• Title/Summary/Keyword: V-Model

Search Result 3,772, Processing Time 0.037 seconds

AN ANALYTICAL DC MODEL FOR HEMTS (헴트 소자의 해석적 직류 모델)

  • Kim, Yeong-Min
    • ETRI Journal
    • /
    • v.11 no.2
    • /
    • pp.109-119
    • /
    • 1989
  • Based on the 2-dimensional charge-control simulation[4], a purely analytical model for MODFET's is proposed. In this model, proper treatment of the diffusion effect in the 2-DEG transport due to the gradual channel opening along the 2-DEG channel was made to explain the enhanced mobility and increased thershold voltage. The channel thickness and gate capacitance are experssed as functions of gate vlotage including subthreshold characteristics of the MODFET's analytically. By introducing the finite channel opening and an effective channel-length modulation, the slope of the saturation region of the I-V curves was modeled. The smooth transition of the I-V curves from linear-to-saturation region of the I-V curves was possible using the continuous Troffimenkoff-type of field-dependent mobility. Furthermore, a correction factor f was introduced to account for the finite transtition section forming between the GCA and the saturated section. This factor removes the large discrepanicies in the saturation region fo the I-V curves presicted by existing 1-dimensional models. The fitting parameters chosen in our model were found to be predictable and vary over relatively small range of values.

  • PDF

A Coherent Methodology for the Evaluation of a Steam Explosion Load Using TEXAS-V

  • Song, Jin-Ho;Park, Ik-Kyu;Kim, Jong-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.571-581
    • /
    • 2004
  • A methodology is proposed for the evaluation of a steam explosion load on a reactor scale by evaluating the steam explosion model against the experimental data. Being part of the OECD/SERENA program,, appropriate data was selected by international experts and the analytical model of TEXAS-V was chosen. The procedure consists of two steps. the pre-mixing model was verified against the FARO L-14 and FARO L-28 data. The explosion model was verified against the experimental data of KROTOS-44, FARO L-33, TROI-13, and TROI-34. The capabilities and deficiencies of the fundamental models of the TEXAS-V are reviewed in terms of their adequacy in a simulation of steam explosion on a reactor scale.

Insulating Design and Test of 22.9kV Class Mini-Model Transformer Considering AC Loss (AC Loss를 고려한 22.9kV급 Mini-Model 변압기의 절연 설계 및 시험)

  • 백승명;정종만;곽동순;김해종;석복렬;김상현
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.8
    • /
    • pp.420-424
    • /
    • 2004
  • This paper presents experimental data from model windings with different arrangement of coil in order to provide information to design a 22.9kV class HTS transformer. Before experiment, the composite insulation of two different type of HTS transformers are investigated. The first basic of investigation is a breakdown characteristic of liquid nitrogen and flashover characteristic on the GFRP surface under ac and impulse, The second investigation is insulation design, manufacture and test of model windings. These include a AC withstand voltage test of 50 kV rms and a lighting impulse test of 150 kV at peak.

Temperature Rise Prediction of 25.8kV 25kA Three-phase GIS Bus Bar (25.8kV 25kA 3상 GIS 모선의 온도상승 예측)

  • Kim, Joong-Kyoung;Hahn, Sung-Chin;Oh, Yeon-Ho;Park, Kyong-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.894-895
    • /
    • 2007
  • This paper presents coupled analysis between finite element method and analytic technique for predicting temperature rise of 25.8kV 25kA three-phase GIS bus bar. The power losses and temperature distribution of three-phase GIS bus bar model are analyzed by magneto-thermal finite element method. The heat transfer coefficients on the boundaries are analytically calculated by applying Nusselt number considering material constant and model geometry for the natural convection. And these are used as the input data to predict the temperature rise of three-phase GIS bus bar model by coupled magneto-thermal F.E.A. The predicted temperature of 25.8kV 25kA three-phase GIS bus bar model shows good agreement with the experimental data.

  • PDF

Software Reliability of Safety Critical FPGA-based System using System Engineering Approach

  • Pradana, Satrio;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.14 no.2
    • /
    • pp.49-57
    • /
    • 2018
  • The main objective of this paper is come up with methodology approach for FPGA-based system in verification and validation lifecycle regarding software reliability using system engineering approach. The steps of both reverse engineering and re-engineering are carried out to implement an FPGA-based of safety critical system in Nuclear Power Plant. The reverse engineering methodology is applied to elicit the requirements of the system as well as gain understanding of the current life cycle and V&V activities of FPGA based-system. The re-engineering method is carried out to get a new methodology approach of software reliability, particularly Software Reliability Growth Model. For measure the software reliability of a given FPGA-based system, the following steps are executed as; requirements definition and measurement, evaluation of candidate reliability model, and the validation of the selected system. As conclusion, a new methodology approach for software reliability measurement using software reliability growth model is developed.

Classification of Urinary Stone into Uric Acid & Non-uric Acid by Dual-Energy (이중에너지 전산화단층촬영을 이용한 요로결석의 성분 분석에 관한 연구)

  • Myung-Jin Jung;Sung-Gil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.835-841
    • /
    • 2023
  • The aim of this study is to evaluate the diagnostic ability of dual-energy computed tomography (DECT) for Composition determination of urinary stones in phantom model. Seventeen cases with urinary stones who underwent DECT were enrolled in the study. The composition of the urinary stones was extracted from the seventeen patients were analyzed with DECT in phantom model with fresh pork. The volume scan method using Dual-energy software was used and the scanned image sets were assessed. All 17 urinary stones of the phantom model were analyzed according to the stone composition using DE stone Analysis were divided into uric acid stones (n=6, 35.29%) and non-uric acid stones (n=11, 64.71%). These urinary stones were pathologically confirmed. The mean attenuation values of uric acid stones at 135 kV, 100 kV and 80 kV was 348.87 ± 166.37 HU, 345.33 ± 151.18 HU and 337.94 ± 172.77 HU, respectively. The mean attenuation values of non-uric acid stones at 135 kV, 100 kV and 80 kV was 551.93 ± 297.09 HU, 747.04 ± 351.31 HU and 958.19 ± 424.72 HU, respectively. At 80 kV, uric acid stones and non-uric acid stones showed significant difference in the attenuation values(P<0.05). The attenuation values of DECT could differentiate the compositions of urinary stones between uric acid and non-uric acid stones at 80 kV in phantom model.

Analysis of a Parasitic-Diode-Triggered Electrostatic Discharge Protection Circuit for 12 V Applications

  • Song, Bo Bae;Lee, Byung Seok;Yang, Yil Suk;Koo, Yong-Seo
    • ETRI Journal
    • /
    • v.39 no.5
    • /
    • pp.746-755
    • /
    • 2017
  • In this paper, an electrostatic discharge (ESD) protection circuit is designed for use as a 12 V power clamp by using a parasitic-diode-triggered silicon controlled rectifier. The breakdown voltage and trigger voltage ($V_t$) of the proposed ESD protection circuit are improved by varying the length between the n-well and the p-well, and by adding $n^+/p^+$ floating regions. Moreover, the holding voltage ($V_h$) is improved by using segmented technology. The proposed circuit was fabricated using a $0.18-{\mu}m$ bipolar-CMOS-DMOS process with a width of $100{\mu}m$. The electrical characteristics and robustness of the proposed ESD circuit were analyzed using transmission line pulse measurements and an ESD pulse generator. The electrical characteristics of the proposed circuit were also analyzed at high temperature (300 K to 500 K) to verify thermal performance. After optimization, the $V_t$ of the proposed circuit increased from 14 V to 27.8 V, and $V_h$ increased from 5.3 V to 13.6 V. The proposed circuit exhibited good robustness characteristics, enduring human-body-model surges at 7.4 kV and machine-model surges at 450 V.

Korea Software Development Process W-model (한국형 소프트웨어 개발 프로세스 W-model)

  • Lim, Na-Rae;Kim, Min-Je
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.1327-1328
    • /
    • 2011
  • 소프트웨어 개발 프로세스인 V-model 은 미국이나 유럽과 같이 소프트웨어 개발 프로세스의 역할이 잘 정립되어 있는 곳에서는 적용이 쉬우나 우리나라의 개발 실정에는 맞지 않는 경향이 있다. 이 논문에서는 한국의 현실을 반영하여 기존 model 인 V-model 대신 한국실정을 반영하는 W-model을 제시하려고 한다.