• Title/Summary/Keyword: V 모델

Search Result 1,402, Processing Time 0.041 seconds

Identification of Excitation System Model Parameters from the Test of Switching from MVR Mode to AVR Mode (MVR모드에서 AVR모드로의 절환에 의한 여자계 모델정수 결정)

  • Kim, Dong-Joon;Moon, Yung-Hwan;Choi, Kyung-Sun;Lyu, Seung-Hhon;Song, Seok-Ha;Lee, Heung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.91-94
    • /
    • 1996
  • A simulation procedure was developed for identifying Yungnam unit 2 excitation model parameters to improve the accuracy of stability simulation of KEPCO. First, generator model parameters are derived by using modified load rejection technique from measured load rejection test. For identifying excitation model parameters, switch was changed from MVR mode to AVR mode in Yungnam unit 2 excitation system instead of applying to a small step to the voltage reference($V_{ref}$) because of saving time and efforts, assuming the test result would show coincided result with applying to a small step to the $V_{ref}$. However, it was found that the response of switching from MVR to AVR is greatly different from it of applying small signal to the $V_{ref}$. A simulation procedure was needed to take into accounts of real AVR component status before and after switching from MVR to AVR. This paper reports the procedure which duplicated the measured response and addresses the merits of this test on conventional AVR step test.

  • PDF

Development of Contact System in 460[V]/225[A]/50[kA] Molded Case Circuit Breaker (460[V]/225[A]/50[kA] 한류형 배선용 차단기 소호부 개발)

  • 최영길;구태근;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.137-144
    • /
    • 2002
  • Low voltage circuit breakers which interrupt rapidly and raise the reliability of power supply are widely used in power distribution systems. In the paper, it has been investigated how much interrupting capability is improved by correcting the shape of the contact system in molded case circuit breaker(below MCCB), especially arc runner. Prior to the interrupting testing, it is necessary for the optimum design to analyze electromagnetic forces on the contact system generated by current and flux density. This paper presents both our computational analysis and test results on contact system in MCCB.

Stripping Method of Ring Laser Gyroscope Based on Measurement Model of Dither Motion (디더 운동 측정치 모델 기반 링레이저 자이로 스트리핑 방법)

  • Kim, Cheon-Joong;Shim, Kyu-Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.531-536
    • /
    • 2014
  • There are trapping and stripping methods as the technique to remove the dither motion from RLG(Ring Laser Gyro) output. V/F converter output of angular sensor to measure the dither motion is used in stripping method. But bias and scale factor error is always included in V/F converter output and is a critical limiting factor for the wide application of stripping method to RLG. Therefore there have been many researches to solve this problem. The method to accurately estimate the bias and scale factor error of V/F converter using measurements of the angular sensor acquired at data sampling rate of INS is presented in this paper. To this end, stripping technique based on model of dither motion is newly applied.

Dielectric Recovery Characteristics between Poles of 800kV Model Interrupter -I. Effects or separation between Moving Main Contact and Moving Arcing Contact- (800kV 모델차단부의 극간 절연회복특성 -I. 가동주접점과 가동아크접점간 이격거리의 변화에 대한 영향분석-)

  • Shin, Y.J.;Park, K.Y.;Chang, K.C.;Song, K.D.;Jeong, J.K.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.270-273
    • /
    • 1994
  • The capacitive current breaking capability as well as the short circuit current breaking capability is a very important factor in the performance of a circuit breaker. The dielectric recovery capability between poles should be considered in the desist of a circuit breaker because approximately two times of the maximum power system voltage might be applied between poles after the capacitive current be interrupted. The electric field and flow field analyses were utilized in the calculation of dielectric recovery characteristics between poles of 800kV model interrupter. The results show that the separation between moving main contact and moving arcing contact will affect to decrease significantly the electric field strength of a moving arcing contact and an insulation cover, to increase slightly the electric field strength of a fixed arcing contact and to decrease consequently the dielectric recovery capability between poles of the interrupter.

  • PDF

The Effects of Nerve Growth Factor Expression of Central Nerve System by Environmental Enrichment and Peripheral Nerve Electrical Stimulation in Brain Ischemia Model Rats (뇌졸중 유발 백서모델에서 환경강화와 말초신경전기자극이 중추신경계의 신경성장인자에 미치는 영향)

  • Kim, Sa-Youl;Kim, Eun-Jung;Kim, Gye-Yeop
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.4
    • /
    • pp.33-41
    • /
    • 2007
  • Purpose: To investigate environmental enrichment and nerve stimulation follows in application times with the change of BDNF & Trk-B receptor in the motor cortex and spinal cord. Methods: Experimental groups were divided into the five groups. Group I: normal control group, Group II: experiment control group, Group III: sciatic never electrical stimulation after MCAO, Group IV: application of only environmental enrichment after MCAO, Group V: never electrical stimulation with environmental enrichment after MCAO. Histologic observation and coronal sections were processed individually in goat polyclonal antibody phosphorylated BDNF and rabbit polyclonal antibody Trk-B receptor. Results: In immunohistochemistric response of BDNF and Trk-B, group II were showed that lower response effect at postischemic 1 days, 3 days, and 7 days. Group V were showed that increase response effect at postischemic 3 days, 7 days and 14 days. Specially showed that the most response effect at postischemic 14 days. In neurobehavioral assessment, group V were significantly difference from other groups on between-subject effects. Conclusion: The above results suggest that combined environmental enrichment with peripheral nerve electrical stimulation in focal ischemic brain injury were more improved that the change of BDNF & Trk-B receptor expression than non treatment.

  • PDF

Comparison Study of Prediction Models for Hot Deformation Behavior of Tool Steel (공구강의 고온 변형 거동 예측을 위한 모델 비교 연구)

  • Kim, Keunhak;Park, Dongsung;Jun, Joong-Hwan;Lee, Min-Ha;Lee, Seok-Jae
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.31 no.4
    • /
    • pp.180-186
    • /
    • 2018
  • High temperature flow behaviors of Fe-Cr-Mo-V-W-C tool steel were investigated using isothermal compression tests on a Gleeble simulator. The compressive test temperature was varied from 850 to $1,150^{\circ}C$ with the strain rate ranges of 0.05 and $10s^{-1}$. The maximum height reduction was 45%. The dynamic softening related to the dynamic recrystallization was observed during hot deformation. The constitutive model based on Arrhenius-typed equation with the Zener-Hollomon parameter was proposed to simulate the hot deformation behavior of Fe-Cr-Mo-V-W-C steel. An artificial neural network (ANN) model was also developed to compare with the constitutive model. It was concluded that the ANN model showed more accurate prediction compared with the constitutive model for describing the hot compressive behavior of Fe-Cr-Mo-V-W-C steel.

Voice/Tone Warning System Design for Military Aircraft (군용 항공기를 위한 음성/톤 경고 시스템 설계)

  • Na, Hana;Kim, Do Gyun
    • Journal of Platform Technology
    • /
    • v.9 no.3
    • /
    • pp.24-35
    • /
    • 2021
  • High-speed military aircraft shall be able to identify and resolve enemy threats or internal component defects with survival equipment and warning systems to minimize casualties. Warning system is divided into visual method with symbolic display and auditory method with communication equipment, which is superior in that they it has a short response time and does not cause pilot confusion by listening to simple messages. Thus, this paper suggested and evaluated effective design methods of voice/tone warning systems for military aircraft based on a life cycle perspective. Since military aircraft is safety-sensitive, priorities and three properties(Inhibitible, Interruptible, and Deactivatable) were applied to each warning to reflect criticality and urgency. As a result, we confirmed that it took 40ms to play the voice warnings, satisfying all requirements through V model-based development and testing, and improving product reliability.

A Study on Management Functions of Intelligent Reflectors Environment (지능형 반사경의 관리 기능 연구)

  • Kang-Hyun Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.3
    • /
    • pp.433-440
    • /
    • 2023
  • When the reflector is hit by a vehicle or returned by a storm, an event is generated by the impact sensor and a trigger is operated. The trigger processing algorithm of this paper compares the X, Y, and Z values of the gyro sensor with the registered values and proposes to drive them to the original values by the operation of the 3-axis driving motor. And by recognizing the vehicle license plate, if the vehicle is stolen or a social problem, information is provided to the police operation network. When the reflector is stolen or moved, it has a registered GPS value, so it operates the theft monitoring function to process it.

Development of a Small Current Breaking Prediction Technology in such a complex GCB as a Dual motion GCB (양방향 구동 차단기와 같은 복잡한 차단기의 소전류 차단 평가기술 개발)

  • Lee, Hyeong-Goo;Song, Tae-Hun;Kim, Yeon-Pung;Choi, Byeong-Hwa;Yun, Ja-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1796-1798
    • /
    • 2004
  • 기존의 단방향 차단기 소전류 차단성능 해석에서는 해석의 편의를 위해 실제 차단기의 고정부(고정아크접점과 피스톤)를 움직이게 하고 가동부(퍼퍼 실린더 노즐 등)를 고정시켜 놓고 해석을 하였다. 기존 차단기에서는 이런 식으로 해석을 하여도 아무런 문제가 발생하지 않았으나 이번 당사 모델인 550kV 50kA 1점절 차단기는 차단성능 향상을 위해 양방향으로 구동이 이루어지고 있어서 기존 방식으로 해석을 하는 것이 거의 불가능하다. 따라서 이번 연구에서는 상용프로그램인 PHOENICS를 이용하여 실제 차단기와 마찬가지로 가동부가 움직이도록 모의하는 방법을 개발하여 550kV 1점절 차단기의 소전류 차단성능을 평가하였으며, 앞으로 개발될 모든 복잡한 형태의 차단기도 쉽게 해석할 수 있는 계기를 마련하였다.

  • PDF

Modeling and Analysis of 154kV Superconducting Cable (154kV 초전도케이블 모델링과 해석)

  • Choi, Jong-Kee;Jung, Chae-Gyun;Yang, Beyong-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.367_368
    • /
    • 2009
  • 초전도 전력케이블은 기존 케이블에 비해 많은 전력을 공급할 수 있기 때문에 노후 전력케이블 교체시 대용량 송전을 가능하게 하는 대안으로 관심이 많아지고 있다. 초전도 케이블은 전기적인 특성이나 냉각시스템을 필요로 하는 등 기존 케이블과 다른 많은 특성을 가지고 있기 때문에 실계통에 투입하기 이전에 케이을 보호 등 새롭게 검토 해야할 사안들이 있다. 이를 위해서는 초전도 전력케이블 모델 및 이를 이용한 전산모의가 필수적이지만, 새로운 요소인만큼 이에 관한 자료들이 많지 않은 실정이다. 본 논문에서는 전력계통 과도해석에 널리 사용되는 EMTP를 이용하여 초전도 전력케이블을 모델링하고 전압-전류 특성을 모의한 사례를 제시하고자 한다.

  • PDF