• 제목/요약/키워드: VHF-UHF Antenna

검색결과 26건 처리시간 0.03초

부분방전 측정용 UHF센서의 설계 (A Design of UHF Sensor using Partial Discharge Measurement in GIS)

  • 박경수;김정배;송원표;김덕수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.28-30
    • /
    • 2002
  • The PD in GIS leads to a charge transfer and a voltage drop across the discharge area. They cannot be measure directly but we can measure electromagnetic wave made by PD. In generally, compared with VHF band, electromagnetic waves of UHF band have a low noise therefore, we can detect the real defect with several pC in GIS using UHF method. In this paper, the U-slot microstrip patch antenna for measuring PD signal in GIS is presented. the proposed UHF sensor are designed to have large band characteristics and unaffected structure for GIS operation.

  • PDF

가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법 (UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear)

  • 송원표;김정배;김민수;정재룡;박승재;고희석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.414-420
    • /
    • 2005
  • A method for partial discharge diagnosis based on UHF narrow band type for GIS has been developed and calibrated. In generally, PD cannot be directly measured under on-line condition, but we can indirectly measure the electromagnetic wave made by PD using the high-frequency antenna. Compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise in high-voltage substation. Therefore, we can detect the real abnormality with several pC in GIS using UHF narrow-band type method. For the case of no internal VHF sensor for GIS of the domestic substation, it has applied to use the external UHF sensor attached in spacer in GIS of existing substation. In this paper, we firstly described the technique of partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity test, the relationship of dBm-pC and diagnosis result of the cause of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on the real GIS in domestic substation. These results make above method applicable for measurement of quantity and cause of PD for real operation GIS in high-voltage substation.

HEMP 상황 하 전술기동무선통신체계 안테나 유도전압 측정 및 분석 (Measurement and Analysis of Antenna Induced Voltage for Tactical Mobile Wireless Communication System under HEMP Environment)

  • 박경제;정길수;김정섭;박용우;박재현
    • 한국시뮬레이션학회논문지
    • /
    • 제30권2호
    • /
    • pp.33-40
    • /
    • 2021
  • 고고도 전자기 펄스(HEMP)의 상황은 고고도 핵폭발로 인해 발생한다. HEMP상황은 위협 레벨 조사(TLI)를 통해 HEMP 상황을 시뮬레이션 할 수 있다. 본 논문에서는 전술기동무선통신체계의 안테나 종류에 따른 유도 전압을 위협 레벨 조사로 측정 및 분석 하였다. HEMP의 영향을 받으면 전자 장비가 마비되거나 손상 될 수 있다. HEMP 방호 필터는 전원선 및 신호선용으로 상용화되어 있다. 그러나 안테나용 HEMP 필터는 상용화가 부족한 편이며 존재하더라도 낙뢰보호용으로 제작되어 있다. 안테나의 주파수와 종류에 따라 적절한 HEMP 방호 필터를 만들기 위해 유도 전압을 측정하고 외삽법을 통해 최대 유도 전압을 분석하였다. 측정 결과 HF, VHF, UHF 대역과 같이 주파수가 증가할수록 측정된 유도전압은 감소하는 것으로 나타났다.

수분측정장치용 인덕턴스 부하 소형 개루우프 진행파 안테나의 특성 해석 (Analysis of inductance loaded small type open-loop travelling wave antenna for moisture mesurement systems)

  • 정주수;주창복
    • 전자공학회논문지A
    • /
    • 제33A권7호
    • /
    • pp.111-120
    • /
    • 1996
  • In this paper, we proposed an inductance loaded small type open-loop travelling wave antenna model for the suitable VHF/UHF frequency bands moisture measurement systems and analyzed its operating characteristics by galerkin's solution method. This antenna model enables to change the oeprating rsonance frequency from the frequency range 150 Mhz to 1.0 Ghz without changing the antenna design dimensions by only varing the load inductance values and it showed the similar operating charcteristics and narrowband resonance characteristics at each resonance frequencies. Also this model showed the uniformly distriubte dpower radiation characteristics above the loop axis and it can effectively suppress the spurious radiations from its narrowband resonance characteristics.

  • PDF

큐브위성 송수신시험을 위한 실내용 지상국 구축 (Construction of Indoor Ground Station for Cubesat Communication Test)

  • 한상혁;문상만;신동엽;문성태;공현철;최기혁
    • 항공우주기술
    • /
    • 제13권2호
    • /
    • pp.73-79
    • /
    • 2014
  • 큐브위성 비행 소프트웨어 개발과정에서 큐브위성과 지상국간 데이터 송수신 시험이 필요한데 지상국 구축 비용과 공간성 등을 고려해 야외용 안테나를 사용하지 않는 실내용 지상국이 적합하다. 실내용 지상국 구축시 송신 출력이 높으면 큐브위성 통신시스템의 고장을 유발할 수 있음으로 지상국의 송신 출력이 큐브위성 통신시스템의 수신 허용범위 안에 있도록 설계하고, 이를 검증해야 한다. 본 논문에서는 UHF 및 VHF 주파수를 사용하는 큐브위성과의 데이터 송수신을 위한 실내용 지상국 구축에 대해 기술한다. 특히, 송신 출력을 저감하기 위한 방법으로 감쇄기를 사용하였는데, 송신단에 감쇄기를 연결하여 송신 출력과 감쇄기 수에 따른 감쇄 정도를 측정하고 이의 결과를 분석하여 기술하였다.

3d-PD 패턴과 VHF/UHF PD 신호의 고찰 (The Analysis of VHF/UHF PD and 3d-PD Pattern)

  • 임장섭;박용석;최병하;한석균
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 반도체재료
    • /
    • pp.75-78
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

모의 변압기의 VHF/UHF PD 스펙트럼 분석 (Spectrum Analysis of VHF/UHF PD in Simulated Transformer)

  • 김덕근;김종서;임용배;임장섭;문채주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.50-54
    • /
    • 2000
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

8-VSB DTTB의 최적 ERP와 안데나 HAAT에 관한 연구 (A Study on optimal ERP and HAAT of antenna for the 8-VSB DTTB)

  • 김선미;박근희;류광진;김영곤;노순국;박창균
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(1)
    • /
    • pp.365-368
    • /
    • 2001
  • 현재 운용중인 NTSC송신시스템을 근거로 가까운 장래에 설치되어 운용될 8-VSD DTV전송시스템의 재원을 설계한다. 먼저 아나로그 NTSC와 디지털 8-VSH DTV의 지상파 방송의 경우 최적의 수신전계를 유지할 수 있는 조건을 검토하고, Longley-Rice의 전계강도 산출법을 이용해서 수신을 위한 최소한의 전계강도의 임계값을 산출한다 8-VSH DTV전송은 NTSC 6MHz대역에서 HDTV가 가능하도록 19.39Mbps의 데이타를 고속으로 전송하는데 그 목표fmf 두고 있으므로 무엇보다 송 · 수신점 사이의 전계강도의 최적화는 중요한 문제이므로 8-VSB DTV전송은 NTSC 서비스 커버리지에 비하여 확장되거나 효율적이어야만 한다. 본 연구에서는 산출결과 NTSC가 8-VSH DTV와 동일한 서비스 커버리지를 유지하기 위하여 NTSC VHF에서 DTV UHF로 전환시 필요한 송신출력과 NTSC UHF에서 DTV UHF로의 전환시 필요한 송신출력을 산출한다.

  • PDF

엔틀러 터미널 환경에서 실험적인 패스 로스 모델에 관한 연구 (The Study on Empirical Propagation Path Loss Model in the Antler Terminal Environment)

  • 김경태;김진욱;조윤현;김상욱;윤인섭;박효달
    • 한국항행학회논문지
    • /
    • 제17권5호
    • /
    • pp.516-523
    • /
    • 2013
  • 본 논문에서는 엔틀러 구조를 가진 인천공항 터미널 지역에서 항공정보통신 무선 채널의 패스 로스 모델에 관해 연구하였다. 항공정보통신 주파수 밴드인 VHF/UHF 채널 중에 두 개의 주파수에 대해 전파 측정을 수행하였다. 현재 운영 중인 송신 사이트에서 변조 신호를 제거한 캐리워 파워를 송신하였으며, 전파 측정을 위해 수신기를 장착한 이동 차량을 이용하여 여객터미널 지역에서 전파 측정을 수행하였다. 송신 파워, 주파수, 안테나 위치 등은 현재 운용 조건과 같다. 패스 로스 계수 및 실험적인 패스 로스식은 기본적인 패스 로스 모델 및 하타 모델등을 이용하여 추출하였다. 엔트러 구조를 가진 터미널 지역에서 추출된 NLOS 패스 로스 계수는 128.2MHz 및 269.1MHz에서 각각 3.32 및 3.10이었고 예측 에러의 편차는 각각 9.69 및 9.65 이었다. 추출된 패스 로스 계수를 이용하여 여객터미널 지역에서 전파 패스 로스 식을 실험적인 패스 로스 계수을 도출하였으며 또한 다른 전파 패스 모델과 비교하였다. 이러한 결과는 항공정보통신 사이트 최적 위치 선정 및 항공정보통신 서비스 평가에 도움이 될 것이다.

CW 레이다와 자계기술을 복합한 새로운 차량검지기 개발 (Development of a New Vehicle Detector Combining CW Radar and Magnetometer Techniques)

  • 정재영;김인석
    • 한국전자파학회논문지
    • /
    • 제10권4호
    • /
    • pp.564-581
    • /
    • 1999
  • 본 논문에서는 CW 레이다기술, 자계기술, VHF/UHF 안테나를 사용한 적은 비용으로 작고 튼튼하며, 신속한 교체가 가능한 도로 관입형 차량검지기를 소개한다. 기존의 교통정보시스템의 알고리즘을 변화시키지 않고, 모든 환경조건에서 보다 정확히 동착하며 널리 사용되고 있는 루프감지기를 대체할 수 있도록 개발되 어졌다 검지된 차량정보는 물리적으로 강한 유전물질에 삽입된 소형의 헬리컬안테나에서 송출하여 5/8 파장 의 GP 안테나로 받아 제어부로 전송한다. 청명한 날씨에는 24 GHz로 동작하나 많은 비가 올 때는 자동스위치에 의해 자계검지부가 동작한다.

  • PDF