사출금형기계용 앵귤러핀의 충격시험에 따른 파손분석과 와이블 통계 해석 (Failure Analysis and Weibull Statistical Analysis according to Impact Test of the Angular Pin for Injection Molding Machines)

  • 김철수;남기우;안석환
    • 동력기계공학회지
    • /
    • 제21권3호
    • /
    • pp.37-44
    • /
    • 2017
  • In this study, failure analysis of the angular pin for molding machines to aluminum component molding was carried out. SM45C steel was used for the angular pin, it was surface hardened by the induction surface hardening heat treatment. The cross section of damaged angular pin was observed, and micro Vickers hardness value from the fractured part was measured. Brittle fracture was occurred from the fracture surface of angular pin, therefore, impact toughness value was evaluated by V-notch Charpy impact test. It was confirmed that the impact absorption energy was high when was tempered at a high temperature for a long time, and the toughness was slightly increased. Also, 2-parameter Weibull statistical analysis was investigated in order to evaluate the reliability of the measured micro Vickers hardness values and absorbed energy. The micro Vickers hardness and absorbed energy well followed a two-parameter Weibull probability distribution, respectively. The reverse design against angular pin was proposed as possible by using test results.

비선형 음향효과에 의한 고온 재료의 파괴인성 열화도 평가 (Estimation of Fracture Toughness Degradation of High Temperature Materials by Nonlinear Acoustic Effects)

  • 정현조;남승훈;장경영;남영현
    • 비파괴검사학회지
    • /
    • 제20권5호
    • /
    • pp.424-430
    • /
    • 2000
  • 고온 장시간 사용재의 열화로 인한 파괴인성의 저하를 초음파 방법으로 평가하기 위하여 Cr-Mo-V 강을 실험실에서 인공 열화처리하여 열화로 인한 손상 기구를 규명하고, 열화도에 따른 초음파 파라미터의 변화를 체계적으로 관찰하였다. 초음파 파라미터로서 속도, 감쇠와 보다 최근에 개발된 비선형 음향 파라미터를 사용하였는데, 비선형 음향 파라미터가 가장 민감한 변화를 보였다. 또한 전기비저항 측정 결과와 비교할 때 두 방법 모두 전체적으로 유사한 거동을 보였다. Charpy V-notch 충격시험으로부터 구한 파면양상 천이온도(FATT)와 비선형 파라미터 사이에는 비교적 좋은 상관관계가 성립하였으며, FATT와 파괴인성($K_{IC}$) 사이의 관계식에 근거하여 열화된 발전설비 재료의 파괴인성을 초음파 비선형 파라미터의 측정을 통하여 간접적으로 구할 수 있음을 보였다.

  • PDF

Ductile Fracture Behaviour under Mode I Loading Using Rousellier Ductile Damage Theory

  • Oh, Dong-Joon;Howard, I.C.;Yates, J.R.
    • Journal of Mechanical Science and Technology
    • /
    • 제14권9호
    • /
    • pp.978-984
    • /
    • 2000
  • The aim of this study is to investigate the ductile fracture behaviour under Mode I loading using SA533B pressure vessel steel. Experiments consist of the Round Notch Bar Test (RNB), Single Edge Crack Bending Test (SECB), and V-Notch Bar Test (VNB). Results from the RNB test were used to tune the damage modelling constant. The other tests were performed to acquire the J-resistance curves and to confirm the damage constants. Microstructural observation includes the measurement of crack profile to obtain the roughness parameter. Finally, simulation using Rousellier Ductile Damage Theory (RDDT) was carried out with 4-node quadrilateral element ($L_c=0.25\;mm$). For the crack advance, the failed element removal technique was adopted with a ${\beta}$ criterion. In conclusion, the predicted simulation using RDDT showed a good agreement with the experimental results. A trial using a roughness parameter was made for a new evaluation of J-resistance curve, which is more conservative than the conventional one.

  • PDF

노치 ( Notch )를 가진 試片의 有限要素法에 의한 彈塑性 極限 荷重解析 (Elacstic-\Plastic Limit Load Analysis of Notched Specimen by the Finite Element Method)

  • 이택순;김동섭;황평
    • 대한기계학회논문집
    • /
    • 제7권4호
    • /
    • pp.379-385
    • /
    • 1983
  • Many papers have shown limit loads of v-notched tension specimens in plane stress by the elastic-plastic finite element method. But they are always higher than the theoretical maximum loads. The present approach tries to find the reasons and formulates correction factor applicable to any notch shape using virtual work principle with triangular elements. The corrected limit loads are in good agreement with theoretical upper bound solutions and they are little influenced by mesh size and specimen length, which make the computing time save.

Acoustic emission technique to identify stress corrosion cracking damage

  • Soltangharaei, V.;Hill, J.W.;Ai, Li;Anay, R.;Greer, B.;Bayat, Mahmoud;Ziehl, P.
    • Structural Engineering and Mechanics
    • /
    • 제75권6호
    • /
    • pp.723-736
    • /
    • 2020
  • In this paper, acoustic emission (AE) and pattern recognition are utilized to identify the AE signal signatures caused by propagation of stress corrosion cracking (SCC) in a 304 stainless steel plate. The surface of the plate is under almost uniform tensile stress at a notch. A corrosive environment is provided by exposing the notch to a solution of 1% Potassium Tetrathionate by weight. The Global b-value indicated an occurrence of the first visible crack and damage stages during the SCC. Furthermore, a method based on linear regression has been developed for damage identification using AE data.

J-적분 평가를 이용한 콘크리트 파괴 특성 (Fracture Properties of Concrete by using the J-integral)

  • 최신호;계해주;김화중
    • 콘크리트학회논문집
    • /
    • 제13권4호
    • /
    • pp.371-378
    • /
    • 2001
  • 콘크리트의 파괴 특성을 평가하기 위한 매개변수, 모델, 그리고 시험방법 등이 현재 많이 제안되고 있으며, 이러한 발전으로 최근에는 콘크리트의 비선형 파괴와 준취성 파괴를 해석 가능하게 하고 있다. 이 논문에서는 파괴 매개변수에 대하여 간략히 소개하고 3점 휨시험을 시행하여 콘크리트의 파괴인성을 나타내는 J-적분값 ($J_{Ic}$ )과 다른 매개변수($K_{Ic}$ , $G_{F}$ )를 비교하였다. 콘크리트 보 시험체의 두께(width)와 노치 길이에 따라 파괴인성값이 어떻게 변화하는지를 실험적으로 고찰하였고 콘크리트 파괴 인성을 측정하기 위해서 응력-변위 곡선을 사용하였다. $G_{F}$$ J_{Ic}$ 의 값은 노치 길이가 클수록 감소하는 경향을 보이며 $G_{F}$$J_{Ic}$ 보다 덜 민감한 반응을 보이는 것으로 나타났다. 따라서, 콘크리트 파괴 인성 매개변수로써 전자가 후자보다 더 유용한 것으로 나타났다. $G_{v}$$J_{Ic}$ 의 값은 콘크리트 시험체 두께가 75mm에서 150mm로 커질 때 증가한다. 따라서, 시험체 두께의 영향이 콘크리트 파괴 인성을 결정할 때 고려되어져야 한다.

유압 액셜 피스톤 펌프의 실린더 포트 내부 비정상 압력특성에 관한 연구 (A study on the characteristics of dynamic pressure in cylinder pen of hydraulic axial piston pump)

  • 김종기;정재연
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.209-214
    • /
    • 1999
  • Dynamic pressure is one of the major sources on noise emission in hydraulic axial piston pump. This paper reports an experimental study of dynamic pressure characteristics in the cylinder port of hydraulic axial piston pump. We investigated dynamic pressure with not only the effect of delivery pressure, rotational speed and temperature but also V-notches at the ends of the kidney ports in the valve plate. We experimented three valve plates with three type V-notches at the ends of the kidney ports, because V-notches of the valve plate is known of noise reduction. Finally, we hope this paper help to design of the valve plate in hydraulic axial piston pump.

  • PDF

고장력강 용접부에 있어서 한계 COD값과 V charpy충격치와의 상관성에 관한 연구 (A study on the correlation between V charpy absorbed energy and critical COD value in the welded parts of high tensil strength steel under various welding methods)

  • 김영식;김충해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.57-67
    • /
    • 1988
  • Although handicapped by the inability to bridge the size gap between small laboratory sample and large engineering component, the V charpy test sample method does possess certain advantages, such as each of preparation, simplicity of test method, speed, low cost in test machinery, and low cost per test. On the other hand, the COD test method does posses advantages, which reduce the size gap between the laboratory sample and actual engineering component. Consequently, the correlation between V charpy absorbed energy and the critical COD value is required for estimating critical COD value from the simple V charpy test results. In this paper, the high tensile strength steel AH36 plate specimens having a single edge cracked notch were investigated to find out the correlation between V charpy absorbed energy and critical COD value in the welded parts under such various welding methods as shielded metal arc welding, the submerged arc welding and the electro gas welding by means of V charpy impact test and static 3-point bending test. Main results obtained are as follow ; 1. The relationships between V charpy absorbed energy Wc' and critical COD value ($\delta_c$)show; $\delta_c$=0.0065 Wc'+0.1906. 2. Ductile- brittle transition behaviours can be estimated by means of fracture appearance and general yielding behaviours. 3. The V charpy absorbed energy of SMAW is higher than that of SAW, EGW and similar relationships are obtained in the COD tests.

  • PDF

FRACTURE TOUGHNESS CHARACTERISTICS IN HIGH ENERGY DENSITY BEAM WELDED JOINT OF HIGH TENSILE STEELS

  • Ro, Chan-Seung;Yamada, Tomoaki;Mochizuki, Masahito;Ishikawa, Nobuyuki;Bang, Han-Sur;Toyoda, Masao
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.583-588
    • /
    • 2002
  • The purpose of the study is to evaluate fracture toughness on the Laser and the electron beam welded joints of high tensile steels (HT500, HT550, HT650) by using 3-point bend CTOD and Charpy impact test. WM (weld metal) CTOD tests have been carried out using two kinds of CTOD specimen, the Laser beam welding (108mm length, and 24mm width, and 12mm thickness) and the electron beam welding (l71mm length, and 38mm width, and 19mm thickness). WM Charpy impact specimen is a standard V-notch type, and the temperature of the experiment is changed from -45 to 20 degree of centigrade. FE-analysis is also performed in order to investigate the effect of stress-strain fields on fracture characteristics. Results of the standard V-notch Charpy test are influenced by strength mis-match effect and the absorbed energy vE depends on crack path, and The transition temperature of Laser beam welded joints is more higher than that of electron beam welded joints. Results of the 3-point bend test give low critical CTOD and the crack path is in the weld metal of al specimens. These results indicate fracture toughness characteristics of the welded joints and transition temperature of HT500 are similar both a Laser beam welded joint and an electron beam welded joint. But the fracture toughness and the transition temperature of the electron beam welded joints of HT550 and HT650 are higher than those o the Laser beam welded joints.

  • PDF

Microleakage of Class V cavity restored with flowable and microfill composite resins after load cycling.

  • Kang, Suk-Ho;Son, Ho-Hyun
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.569.2-569
    • /
    • 2001
  • Flowable and microfill composites have been recommended for Class V cavities. But the use of flowable composites is controversial because of its physical properties. Objectives: The aim of this study was to evaluate the microleakage of 6 composites (2 hybrids, 2 microfills, and 2 flowable composites) with/without load cycling. Methods: Notch-shaped Class V cavities were prepared on buccal surfaces of 180 extracted human upper premolars and then divided into non-load cycling group(G1) and load cycling group(G2).(omitted)

  • PDF