몇 가지 금속이온의 선택적 분리 및 농축에 관한 연구)

  • Lee, Won;Lee, Chang-Youl;Kim, Mi-Kyoung;Kim, In-Whan
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.199-210
    • /
    • 2004
  • A new polystyrene-divinylbenzene chelating resin containing 4,5-dihydroxy-naphthalene-2,7-disulfonic acid (chromotropic acid : CTA) as functional group has been synthesized and characterized. The sorption and desorption properties of this chelating resin for Cr(III) ion and Cr(VI) ion including nine metal bloodstain. As a results, FOB test kit could be effectively applied to identification of human blood at chelating resin was stable in acidic and alkaline solution. The Cr(VI) ion is selectively separated from Cr (III) ion at pH 2 and the maximum sorption capacity of Cr(VI) ion is 1.2 mmol/g. In the presence of anions such as $F^-$, $SO{_4}^{2-}$, $CN^-$, $CH_3COO^-$, $NO{_3}^-$, the sorption of Cr(VI) ion was reduced but anions such as $PO{_4}^{3-}$ and $Cl^-$ revealed no interference effect. The elution order of metal ions obtained from breakthrough capacity and overall capacity at pH 2 was Cr(VI)>Sn(II)>Fe(III)>Cu(II)>Cd(II)${\simeq}Pb(II){\simeq}Cr(III){\simeq}Mn(II){\simeq}Ni(II){\simeq}Al(III)$. Desorption characteristics for Cr(VI) ion was investigated with desorption agents such as $HNO_3$, HCl, and $H_2SO_4$. It was found that the ion showed high desorption efficiency with 3 M HCl. As the result, the chelating resin, XAD-16-CTA was successfully applied to separation and preconcentration of Cr (VI) ion from several metal ions in metal finishing works.

Application of Reused Powdered Waste Containing Aluminum Oxide on the Treatment of Cr(VI) (6가 크롬 처리를 위한 알루미늄 산화물을 함유한 재생 분말 폐기물의 적용)

  • Lim, Jae-Woo;Kim, Tae-Hwan;Kang, Hyung-Sik;Kim, Do-Son;Kim, Han-Seon;Cho, Seok-Hee;Yang, Jae-Kyu;Chang, Yoon-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.3
    • /
    • pp.179-185
    • /
    • 2009
  • In this research, the removal capacity of Cr(VI) by the reused powdered wastes (RPW) containing aluminium oxides was studied. As a pre-treatment process for the preparation of calcined wastes, calcination was conducted at $550^{\circ}C$ to remove organic fraction in the raw wastes. In order to study the adsorption trend of Cr(VI) ions from aqueous solutions, the pH-edge adsorption, adsorption kinetic and adsorption isotherm were investigated using a batch reactor in the presence of four different background electrolytes($NO_3\;^-,\;CO_3\;^{2-},\;SO_4\;^{2-},\;PO_4\;^{3-}$). Cr(VI) adsorption was greatly reduced in the presence of $SO_4\;^{2-}$ and $PO_4\;^{3-}$ over the entire pH range. Meanwhile the inhibition effect by $NO_3\;^-$ and $CO_3\;^{2-}$ was relatively lower than that by $SO_4\;^{2-}$ and $PO_4\;^{3-}$. Cr(VI) adsorption was maximum around pH 4.5 in the presence of $NO_3\;^-$ and $CO_3\;^{2-}$. As the concentration of background electrolytes increased, Cr(VI) adsorption decreased. This result mightly suggests that adsorption between the surface of RPW and Cr(VI) occurs through outer-sphere complex. Cr(VI) adsorption onto the RPW was well described by second-order kinetics. From the Langmuir isotherm at initial pH 3, the maximum adsorbed amount of Cr(VI) onto the RPW was 11.1, 10, 3.3, 5 mg/g in the presence of $NO_3\;^-,\;CO_3\;^{2-},\;SO_4\;^{2-}$, and $PO_4\;^{3-}$, respectively.

Primary Skin and Eye Irritation Study of Combined Vaccine (KGCC-95VI) Against Japanese Encephalitis and Hantaan Virus Infection

  • Shin, Kwang-Soon;Kim, Chul-Joong;Yun, Hyo-In;Park, Jong-Il;Cha, Shin-Woo;Shin, Hyeong-Soon
    • Toxicological Research
    • /
    • v.13 no.1_2
    • /
    • pp.157-160
    • /
    • 1997
  • The primary skin and eye irritancy of the combined vaccine (KGCC-95VI) for the prophylaxis against Japanese encephalitis and Hantaan virus infection recently developed by Korea Green Cross Corporation was investigated. The KGCC-95VI was applied to the back skins of the New Zealand White rabbits. The rabbits were observed for 72 hours and did not exhibit erythema, eschar and edema. The eyes of the rabbits were exposed to the KGCC-95VI. The rabbits were observed for 7 days and did not exhibit any ocular findings on cornea, iris and conjuntivae. The KGCC-95VI is considered not to have the primary skin and eye toxicity in rabbits.

  • PDF

Novel Method for Stripping of Molybdenum(VI) after Its Extraction with Cyanex 301

  • Saberyan, Kamal;Maragheh, Mohammad Ghannadi;Ganjali, Mohammad Reza
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.460-465
    • /
    • 2004
  • Hydrofluoric acid has been used as a novel stripping agent for molybdenum(VI) after its extraction with Cyanex 301. In the extraction step, the effects of parameters such as type and initial concentration of acid, type of diluent, extractant concentration, metal concentration and temperature have been studied. In the stripping step, the effects of various stripping agents on stripping efficiency have been investigated. Hydrofluoric acid has been chosen as an effective stripping agent, and the effects of concentration of hydrofluoric acid, stripping time, volume of hydrofluoric acid and the number of stages of stripping have been studied. Molybdenum(VI) has been effectively separated from a large number of elements in binary mixtures, with a very high tolerance limit. Finally, the optimized method has been extended for the analysis of Mo(VI) in spent molybdenum catalysts.

Reduction Kinetics of Hexavalent Chromium during Biosorption onto the Protonated Ecklonia Biomass

  • Park, Dong-Hui;Yun, Yeong-Sang;Park, Jeong-Jin;Kim, Sang-Min;Park, Jong-Mun
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.113-116
    • /
    • 2000
  • Hexavalent chromium was removed by means of biosorption onto the protonated brown seaweed biomass. During the biosorption Cr(VI) was reduced to Cr(III), which resulted in accumulation of Cr(III) in the solution. The Cr(VI) reduction rate increased with increases of initial Cr(VI) and biosorbent concentrations and decrease of solution pH. Based upon the experimental results at various conditions, we suggested the mechanism for the chromium removal as following serial reactions: (1) sorption of anionic Cr(VI) onto the positively charged site of biomass, (2) reduction of Cr(VI) to Cr(III) on the positively charged site, (3) desorption of Cr(III) from the positively charged site, and (4) sorption of cationic Cr(III) onto the negatively charged site of biomass.

  • PDF

Development of On-Site Process for Refractory 2,4-Dichlorophenol Treatment (난분해성 2,4-Dichlorophenol 처리를 위한 원위치 처리 프로세스 개발 연구)

  • Park, Kyeong-Deok;Kim, Il-Kyu
    • Journal of Power System Engineering
    • /
    • v.20 no.1
    • /
    • pp.42-49
    • /
    • 2016
  • This study showed that on-site ferrate(VI) solution was synthesized by wet oxidation method and applied aqueous 2,4-dichlorophenol(DCP) solution to evaluate the degradation efficiency. On-site ferrate(VI) solution was synthesized by putting $FeCl_3{\cdot}6H_2O$ in the strong alkali solution with NaClO and NaOH and applied DCP solution directly. DCP solution was extracted by the liquid-liquid method and analyzed by GC-ECD. The factors such as pH, DCP initial concentration, injected ferrate(VI) dosage, temperature were investigated. The optimum pH and temperature conditions of DCP degradation were obtained in neutral condition and $35^{\circ}C$. And the experimental results showed that DCP removal efficiency also increased with the decrease of DCP initial condition and the injected ferrate(VI) dosage.

Accretion Flow and Disparate Profiles of Raman Scattered O $VI{\lambda}{\lambda}1032$ and 1038 in the Symbiotic Star V1016 Cygni

  • Heo, Jeong-Eun;Lee, Hee-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.88.2-88.2
    • /
    • 2014
  • The symbiotic star V1016 Cygni shows the Raman scattered O VI features at $6825{\AA}$ and $7088{\AA}$. These are formed through inelastic scattering of O VI 1032, 1038 by atomic hydrogen. They exhibit characteristic double peak profiles with a stronger red peak, which is explained by the accretion flow around the white dwarf. In addition, the two Raman features have different profiles in such a way that the blue part of the Raman 7088 feature is relatively more suppressed than the Raman 6825 counterpart. We produced the Doppler maps of the two Raman features in order to trace the origin of the disparate profiles. We conclude that the profile difference is due to various O VI 1032 to O VI 1038 flux ratios in the accretion region. This is consistent with the picture where the slow stellar wind from the giant interacts with the accretion flow around the white dwarf.

  • PDF