• Title/Summary/Keyword: Utility cost

Search Result 497, Processing Time 0.027 seconds

The Study on Correlation between Traffic Accident Severity with Period and Cost of Treatment in Traffic Accident Outpatients Visiting a Korean Medicine Hospital (한방병원에 내원한 교통사고 외래환자에 있어서 사고규모와 치료기간 및 치료비용 간의 상관관계에 대한 연구)

  • Park, Ji-Yong;Hong, Nam-Jung;Lee, Min-Jung;Ahn, Ji-Hoon;Shin, You-Bin;Kim, Byung-Jung;Shin, Min-Geun;Ha, In-Hyuk;Lee, Jin-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.24 no.1
    • /
    • pp.65-76
    • /
    • 2014
  • Objectives The purpose of this study is to investigate the corelation between traffic accident severity and treatment period and cost by traffic accident. Methods Outpatients who visited Jaseng Korean medicine hospital traffic accident clinic were investigated by hospital computer system about period and cost of treatment. And we requested for repair cost of car, a sort of car groups and agreement date with car insurance company to insurance company. Therefore we could analysis statistical correlation of traffic accident severity (repair cost of car) with period of treatment, cost of treatment, number of treatment in same sort of car groups. For statistics, we used SPSS version 18.0 for windows. Results A significant positive correlation was found between traffic accident severity (repair cost of car) with repair cost of car, cost of treatment and number of treatment in semi-midsize car, midsize car group. But, any significant correlation wasn't found between traffic accident severity (repair cost of car) with repair cost of car, cost of treatment and number of treatment in small car, full-sized car group. In SUV (sport utility vehicle) car group some significant correlation was found, but it isn't between traffic accident severity (repair cost of car) with repair cost of car, cost of treatment and number of treatment. Conclusions It was found that traffic accident severity (repair cost of car) had an effect on cost of car, cost of treatment and number of treatment by statistical analysis. But, it was also suggested strongly that other factors like a cost of car and ages had an effect on them.

Effects of Commonality Strategy in Product Line Design on Social Welfare (제품군 디자인에서 공통속성의 활용이 사회적 효용에 미치는 영향)

  • Kim, Kil-Sun
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.33 no.3
    • /
    • pp.77-92
    • /
    • 2008
  • Commonality strategy is a popular design practice in designing a product line as it enables the firm cost saving and simplification in design, manufacturing, and distribution processes. However the issue of commonality has been mostly analyzed from a profit maximizing firm's perspective and, to our knowledge, there is no literature that deals with the issue from a different perspective. in this paper, we consider the issue of commonality strategy from a social welfare maximization perspective, and argue that commonality strategy used in designing of public goods can bring certain benefits not just for a firm but also for consumers, i.e., for society as a whole. While we assume certain cost saving in production process due to economies of scale under commonality strategy, we conceptualize two different effects of commonality strategy, utility effect due to cost saving and weighted-averaging effect, and show how these two effects interplay to determine the design of common attribute and desirability of commonality strategy. We also discuss how the implementation of commonality strategy differs under different objectives of a product line designer : social welfare and firm's profit maximization.

A Study on the Improvement of Profitability in the Marine Fish Culture Business (해수어류양식업의 수익성 제고방안)

  • 정신작;진상대
    • The Journal of Fisheries Business Administration
    • /
    • v.28 no.2
    • /
    • pp.39-66
    • /
    • 1997
  • The objective of this study is to suggest the improvement method of the profitability in our marine fish culture business. So I investigated the actual condition for aquaculture farms in South Sea coast by the question and actual survey. 1 recognized the following facts; 1) The marine floating netcage system are a great portion in two province - Kyeongnam and Cheunnam, 2) The rockfish are reared absolutely much more than the olive flounder, 3) The polyculture by various species are more carried out than the monoculture of the olive flounder or rockfish, etc. I analyzed the profitability in olive flounder monoculture, rockfish monoculture, olive flounder and rockfish polyculture, and rockfish polyculture taking turns year by year respectively. At a result I comfirmed that the net income to net sales was the highest in the olive flounder monoculture bacouse the olive flounder,s sale price was higher than rockfish price. But internal rate of return(IRR) and net present value(NPV) were high in the olive flounder and rockfish polyculture or the rockfish taking turns polyculture. The reasons were alttributed to their high utility of a netcage and to reduction of a capital cost. So, I suggest 1) to feed the bigger product in short term, 2) to reduction of a feed and seed cost, 3) to increase a survival rate of fish and 4) to enlarge production by highly utilizing a netcage. And I recognized that a aquaculture manager should make constantly an effort to gain more profit by rearing more good products and by reducing a production cost.

  • PDF

A Study on the Improvement of Subsidy Program for CHP Plant Connected with Capital Region District Heating System (수도권 지역난방연계 열병합발전소의 기반기금 지원과 개선방안)

  • 김창수;이창호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.97-103
    • /
    • 2004
  • CHP system supplies electricity and heating together with high efficiency. Current utility's CHP system uses electric power by itself and sells thermal energy to KDHC(Korea District Heating Corporation). CHP's operation cost except sales revenue of heating was covered by the sale revenue of electricity. Thus Electric generation cost in district Heating CHP system has close relationship with the level of heating price. However, after the restructuring of electricity industry, the operation cost could not be covered by sales revenue of heating and electricity. This loss was compensated by energy subsidy program in the electric power industry infrastructure fund. This paper suggests reasonable evaluation and improvement methods of the loss calculation of CHP system utilizing the infrastructure fund efficiency In terms of the direction of support by the fund, it provides the methods to prevent inefficient operation through setting up the upper limit of subsidy and to improve the loss calculation. Moreover, it suggest fixed rate support by heating supply level and reducing subsidy gradually for an efficient operation of CHP system.

A Study on Design of Home Energy Management System to Induce Price Responsive Demand Response to Real Time Pricing of Smart Grid (스마트그리드 실시간요금과 연동되는 수요반응을 유도하기 위한 HEMS 설계에 관한 연구)

  • Kang, Dong-Joo;Park, Sun-Joo;Choi, Soo-Jung;Han, Seong-Jae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.39-49
    • /
    • 2011
  • Smart Grid has two main objectives on both supply and demand aspects which are to distribute the renewable energy sources on supply side and to develop realtime price responses on demand side. Renewable energy does not consume fossil fuels, therefore it improves the eco-friendliness and saves the cost of power system operation at the same time. Demand response increases the flexibility of the power system by mitigating the fluctuation from renewable energies, and reduces the capacity investment cost by shedding the peak load to off-peak periods. Currently Smart Grid technologies mainly focus on energy monitoring and display services but it has been proved that enabling technologies can induce the higher demand responses through many pilot projects in USA. On this context, this paper provides a price responsive algorithm for HEMS (home energy management system) on the real time pricing environment. This paper identifies the demand response as a core function of HEMS and classifies the demand into 3 categories of fixed, transferable, and realtime responsive loads which are coordinated and operated for the utility maximization or cost minimization with the optimal usage combination of three kinds of demand.

Energy and Economic Analysis of Heat Recovery Cogeneration Loop Integrated with Heat Pump System by Detailed Building Energy Simulation (건물 에너지 상세 해석을 통한 소형 열병합 발전 및 히트펌프 복합 시스템의 경제성 분석)

  • Seo, Dong-Hyun;Koh, Jae-Yoon;Park, Yool
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.71-78
    • /
    • 2009
  • Up until recently, the energy and the economic analysis of a cogeneration system have been implemented by a manual calculation that is based on monthly thermal loads of buildings. In this study, a cogeneration system modeling validation with a detail building energy simulation, eQUEST, for a building energy and cost prediction has been implemented. By analyzing the hourly building electricity and thermal loads, it enables users to decide proper cogeneration system capacity and to estimate more accurate building energy consumption. eQUEST also verified the energy analysis when the heat pump system is integrated with the cogeneration system. The mechanical system configuration benefits from the high efficiency heat pump system while avoiding the building electricity demand increase. Economic analysis such as LCC (Life Cycle Cost) method is carried out to verify economical benefits of the system by applying actual utility rates of KEPCO(Korea Electricity Power COmpany) and KOGAS(KOrea GAS company).

A Study on Economic Methodology for Deriving Money Coefficients (금전계수 도출을 위한 경제학적 방법론 연구)

  • Min-Hee Back
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.111-118
    • /
    • 2023
  • The International Commission on Radiological Protection (ICRP) 103 recommends a cost-benefit analysis method as an auxiliary tool for scientific and rational decision-making for the principle of optimization of radiological protection. In order to conduct a cost-benefit analysis, the safety improvement of nuclear power by regulation must be measured and converted into monetary terms. The improvement of nuclear safety can be measured by reducing the radiation exposure dose of the people, and it is necessary to determine the coefficient to convert the radiation exposure dose into money. The monetary coefficient is calculated as the product of the statistical life value (VSL) and the nominal risk coefficient. In order to derive the monetary coefficient, the willingness to pay (WTP) can be estimated using the contingent valuation method (CVM), which quantifies the value of non-market goods by converting them into monetary units. WTP can be estimated based on the random utility model, which is the basic model for bivariate selection type conditional value measurement data. Statistical life value can be calculated using the estimated WTP and reduction in early mortality, and a monetary coefficient can be derived.

Development of Grid Connection Type Inverter for 30kW Wind Power Generation System (30kW급 발전시스템의 계통 연계형 인버터 개발)

  • Hahm, Nyeon-Kun;Kang, Seung-Ook;Kim, Yong-Joo;Han, Kyong-Hee;Ahn, Gyu-Bok;Song, Seung-Ho;Kim, Dong-Yong;Rho, Do-Hwan;Oh, Young-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.990-992
    • /
    • 2002
  • 30kW electrical power conversion system is delveloped for the variable speed wind turbine system. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and frequency of generator output vary according to the wind speed, a dc/dc boosting chopper is utilized to maintain constant dc link voltage. Grid connection type PWM inverter supply currents into the utility line by regulating the dc link voltage. The active power is controlled by q-axis current which the reactive power can be controlled by d-axis current reference change. The phase angle of utility voltage is detected using s/w PLL(Phased Locked Loop) in d-q synchronous reference frame. This scheme gives a low cost power solution for variable speed WECS.

  • PDF

A Study on Carbon Dioxide Removal Process Using Composite Membrane in DME Production Process (DME 생산공정에서 복합막을 이용한 이산화탄소 제거공정 전산모사)

  • Noh, Sang-Gyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4698-4706
    • /
    • 2014
  • In this study, the simulation was performed for the CO removal process using a composite membrane in DME production. The composite membrane, PEI-PDMS (polyetherimide- polydimethyl siloxane) manufactured by Airrane Co. Ltd., was used in the modeling through a commercial simulation design program, PRO/II with PROVISION 9.2 by Invensys. To simulate the process, the permeability constants of each of the pure component from Airrane Co. Ltd. were determined by regression analysis from the experimental data. The required separation membrane area and utility cost in the CO removal process were obtained using a chemical process simulator and composite membrane with a compatible permeability constant.

Combustion Stability for Utility Gas Turbines : Development of a Real-Time Assessment Software (발전용 가스터빈의 실시간 연소안정성 평가 소프트웨어 개발)

  • In, Byeung Goo;Song, Won Joon;Cha, Dong Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.306-315
    • /
    • 2017
  • This study introduces a software for real-time assessment of combustion stability for utility gas turbines. The software was written with LabView, and implemented the time-domain kurtosis as a parameter to proactively access the instantaneous combustion stability during operation of the industrial gas turbine. The simple time-domain assessment algorithm incorporated in the software is advantageous over conventional frequency-domain signal processing of dynamic pressure signal since it reduces the computational cost, thereby making the algorithm more appropriate for real-time monitoring of combustion stability. Benchmark data obtained from a model gas turbine combustor were used for the reproducibility test of the software. The assessment obtained from the software agreed well with previously published results, indicating that incorporation of the software could enhance the performance of systems monitoring the combustion stability for gas turbines during power generation.