• Title/Summary/Keyword: V-Factor

Search Result 2,486, Processing Time 0.026 seconds

A Study on Accelerated Life Test of Halogen Lamps for Medical Device (의료용 할로겐램프의 가속수명시험에 관한 연구)

  • Jung, Jae Han;Kim, Myung Soo;Lim, Heonsang;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.4
    • /
    • pp.659-672
    • /
    • 2013
  • Purpose: The purpose of this study was to estimate life time of halogen lamps and acceleration factors using accelerated life test. Methods: Voltage was selected as an accelerating variable through the technical review about failure mechanism. The test was performed at 14.5V, 15.5V and 16.5 for 4,471 hours. It was assumed that the lifetime of Halogen lamps follow Weibull distribution and the inverse power life-stress relationship models. Results: Mean lifetimes of pin and screw types were 19,477 hours and 6,056 hours, respectively. In addition, acceleration factor of two items are calculated as 4.8 and 2.2 based on 15.5V, respectively. Conclusion: The life-stress relationship, acceleration factor, and MTTF at design condition are estimated by analyzing the accelerated life test data. These results suggest that voltage was very important factor to accelerate life time in the case of halogen lamps and the life time of pin type is three times longer than screw type lamps.

High Voltage Ti/4H-SiC Schottky Rectifiers (고전압 Ti/4H-SiC 쇼트키 장벽 다이오드 제작 및 특성분석)

  • Kim, C.K.;Yang, S.J.;Lee, J.H.;Noh, I.H.;Cho, N.I.;Kim, N.K.;Kim, E.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.834-838
    • /
    • 2002
  • In this paper, we have fabricated 4H-SiC schottky diodes utilizing a metal-oxide overlap structure for electric filed termination. The barrier height and Ideality factor were measured by current-voltage, capacitance-voltage characteristics. Schottky barrier height(SBH) were 1.41ev for Ni and 1.35eV for Pt, 1.52eV for Pt/Ti at room temperature and Pt/Ti Schottky diode exhibited Ideality factor was 1.06 to 1.4 in the range of $25^{\circ}C{\sim}200^{\circ}C$. To improve the reverse bias characteristics, an edge termination technique is employed for Pt/Ti/4H-SiC Schottky rectifiers and the device show excellent characteristics with higher blocking voltage up to 780V compared with unterminated devices.

  • PDF

Administration Route Dependency of Distribution of Distribution pf PEGylated Recombinant Human Tumor Necrosis Factor Binding Protein (rhTNFbp-PEG20K dimer) following i.v. and s.c. Injection

  • Kim, Dong-Chool;Duane C. Bloedow
    • Archives of Pharmacal Research
    • /
    • v.17 no.5
    • /
    • pp.381-382
    • /
    • 1994
  • Administration route dependency on the distribution of PEGylated recombinant human turor necrosis factor binding protein (rhTNFbp-PEG20K dimer) was observed following a subcutaneous (sc) and an intravenous (iv) administrationin rats. ehTNFbp-PEG20K dimer is composed of two rhTNGbp molecules (molecular weight 18, 278 daltons each) joined by polyethylene glycol 2000(PEG30K). The steady state distribution volume of rhTNFbp-PEG20K was 55 m/kg and 359 ml/kg following the i.v. and s.c. administrations, respectively. These results suggest that the distribution of ehTNFbp-PEG20K is limited within the cpillary space after i.v. administration, while rhTNFbp-PEG20K can distribute into a space (35.9% of body weight) which is between extracellylar space and total body water. A lymphatic absorption may paly a role in the distribution of rhTNFbp-PEF20K dimer following the sc administration. The present study suggests that the administration route of a lartge protein molecule should be determined depedning upon target sites.

  • PDF

γ-Ray Shielding Behaviors of Some Nuclear Engineering Materials

  • Mann, Kulwinder Singh
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.792-800
    • /
    • 2017
  • The essential requirement of a material to be used for engineering purposes at nuclear establishments is its ability to attenuate the most penetrating ionizing radiations, gamma $({\gamma})-rays$. Mostly, high-Z materials such as heavy concrete, lead, mercury, and their mixtures or alloys have been used in the construction of nuclear establishments and thus termed as nuclear engineering materials (NEM). The NEM are classified into two categories, namely opaque and transparent, depending on their behavior towards the visible spectrum of EM waves. The majority of NEM are opaque. By contrast, various types of glass, which are transparent to visible light, are necessary at certain places in the nuclear establishments. In the present study, ${\gamma}-ray$ shielding behaviors (GSB) of six glass samples (transparent NEM) were evaluated and compared with some opaque NEM in a wide range of energy (15 keV-15 MeV) and optical thickness (OT). The study was performed by computing various ${\gamma}-ray$ shielding parameters (GSP) such as the mass attenuation coefficient, equivalent atomic number, and buildup factor. A self-designed and validated computer-program, the buildup factor-tool, was used for various computations. It has been established that some glass samples show good GSB, thus can safely be used in the construction of nuclear establishments in conjunction with the opaque NEM as well.

Stripping Method of Ring Laser Gyroscope Based on Measurement Model of Dither Motion (디더 운동 측정치 모델 기반 링레이저 자이로 스트리핑 방법)

  • Kim, Cheon-Joong;Shim, Kyu-Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.531-536
    • /
    • 2014
  • There are trapping and stripping methods as the technique to remove the dither motion from RLG(Ring Laser Gyro) output. V/F converter output of angular sensor to measure the dither motion is used in stripping method. But bias and scale factor error is always included in V/F converter output and is a critical limiting factor for the wide application of stripping method to RLG. Therefore there have been many researches to solve this problem. The method to accurately estimate the bias and scale factor error of V/F converter using measurements of the angular sensor acquired at data sampling rate of INS is presented in this paper. To this end, stripping technique based on model of dither motion is newly applied.

Pullout capacity of shallow inclined anchor in anisotropic and nonhomogeneous undrained clay

  • Bhattacharya, Paramita
    • Geomechanics and Engineering
    • /
    • v.13 no.5
    • /
    • pp.825-844
    • /
    • 2017
  • This study aimed to find out the pullout capacity of inclined strip anchor plate embedded in anisotropic and nonhomogeneous fully saturated cohesive soil in undrained condition. The ultimate pullout load has been found out by using numerical lower bound finite element analysis with linear programming. The undrained pullout capacity of anchor plate of width B is determined for different embedment ratios (H/B) varying from 3 to 7 and various inclination of anchor plates ranging from $0^{\circ}$ to $90^{\circ}$ with an interval of $15^{\circ}$. In case of anisotropic fully saturated clay the variation of cohesion with direction has been considered by varying the ratio of the cohesion along vertical direction ($c_v$) to the cohesion along horizontal direction ($c_h$). In case of nonhomogeneous clay the cohesion of the undrained clay has been considered to be increased with depth below ground surface keeping $c_v/c_h=1$. The results are presented in terms of pullout capacity factor ($F_{c0}=p_u/c_H$) where $p_u$ is the ultimate pullout stress along the anchor plate at failure and $c_H$ is the cohesion in horizontal direction at the level of the middle point of the anchor plate. It is observed that the pullout capacity factor increases with an increase in anisotropic cohesion ratio ($c_v/c_h$) whereas the pullout capacity factor decreases with an increase in undrained cohesion of the soil with depth.

First Korean case of factor V Leiden mutation in pregnant woman with a history of recurrent pregnancy loss

  • Han, Sung Hee;Seo, Jung Jae;Kim, Eun Seol;Ryu, Jae Song;Hong, Seong Hyeon;Hwang, Seung Yong
    • Journal of Genetic Medicine
    • /
    • v.16 no.1
    • /
    • pp.23-26
    • /
    • 2019
  • Thrombophilia refers to inherited or acquired hemostatic disorders that result in a predisposition to blood clot formation. When combined with the hypercoagulable state that is characteristic of pregnancy, there is an increased risk of severe and recurrent pregnancy complications. Activated protein C resistance caused by factor V Leiden (FVL) mutation is known to be the most common cause of inherited thrombophilia in Caucasian population. FVL mutation has been related to pregnancy complications associated with hypercoagulation, e.g. miscarriage, intrauterine fetal demise, placental abruption, and intrauterine growth retardation. Although the FVL mutation is easily detected using molecular DNA techniques, patients who are heterozygous for this disorder often remain asymptomatic until they develop a concurrent prothrombotic condition. Because there are potentially serious effects of FVL mutation for pregnancy, and because effective treatment strategies exist, early detection and treatment of this condition might be considered.

Wind load characteristics and effects of 1000kV UHV substation frame based on HFFB

  • Hao Tang;Fanghui Li;Xudong Zhi;Jie Zhao
    • Wind and Structures
    • /
    • v.38 no.6
    • /
    • pp.477-492
    • /
    • 2024
  • This study presents a comprehensive investigation of wind load characteristics and wind-induced responses associated with different wind incidence angles and terrains of the 1000kV UHV substation frame. High-frequency force balance (HFFB) force measurement wind tunnel tests are conducted on the overall and segment models to characterize wind loads characteristics such as the aerodynamic force coefficients and the shape factors. The most unfavorable wind incidence angles and terrains for aerodynamic characteristics are obtained. A finite element model of the substation frame is built to determine the wind-induced response characters based on the aerodynamic force coefficients and bottom forces of the segment models. The mean and root mean square (RMS) values of displacement responses at different heights of the frame structure are compared and analyzed. The influence of wind incidence angle and terrains on wind-induced responses is also examined. The displacement responses in terms of the crest factor method are subsequently transformed into dynamic response factors. The recommended values of dynamic response factors at four typical heights have been proposed to provide a reference for the wind resistance design of such structures.

A Guide to Selection of Voltages for Low Voltage Motors and Case Study (저압전동기 정격전압 선정기준 및 사례 연구)

  • Lee, Min-Young;Chang, Choong-Koo;Suh, Sang-Jin
    • Electric Engineers Magazine
    • /
    • v.235 no.3
    • /
    • pp.35-41
    • /
    • 2002
  • The selection of voltage is one of the most significant factors in the design of power system for industrial plant. It is a major factor in determining over-all system cost, flexibility, and ease of future expansioin. This paper presents the study results on the selection of economic voltage for low voltage motors.

  • PDF

Temperature Dependence of the Rate Constants of the VV Energy Exchange for N$_2$(v=1)+O$_2$(v=0)$\rightarrow$N$_2$(v=0)+O$_2$(v=1)

  • Ree, Jong-Baik;Chung, Keun-Ho;Kim, Hae-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.3
    • /
    • pp.241-245
    • /
    • 1986
  • The vibration-vibration energy exchange of $N_2(v=1)+O_2(v=0){\to}N_2(v=0)+O_2(v=1)$ has been investigated, in particular, at low temperatures. The energy exchange rate constants are calculated by use of the solution of the time-dependent Schrodinger equation with the interaction potential of the colliding molecule as a perturbation term. The predicted rate constants are significantly agree with a experimental values in the range of 295∼$90^{\circ}K$. The consideration of the VV-VT coupling decreases the predicted pure VV energy exchange value by a factor of ∼2. When the collision frequency correction is introduced, the VV-VT rate constant is consistent with the observed value in the liquid phase. The consideration of the population of the rotational energy level increases the VV-VT value significantly.