• Title/Summary/Keyword: Utility Measurement

Search Result 232, Processing Time 0.023 seconds

A Study on the Development of Fashion Sensibility (Part II) (패션감성의 측정도구 개발에 관한 연구(제2보))

  • 이경희;김유진
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.5
    • /
    • pp.505-516
    • /
    • 2003
  • The purpose of this study was to develop the measurement of fashion sensibility and to verify the validity and utility. The survey has been done 91 photos selected in fashion magazines with 25 semantic differential hi-polar scale. The obtained data were analyzed by MDS, Discriminant analysis and Regression analysis. The major findings of this research were as follows. 1. According to the sensibility positioning, fashion image was classified by 4 group and agreed with constructing factors of fashion. 2. As result of the discrimination analysis, distinguishable fashion sensibility among design elements of clothing was related to refined, pleasant, feel like buying sensibility. 3. As result of the regression analysis, Preference was related to looking good, refined, and sweet, Buying needs related to likable, looking good and natural, Riches related to elegant, neat and refined, Pleasure related to looking good, elegant and bright. 4. The fashion design properties were different regarding Preference, Buying needs. Riches and Pleasure. Preference and Buying needs were related to H-line, similarity color combination, cotton and linen, Riches related to brilliance texture, ruffle and flounces, Pleasure related to fit and sexy design of clothing.

EVOLUTION OF NUCLEAR FUEL MANAGEMENT AND REACTOR OPERATIONAL AID TOOLS

  • TURINSKY PAUL J.;KELLER PAUL M.;ABDEL-KHALIK HANY S.
    • Nuclear Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.79-90
    • /
    • 2005
  • In this paper are reviewed the current status of nuclear fuel management and reactor operational aid tools. In addition, we indicate deficiencies in current capabilities and what future research is judged warranted. For the nuclear fuel management review the focus is on light water reactors and the utilization of stochastic optimization methods applied to the lattice, fuel bundle, core loading pattern, and for BWRs the control rod pattern/core flow design decision making problems. Significant progress in addressing separately each of these design problems on a single cycle basis is noted; however, the outstanding challenge of addressing the integrated design problem over multiple cycles under conditions of uncertainty remains to be addressed. For the reactor operational aid tools review the focus is on core simulators, used to both process core instrumentation signals and as an operator aid to predict future core behaviors under various operational strategies. After briefly reviewing the current status of capabilities, a more in depth review of adaptive core simulation capabilities, where core simulator input data are adjusted within their known uncertainties to improved agreement between prediction and measurement, is presented. This is done in support of the belief that further development of adaptive core simulation capabilities is required to further significantly advance the utility of core simulators in support of reactor operational aid tools.

Application of Dual-Energy Spectral Computed Tomography to Thoracic Oncology Imaging

  • Cherry Kim;Wooil Kim;Sung-Joon Park;Young Hen Lee;Sung Ho Hwang;Hwan Seok Yong;Yu-Whan Oh;Eun-Young Kang;Ki Yeol Lee
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.838-850
    • /
    • 2020
  • Computed tomography (CT) is an important imaging modality in evaluating thoracic malignancies. The clinical utility of dual-energy spectral computed tomography (DESCT) has recently been realized. DESCT allows for virtual monoenergetic or monochromatic imaging, virtual non-contrast or unenhanced imaging, iodine concentration measurement, and effective atomic number (Zeff map). The application of information gained using this technique in the field of thoracic oncology is important, and therefore many studies have been conducted to explore the use of DESCT in the evaluation and management of thoracic malignancies. Here we summarize and review recent DESCT studies on clinical applications related to thoracic oncology.

Utility of Pyloric Length Measurement for Detecting Severe Metabolic Alkalosis in Infants with Hypertrophic Pyloric Stenosis

  • Hyun Jin Kim
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.2
    • /
    • pp.88-94
    • /
    • 2024
  • Purpose: Infantile hypertrophic pyloric stenosis (IHPS) is a common gastrointestinal disease in neonates and hypochloremia metabolic alkalosis is a typical laboratory finding in affected patients. This study aimed to analyze the clinical characteristics of infants with IHPS and evaluate the association of clinical and laboratory parameters with ultrasonographic findings. Methods: Infants diagnosed with IHPS between January 2017 and July 2022 were retrospectively evaluated. Results: A total of 67 patients were included in the study. The mean age at diagnosis was 40.5±19.59 days, and the mean symptom duration was 11.97±9.91 days. The mean pyloric muscle thickness and pyloric canal length were 4.87±1.05 mm and 19.6±3.46 mm, respectively. Hyponatremia and metabolic alkalosis were observed in five (7.5%) and 36 (53.7%) patients, respectively. Serum sodium (p=0.011), potassium (p=0.023), and chloride levels (p=0.015) were significantly lower in patients with high bicarbonate levels (≥30 mmol/L). Furthermore, pyloric canal length was significantly higher in patients with high bicarbonate levels (p=0.015). To assess metabolic alkalosis in IHPS patients, the area under the receiver operating characteristic curve of pyloric canal length was 0.910 and the optimal cutoff value of the pyloric canal length was 23.5 mm. Conclusion: We found a close association between laboratory and ultrasonographic findings of IHPS. Clinicians should give special consideration to patients with pyloric lengths exceeding 23.5 mm and appropriate fluid rehydration should be given to these patients.

A Study on Economic Methodology for Deriving Money Coefficients (금전계수 도출을 위한 경제학적 방법론 연구)

  • Min-Hee Back
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.111-118
    • /
    • 2023
  • The International Commission on Radiological Protection (ICRP) 103 recommends a cost-benefit analysis method as an auxiliary tool for scientific and rational decision-making for the principle of optimization of radiological protection. In order to conduct a cost-benefit analysis, the safety improvement of nuclear power by regulation must be measured and converted into monetary terms. The improvement of nuclear safety can be measured by reducing the radiation exposure dose of the people, and it is necessary to determine the coefficient to convert the radiation exposure dose into money. The monetary coefficient is calculated as the product of the statistical life value (VSL) and the nominal risk coefficient. In order to derive the monetary coefficient, the willingness to pay (WTP) can be estimated using the contingent valuation method (CVM), which quantifies the value of non-market goods by converting them into monetary units. WTP can be estimated based on the random utility model, which is the basic model for bivariate selection type conditional value measurement data. Statistical life value can be calculated using the estimated WTP and reduction in early mortality, and a monetary coefficient can be derived.

On-site Water Nitrate Monitoring System based on Automatic Sampling and Direct Measurement with Ion-Selective Electrodes

  • Kim, Dong-Wook;Jung, Dae-Hyun;Cho, Woo-Jae;Sim, Kwang-Cheol;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.350-357
    • /
    • 2017
  • Purpose: In-situ monitoring of water quality is fundamental to most environmental applications. The high cost and long delays of conventional laboratory methods used to determine water quality, including on-site sampling and chemical analysis, have limited their use in efficiently managing water sources while preventing environmental pollution. The objective of this study was to develop an on-site water monitoring system consisting mainly of an Arduino board and a sensor array of multiple ion selective electrodes (ISEs) to measure the concentration of $NO_3$ ions. Methods: The developed system includes a combination of three ISEs, double-junction reference electrode, solution container, sampling system consisting of three pumps and solenoid valves, signal processing circuit, and an Arduino board for data acquisition and system control. Prior to each sample measurement, a two-point normalization method was applied for a sensitivity adjustment followed by an offset adjustment to minimize the potential drift that could occur during continuous measurement and standardize the response of multiple electrodes. To investigate its utility in on-site nitrate monitoring, the prototype was tested in a facility where drinking water was collected from a water supply source. Results: Differences in the electric potentials of the $NO_3$ ISEs between 10 and $100mg{\cdot}L^{-1}$ $NO_3$ concentration levels were nearly constant with negative sensitivities of 58 to 62 mV during the period of sample measurement, which is representative of a stable electrode response. The $NO_3$ concentrations determined by the ISEs were almost comparable to those obtained with standard instruments within 15% relative errors. Conclusions: The use of the developed on-site nitrate monitoring system based on automatic sampling and two-point normalization was feasible for detecting abrupt changes in nitrate concentration at various water supply sites, showing a maximum difference of $4.2mg{\cdot}L^{-1}$ from an actual concentration of $14mg{\cdot}L^{-1}$.

Development of deep learning algorithm for classification of disc cutter wear condition based on real-time measurement data (실시간 측정데이터 기반의 디스크커터 마모상태 판별 딥러닝 알고리즘 개발)

  • Ji Yun Lee;Byung Chul Yeo;Ho Young Jeong;Jung Joo Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.3
    • /
    • pp.281-301
    • /
    • 2024
  • The power cable tunnels which are part of the underground transmission line project, are constructed using the shield TBM method. The disc cutter among the shield TBM components plays an important role in breaking rock mass. Efficient tunnel construction is possible only when appropriate replacement occurs as the wear limit is reached or damage such as uneven wear occurs. A study was conducted to determine the wear conditions of disc cutter using a deep learning algorithm based on real-time measurement data of wear and rotation speed. Based on the results of full-scaled tunnelling tests, it was confirmed that measurement data was obtained differently depending on the wear conditions of disc cutter. Using real-time measurement data, an algorithm was developed to determine disc cutter wear characteristics based on a convolutional neural network model. Distributional patterns of data can be learned through CNN filters, and the performance of the model that can classify uniform wear and uneven wear through these pattern features.

A Study of the Basic Design for Smart Clothing based on Measurement of the Respiration (호흡 측정 기능의 스마트 의류를 위한 기초 디자인 연구)

  • Cho, Ha Kyung;Min, Se Dong
    • Science of Emotion and Sensibility
    • /
    • v.15 no.4
    • /
    • pp.415-424
    • /
    • 2012
  • According to introduction of Well-Being lifestyle and ageing society, vital sign monitoring system which can be continued measurement of vital sign has been increased their important in field of the healthcare. Under this trend, Respiration monitoring system has been studied and developed in a various way to apply continued monitoring and non-conscious monitoring system. But, Study of the respiration monitoring system based on consumer needs and usability test is insufficient. In this study, Textile capacitive pressure sensor(TCPS) of belt type was developed and tested it's utility and subjective sensibility. TCPS measures respiration signals and can be derived in real time monitoring. As a result, monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rate (correlation (r=0.9553, p<0.0001). In the result of usability and wearability test, all of categorizes(perceived change, wearability, movement, facility of management, usefulness) were received favorable evaluation on usability test( mean value : 3.8), and suitable location of TCPS in the clothing is deriven on the abdomen part. According to synthetical results, Basic smart clothing design based on respiration monitoring system is proposed.

  • PDF

Measurement for the Tuning Circle of the Stern Trawler HAELIM-3 by the Differential GPS (DGPS에 의한 선미트롤선 해림 3호의 선회권측정)

  • Choi, Jae-Eun;Kim, Jin-Kun;Kim, Ki-Yun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.1
    • /
    • pp.84-92
    • /
    • 1995
  • The methods by turning circle test and maneuvering indices have been used to study and evaluate the maneuverability of a ship. However recently many studies utilizing the GPS are made on the measurement of the turning circle and in the fishery and hydrographic survey. In this paper, the author carried out the turning circle test using the differential GPS and dumb card together, and compared the data measured by them and analyzed the accuracies of them to obtain the utility basic ones on the measurement of the turning circle by the DGPS. The main results area s follows : 1) To check the accuracies of the GPS, the circling experiments of 50m radius by the DGPS were made on the ground. The accuracies of turning circle measured by the DGPS were found to be very high as the errors of 1.5m. 2) the turning circle by the DGPS could be measured very accurately, by the seed, rudder angle, starboard and port respectively. 3) The turning circle measured by the dumb card was found to be measured accurately as much as the DGPS, when using large rudder angle, the turning circle was large, the turning circle by the dumb car could not be measured accurately on account of large error of bearing of compass. 4) The tactical diameters by the DGPS in case of the rudder angle 35。~5。, were found to be 2.6。15.0 times the Lpp of S.T HAELIM-3 at her slow speed 2.8~16.6 times her Lpp at her half speed, 3.1~17.4 times her Lpp at her full speed. The tactical diameter by the dumb card was found to be 2.4~9.5 times, 2.6~9.6 times, 3.2~12.2 times her Lpp respectively, in the above case and speed.

  • PDF

Development of 3D Radiation Position Identification System of Multiple Radiation Sources using Plastic Scintillator and NaI(TI) Detector (플라스틱 Scintillator와 NaI(TI) 검출기를 이용한 다수의 방사선원 위치를 3차원으로 판별하는 측정시스템 개발)

  • Kwak, Dong-Hoon;Ko, Tae-Young;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.638-644
    • /
    • 2018
  • In this paper, we develop a measurement system that uses 3D Scintillator and NaI(TI) Detector to 3-dimensionally identify the location of multiple radiation sources in moving vehicle loads. The radiation measurement system consists of radiation measurement (plastic scintillator), 2-channel Pulse Counter Board, nuclide analysis (NaI(TI) detector) and 1 channel MCA Board. The source locator algorithm calculates the coordinate value of the ratio of the CPS value($1/r^2$) of the source according to the angle(${\theta}$) in inverse proportion to the square of the distance(X, Y) through the SVM classification. The coordinate values are input every predetermined period of the spectrum, and after analyzing the spectrum per unit cycle, the position of the nuclide at the time is calculated by determining whether or not the nuclide is present in the remaining part except for the background area. As a result of the position discrimination test, the error within the international standard of ${\pm}1m$ was shown. Thus, the utility of the proposed system has been demonstrated.