• Title/Summary/Keyword: V4

Search Result 19,629, Processing Time 0.047 seconds

Effects of Wollastonite Coating on Surface Characteristics of Plasma Electrolytic Oxidized Ti-6Al-4V Alloy (플라즈마 전해 산화처리된 Ti-6Al-4V합금의 표면특성에 미치는 울라스토나이트 코팅효과)

  • Jaeeun Go;Jong Kook Lee;Han Cheol Choe
    • Corrosion Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.257-264
    • /
    • 2023
  • Ti-6Al-4V alloys are mainly used as dental materials due to their excellent biocompatibility, corrosion resistance, and chemical stability. However, they have a low bioactivity with bioinertness in the body. Therefore, they could not directly bond with human bone. To improve their applications, their bone bonding ability and bone formation capacity should be improved. Thus, the objective of this study was to improve the bioinert surface of titanium alloy substrate to show bioactive characteristics by performing surface modification using wollastonite powder. Commercial bioactive wollastonite powder was successfully deposited onto Ti-6Al-4V alloy using a room temperature spray process. It was found that wollastonite-coated layer showed homogeneous microstructure and uniform thickness. Corrosion resistance of Ti-6Al-4V alloy was also improved by plasma electrolytic oxidation treatment. Its wettability and bioactivity were also greatly increased by wollastonite coating. Results of this study indicate that both plasma electrolytic oxidation treatment and wollastonite coating by room temperature spray process could be used to improve surface bioactivity of Ti-6Al-4V alloy substrate.

Synthesis and Photovoltaic Properties of New π-conjugated Polymers Based on Benzo[1,2,5]thiadiazole (Benzo[1,2,5]thiadiazole을 기본 골격으로 한 공액고분자의 합성 및 광전변환특성 연구)

  • Bea, Jun Huei;Lim, Gyeong Eun;Kim, Joo Hyun
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.396-401
    • /
    • 2013
  • Alternating copolymers, poly[9-(2-octyl-dodecyl)-9H-carbazole-alt-4,7-di-thiophen-2-yl-benzo[1,2,5]thiadiazole] (PCD20TBT) and poly[9,10-bis-(2-octyl-dodecyloxy)-phenanthrene-alt-4,7-di-thiophen-2-yl-benzo[1,2,5]thiadiazole] (PN40TBT), were synthesized by the Suzuki coupling reaction. The copolymers were soluble in common organic solvents such as chloroform, chlorobenzene, 1,2-dichlorobenzene, tetrahydrofuran and toluene. The maximum absorption wavelength and the band gap of PCD20TBT were 535 nm and 1.75 eV, respectively. The maximum absorption wavelength and the band gap of PN40TBT were 560 nm and 1.97 eV, respectively. The HOMO and the LUMO energy level of PCD20TBT were -5.11 eV and -3.36 eV, respectively. As for PN40TBT, the HOMO and the LUMO energy level of PCD20TBT were -5.31 eV and -3.34 eV, respectively. The polymer solar cells (PSCs) based on the blend of copolymer and PCBM (1 : 2 by weight ratio) were fabricated. The power conversion efficiencies of PSCs based on PCD20TBT and PN40TBT were 0.52% and 0.60%, respectively. The short circuit current density ($J_{SC}$), fill factor (FF) and open circuit voltage ($V_{OC}$) of the device with PCD20TBT were $-1.97mA/cm^2$, 38.2% and 0.69 V. For PN40TBT, the $J_{SC}$, FF, and $V_{OC}$ were $-1.77mA/cm^2$, 42.9%, and 0.79 V, respectively.

The Biocompatibility Of Cultured Bone Marrow Cells And Gingival Fibroblasts On The Titanium Surfaces (티타늄 배양에 대한 배양골수와 치은 섬유아세포의 생체적합성)

  • Oh, Choong-Young;Park, Joon-Bong;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.143-160
    • /
    • 1996
  • The purpose of this study was to evaluate the response in aspect of attachment and growth rate of osteoblasts and growth rate of osteoblasts and human gingival fibroblasts to the commercially pure titanium(CP titanium)and titanium alloy(Ti-6AI-4V) that are used widely as implant materials, and to obtain the basic information to ideal implant materials. In the studly, commercially pure titanium in first test group, titanium alloy(Ti-6AI-4V) in second test group, cobalt-chrome-molybdenum alloy(Co-Cr-Mo alloy) in positive control group, and tissue culture polystyrene plate in negative control group were used. The results of this study were as follows. 1. Bone marrow cells cultured on CP titanium and Ti-6Al-4V showed significantly greater attachment and growth rate(p(0.05) compared to Co-Cr-Mo alloy in each time. 2. There were no significant differences(p>0.05) in attachment and growth rate of bone marrow cells cultured on CP titanium and Ti-6AI-4V or tissue culture plate. 3. Most bone marrow cells cultured on CP titanium, Ti-6Al-4V and tissue culture plate were attached well to each substratum in first 2days, and then, grew at higher growth rate. On the other hand, some cells cultured on Co-Cr-Mo alloy failed to attach in first 2 days, and then, attached cells grew at lower growth rate than other groups. 4. Attachment and growth rates of gingival fibroblasts cultured on CP titanium and Ti-6Al-4V showed no significant differences(p>0.05) compared to Co-Cr-Mo alloy in 2 days, but significantly greater increase(p<0.05) in 5 and 9 days. 5. There were no significantly differences(p>0.05) between growth rates on gingival fibroblasts cultured on CP titanium, Ti-6Al-4V and tissue culture plate in 2 and 5days, but a significant lower growth rate(p<0.05) on CP titanium and Ti-6Al-4V versus tissue culture plate. 6. Some gingival fibroblasts cultured on all specimen groups failed to attach, but attached cells grew well, especially on CP titanium, Ti-GAl-4V and tissue culture plate. 7. There were no significant differences(P>0.05) between growth rates of both bone marrow cells and gingival fibroblasts cultured on CP titanium and Ti-6AI-4V. As a result of this study, both commercially pure titanium and Ti-6AI-4V showed excellent biocompatibility and there was no significant difference in the cellular response to the both metals. Bone marrow cells cultured on each substratum showed significantly greater growth rate and responded sensitively to cytotoxic effects of metal surfaces compared to gingival fibroblasts. Considering cell response to the substrate, it was likely that the composition itself of titanium metals have no significant effect on the biocompatibility. Further study need to be done to evaluate the influence of surface characteristics on cellular responses.

  • PDF

Effect of Nb, V and Cr on the High Temperature Oxidation of Ti-(42, 44)% Al Alloys (Ti-(42, 44)%Al 합금의 고온내산화성에 미치는 Nb, V 및 Cr의 영향)

  • Lee, Yeong-Chan;Kim, Mi-Hyeon;Kim, Seong-Hun;Lee, Won-Uk;Baek, Jong-Hyeon;Lee, Dong-Bok
    • Korean Journal of Materials Research
    • /
    • v.9 no.10
    • /
    • pp.1025-1031
    • /
    • 1999
  • Alloys of TiAl with six different compositions. i. e., Ti-(42, 44)Al-2Nb-4V. Ti-(42, 44)Al-4Nb-2V and Ti -(42, 44)Al-4Nb-2Cr, were manufactured by arc-melting. and their oxidation behavior was studied. Both isothermal and cyclic oxidation tests were performed at 700, 800 and $900^{\circ}C$ in air for 50hr. The oxidation resistance increased in the order of Ti-(42, 44)Al-2Nb-4V, Ti-(42, 44)Al-4Nb-ZV and Ti-(42, 44)Al-4Nb-2Cr. It was found that V was a deleterious element, while Cr was a beneficial element in terms of oxidation resistance. During oxidation, a simultaneous interdiffusion was observed. All the constituent elements in the base alloys diffused outward. whereas oxygen from the atmosphere diffused inward, to form triple oxide layers composed of an outermost $\textrm{TiO}_2$ layer. upper ($\textrm{TiO}_2+\textrm{Al}_2\textrm{O}_3$) mixed layer, and lower $\textrm{TiO}_2$-rich layer.

  • PDF

Magnetic Properties of ${\alpha}-Fe$ Based Nd-Fe-B Melt-Spun Alloys (${\alpha}-Fe$ 기 Nd-Fe-B 급속응고합금의 자기특성)

  • 조용수;김윤배;박우식;김희태;김창석;김택기
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.2
    • /
    • pp.122-125
    • /
    • 1994
  • The magnetic properties of Nd-Fe-B alloys of containing 4 at.% Nd have been studied for the development of new type rare-earth magnets. The amorphous phase of a melt-spun $Nd_{4}Fe_{85.5}B_{10.5}$ alloy is transformed into the phases which have a small amount of $Nd_{2}Fe_{14}B_{1}$ in ${\alpha}-Fe$ matrix by annealing above their crystallization temperature. The addition of Mo, Nb, V or Cu to $Nd_{4}Fe_{85.5}B_{10.5}$ alloy results in the reduction of grain size and the sub¬sequent improvement of the coercivity. The coercivity of $Nd_{4}Fe_{82}B_{10}M_{3}Cu_{1}$(M = Mo, Nb, V) alloys increases in the order of M = V < Nb < Mo and shows the highest value of 2.7 kOe when M = Mo. On the other hand, the rem¬anence of these alloys shows the opposite trend and the rn>st improved value of 1.35 T is observed when M = V.

  • PDF

SiC/SiO2 Interface Characteristics in N-based 4H-SiC MOS Capacitor Fabricated with PECVD and NO Annealing Processes (PECVD와 NO 어닐링 공정을 이용하여 제작한 N-based 4H-SiC MOS Capacitor의 SiC/SiO2 계면 특성)

  • Song, Gwan-Hoon;Kim, Kwang-Soo
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.447-455
    • /
    • 2014
  • In this research, n-based 4H-MOS Capacitor was fabricated with PECVD (plasma enhanced chemical vapor deposition) process for improving SiC/$SiO_2$ interface properties known as main problem of 4H-SiC MOSFET. To overcome the problems of dry oxidation process such as lower growth rate, high interface trap density and low critical electric field of $SiO_2$, PECVD and NO annealing processes are used to MOS Capacitor fabrication. After fabrication, MOS Capacitor's interface properties were measured and evaluated by hi-lo C-V measure, I-V measure and SIMS. As a result of comparing the interface properties with the dry oxidation case, improved interface and oxide properties such as 20% reduced flatband voltage shift, 25% reduced effective oxide charge density, increased oxide breakdown field of 8MV/cm and best effective barrier height of 1.57eV, 69.05% reduced interface trap density in the range of 0.375~0.495eV under the conduction band are observed.

A Study on the Development of Low Frequency Electronic Ignition Trans for Large Combustors (대형연소기에 적용되는 저주파 전자식 점화 트랜스 개발에 관한 연구)

  • Lee, Ho-kyun;Park, Jung-cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.223-229
    • /
    • 2022
  • In this paper, the ignition trans used in boilers was studied. Regardless of the change in the ignition rod length and the ignition rod gap, the output frequency was measured between 59.5 and 61.3 Hz, and it was found that the low frequency circuit operated normally. When the ignition rod gap changed by 2 to 10 mm, the ignition rod length was measured from 2.8A to 3.45A at 30cm. The ignition rod length was measured from 9.37 A to 14.5 A at 500 cm and from 13.2 A to 32.6 A at 1000 cm. As the ignition rod length and the ignition rod gap increased, the current increased. As a result of measuring the secondary coil output voltage. The ignition rod length was measured from AC 0.84 kV to AC 1.75 kV at 30 cm, AC 1.17 kV to AC 1.944 at 500 cm, and AC 1.4 kV to AC 7.18 kV at 1000 cm. As the ignition rod length and the ignition rod gap increased, the output voltage of the secondary coil also increased. As a result of measuring the output voltage of the ignition trans, the ignition rod length was measured from DC 1.11 kV to DC 1.57 kV at 30cm, DC 2.49 kV to DC 3.72 kV at 500cm, and DC 3.78 kV to DC 9.42 kV at 1000cm, and the power voltage increased as the ignition rod length and interval increased.

Degradation and Dielectric Properties of 22/154kV XLPE sheets (22/154kV급 XLPE의 유전특성과 절연열화)

  • Lee, Kwan-Woo;Lee, Jong-Bok;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.84-87
    • /
    • 2001
  • In this paper, degradation and dielectric properties of XLPE sheets moved from 22/154kV power cables were investigated. At the results of dielectric property of 22kV/154kV XLPE sheet, We earned that $tan{\delta}$ is $7.4{\times}10^{-4}$, $2.15{\times}10^{-4}$ and dielectric constant is 2.3, 2.24. Temperature dependance of $tan{\delta}$ inclined to increasing with temperature and increase of $tan{\delta}$ of 22kV XLPE sheet is higher than it of 154kV XLPE sheet. And increasement of XLPE sheet with water is higher than it without water.

  • PDF

Response of Electrocardiogram of Mirror Carp, Cyprinus carpio to Light Stimuli (광 자극에 대한 향어의 심전도)

  • 양용림;김영기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.124-132
    • /
    • 2001
  • The authors examined the response of electrocardiogram (ECG) of Mirror carp, Cyprinus carpio [Linnaeus] to light stimuli. The experiments were performed in such a way that three levels of light stimuli (10, 100, and 400 lux) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 60 minutes. The results which are divided into by day and by night and then analyzed by fishes conditions are as follows : 1. Mirror carps reached a stable condition 5 minutes after anesthesia. In this condition, the average heart rate was 64.9 beat/min by day and 65.3 beat/min by night. And the average action potential was 36.9 nV by day and 32.9 nV by night. 2. The average heart rate by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 68.7 beat/min by day and 46.0 beat/min by night, in case of 100 lux 53.4 beat/min by day and 44.1 beat/min by night, and in case of 400 lux 53.2 beat/min by day and 40.1 beat/min by night. 2) In a recovery condition, in case of 10 lux 67.9 beat/min by day and 57.2 beat/min by night, in case of 100 lux 68.8 beat/min by day and 61.0 beat/min by night, and in case of 400 lux 69.6 beat/min by day and 63.6 beat/min by night. 3. The average action potential by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 59.1 nV by day and 24.0 nV by night, in case of 100 lux 26.8 nV by day and 45.6 nV by night, and in case of 400 lux 71.7 nV by day and 14.4 nV by night. 2) In a recovery condition, in case of 10 lux 38.8 nV by day and 27.3 nV by night, in case of 100 lux 29.0 nV by day and 39.3 nV by night, and in case of 400 lux 66.4 nV by day and 21.4 nV by night.

  • PDF

Prediction of microstructure during high temperature forming of Ti-6Al-4V alloy (Ti-6Al-4V 합금의 고온성형 시 미세조직 예측에 관한 연구)

  • 이유환;신태진;황상무;이종수
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.57-60
    • /
    • 2003
  • The purpose of this study is to investigate the high temperature deformation behavior of Ti-6Al-4V alloy and to predict the final microstructure under given forming conditions. Equiaxed and widmanstatten of Ti-6Al-4V alloys were prepared as initial microstructure and the compression tests were performed to obtain the flow curves at high temperatures (700∼1100$^{\circ}C$) and various strain rates (10$\^$-4/∼10$^2$/s). Form the results of compression test various parameters such as strain rate sensitivity (m) and activation energy (Q) were calculated and used to establish constitutive equations. To predict the final microstructure after forming, finite element analysis was performed considering the microstructural parameters such as the grain size and the volume fraction of second phase.

  • PDF