• Title/Summary/Keyword: Utility Weight

Search Result 162, Processing Time 0.031 seconds

Optimum design of steel space structures using social spider optimization algorithm with spider jump technique

  • Aydogdu, Ibrahim;Efe, Perihan;Yetkin, Metin;Akin, Alper
    • Structural Engineering and Mechanics
    • /
    • v.62 no.3
    • /
    • pp.259-272
    • /
    • 2017
  • In this study, recently developed swarm intelligence algorithm called Social Spider Optimization (SSO) approach and its enhanced version of SSO algorithm with spider jump techniques is used to develop a structural optimization technique for steel space structures. The improved version of SSO uses adaptive randomness probability in generating new solutions. The objective function of the design optimization problem is taken as the weight of a steel space structure. Constraints' functions are implemented from American Institute of Steel Construction-Load Resistance factor design (AISC-LRFD) and Ad Hoc Committee report and practice which cover strength, serviceability and geometric requirements. Three steel space structures are optimized using both standard SSO and SSO with spider jump (SSO_SJ) algorithms and the results are compared with those available in the literature in order to investigate the performance of the proposed algorithms.

Demand Response Real Time Pricing Model for Smart Grid Considering Consumer Behavior and Price Elasticity (소비자 행동과 가격탄성을 고려한 스마트 그리드 수요반응 실시간 가격 결정 모델)

  • Moon, Yongma
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.39 no.1
    • /
    • pp.49-67
    • /
    • 2014
  • This paper proposes a real time pricing model for smart grid considering consumers' behavior, real time price elasticity, and exogenous price. Based on the proposed model, we found the weight of utility over cost is the most sensitive factor compared to other factors. Also, if the electricity price is set to be changed too sensitively to energy consumption, it is warned that real time pricing sometimes can cause increment of peak-time demand and volatility. Finally, real time pricing could be less efficient when the difference between the maximum and the minimum consumption level is small.

Development of Safety Assessment Algorithm for Submerged Electrical Utilities (침수전기설비 안전성 평가 알고리즘 개발)

  • Jung, Jong-Wook;Jung, Jin-Soo;Lim, Yong-Bae;Bae, Seok-Myung;Kim, Joon-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.454-455
    • /
    • 2006
  • This paper describes the safety assessment algorithm applied for the underground electrical utilities submerged due to flooding. In implementing the algorithm, several factors pertaining to utility safety were introduced into the process flow, and safety weight was given to each factor. It is considered that this algorithm can ensure the safety of electrical utilities installed underground when they are submerged.

  • PDF

A Fundamental Study on the Development of Fire Resistance Filling of Friendly Environment Using Aerated Concrete (기포콘크리트를 이용한 친환경 내화충전제개발에 관한 기초적 연구)

  • Lee, jong-il;Lim, Nam-Gi
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.119-126
    • /
    • 2007
  • In this study, we processed two procedures of application test of filler for fire-resistance utility that are new application methods of aerated concrete and properties test of aerated concrete according to mixing ratio because we investigated the better use of aerated concrete as filler for fireproof safety and we proposed basic data about standardization of mixing of aerated concrete. We measured flow and volume change of aerated concrete. And if its volume doesn't change, we added measuring unit weight and compressive strength. To test application of aerated concrete as filler for fireproof safety, we filled up aerated concrete to fireproof safety according to suitable mixing ratio. Then we measured maximum temperature of inner part of fireproof safety in accordance with the standard test of fireproof. According to the results, aerated concrete as filler for fireproof safety could be possibly used. So when we make aerated concrete, we should consider using an adding agent as well as a foaming agent.

Finite Element Analysis of Gas-Gas Heater Sector Plate in Thermal Power Plant (화력발전용 가스재열기 Sector Plate의 유한요소 해석)

  • Hwang, Suk-Hwan;Lee, Hoo-Gwang;Choi, Jae-Seung
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.860-864
    • /
    • 2001
  • Today's industrialized plants are required to reduce SOx emitted from stacks at factories, utility power stations, etc. For this purpose, flue gas desulfurization (FGD) system is installed and gas-gas heater (GGH) is used to play a vital role to reheat the wet treated gas from FGD. The sector plates are located at cold and hot sides of gas gas heater. They serve as sealing to prevent mixing treated and untreated gases. Therefore, the deformation of the sector plate due to its dead weight and gas pressure should be considered as major factor for the sector plate design.

  • PDF

Synthesis of Newel Positive Type Photosensitive Polyimide

  • Ahn, Byung-Hyun;Lee, Dae-Woo;Lee, Jin-Kook
    • Macromolecular Research
    • /
    • v.9 no.5
    • /
    • pp.247-252
    • /
    • 2001
  • Tricyclic aliphatic dianhydride monomer, tricycle[4.2.2.0]dec-9-ene exo, endo-3,4: 7,8-tetra-carboxylicdianhydride (TCDDA), was synthesized by photochemical reaction and poly(amic acid)s from TCDDA and diamines such as 1,4-bis-(4-aminophenoxy)benzene (BAB), 2,2-bis(4-(4-aminophenoxy) phenyl) propane (BAPP), 2,2-bis(4-(4-aminophenoxy)phenyl)hexafluoropropane (BAPHF), bis(4-(4-ami-nophenoxy) phenyl)sulfone (BAPS), and 1,4-bis-(4-aminophenoxy)biphenyl (BABP) were prepared. The inherent viscosities of the poly(amic acid)s were between 0.39 and 0.50 dL/g. The poly(amic acid)s were converted to polyimide films by thermal imidization. The glass transition temperatures (T$\_$g/) of the polyimides were in the range of 201-263$\^{C}$. The thermogravimetric analysis (TGA) thermogram of these polyimides showed the temperatures of 5% weight losses between 375 and 393$\^{C}$ in nitrogen atmosphere. To show their utility for image generation, degradations of these polyimides in UV exposure were investigated by UV spectroscopy.

  • PDF

Multi-Criteria Decision Making Procedure under Incompletely Identified Preference Information

  • Ahn, Byeong-Seok;Kim, Jae-Kyeong;Kim, Soung-Hie
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.23 no.3
    • /
    • pp.63-73
    • /
    • 1998
  • The paper deals with interactive multiple criteria decision making procedure when decision maker (DM) specifies her or his preference in incomplete ways. Usually DM is willing or able to provide only incomplete information, because of time pressure and lack of knowledge or data. Under incomplete information on utility and attribute weight, the pairwise dominance checks result in strict or weak dominance values. Considering only strict dominance values sometimes fails to Prioritize alternatives because of fuzziness of preference information. Further there exists some information loss useful if used, otherwise. In this paper, we consider the outranking concept which implies the willingness of DM's taking some risk under the least favorable situation because she has enough reasons to admit the results. By comparing the magnitude of net preference degree of alternatives which is defined by difference between outrankings and outranked degree of each alternative, we can prioritize alternatives.

  • PDF

A Study of the Conceptual Design of Medium Size Utility Helicopter Rotor System (중형 헬리콥터 로터 시스템 개념설계 연구)

  • Kim, June-Mo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.3 s.22
    • /
    • pp.33-41
    • /
    • 2005
  • This paper describes the conceptual design of medium size helicopter rotor system. Based on assumed design requirements, trade-off study for rotor configuration has been conducted in terms of rotor tip speed, disk loading, blade area, solidity, etc for estimated primary mission gross weight. For the main rotor, four-blade and five-blade rotors are studied with the conventional tail rotor. The performance analysis for baseline configuration is conducted using a helicopter performance analysis program. The analysis shows design results satisfy the design requirements.

A study on the Improvement of Facility Layout in Locomotive Maintenance Workshop (철도차량 정비공장의 설비배치 개선에 관한 연구)

  • 이상설;안도만;강희정
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.49
    • /
    • pp.89-98
    • /
    • 1999
  • The objective of this study is to develop an improved algorithm for layout problems. Computerized facility layout program was also applied to solve the layout problem in locomotive maintenance workshop. The current facility layout is structured in the large space without considerations of many variable factors. For this reason, effectiveness of layout results in loss on effective space utility. This study is to develop an algorithm in the consideration of importance weight and desirable shape of specific department in the computerized layout planning and quantitative relationship rating between each department was used. Standard process duration of locomotive maintenance workshop was used to select the main activities of locomotive maintenance work. This study could generate more efficient facility layout design to reduce the number of movement frequency and travel distance in maintenance workshop.

  • PDF

Combustion and Emission Characteristics of Utility Boiler burning Anthracite-Bituminous Coal Blends (발전용 보일러에서의 유, 무연탄 혼소시 연소 및 환경특성)

  • Park, Ho-Young;Kim, Young-Joo;Park, Hyun-Joo;Kim, Sung-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.153-160
    • /
    • 2008
  • The combustion behaviors of the blends of Korean anthracite, bituminous coal and their blends were studied with a thermogravimetric analyzer. Concerning the burning profiles of the anthracite-bituminous coal blends in TGA, it has been observed the independent burning of two coals without any interaction between two coals. With the blends of 50% anthracite with 50% bituminous coal in weight basis, the combustion tests in a utility boiler have been carried out for the analysis of the combustion and operational characteristics by increasing the power output from 134 MW to 197 MW. The stable combustion has been observed in a boiler. With the increase of power output, the exhaust gas temperature was exceeded the design value of $430^{\circ}C$, so the combustion air was taken from atmosphere instead of the boiler penthouse.