• Title/Summary/Keyword: Utility Work

Search Result 289, Processing Time 0.023 seconds

Energy Economics of Nuclear and Coal Fired Power Plant (원자력과 화력 발전소간의 에너지 비교 분석)

  • Lee, Gi-Won;Cho, Joo-Hyun;Kim, Seong-Rae;Park, Hae-Yun
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.403-417
    • /
    • 1995
  • The upturn of Korean nuclear power program can be considered to have started in early 70's while future plants for the construction of new nuclear power plane virtually came to a halt in United States. It is projected that power plant systems from combination of nuclear and coal fired types might shift to all coal fired type, considering the current trend of construction on the new Plants in the United States. However, with the depletion of natural resources, it is desirable to understand the utilization of two competitive utility technologies in terms of invested energy. Presented in this paper is a comparison between two systems, nuclear power plant and coal fired steam power plant in terms of energy investment. The method of comparison is Net Energy Analysis (NEA). In doing so, Input-Output Analysis (IOA) among industries and commodities is done. Using these information, net energy ratios are calculated and compared. NEA is conducted for power plants in U. S. because the availability of necessary data are limited in Korea. Although NEA does not offer conclusive solution, this method can work as a screening process in decision making. When considering energy systems, results from such analysis can be used as a general guideline.

  • PDF

Differential Changes in Commuter's Mode Choice after the Intergrated Public Transit System in Seoul Metropolitan City (서울시 대중교통체계 개편 이후 통근 교통수단 선택의 차별적 변화)

  • Lee, Hye-Seung;Lee, Hee-Yeon
    • Journal of the Korean Geographical Society
    • /
    • v.44 no.3
    • /
    • pp.323-338
    • /
    • 2009
  • This study analyzes the changes in commuter's mode choice between 2002 and 2006 according to the implement of the integrated public transit system in Seoul metropolitan city. Especially this study focuses on differential changes in a transit modal choice among socioeconomic status, trip purpose and spatial characteristics of origin and destination. The probability of public transit use against automobile is modeled as a function of socioeconomic variables, spatial characteristics of origin and destination and the utility of the commuter's mode. The results from conditional logit model analyses suggest that people with lower income show the larger changes in the ratio of public transit choice between 2002-06. Also both higher density, more accessible to public transit and more diverse land uses in residence zone and in work place generally increase the ratio of public transit choice between 2002-06. Car and subway have the most strong alternative relation in commuter's mode choice. The findings give an important implication that the integrated public transit system has differential impacts on commuter's mode choice in Seoul.

A study on analysis of DVR(Dynamic Voltage Restorer) in electric traction network by using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 전기철도급전계통에 DVR(Dynamic Voltage Restorer)해석에 관한 연구)

  • Choi, J.H.;Kim, J.C.;Park, S.M.;Kim, T.S.;Choo, D.W.;Chung, I.Y.;Park, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.283-286
    • /
    • 2003
  • The electric traction load is quite differ from general power system load which is single-phase, high-speed heavy load receiving power from 3-phase power system and also has variable load characteristics over time and space. Therefore, there are inevitably power quality problems such as steady state or transient voltage drop, voltage imbalance and harmonic distortion. In addition, it is expected that transient voltage sag could affect the safety of feeding system. Thus, in this paper transient analysis and voltage sag compensation of AT(Auto Transformer) feeding system are studied. The fault study of traction network is analysed by using PSCAD/SMTDC simulation tool. In addition, application of DVR in electric traction system is proposed to compensate the voltage sag of traction network which is occurred by the fault of utility source. The results of fault study will be a useful research works for operation and setting of electric traction relay. Also, it can be shown that application of the DVR in electric system is very useful to compensate the voltage sag from the result of related simulated work. The results of study will be a useful research works for management and planning of power quality in electric traction system.

  • PDF

Enantioselective Epoxide Synthesis on the Chiral Salen Catalyst having a Transitional Metal Salt (전이금속염 함유 키랄 살렌 촉매에 의한 광학선택적 에폭사이드의 합성)

  • Guo, Xiao-Feng;Kawthekar, Rahul B.;Kim, Geon-Joong
    • Korean Chemical Engineering Research
    • /
    • v.46 no.4
    • /
    • pp.769-776
    • /
    • 2008
  • The stereoselective synthesis of chiral terminal epoxide is of immense interest due to their utility as versatile starting materials as well as chiral intermediates. In this study, new chiral Co(salen) complexes bearing cobalt(II) chloride, iron(III) chloride and zinc(II) nitrate have been synthesized and characterized. The mass and EXAFS spectra provided the direct evidence of formation of complex. Their catalytic activity and selectivity have been demonstrated for the asymmetric ring opening of terminal epoxides such as styrene oxide and phenylglycidylether by hydrolytic kinetic resolution technology and for the synthesis of glycidyl buthylate. The easily prepared complexes exhibited very high enantioselectivity for the asymmetric ring opening of epoxides with $H_2O$ nucleophile, providing enantiomerically enriched terminal epoxides (>99% ee). The newly synthesized chiral salen showed remakablely enhanced reactivity with substantially low loadings. The system described in this work is very efficient for the sinthesis of chiral epoxide and 1,2-diol intermediates.

Excess Taurine Induced Placental Glutathione S-transferase Positive Foci Formation in Rat

  • Kweon, Sang-Hui;Kim, Yoon;Choi, Hay-Mie;Kwon, Woo-Jung;Chang, Kyung-Ja
    • BMB Reports
    • /
    • v.33 no.6
    • /
    • pp.469-475
    • /
    • 2000
  • The purpose of this study was to examine the chemopreventive potential of taurine at various levels on the diethylnitrosamine (DEN)·induced hepatocarcinogenesis. Male Sprague-Dawley rats were fed on diets containing 0, 1, 2, 3% taurine or 5% ${\beta}-alanine$ for taurine depletion. Then they were treated with DEN and 2/3 partial hepatectomy. The number of placental glutathione S-transferase positive ($GST-P^+$) foci, as a preneoplastic marker in the 1 % taurine group was lower than the control diet group. However the difference was insignificant. Although taurine diets reduced the thiobarbituric acid reactive substance (TBARS) level, the number of $GST-P^+$ foci was increased in 3% taurine diet group. The 1 % taurine diet increased the glutathione (GSH) level and GST activity, however they unfortunately did not suppress the foci formation. In the 3% taurine group, the GSH level and GSH peroxidase (GPx) activity were significantly decreased. Excess taurine supplementation of the pharmaceutical dose worked against hepatic chemoprevention, which might result from modulation of GPx activity and GSH utility. On the contrary, taurine might work as an antioxidant against TBARS production as the 1 % taurine diet increased GSH level. The potency of the cancer preventive effect of taurine still remains and further studies should investigate the effect of taurine with less than 1 % levels on the prevention of hepatic cancer.

  • PDF

Extractive Distillation Process for the Production of Highly Purified Ethanol from Aqueous Solution using Dimethyl Sulfoxide and Ethylene Glycol (Dimethyl Sulfoxide와 Ethylene Glycol을 이용하여 에탄올 수용액으로부터 고순도 에탄올을 생산하기 위한 추출증류공정)

  • Noh, Sang-Gyun
    • Clean Technology
    • /
    • v.22 no.4
    • /
    • pp.241-249
    • /
    • 2016
  • In this study, comparative work has been performed between two-columns and three-columns configurations for an extractive distillation process to produce highly purified ethanol with not less than 99.7 wt% using dimethyl sulfoxide (DMSO) and ethylene glycol (EG) as extracting agents. Optimal ethanol concentration at a concentrator top stream which minimized the total reboiler heat duties was determined for a three-columns configuration for two different solvents. For the thermodynamic model, NRTL liquid activity coefficient model was used and PRO/II with PROVISION 9.4 at Schneider electric company was utilized. DMSO was proved to be a better solvent than EG and three-columns configuration is better than two- columns configuration in the total utility consumptions since some of the liquid water contained in the feed stream was removed at a concentrator bottom liquid stream.

Applications of Mobile GIS Solution for Utility Management (시설물관리를 위한 Mobile GIS 솔루션 활용)

  • 한승희;이용욱;이형석
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.1
    • /
    • pp.69-75
    • /
    • 2002
  • The important issues of facility database management in GIS are to collect up-to-date information and to update information in accordance with new-establishment, repair and replacement of the facilities. Therefore, it is necessary to develop a system which has capability of monitoring facilities as well as managing database efficiently. The purpose of this study is to propose possibility of implementation of mobile GIS solution for the facility management. In order to achieve the goal, to process existing digital maps and to receive on-site information through the wireless communication service are required. In addition, the system is required to process spatial information obtained by GPS and digital photogrammetric technique with real-time updating database in server. The system increases efficiency both in work flow and monitoring for facility management by providing optimal routing information to the sites and real-time two-way communication using VoIP(Voice over Internet Protocol). The system is expected to perform real-time database management effectively. In consequence, the system could appropriately response on-site situations in various practical applications. The proposed technology could contribute to improve nation's leading-edge technology.

Observable Behavior for Implicit User Modeling -A Framework and User Studies-

  • Kim, Jin-Mook;Oard, Douglas W.
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.35 no.3
    • /
    • pp.173-189
    • /
    • 2001
  • This paper presents a framework for observable behavior that can be used as a basis for user modeling, and it reports the results of a pair of user studies that examine the joint utility of two specific behaviors. User models can be constructed by hand, or they can be teamed automatically based on feedback provided by the user about the relevance of documents that they have examined. By observing user behavior, it is possible to obtain implicit feedback without requiring explicit relevance judgments. Four broad categories of potentially observable behavior are identified : examine, retain, reference, and annotate, and examples of specific behaviors within a category are further subdivided based on the natural scope of information objects being manipulated . segment object, or class. Previous studies using Internet discussion groups (USENET news) have shown reading time to be a useful source of implicit feedback for predicting a user's preferences. The experiments reported in this paper extend that work to academic and professional journal articles and abstracts, and explore the relationship between printing behavior and reading time. Two user studies were conducted in which undergraduate students examined articles or abstracts from the telecommunications or pharmaceutical literature. The results showed that reading time can be used to predict the user's assessment of relevance, that the mean reading time for journal articles and technical abstracts is longer than has been reported for USENET news documents, and that printing events provide additional useful evidence about relevance beyond that which can be inferred from reading time. The paper concludes with a brief discussion of the implications of the reported results.

  • PDF

A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter (3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구)

  • Han, Hee-Min;Kim, Min-Young;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.72-81
    • /
    • 2009
  • This paper presents quasi-resonant type high power factor ac power supply for atmospheric pressure plasma cleaning system adopting three phase PFC boost converter and it's control method. The presented ac power supply consists of single phase H-bridge inverter, step-up transformer for generating high voltage and three phase PFC boost converter for high power factor on source utility. Unlikely to the traditional LC resonant converter, the propose one has an inductor inside only. A single resonant takes place through the inside inductor and the capacitor from the plasma load modeled into two series capacitor and one resistance. The quasi-resonant can be achieved by cutting the switching signal when the load current decrease to zero. To obtain power control ability, the propose converter controlled by two control schemes. One is the changing output pulse period scheme in the manner of PFM(Pulse Frequency Modulation) control. On the other, to provide more higher power to load, the DC rail voltage is directly controlled by the 3-phase PFC boost converter. The significant merits of the proposed converter are the uniform power providing capability for high quality plasma generation and low reactive power in AC and DC side. The proposed work is verified through digital simulation and experimental implementation.

Survey & Analysis for the Calculation on the Industrial Customer Interruption Costs (산업용 수용가의 정전비용 산출을 위한 조사 분석(I))

  • Nam, K.Y.;Choi, S.B.;Ryoo, H.S.;Jeong, S.H.;Lee, J.D.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.122-124
    • /
    • 2003
  • In recent, the various electric & electronic machines are newly developed everyday and the electricity supply system & environment on the process from generation to consumption of electricity also is being changed. In other words, both supplier and consumer of electricity are required to be responsible for their interruption costs. So, it is very important and meaningful work for evaluating the interruption costs in quantitative. Additionally, since the restructuring of electric industry is on going in world wide, after restructuring, most of all electric utilities and consumer have to consider the supply reliability and quality as a important element of the calculating the related costs and contract because it takes costs to keep the supply reliability and quality highly. Especially, the interruption or the supply reliability will have influence on the bilateral contract between supplier and customer as a key point to determine the once in competitive electric market. Therefore, it has very important moaning to calculate the interruption costs in the present that it is prepared to open the competitive electric market. In this paper, international standards, i.e. IEC, IEEE, are applied to the analysis on the interruption costs used in the questionnaires which are newly designed including short duration interruption by the authors instead of traditional interruption criteria. Firstly, using the questionnaires, the authors got related data from industries according to the standard industry classification which are being used in electric utility and other national statistics in Korea. However, analysis results are hard to say typical value because of the not so many samples. So, the authors are going to survey and focus on not all kinds of industry but a few kinds of them that their facilities are effected or stop by short duration interruptions, so there are large economical damages. Finally, the authors hope to find the reliable and meaningful model in interruption costs of industrial customer.

  • PDF