• Title/Summary/Keyword: Utility cost

Search Result 493, Processing Time 0.033 seconds

A Study on the Inherent Defects in the eUCP Article 11 & Implication for the Revision (eUCP 11조의 잠재적 하자의 규명과 합리적 개정방안의 모색)

  • Kim, Ki-Sun
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.35
    • /
    • pp.41-69
    • /
    • 2007
  • This study analyzes some important implications for the forthcoming revision of eUCP through the methodology of expected utility maximization theory. The overall results are as follows. First, beneficiary with an initial wealth has a risk-averse utility in traditional letter of credit transaction, and he would be more risk-averse in eUCP transaction. Secondly, the beneficiary who has risk-averse utility will pay for the risk premium to reduce the risk of corruption of an electronic record by means of cost of loss reduction activities. Thirdly, the cost of loss reduction activities is represented by a convex cost function, Fourthly, a risk averse beneficiary pursues loss reducing activities to the point where the expected marginal product of loss reduction is less than its marginal cost. Fifthly, a more risk-averse eUCP beneficiary will always select a higher level of loss reduction as long as the effectiveness of loss reduction is certain. Sixthly, when the effectiveness of loss reduction is uncertain, the more risk-averse eUCP beneficiary does not necessarily choose a higher level of loss reducing activities. Finally, it would be more reasonable that eUCP Article 11 should protect eUCP beneficiary who pursues a higher level of loss reducing activities.

  • PDF

Analysis of importance by category for quantitative economic evaluation of multi-utility tunnel (공동구의 정량적 경제성 평가를 위한 항목별 중요도 분석)

  • Cho, Choong-yeun;Sim, Young-Jong;Kim, Hun-kyom;Lee, Pil-yoon;Lee, Min-jae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.119-130
    • /
    • 2018
  • The VE/LCC study on the existing multi-utility tunnel examined the economical feasibility of the collective area through the cost-benefit analysis of the ten major routes of Seoul for the benefit (7 items) and the cost (5 items) through quantitative methods. In this paper, we analyzed the economic efficiency of 61 sectors by adding 3 items (reduced traffic accident, reduced vehicle noise, social-economic loss). The reduced traffic accident item is an improvement of the traffic accident cost that can be saved by the implementation of the project, and the reduced vehicle noise item is an indicator of the amount of noise change caused by the implement of the business. Finally, the social-economic loss items represent the impact on the local economy due to the construction of the multi-utility tunnel. The amounts of the additional items were compared and items added in the open type and tunnel type multi-utility tunnel were analyzed for each analysis. Result on the analysis, it analyzed the items applied to the basic and detail models in the economic evaluation of the multi-utility tunnel design, and makes it possible to evaluate the economic efficiency more efficiently. The economic evaluation of the basic and detailed models including the items presented in this study will be often used in the design of the multi-utility tunnel design.

A Study on the Design Method and the Effect Analysis for the Introduction of the Integrated System Model of Individual Urban Utility Plants (에너지공급시설 및 환경기초시설의 복합화 방안 및 적용효과 분석)

  • Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.235-240
    • /
    • 2005
  • Recently urban utility plants in urban areas of Korea, such as energy supply systems, municipal waste incineration systems, sewage treatment systems and so on, have caused some critical troubles, for instance the insensitive response to the seasonal or daily variation of loads, the low system efficiency and inefficient use of energy because of the large-scale system located a great distance. Therefor the design method of optimal integrated system model of various urban utility plants proposed in this study suitably to the present situation of Korea. Also, the effect analysis for the introduction of compound utility plants was studied for a new town model on a 60,000 persons scale. As the results we found that the complex plant was superior to individual urban utility plant in side of the initial investment expenses, the operating cost and other reasons.

  • PDF

Study on a Scheme of Investment Considering Customer Interruption Cost in Power Distribution System (정전비용을 고려한 배전계통 설비의 투자 계획 수립 방안연구)

  • Chu, Cheol-Min;Kim, Jae-Chul;Lee, Tae-Hee;Moon, Jong-Fil
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.365-369
    • /
    • 2006
  • It is concentrated on a methodology to establish a scheme of investment on power distribution systems of components. This paper provides a methodology to estimate the scheme as using a customer interruption cost regarding reliability indices in power distribution systems. The proposed method basically uses the failure rate depending on time for explaining the deterioration of a component. Therefore, the theory of the sensitivity is used for deciding the precedence of the investment to consider an effect of each component's failure rate on the system reliability. After Estimating the sensitivity on component investment cost making incremental reliability level is produced by component's investment cost accumulated according to the precedence of the sensitivity. After that, the failure rate corresponding with reliability level on the curve of investment cost is used as producing the curve of customer interruption cost. Two curves have the crossing point that is proposed to acceptable reliability level for customer and utility. In this paper, the acceptable reliability level for customer with the utility is assessed to analyze customer interruption cost and sensitivity of reliability indices. In conclusion the result of investment based on this method is shown to the reliability level with two cost.

  • PDF

A Study on the Economical PQMS of the Utility Distribution Power System (전력회사 관점의 배전계통 경제형 PQM 시스템 구축방안)

  • Park, Yong-Up;Lee, Keon-Hang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1523-1529
    • /
    • 2010
  • This paper describes the distribution power system econimical PQMS(Power quality monitoring system) of Utility. Recently, the korea power quality standard has been established based on the IEC Std. By IEC Std., the power quality assessment point is measured in PCC(Point of common coupling). In this case, the utility has to construct PQM system in all customer PCC point and the PQ meter cost would be very high in order to acquire the suitable data. Also the distribution system would be encounter the communication overload problem due to the huge data. Accordingly the utilities could not apply to PQM system in the distribution power system by the cost and communication problem. In this paper, the proposed economical PQMS has the voltage and current signal reiteration function and FFT operation function is transferred the server. Also the voltage and current measurement channels are minimized by a classified substation construction.

A Modified EGEAS Model with Avoided Cost and the Optimization of Generation Expansion Plan (회피비용을 고려한 EGEAS 모형 개발과 전원개발계획의 최적화)

  • 이재관;홍성의
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.17 no.1
    • /
    • pp.117-117
    • /
    • 1992
  • Pubilc utility industries including the electric utility industry are facing a new stream of privatization com-petition with the private sector and deregulation. The necewssity to solve now and in the future power supply and demand problems has been increasing through the sophisticated generation expansion plan(GEP) approach con-sidering not only KEPCo's supply-side resources but also outside resources such as non-utility generation(NUG) demand-side management (DSM). Under the environmental situation in the current electric utility industry a new approach is needed to acquire multiple resources competitively. This study presents the development of a modified electric generation expansion analysis system(EGEAS) model with avoided cost based on the existing EGEAS model which is a dynamic program to develope an optimal generation expansion plan for the electric utility. We are trying to find optimal GEP in Korea's case using our modified model and observe the difference for the level of reliabilities such as the reserve margin(RM) loss of load probability(LOLP) and expected unserved energy percent(EUEP) between the existing EGEAS model and our model. In addition we are trying to calculate avoided cost for NUG resources which is a criterion to evaluate herem and test possibility of connection calculation of avoided cost with GEP implementation using our modified model. The results of our case study are as follows. First we were able to find that the generation expansion plan and reliability measures were largely influenced by capacity size and loading status of NUG resources, Second we were able to find that avoided cost which are criteria to evaluate NUG resources could be calculated by using our modified EGEAS model with avoided cost. We also note that avoided costs were calculated by our model in connection with generation expansion plans.

An Analysis of Best Practices for Efficient Utility Relocation and an Inquiry into the Applicability of SUE (효율적인 지하지장물 이설을 위한 모범사례분석 및 SUE 적용에 관한 연구)

  • Lee, Seung-Hyun;Baek, Seung-Ho;Tae, Yong-Ho;Ahn, Bang-Ryul;Park, Hyeon-Yong
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.971-976
    • /
    • 2007
  • In the U.S., utility damages or utility delay caused by conflicts during the underground utility relocation is one of the weighty problem in the construction industry. Also, in domestic case, delay and additional cost caused by underground utility(i.e, electricity, communication, gas, water supply and sewerage) relocation has been happened so that there is an increase of claims for responsibility between owners and contractors. However, there is insufficient survey for the recent circumstance of additional cost for delay and design changes caused by utility relocation and shortage of enough research for solving and analyzing of causes and their ripple effect. This research presents a result of the study about the best practices of FHWA(Federal Highway Administration), SHAs(State Highway Agencies) and the utility companies managing utility relocation. Also, it presents the basic concept of SUE(Subsurface Utility Engineering), the most reliable tool of FHWA presented, and investigates the developing status about SUE in Korea. At the end of this paper, this research proposes a practical and more applicable study about the efficient utility relocation focusing on local industry.

  • PDF

An Economic Evaluation of Thread Embedding Acupuncture for the Treatment of Lumbar Herniated Intervertebral Disc in a Randomized Controlled Clinical Trial

  • Kim, Ha-Na;Kim, Jun-Yeon;Park, Kyeong-Ju;Hwang, Ji-Min;Jang, Jun-Yeong;Jo, Min-Gi;Ko, Min-Jung;Chae, Sang-Yeup;Kim, Jung-Hyun;Goo, Bonhyuk;Park, Yeon-Cheol;Seo, Byung-Kwan;Baek, Yong-Hyeon;Nam, Sang-Soo
    • Journal of Acupuncture Research
    • /
    • v.38 no.4
    • /
    • pp.312-319
    • /
    • 2021
  • Background: Lumbar herniated intervertebral disc (LHIVD) is a frequently presented condition/disease in Korean medical institutions. In this study, the economics of thread embedding acupuncture (TEA) was evaluated in a randomized controlled trial comparing TEA with sham TEA (STEA). Methods: This economic evaluation was analyzed from a limited social perspective, and the per-protocol set was from a basic analysis perspective. The cost-effectiveness analysis was based on the change in visual analog scale score, and the cost-utility analysis was based on the quality-adjusted life years. The final results were expressed as the average cost-effectiveness ratio and incremental cost-effectiveness ratio, and furthermore sensitivity analysis was performed to confirm the robustness of the results observed. Results: The cost-effectiveness analysis showed that TEA was 9,908 won lower than STEA, while the decrease in 100 mm visual analog scale score was 8.5 mm greater in the TEA group compared with the STEA group (p > 0.05). The cost-utility analysis showed that TEA was 9,908 won lower than STEA, while the quality-adjusted life years of TEA was 0.0026 years higher than STEA (p > 0.05). These results were robust in the sensitivity analysis, but were not statistically significant. Conclusion: In treating LHIVD, TEA appeared to have cost-effectiveness and cost-utility compared with STEA. However, there were no significant differences between the groups in terms of cost, effectiveness, and utility indicators. Therefore, results must be interpreted prudently; this study was the 1st to conduct an economic evaluation of TEA for LHIVD.

The Effect of Control-Ownership Disparity on Cost Stickiness

  • Chae, Soo-Joon;Ryu, Hae-Young
    • Journal of Distribution Science
    • /
    • v.14 no.8
    • /
    • pp.51-57
    • /
    • 2016
  • Purpose - If control-ownership disparity is large, managers will not actively reduce costs; rather, they will maintain unutilized resources or possess surplus resources even when sales decrease with the purpose of increasing personal utility from status, power, compensation, and prestige. These managers' utility maximizing tendencies cause cost stickiness. We examine whether asymmetric behavior related to costs becomes stronger when there is a large disparity between ownership and control rights. Research design, data, and methodology - We construct a regression model to examine the relationship between control-ownership disparity and cost stickiness. STICKY, a dependent variable representing cost stickiness is a value found using the method of Weiss (2010), and Disparity is an interest variable that shows control-ownership disparity. Results - This study is based from the unique situations in Korea, in which high control-ownership disparity is common in firms. Large control-ownership disparity was found to increase cost stickiness of corporations. Conclusions - The results of this study imply that controlling shareholders may be regarded as a threat to the interests of minority shareholders and corporate values especially when controlling shareholders have significant influence over managers or the power to make managerial decisions as owners of a corporation.

A Study on Optimal Reliability Criterion Determination for Transmission System Expansion Planning

  • Tran Trungtinh;Choi Jae-Seok;Jeon Dong-Hoon;Chu Jin-Boo;Thomas Robert;Billinton Roy
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.62-69
    • /
    • 2005
  • The optimal design of transmission system expansion planning is an important part of the overall planning task of electric power system under competitive electricity market environments. One of main keys of the successful grid expansion planning comes from optimal reliability level/criteria decision, which should be given for constraint in the optimal expansion problem. However, it's very difficult to decide logically the optimal reliability criteria of a transmission system as well as generation system expansion planning in a society. This paper approaches a methodology for deciding the optimal reliability criteria for an optimal transmission system expansion planning. A deterministic reliability criteria, BRR (Bus Reserve Rate) is used in this study. The optimal reliability criteria, BRR/sup */, is decided at minimum cost point of total cost curve which is the sum of the utility cost associated with construction cost and the customer outage cost associated with supply interruptions for load considering bus reserve rate at load buses in long term forecasting. The characteristics and effectiveness of this methodology are illustrated by the case study using IEEE-RTS.