• Title/Summary/Keyword: V-Model

Search Result 3,792, Processing Time 0.029 seconds

Analysis of the Induced Voltage on the 154kV Underground Cable (154kV 지중케이블에서 유기전압의 해석)

  • Choi, Suk-Young;Yoo, Myeong-Ho;Bai, Doo-Han;Oh, Jung-Hwan;Rim, Seong-Jeong;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1184-1186
    • /
    • 1997
  • In this paper, we analyze the induced voltage and current in the underground transmission cable. To analyze it, we select the 154[kV] underground transmission system which is located in the city. In the case of the steady state, the single phase fault, and three phase fault in the underground cable, we analyze the induced voltage and current for an equivalent model through EMTP simulation. Also, the components of an equivalent model and the computer simulation using EMTP is described.

  • PDF

A Comparative Study of Operating Angle Optimization of Switched Reluctance Motor with Robust Speed Controller using PSO and GA

  • Prabhu, V. Vasan;Rajini, V.;Balaji, M.;Prabhu, V.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.551-559
    • /
    • 2015
  • This paper's focus is in reducing the torque ripple and increasing the average torque by optimizing switching angles of 8/6 switched reluctance motor while implementing a robust speed controller in the outer loop. The mathematical model of the machine is developed and it is simulated using MATLAB/Simulink. An objective function and constraints are formulated and Optimum turn-on and turn-off angles are determined using Particle swarm optimization and Genetic Algorithm techniques. The novelty of this paper lies in implementing sliding mode speed controller with optimized angles. The results from both the optimization techniques are then compared with initial angles with one of them clearly being the better option. Speed response is compared with PID controller.

Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks

  • Jaipradidtham, Chamni
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1637-1640
    • /
    • 2005
  • This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground conductivity influences both the electric field as well as the coupling mechanism and hence the magnitude and wave shape of the induced voltage. The technique can be used to analyzed the corona voltage effect, the effective of stroke to the span tower, the surge impedance of transmission lines. The maximum voltage from flashovers effects in the lines. The model is compatible with general electromagnetic transients programs such as the ATP-EMTP. The simulation results show that this study analyses for time-domain with those produced by a cascade multi-section model, the surge impedance of a full-sized tower hit directly by a lightning stroke is discussed.

  • PDF

Effect of an herbal formulation on DOCA-salt and fructose induced models of hypertension in rats

  • Athare, CL;Mohan, M;Kasture, SB
    • Advances in Traditional Medicine
    • /
    • v.8 no.4
    • /
    • pp.354-364
    • /
    • 2008
  • The present study was carried out to investigate the antihypertensive effect of a folklore herbal formulation (HF) (300mg/kg/day; p.o.) in deoxycorticosterone acetate (DOCA)-salt induced and fructose induced hypertensive rats. In DOCA model, DOCA (15 mg/kg, s.c., twice a week) was administered to unilateral nephrectomized rats for 4 weeks. In fructose model, drinking water was replaced with 10% fructose solution for 6 weeks to induce hypertension. Systolic blood pressure (BP) was measured once every week during the treatment schedule. After completion of treatment schedule, BP and vascular reactivity to various agonists like Noradrenaline, Adrenaline, Phenylephrine and Serotonin (5-hydroxytrptamine; 5-HT) were recorded in rats of both models. A cumulative concentration response curve of 5-HT was carried out in isolated rat fundus strip of the DOCA-salt induced and fructose induced hypertensive rats. The results tend to suggest that HF possesses antihypertensive activity.

Investigation and Countermeasure of P.T Ferroresonance in the 154kV GIS Substation (154kV GIS 변전소 P.T. 철공진 규명 및 방지대책)

  • Choi, W.S.;Kim, S.K.;Jee, S.K.;Kim, S.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.541-543
    • /
    • 2002
  • This paper describes the analysis resulates on the P.T ferroresonance at 154kV GIS(Gas Insulated Substation) by EMTP(Electromagnetic transient program). We had simulated the PT ferroresonance between a potential transformer(PT) and open circuit braker's grading capacitance. The ferroresonance leads to very large power frequency overvoltage on PT bus and subsequent insulation failure. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series mounted, but the 2 ohms of damping resistance was used in the computational model.

  • PDF

CCD SNAPSHOTS OF FIELDS IN A STUDY OF THE VERTICAL DISTRIBUTION OF STARS

  • CHEN ALFRED B.;TSAY WEAN-SHUN;LU PHILLIP K.;SMITH ALLYN;MENDEZ RENE
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.123-124
    • /
    • 1996
  • Snapshots of eight SA and standard fields from low to high galactic latitudes were made using the KPNO 0.9m 2K $\times$ 2K CCD with a limiting magnitude from 19 to 22.5. The purpose of this study is to determine the vertical distribution of stars with respect to Galactic latitude and z-distance in comparison with the model simulation between intermediate population to the 'thick disk' component of scale height of a few kpc. Comparison of the preliminary results between observed and model simulation for 3 of the S fields shows good agreement both in V-mag and B- V color distributions. A bimodal distribution in B- V at high galactic latitude seems to be represented by a halo and 'thick disk' dwarf in the blue and by a normal disk dwarf population in the red.

  • PDF

Numerical Simulation of a Reciprocating Compressor (왕복동 압축기의 성능해석 시뮬레이션)

  • 김정우;김현진;박희용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.2
    • /
    • pp.475-483
    • /
    • 1993
  • A computer simulation model of a hermetic reciprocating type of refrigeration compressor has been developed. The compressor simulation model constitutes 6 control volumes, to each of which conservation laws of mass and energy are applied to yield full description of the refrigerant state along its passage. Instead of ideal gas assumption. real gas equation is employed. Some of valve-related input data required for the simulation are acquired from test bench experiments. The refrigerant states such as pressure and temperature, etc., mass flow rates, and valve motions can be predicted by the simulation. The calculated P-V diagram shows a good agreement with experimental result.

Staticand Dynamic Design of Zipper Columns in Inverted V Braced Steel Frames (역V형 철골 중심가새골조의 정적/동적 지퍼기둥.설계법)

  • Lee Cheol-Ho;Kim Jung-Jae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.733-740
    • /
    • 2006
  • Inverted V (or chevron) braced steel frames have been seen as being highly prone to soft story response once the compression brace buckles under earthquake loading. To salvage chevron braced frames. the concept of the zipper column was proposed many years ago such that the zipper column can redistribute the inelastic demand over the height of the building. However. rational design method for the zipper column has not been established yet. In this paper, a new dynamic design method for the zipper column was proposed by combining the refined physical braced model and modal pushover analysis. Inelastic dynamic analysis conducted on 6 story building model showed that the proposed method was more superior to the existing static design method and was very effective in improving seismic performance of chevron braced steel frames.

  • PDF

Electrooptic Response of Reflective Liquid Crystal Cell

  • Lee, Geon-Joon;C. H. Oh;Lee, Y. P.;T. K. Lim
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.S1
    • /
    • pp.33-35
    • /
    • 2003
  • The electrooptic properties of the reflected light in a reflective mode, $45^{\circ}C$twisted nematic liquid crystal (TNLC) cell were investigated in the voltage regions near and away from the Freedericksz transition threshold. The measured reflectivity away from the threshold voltage ($V_th$) could not be described by the model which assurnes a constant tilt angle as well as a linearized distribution of twist angle across the cell, although the data are well fitted near $V_th$. We found that in the voltage region away from $V_th$, the model considering the distributions of the tilt angle and the twist angle should be applied for the calculation of the reflectivity. The director-axis distributions were obtained from the numerical integration of the Euler-Lagrange equation.

OPTIMAL CONTROL ANALYSIS FOR THE MERS-COV OUTBREAK: SOUTH KOREA PERSPECTIVES

  • LEE, DONGHO;MASUD, M.A.;KIM, BYUL NIM;OH, CHUNYOUNG
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.21 no.3
    • /
    • pp.143-154
    • /
    • 2017
  • This paper presents the mathematical model for the MERS-CoV outbreak in South Korea, and the optimal control for two intervention strategies (contact, hospitalization) is implemented. After the MERS-CoV outbreak, hospitalizing infected individuals did not help to prevent the spread of infection. However, the intervention to control contact was effective. It was effective the intervention to controlling both of contact and hospitalization of infection population.