• Title/Summary/Keyword: V-계수

Search Result 1,157, Processing Time 0.027 seconds

Computational Fluid Analysis for the Otter Boards - 4 . Efficiency Analysis of the Cambered Otter Boards for the Vortex Generators - (전개판에 대한 수직해법 - 4 . 과발생기에 따른 만곡형전개판의 성능분석 -)

  • 고관서
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.4
    • /
    • pp.286-292
    • /
    • 1991
  • The authors propose to use the vortex generators in order to improve of the efficiency for the cambered otter boards. The equipments and testing method of this model test was the same as the previous report. This study was tested for 6 models such as the single cambered, the V-shaped cambered and the slotted cambered otter board without and with vortex generators. The results obtained are as follows: \circled1 C sub(L) of the single cambered model otter board with vortex generators was increased about 10% in comparison with that of model without vortex generators, C sub(D) decreased 2%, and L/D increased 5~20%. \circled2 L/D of the V-shaped cambered model otter board with vortex generators was increased 10~20% in comparison with that of model without vortex generators. \circled3 C sub(L) of the two slotted cambered model otter board with vortex generators was increased about 20% within an angle of attack 25$^{\circ}$ in comparison with that of without vortex generators, C sub(D) increased 5~20%, and L/D was higher than prototype within an angle of attack 20$^{\circ}$. \circled4 The separation point of the model otter boards with vortex generators was removed back ward a little in comparison with that of the model without vortex generators. \circled5 Flow speed difference of the back side to the front side of model otter boards with vortex generators was increased a little in comparison with that of the models without vortex generators. \circled6 The size of separation zone in case of the model otter boards with vortex generators was decreased about 10% in comparison with that of the models without vortex generators.

  • PDF

Determination of the Effective Energy of X-Ray Beam Using Optically Stimulated Luminescent nanoDot Dosimeters (광자극형광나노닷선량계를 사용한 X선 빔의 유효에너지 결정)

  • Kim, Jongeon;Lee, Sanghun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.375-379
    • /
    • 2015
  • The purpose of this study is to determine the effective energy of a polyenegetic X-ray beam. The half value layer(HVL) of aluminum for 80 kVp X-ray beam was measured by using optically stimulated luminescent nanoDot dosimeters(OSLnDs). The linear attenuation coefficient(${\mu}$) was calculated using the measured HVL. And the mass attenuation coefficient(${\mu}/{\rho}$) was obtained by dividing the linear attenuation coefficient by the density(${\rho}$) of aluminum. The effective energy($E_{eff}$) of the obtained mass attenuation coefficient was determined using data of the X-ray mass attenuation coefficients for photon energies of aluminum given by National Institute of Standards and Technology(NIST). As a result, the HVL value is 2.262 mmAl. The ${\mu}$ value is $3.06cm^{-1}$. The ${\mu}/{\rho}$ value is $1.114cm^2/g$. And the $E_{eff}$ value was determined at 29.79 keV.

Effect of V$_2$O$_5$ Addition on Microwave Dielectric Properties of (Zr$_{0.8}$,Sn$_{0.2}$)TiO$_4$ (V$_2$O$_5$의 첨가가 (Zr$_{0.8}$,Sn$_{0.2}$)TiO$_4$의 마이크로파 유전특성에 미치는 영향)

  • 이경호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 2001
  • The effect of $V_2O_5$, a donor-type dopant on the degradation of quality factor of ($Zr_{0.8}, Sn_{0.2})TiO_4$was compared with Ta$_2$O$_{5}$ doped ($Zr_{0.8}, Sn_{0.2})TiO_4$ in terms of microstructure, electrical conductivity, and oxidation state of the dopant. It is well known that the addition of the donor type species such as $Ta_2O_5,Nb_2O_5, Sb_2O_5, WO_{3}$, increases the quality factor of ($Zr_{0.8}, Sn_{0.2})TiO_4$due to decrease the oxygen vacancy concentration. Unlike other dopants, however, the addition of $V_2O_5$ decreased the quality factor. The degradation of quality factor of ($Zr_{0.8}, Sn_{0.2})TiO_4$was resulted from the formation of grain boundary phase and $V_2O_5$rich fiber shaped secondary phase, and the increasing the oxygen vacancy concentration due to unstability of oxidation state of vanadium ions in ($Zr_{0.8}, Sn_{0.2})TiO_4$ceramic.c.

  • PDF

A Study of Dosimetric Characteristics of a Diamond Detector for Small Field Photon Beams (광자선 소조사면에 대한 다이아몬드 검출기의 선량특성에 관한 연구)

  • Loh, John-K.;Park, Sung-Y.;Shin, Dong-O.;Kwon, Soo-I.;Lee, Kil-D.;Kim, Woo-C.;Cho, Young-K.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.195-203
    • /
    • 1999
  • It is difficult to determine dosimetric characteristics for small field photon beams since such small fields do not achieve complete lateral electronic equilibrium and have steep dose gradients. Dosimetric characteristics of small field 4, 6, and 10 MeV photon beams have been measured in water with a diamond detector and compared to measurements using small volume cylindrical and plane parallel ionization chambers. Percent depth dose (PDD) and beam profiles for 6 and 10 MeV photon beams were measured with diamond detector and cylindrical ion chamber for small fields ranging from $1{\times}1\;to\;4{\times}4cm^2$. Total scatter factors($S_{c,p}$) for 4, 6, and 10 MeV photon beams were measured with diamond detector, cylindrical and plane parallel ion chambers for small fields ranging from $1{\times}1\;to\;4{\times}4cm^2$. The $S_{c,p}$ factors obtained with three detectors for 4, 6, and 10 MeV photon beams agreed well ($\pm1.2%$) for field sizes greater than $2{\times}2,\;2.5{\times}2.5,\;and\;3{\times}3\;cm^2$, respectively. For smaller field sizes, the cylindrical and plane parallel ionization chambers measure a smaller $S_{c,p}$ factor, as a result of the steep dose gradients across their sensitive volumes. The PDD values obtained with diamond detector and cylindrical ionization chamber for 6 and 10MeV photon beams agreed well ($\pm1.5%$) for field sizes greater than $4{\times}4\;cm^2$. For smaller field sizes, diamond detector produced a depth-dose curve which had a significantly shallower falloff than that obtained from the measurements of relative depth-dose with a cylindrical ionization chamber. For the measurements of beam profiles, a distortion in terms of broadened penumbra was observed with a cylindrical ionization chamber since diamond detector exhibited higher spatial resolution. The diamond detector with small sensitive volume, near water equivalent, and high spatial resolution is suitable detector compared to ionization chambers for the measurements of small field photon beams.

  • PDF

A study on the dither-stripping with dither motion sensor of a ring laser gyroscope (링레이저 자이로의 몸체진동 검출센서를 이용한 dither-stripping 연구)

  • Sim, Gyu Min;Im, Hu Jang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.63-71
    • /
    • 2003
  • In this paper we dicuss the dither-stripping methods by V-F(voltage to frequency) conversion of the output of angular velocity sensor which is for detecting the dither motion of the ring laser cavity. In this case, it is very important to evaluate the pulse-to-pulse scale factor between the ring lase output pulse and V-F output pulse, and also to compensate the zero offset of the V-F output pulse. In the case of the dither-stripping by the V-F conversion of angular velocity sensor output, there is a big angle uncertainty in the process of compensating the zero offset due to the dither noise for compensating the V-F output. By differential, the phase of the V-F output is changed. So, to compensate it, we change 90deg of the phase of angular velocity sensor output and delay half sampling time of the phase of ring laser output in advance. In this case the pulse-to-pulse scale factor can be evaluated by the standard deviation of each pulse. We can get the good result of the dither-stripping output by this angle differential method.

Derivation of Roughness Coefficient Relationships Using Field Data in Vegetated Rivers (식생하천의 현장자료를 이용한 조도계수 관계식 유도)

  • Lee, Jong-Seok;Julien, Pierre Y.;Kim, Jae-Hoon;Lee, Tae-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.2
    • /
    • pp.137-149
    • /
    • 2012
  • Field measurements of resistance to flow are analyzed for 739 rivers vegetated with grass (281 channels), shrubs (150 channels) and trees (308 channels). The measured distribution of Manning roughness coefficients ranges from 0.015~0.250 for grass, 0.016~0.250 for shrubs, 0.018~0.310 for trees. Significant trends are obtained between Darcy-Weisbach (or Manning roughness coefficients) and flow discharge, friction slope, and relative submergence. The regression equations for Darcy-Weisbach and Manning roughness coefficients in vegetated rivers are: $f_{veg}=0.436Q^{-0.363}$, $f_{veg}=3.305S_f^{0.508}$, and $n_{veg}=0.061Q^{-0.124}$, $n_{veg}=0.144S_f^{0.199}$, $V=5.3(h/d_{50})^{1/8.3}{\sqrt{ghS_f}}$, $\sqrt{8/f}(=V/u*)=5.75log(5h/d_{50})$, respectively. These semi-empirical relationships should be useful for hydraulic engineering practice.

Efficiency Calibration of HPGe Detector in Normal ana Coincidence Mode for the Determination of Prompt Gamma-ray (즉발감마선 측정을 위한 HPGe 검출기의 전계수 또는 동시계수모드에서의 광대역 계측효율 보정)

  • 송병철;박용준;지광용
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy(NIPS) system measures the prompt gamma-ray emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many element in either solid or liquid wastes. In this study, the full-energy-peak (FEP) efficiency calibration for a HPGe detector was constructed in the ${\gamma}$-ray energy range from 80 keV to 8 MeV, using $^{l33}$Ba and >TEX>$^{152}Eu$ RI sources and $ ^{35}Cl(n, ${\gamma}$)^{36}Cl$ thermal neutron captured reaction. The FEP efficiency curve for the higher energies using the $^{35}Cl(n, ${\gamma}$)^{36}Cl$ reaction was normalized with the curve obtained from the RI sources, since the accurate activity of its prompt ${\gamma}$-ray is unknown. The average thermal neutron flux was theoretically calculated using the FEP efficiency curve for the KCl standard solutions. The NIPS system equipped with a ${\gamma}$-${\gamma}$ coincidence setup with two n-type coaxial HPGe detectors was considered in order to reduce the interfering ${\gamma}$-ray background. The FEP efficiency curve for the ${\gamma}$-${\gamma}$ coincidence system was also obtained for full energy range. The performance of the normal and coincidence NIPS system was tested by comparing signal-to-noise ratio in each mode using the reference sample.e.

  • PDF

Three-Dimensional Virtual Crack Closure Technique Based on Anisoparametric Model for Stress Intensity Factors of Patch Repaired Plates with Cracks at Notches (접착 보강된 노치 균열판의 응력확대계수 산정을 위한 비등매개변수 모델 기반의 3차원 가상균열닫힘법)

  • Ahn, Jae-Seok;Woo, Kwang-Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1A
    • /
    • pp.39-48
    • /
    • 2012
  • This study deals with numerical determination of stress intensity factors of adhesively patch-repaired plates with cracks at V-shaped or semicircular notches. The p-convergent anisoparametric model are considered and then three-dimensional virtual crack closure technique is presented using formulations of anisoparametric elements. In assumed displacement fields of an element, strain-displacement relations and three-dimensional constitutive equations are derived with three-dimensional hierarchical shape functions expanded from one-dimensional Lobatto functions. Transfinite mapping technique is used to represent a circular boundary. The present model provides accuracy and simplicity in terms of stress concentration factor, stress distribution, the number of degrees of freedom, and non-dimensional stress intensity factor as compared with previous works in literatures. Stress intensity factors obtained by the three-dimensional virtual crack closure technique are estimated with respect to the variation of width of finite plate, radius of notch root, angular inclination of V-shaped notch, and crack length.

A study on the sliding rigid indentor over the viscoelastic layer supported by the elastic half-space (탄성체로 기대된 점잔성체층에서의 강성체의 운동해석)

  • Nam, J. W.
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.56-63
    • /
    • 1983
  • 강성체로된 견인물체가 탄성무한경면으로 지지된 점탄성층 위를 미끄러져 갈 때 접촉구간에서의 압력분포와 마찰 특성을 고찰하였다. 즉, 접촉구간에서의 강성체의 모양과 압력분포에 관한 적분 방정식을 구하고, 점탄성층의 두께가 접촉구간에 비하여 충분히 두꺼울 때 압력분포와 마찰계 수의 근사해를 구하였다. 압력분포의 모양은 점탄성층의 물성을 표시하는 지수값, 즉 .alpha.<1/2, .alpha.=1/2, .alpha.>1/2에 따라서 크게 다르다. 한편, 수치해석에 의하면 마찰 계수에 대한 근 사해는 강성체의 미끄럼 속도, 점탄성 층의 두께, 탄성체의 영율 (E$_{o}$ )과 점탄성층의 시효 성탄성계수 (E$_{v}$ )의 차, 즉 E$_{o}$ /E$_{v}$ 에 따라 변화함을 알 수 있다. 즉, 탄성체가 점탄성층에 비하여 딱딱하면 할수록, 또 강성체 속도가 느리면 느릴수록 마찰계수는 작아진다. 그리고 불성의 지수(.alpha.)가 커지면 커질수록 근사해의 수렵 속도는 느려지게 되고 지 수(.alpha.)가 1에 가까워지면 점탄성층의 탄성효과는 점성효과에 비하여 거의 무시할 수 있으며 근사해는 의미가 없어지게 된다.

  • PDF

Review of lane utilization factor in KHCM (한국 도로용량편람의 차로이용계수에 대한 고찰)

  • 정회빈
    • Proceedings of the KOR-KST Conference
    • /
    • 1999.10a
    • /
    • pp.229-234
    • /
    • 1999
  • 본 논문은 한국도로용량편람의 신호교차로 용량분석에서 차로이용계수를 적용하는 방법을 신호교차로 용량분석의 절차와 이동류 구분 측면에서 살펴보았다. 고찰한 결과 차로이용계수의 개선방향은 다음과 같다. 첫째, v/c 비에 따라 차로이용계수를 적용함으로써, 반복계산이 불필요하게 발생한다. 따라서 편람 개정시 이러한 반복계산을 없애는 값을 산정해야 한다. 둘째, 차로이용계수는 직진 전용차로를 통과하는 직진교통량에 대해서만 적용해야 한다. 실제 현장에서 교통량 조사 상황을 고려해보면, 상당히 불합리한 값을 도출한 것이다. 따라서 차로이용계수를 적용하는 이동류를 정확히 설명하고 그 문제점을 분명히 해야 한다. 셋째, 차로이용계수는 직진 이동류에 대해서만 있다. 우리 나라 전역에 있는 소규모 교차로를 고려해 볼 때, 차로이용계수는 다양한 차로군(lane group)에 대하여 추가적으로 조사연구가 필요하다.

  • PDF