• 제목/요약/키워드: Uv Camera

검색결과 64건 처리시간 0.031초

고전압 방전 검출용 자외선 코로나 카메라 개발 및 방전 이미지 분석 (Analysis of Image and Development of UV Corona Camera for High-Voltage Discharge Detection)

  • 김영석;송길목;방선배;김종민;최명일
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.69-74
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV image. UV camera developed a $6.4[^{\circ}]{\times}4.8[^{\circ}]$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. UV camera to measure the discharge count and the UV image was developed, compared with a commercial camera, there was no significant difference. In salt spray environments breakdown voltage was lower than the normal state, thereby discharging the image was rapidly growing phenomenon.

염수 환경 열화 상태를 모의한 절연애자의 자외선 코로나 특성 분석 (Analysis of Properties of UV Corona on Insulator in Salt Water Environments)

  • 김영석;최명일;김종민;방선배;송길목;이명준;이우창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1590-1591
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV camera. UV camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The UV camera was developed and measured using a UV image, as applied voltage increased ultraviolet images of the phenomenon could be obtained. And we investigated properties of UV corona image on insulator in salt water environments. From the results, the breakdown voltage was decreased and UV images were taken at low voltages and the UV image is rapidly increased with increasing High voltage.

  • PDF

투과율 향상 UV 필터와 IR 모듈을 이용한 자외선-적외선(UV-IR) 카메라 개발 (Development of UV-IR Camera using IR Module and Improved UV Filter Transmittance)

  • 김영석;송길목;방선배;김종민;최명일;김우진
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.37-43
    • /
    • 2012
  • UV-IR diagnostic technology is being used for predictive maintenance of high voltage equipment together with IR-thermography and ultrasonic devices. In this paper, the UV-IR camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. UV-IR camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. In a distance of 5m with the UV-IR it is possible to detect partial discharge with a PD level of 2.5 pC and a RIV(Radio Influence Voltage) level of $3.6dB{\mu}V$.

자외선 카메라 개발을 위한 직류 연면방전 특성 (Characteristics of DC Surface Discharge for the Development of UV Camera)

  • 방만식;최재형;김우진;김영석;김상현
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.98-103
    • /
    • 2011
  • Recently, UV(ultra-violet rays) camera has attracted a great deal of interest from the view point of easy judgement in inspections and diagnoses of the safety of power equipment. Especilly, UV camera is applied the inspection of UV with corona discharge. One of the most important and difficult problems is the basic research of filter design, materials and corona discharge. In this paper, we will report on the UV generation, corona pulse count and the polarity effect of positive and negative DC surface discharge in air. Also, corona discharge characteristics are analyzed using prototype UV camera of Korea. UV generation and corona pulse count due to surface discharge in positive needle is higher than that of negative needle.

UV-IR 카메라를 이용한 전력설비 진단을 위한 전기 및 광학적 안전 기준 설정 연구 (A Study of Electrical and Optical Method of Safety Standards for diagnosis of Power Facility using UV-IR Camera)

  • 김영석;김종민;최명일;방선배;송길목;곽동순
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.54-61
    • /
    • 2013
  • UV-IR camera is being used for predictive maintenance of high voltage equipment together with measurement of temperature on localized heat and corona discharge. This paper was suggested the judgement method that is the discharge count, UV image pattern and discharge matching rate to apply the UV-IR camera on power facility. The discharge count method is counted by UV image pixel value. the UV image pattern method is determined by the UV image shape using neural network algorithm method, separated by Sunflower, Jellyfish, Ameba. The UV discharge matching is compare the breakdown the UV image size and measuring UV image size according to distance.

UV 투과율 향상 필터 기술을 이용한 전력설비 방전 검출용 자외선 코로나 카메라 개발 (Development of UV Corona Camera for the Detecting of Discharge on Power Facility using UV Transmittance Improvement Filter)

  • 김영석;최명일;김종민;방선배;송길목
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1656-1661
    • /
    • 2012
  • UV inspection technology is being used for predictive maintenance of power facility together with IR-thermography and ultrasonic devices. In this paper, the UV corona camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. The UV corona camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The transmission between 250 to 280nm was 11% ($12.5%{\times}88%{\times}98%$) by combing the transmission on absorption film, window and other filter(UG 5, nickel sulphate and so on). In a distance of 5m with the UV corona camera it is possible to detect partial discharge with a PD level of 2.5pC and a RIV level of $3.6dB{\mu}V$.

전력설비의 열화 진단을 위한 연면방전 모델에서의 코로나 방전 특성 분석 (The Analysis of Corona Discharge of Surface Flashover Model for Aging Diagnosis of Power Facility)

  • 방만식;최재형;김우진;김영석;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제24권4호
    • /
    • pp.314-318
    • /
    • 2011
  • Recently, ultrasound, infrared detector, V-I characteristic, gas analysis, UV (ultra-violet rays) camera etc. is used as inspections and diagnoses of the safety of power equipment. Especially, UV camera have attracted a great deal of interest from the view point of easy judgement. UV camera is used corona discharge. One of the most important and difficult problems to be solved filer design, materials and corona discharge. This paper is studied on the temperature characteristics, UV generation and shape analysis and corona pulse count according to the electrode distance and applied voltage. Also, Corona discharge characteristics in air are analyzed using prototype UV camera of Korea. UV generation due to surface discharge of AC is higher than that of DC.

UV 센서를 이용한 절연애자의 코로나 방전 측정 및 자외선 이미지의 비교 (Comparison of UV images and Measurement of the Corona Discharge from Insulators using the UV Sensor)

  • 김영석;최명일;김종민;방선배;송길목
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.899-904
    • /
    • 2011
  • Inspections and diagnoses of corona discharge are important in order to prevent electrical faults of external insulation in power systems. This paper studies a measurement of ultra-violet rays(UV) strength of corona discharges on insulators using a UV sensor with an optic lens. The data has been compared with the images of a UV camera. The UV sensor estimated that DC voltage needed to be set at 700V for accurate data analysis of the properties of UV detected during corona discharge. UV was generated at 60kV when the corona discharge occurred. UV strength and images of UV increased at a high voltage. The image area of the UV using a UV camera and the detection of UV using a UV sensor have shown, that the polymer insulator mounted on a live part must be checked when the applied voltage on the good polymer insulator is greater than 37.5% of its breakdown voltage.

엠보싱 공법에 의한 카메라 모듈용 광학렌즈 성형기법에 대한 연구 (Fabrication of the Imaging Lens for Mobile Camera using Embossing Method)

  • 이청희;진영수;노정은;김성화;장인철
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.79-83
    • /
    • 2007
  • We have developed a compact and cost-effective camera module on the basis of wafer-scale replication technology. A multiple-layered structure of several aspheric lenses in a mobile camera module is first assembled by bonding multiple glass-wafers on which 2-dimensional replica arrays of identical aspheric lenses are UV-embossed, followed by dicing the stacked wafers and packaging them with image sensor chips. We have demonstrated a VGA camera module fabricated by the wafer-scale replication processing with various UV-curable polymers having refractive indices between 1.4 and 1.6, and with three different glass-wafers of which both surfaces are embossed as aspheric lenses having 200 um sag-height and aspheric-coefficients of lens polynomials up to tenth-order. We have found that precise compensation in material shrinkage of the polymer materials is one of the most technical challenges, in order to achieve a higher resolution in wafer-scaled lenses for mobile camera modules.

  • PDF

오염물질에 따른 변압기부싱 모델의 기중 코로나 방전 특성 (Corona Discharge Characteristics of Transformer Bushing Model with Contaminnations in Air)

  • 방만식;김우진;김영석;김상현
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.91-96
    • /
    • 2012
  • The surface of bushing is contaminated with rain, dust, salt and others. A bushing with contaminations in air is serious problem in insulation. Therefore, it is important to understand the inspection and diagnoses of the safety. The ultra-violet rays(UV) camera has attracted interest from the view point of easy judgement. In this paper, we will report on the corona discharge characteristics of surface flashover model with contaminations in air. Also, UV images of discharge and corona pulse count in air are analyzed using prototype UV camera of Korea and a UV sensor with an optic lens. These results are studied at both AC and DC voltage under a non-uniform field.