• 제목/요약/키워드: V-Slot

검색결과 83건 처리시간 0.026초

전력선 주파수를 이용한 가시광 채널의 시분할 전송 (Time Division Transmission of Visible Light Channels Using Power Line Frequency)

  • 이성호
    • 센서학회지
    • /
    • 제23권5호
    • /
    • pp.349-355
    • /
    • 2014
  • In this paper, we developed a new method to transmit multiple visible light channels in time division mode using the AC power line frequency in order to prevent the crosstalk between adjacent optical signals. Synchronizing pulses are generated from the 220 V power line, and one pulse period is subdivided into several time slots for visible light channels. Each channel transmits data in a predefined time slot without interfering adjacent channels. In experiments, synchronizing pulses with a repetition rate of 240 Hz were generated from the 60 Hz power line, and three VLC channels with a bit rate of 9.6 kbps transmitted data independently using the time slots between synchronizing pulses. This configuration is very useful in constructing time division VLC networks for multiple sensors.

회전기 고정자 권선의 부분방전 진단을 위한 평면 Patch Sensor 설계 (The Design of a patch Sensor for Partial Discharge diagnosis in Rotating Machine Stator Windings)

  • 양상현;임광진;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.97-98
    • /
    • 2008
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which transmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analyzes the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF

Contact problem for a stringer plate weakened by a periodic system of variable width slots

  • Mir-Salim-zada, Minavar V.
    • Structural Engineering and Mechanics
    • /
    • 제62권6호
    • /
    • pp.719-724
    • /
    • 2017
  • We consider an elastic isotropic plate reinforced by stringers and weakened by a periodic system of rectilinear slots of variable width. The variable width of the slots is comparable with elastic deformations. We study the case when the slots faces get in contact at some area. Determination of parameters characterizing the partial closure of variable width slots is reduced to the solution of a singular integral equation. The action of the stringers is replaced with unknown equivalent concentrated forces at the points of their connection with the plate. The contact stresses and contact zone sizes are found from the solution of the singular integral equation.

농도구배가 삼지화염의 부상특성에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Lift-off Characteristics of the Triple Flame with Concentration Gradient)

  • 서정일;김남일;오광철;신현동
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.7-14
    • /
    • 2004
  • The lift-off characteristics of the triple flame have been studied experimentally with various mean velocities and concentration gradients using a multi-slot burner, which can control the concentration gradient and the mean velocity independently, Lift-off height, axial maximum velocity, flame temperature, and some other characteristics were examined for methane and propane flame, It was found that minimum values of the lift-off heights exist at a certain concentration gradient for constant mean velocity, and this result implies that the propagation velocity has a maximum value at this condition, OH radical distribution was measured with LIF method and velocity variation along streamline was measured with PlV system. In addition maximum temperature along streamline was measured with CARS system. The intensity of the diffusion flame affects on the propagation velocity of triple flame in the region of very weak concentration gradient.

  • PDF

견인전동기 고정자 권선의 절연진단 특성 (Characteristics of Insulation Diagnostic in Traction Motor Stator Windings)

  • 김희동;김충효;박영;박현준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.336-338
    • /
    • 2006
  • Diagnostic tests are used to evaluate the insulation condition of stator windings in traction motor. These tests included ac current, tan delta and maximum partial discharge. The insulation condition of stator windings was assessed by three test items. The stator windings of traction motor were m good condition. After completing the diagnostic tests, the stator windings of traction motors were subjected to gradually increasing ac voltage, until the insulation punctured. No.5 stator windings failed near rated voltage of 18.9 kV. The breakdown voltage of No.1 stator windings was 13.0. The failure was located m a line-end coil at the exit from the core slot.

  • PDF

원형편파를 갖는 원형 링 마이크로스트립 슬롯 안테나 (Printed Annular Ring Slot Antenna for Circular Polarization)

  • 이태훈;김명석;김재학;김영두;김호용;이홍민
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.302-305
    • /
    • 2002
  • 본 논문에서는 기존의 원형 링 마이크로스트립 슬롯 안테나에 십자슬롯과 truncated를 통하여 원형편파를 구현할 수 있는 새로운 안테나 구조를 제안하였다. 금전구조는 입력단 설계가 간단하고 정함이 쉬운 전자파 결합방식을 사용하였고, Ansoft HFSS V8.0으로 최적화 한 후 제작 및 측정하였다. 제안된 안테나는 GPS(1.55MHz)대역에서 원형편파(RHCP, LHCP)특성을 만족하고, 각각의 안테나 구조에서 7.74%의 임피던스 대역폭(VSWR$\leq$2)을 갖고 안테나의 방사소자를 소형화하였다. 이는 기존의 월평 링 마이크로스트립 슬롯 안테나의 임피던스 대역폭 및 편파특성을 획기적으로 개선한 것이다.

  • PDF

Coflow-Counterflow 개념을 이용한 추력벡터 노즐에서 발생하는 유동특성에 관한 연구 (A Study of Thrust-Vectoring Nozzle Flow Using Coflow-Counterflow Concept)

  • 정성재;;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.592-597
    • /
    • 2003
  • Thrust vector control using a coflow-counterflow concept is achieved by suction and blowing through a slot adjacent to a primary jet which is shrouded by a suction collar. In the present study, the flow characteristics of thrust vectoring is investigated using a numerical method. The nozzle has a design Mach number of 2.0, and the operation pressure ratio is varied to obtain various flow features of the nozzle flow. Test conditions are in the range of the nozzle pressure ratio from 6.0 to 10.0, and a suction pressure from 90kPa to 35kPa. Two-dimensional, compressible Navier-Stokes computations are conducted with RNG ${\kappa}-{\varepsilon}$ turbulence model. The computational results provide an understanding of the detailed physics of the thrust vectoring process. It is found that an increase in the nozzle pressure ratio leads to increased thrust efficiency but reduces the thrust vector angle.

  • PDF

가스터빈 구동 공냉식 100 MW 발전기의 개념설계 (Conceptual Design of 100 MW Turbogenerator)

  • 박도영;황돈하;하경덕;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.88-90
    • /
    • 1998
  • The conceptual design of turbine-driven air-cooled 100 MW generator is presented. The generators rating is 100 MW 3-phase 2pole 13.8 kV 0.85 pf 60 Hz. The conceptual design is described by the process of designing the stator, rotor, and obtaining some of equivalent circuit parameters. The design process starts from the output coefficient G, and utilizes the classical design equations with parameters used in the modern designs. The slot dimensions of the stator and rotor are obtained with their respective winding dimensions.

  • PDF

대용량 터빈발전기 고정자 권선의 정지중 및 운전중 부분방전 특성 (Off-Line and On-Line Partial Discharge Properties of Large Turbine Generator)

  • 김희동;이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1846-1849
    • /
    • 2000
  • Off-line and on-line partial discharges were measured on a 828MVA, 22kV and direct hydrogen-cooled large turbine generator. Partial discharge tests were conducted using digital partial discharge detector(PDD) and turbine generator analyzer(TGA). PDD and TGA showed that off-line partial discharge pattern seems to be very, similar to that found with on-line. Most of the partial discharge is originating with the stator slot in the three phases. As the partial discharge activity is very low, the stator insulation condition of this generator is very good.

  • PDF

수력발전기 고정자 권선에서 부분방전 특성 (Partial Discharge Property of Hydrogenerator Stator Windings)

  • 김희동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.86-90
    • /
    • 2000
  • Partial discharge(PD) tests were performed when the hydrogenerator(rated 11kV and 25MVA) was shut down(off-line). Six cable couplers were installed in the ring bus as well as within hydrogenerator terminal box. PD tests were conducted using partial discharge analyzer(PDA) and digital partial discharge detector(PDD). PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude increased with increase of ac voltage. Slot discharges were discovered in three phases(A, B and C) at the rated voltage. PDA and PDD test results are in accordance with the pattern and magnitude of partial discharge. This hydrogenerator stator windings were in good condition.

  • PDF