• Title/Summary/Keyword: VAC

Search Result 225, Processing Time 0.038 seconds

A Study of Heterogeneity Corrections for Radiation Treatment Planning (방사선 치료계획 시 불균질 보정에 관한 고찰)

  • Lee, Je-Hee;Kim, Bo-Gyum;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.89-96
    • /
    • 2006
  • Purpose: To study effectiveness of heterogeneity correction of internal-body inhomogeneities and patient positioning immobilizers in dose calculation, using images obtained from CT-Simulator. Materials and Methods: A water phantom($250{\times}250{\times}250mm^3$) was fabricated and, to simulate various inhomogeneity, 1) bone 2) metal 3) contrast media 4) immobilization devices(Head holder/pillow/Vac-lok) were inserted in it. And then, CT scans were peformed. The CT-images were input to Radiation Treatment Planning System(RTPS) and the MUs, to give 100 cGy at 10 cm depth with isocentric standard setup(Field Size=$10{\times}10cm^2$, SAD=100 cm), were calculated for various energies(4, 6, 10 MV X-ray). The calculated MUs based on various CT-images of inhomogeneities were compared and analyzed. Results: Heterogeneity correction factors were compared for different materials. The correction factors were $2.7{\sim}5.3%$ for bone, $2.7{\sim}3.8%$ for metal materials, $0.9{\sim}2.3%$ for contrast media, $0.9{\sim}2.3%$ for Head-holder, $3.5{\sim}6.9%$ for Head holder+pillow, and $0.9{\sim}1.5%$ for Vac-lok. Conclusion: It is revealed that the heterogeneity correction factor calculated from internal-body inhomogeneities have various values and have no consistency. and with increasing number of beam ports, the differences can be reduced to under 1%, so, it can be disregarded. On the other hand, heterogeneity correction from immobilizers must be regarded enough to minimize inaccuracy of dose calculation.

  • PDF

Nonlinear Dielectric Properties of Amorphous copolymers (무정형 고분자 재료의 비선형 유전특성)

  • Roh, Il-Soo;Hwang, Jung-Youn;Kang, Dae-Ha;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1563-1565
    • /
    • 1999
  • Linear and nonliear complex permittivities have been measured for amorphous copolymers of vinylidene cyanide (VDCN) with vinyl acetate (VAc), vinyl propionate (VPr), vinyl benzoate (VBz), styrene (St) and methyl methacrylate (MMA). It is found that the third order permittivity ${\varepsilon}_3$ depends upon frequency according to a function ${\Delta}_{{\varepsilon}_3}/(1+i{\omega}{\tau}_^3)$ while the linear permittivity obeys a Debye function ${\Delta}_{{\varepsilon}_1}/(1+i{\omega}{\tau}_1)$. Experimental results are well fitted by the above predicted functions except at low frequencies where dc conduction dominates. The ${\tau}_1$ and ${\tau}_3$ are nearly equal, and depend upon temperature according to a WLF form. The relaxation strength ${\Delta}_{{\varepsilon}_1}$ depends upon comonomers ranging from $130_{{\varepsilon}_0}$(VAc) to $20{{\varepsilon}_0}$(MMA). The ${\Delta}_{{\varepsilon}_3}$ is negative and depends more strongly upon comonomers. Combined knowledge about linear and nonlinear permittivities predicts very large correlation factors which indicates strongly cooperative dipolar motions in those amorphous copolymers.

  • PDF

Simulation of Vacuum Characteristics by Applications of Vacuum Valves in Display Processing (디스플레이공정 진공시스템 밸브응용에 따른 진공특성 전산모사)

  • Kim, Hyung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.77-83
    • /
    • 2012
  • Effect of valve conductance on performance of vacuum system was simulated for optimum design of vacuum system. In this investigation, the feasibility of modeling mechanism for VacSimMulti simulator was proposed. Application specific design of vacuum system is required to meet the particular process conditions for various industrial implementations of vacuum equipments. Geometry and length, diameter of vacuum valve were modeled as simulation modeling variables for conductance effects. Series vacuum system was modeled and simulated with varied dimensions and structures of exhaust valves. Variation of valve diameter showed the more significant effects on vacuum characteristics than that of pipeline length variations. It was also observed that the aperture structure of valve had the superior vacuum characteristics among the modeled systems.

Studies on the Effective Drug Delivery System Using Naked Plasmid DNA for the Erythropoietin Expression in vivo

  • Park, Yeong-Seop;Jeong, Dong-Geon;An, Jin-Ho;Choe, Cha-Yong;Ju, Hyeon
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.582-586
    • /
    • 2003
  • There has been interest in developing gene therapy based on naked plasmid DNA for treating serum protein deficiencies and human erythropoietin (hEPO) is one of the candidate for gene therapy being Investigated most enthusiastically. We constructed novel plasmid DNA vectors pVAC-hEPOI/II/III which contain one, two, three hEPO gene(s) respectively for producing high level expression and secretion of hEPO in vitro and in vivo. NIH3T3 and COS7 cells were transfected transiently with these vectors and increase in hEPO expression in medium reached 2-5 fold in comparison with pSecTagB-hEPO. Intra muscular administrations of pVAC-hEPOI/II/III vectors into mice resulted in high level secretion of hEPO in the serum and corresponding increases in hematocrit level. In conclusion the transduction efficiency of naked plasmid vectors is one of the critical factors of a gene delivery system and these novel plasmid vectors will contribute to various gene therapy based on naked plasmid DNA.

  • PDF

Removal of Odor- containing Sulfur Compound, Methyl Mercaptan using Modified Activated Carbon with Various Acidic Chemicals (산으로 개질된 활성탄을 이용한 메틸 메르캅탄 악취물질 제거)

  • Kim Dae Jung;Seo Seong Gyu;Kim Sang Chai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.155-160
    • /
    • 2005
  • Removal of methyl mercaptan was investigated using adsorption on virgin activated carbon (VAC) and modified activated carbons with acidic chemicals in the present work. CAC, NAC, AAC and SAC were represented as activated carbons modified with HCI, HNO$_{3}$, CH$_{3}$COOH and H$_{2}$S0$_{4}$ ,respectively The pore structures were evaluated using nitrogen isotherm. The surface properties of virgin activated carbon and modified activated carbons were characterized by EA, pH of carbon surface and acid value from Boehm titration. The modification of activated carbon with acidic chemicals resulted in a decrease in BET surface area, micropore volume and surface pH, but an increase in acid value. The order of the adsorption capacity of activated carbons was NAC>AAC>SAC>CAC>VAC, and in agreement with that of acid value of activated carbons, whereas in disagreement with that of micropore volume of activated carbons. It appeared that chemical adsorption played an important role in methyl mercaptan on modified activated carbons with acidic chemicals compared to virgin activated carbon. Modifying activated carbon with acidic chemicals enabled to significantly enhance removal of methyl mercaptan.

Retroperitoneal Gauze Packing with Vacuum-Associated Closure for Pelvic Fracture with Hemodynamic Instability (혈역학적으로 불안정한 골반 골절에서 진공 폐쇄 드레싱을 병용한 후복막 거즈 충전법 치료)

  • Kim, Sung Jeep;Kim, Ji Hoon T.
    • Journal of Trauma and Injury
    • /
    • v.27 no.2
    • /
    • pp.29-32
    • /
    • 2014
  • Pelvic bone fracture with hemodynamic instability is fatal and the mortality rate can range up to 40%. Despite the big advances in the treatment of massive bleeding and hemorrhagic shock, the mortality associated with hemodynamically unstable pelvic bone fractures remains high. The gold standard of treatment for pelvic bone fracture with hemodynamic instability has not yet been determined and is an issue of main discussion among many doctors. Retroperitoneal packing is not yet wide spread in Korea, but is a good modality for managing of massive bleeding from pelvic bone fractures when an angiography suite or an expert surgeon is not available. A vacuum-assisted closure (VAC) system can also be applied with retroperitoneal packing in the manner of damage control surgery and open abdomen surgery. We present the case of a 51-year-old male who had a pelvic bone fracture with massive bleeding. We performed retroperitoneal gauze packing with a VAC system for the first time. The postoperative vital signs of patient were immediately stable, the massive bleeding was easily and quickly controlled, and the amount of transfusion of blood components was reduced.

Vibrational Characteristics of Magnetostrictive Materials for a Vibration Assisted Cutting Device (진동절삭기 구성을 위한 자기변형 재료의 진동 특성 규명)

  • Lee, Ho-Cheol;Kim, Gi-Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1214-1220
    • /
    • 2012
  • Vibration assisted cutting (VAC) is one of the promising methods for precision machining, which has been normally equipped with piezoelectric materials. In this paper, a feasibility of applying magnetostrictive materials to VAC as a cutting device instead of piezoelectric materials was studied. For this, the vibrational characteristics of a magnetostrictive material was investigated with respect to a coil design, a preload, and the effects of a biasing and an exciting magnetic fields. The output strain of a magnetostrictive material is restricted due to an increasing inductive impedance as the exciting frequency increases and the heat of coil, etc. Through the experimental results, it was found that the biasing and the exciting magnetic field affected the output performance significantly but not the preload. In conclusion, the magnetostrictive material could be used only in the low frequency range but not a good candidate for high frequency actuating application.

A Study on Variable Speed Generation System with Energy Saving Function

  • Dugarjav, Bayasgalan;Lee, Sang-Ho;Han, Dong-Hwa;Lee, Young-Jin;Choe, Gyu-Ha
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.137-143
    • /
    • 2013
  • This paper presents development of variable speed generation (VSG) system with energy saving function. The rubber tyred gantry crane (RTGC) requires the power from diesel-engine. Significant fuel savings by reducing the engine speed can be achieved, because all of operation modes except hoisting are required lower power than rated value of engine. When low speed operation output voltage of generator is decrease until acceptable range of motor driver inverters and auxiliary load supplier. According to power demand engine speed is varying from 20 to 60Hz, and voltage is varying between 210Vac and 480Vac. When idle mode or low power operation dc/dc converter operates by constant output voltage control and inverters dc site voltage is compensated by it. This paper proposed 3-phase interleaved boost converter which has the same structure as the commercially available 3-phase inverter and current sharing capability. 400kW interleaved converter is designed and a performance of converter is evaluated through several experiments with a RTGC system. Energy saving VSG system can cut down fuel consumption by 36% and 21.3% at idle and unidirectional load operations.