• 제목/요약/키워드: Utility Grid

검색결과 244건 처리시간 0.028초

계통 연계형 태양광 발전 시스템의 위상 동기화를 위한 디지털 PLL 제어 (Digital PLL Control for Phase-Synchronization of Grid-Connected PV System)

  • 김용균;최종우;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권9호
    • /
    • pp.562-568
    • /
    • 2004
  • The frequency and phase angle of the utility voltage are important in many industrial systems. In the three-phase system, they can be easily known by using the utility voltage vector. However, in the case of single phase system, there are some difficulties in detecting the information of utility voltage. In conventional system, the zero-crossing detection method is widely used, but could not obtain the information of utility voltage instantaneously. In this paper, the new digital PLL control using virtual two phase detector is proposed with a detailed analysis of single-phase digital PLL control for utility connected systems. The experimental results under various utility conditions are presented and demonstrate an excellent phase tracking capability in the single-phase grid-connected operation.

리클로져의 동작특성을 고려한 계통연계형 태양광발전시스템의 보호 알고리즘 (A Protection Algorithm of Grid-Interactive Photovoltaic System Considering Operation Characteristics of Recloser)

  • 김슬기;김응상
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.280-286
    • /
    • 2006
  • The paper proposes a new protection algorithm for reliable operation of grid-interfaced PV system, which can flexibly interact with conventional protective schemes of power utility grid not only to prevent damages to utility or public persons and utility apparatus caused by malfunction or failure in distribution network protection system, but also to protect a PV system itself from faults or abnormal conditions of the network. The proposed algorithm is based on reclosing characteristics of the distribution system. As a network fault occurs, the new scheme determines whether it is momentary or permanent and responds in a pre-programmed way to the fault. For permanent outage, the proposed algorithm shuts down inverter's operations but monitoring system voltage and frequency at the point of common coupling with grid. When it comes to the momentary outage, Inverter starts stand-by operation mode so that it can be automatically connected to the grid without start-up procedures as soon as the system voltage and frequency returns into the normal operation range. In order to investigate' and evaluate the PV system operation, simulation study based on PSCAD/EMTDC has been carried out to verify the performance of the proposed protection scheme.

AMI 공격 시나리오에 기반한 스마트그리드 보안피해비용 산정 사례 (A Case Study of the Impact of a Cybersecurity Breach on a Smart Grid Based on an AMI Attack Scenario)

  • 전효정;김태성
    • 정보보호학회논문지
    • /
    • 제26권3호
    • /
    • pp.809-820
    • /
    • 2016
  • 스마트그리드는 사물인터넷의 핵심 응용서비스이고, 그 중 가장 핵심적인 구성요소인 AMI((Advanced Metering Infrastructure)는 전기사업자와 소비자의 접점에 위치하고 있으며, 스마트 미터는 소비자의 전기사용을 기록하고 사업자에게 전달하는 역할을 한다. 본 논문에서는 스마트그리드에서 소비자와 직접 맞닿아 있는 스마트 미터를 중심으로 AMI에 대한 NESCOR에서 제시하고 있는 사이버공격 및 피해 시나리오를 기반으로 피해비용을 산정한다. 본 연구의 결과는 정책입안자나 전기사업자가 스마트그리드 관련 투자의사결정을 하는데 참고가 될 수 있을 것이다.

계통연계형 인버터의 LCL필터 최적 설계기법 (Optimized LCL filter Design Method of Utility Interactive Inverter)

  • 정상혁;최세완
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.

전력회사와 발전사업자 측면에서 도서지역용 마이크로그리드의 경제성평가 알고리즘 (Economic Evaluation Algorithm of Island Micro-grid for Utility and Independent Power Producer)

  • 남양현;이후동;김유림;마리토;김미영;노대석
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1032-1038
    • /
    • 2017
  • Recently, regulation on carbon emissions has been strengthened according to the new climate change convention (COP21) held in Paris, and then Korea has decided to reduce CO2 emissions by 37% until 2030. As one of countermeasures, the government has energetically performed demonstration projects of island micro-grid including solar power, wind power and energy storage system. However, in order to smoothly introduce island micro-grid, it is a critical issue to carry out the economic evaluation for power utility aspect and independent power producer aspect. Therefore, this paper proposes economic evaluation algorithms of island micro-grid which are based on the present worth method, considering cost and benefit factors in the aspect of both sides. Firstly, in case of power utility this paper proposes algorithm to estimate a period of return on investment according to the introduction capacity of distributed generators replacing diesel generator. And also, in case of independent power producer, this paper proposes evaluation algorithm to estimate weighting factor of SMP and benefit rate based on break-even point related with cost and benefit. From a case study result on real island micro-grid model, it is confirmed that proposed algorithms are useful and practical for the economic evaluation of island micro-grid.

PHEV 시장 형성 시 전력망에 미치는 영향 및 최적 충전 제어 전략에 관한 연구 (Study on the Power-Grid Impact and Optimal Charging Control Strategy with PHEV Market Penetration)

  • 노철우;김민수
    • 대한기계학회논문집B
    • /
    • 제33권4호
    • /
    • pp.278-287
    • /
    • 2009
  • Plug-in hybrid electric vehicle (PHEV) with capability of being recharged from the power-grid will reduce oil consumption. Also, the PHEV will affect the utility operations by adding additional electricity demand for charging. In this research, the power-grid impact by demand of PHEV charging is presented and the optimal charging control strategy for utility operators is proposed with simulated data. The penetration of PHEV is assumed to be 50% in the circumstances of Korean passenger car market and Korean power-grid market limitedly. To obtain smooth load shape and utilize the surplus electricity in power-grid at midnight and dawn, the peak of charging demand should be controlled to be located before 4:00 a.m., and the time slot which can supply the electricity power to PHEV should be allowed between 1:00 a.m.$\sim$7:00 a.m.

그리드 어카운팅을 고려한 자원 접근 제어 메커니즘 (A Resource Access Control Mechanism Considering Grid Accounting)

  • 황호전;안동언;정성종
    • 정보처리학회논문지A
    • /
    • 제13A권4호
    • /
    • pp.363-370
    • /
    • 2006
  • 현재 그리드 환경에서 자원 접근 제어에 관련된 다양한 방법들이 연구되고 있다. 대부분 그리드 사용자의 자원 접근 권한은 사용자의 특성 및 역할에 따라 부여하도록 설계되었다. 그러나 그리드에 안정적인 자원을 지속적으로 제공하기 위해서는 유틸리티 컴퓨팅에 의한 자원 접근 제어가 이루어져야 한다. 따라서 본 논문에서는 자원 접근 제어에 그리드 어카운팅 개념을 접목시킨 메커니즘을 제안한다. 이 메커니즘은 자원 사용에 대한 어카운팅 정보를 기초로 처리 비용을 산출하고, 사용자의 가용 자금에 따라 자원 접근 여부를 결정하게 된다. 만약 사용자의 가용 자금이 자원 사용에 대한 처리 비용보다 부족할 경우, 사이트의 자원 접근 제어 정책에 따라 그리드 작업을 제어하게 된다. 최종적으로 그리드 작업이 완료되면, 자원 소비자가 자원 제공자측의 유휴 자원을 사용함으로써 발생되는 처리 비용을 지불한다. 그럼으로 본 논문은 그리드 어카운팅에 의한 사용자의 자원 접근을 제어할 수 있는 메카니즘을 제공함으로써, 경제 원리에 준하는 유틸리티 컴퓨팅 환경을 실현할 수 있는 연구로 평가된다.

Utility scale solar power development in Nepal

  • Adhikari, Rashmi
    • 한국태양광발전학회지
    • /
    • 제6권1호
    • /
    • pp.86-91
    • /
    • 2020
  • Nepal is among the richest in terms of water resource availability and it is one of the most important natural resources of the country. Currently, 72% of the population is electrified through the national grid system. The power generation mix into the grid is hydro dominated with minor shares generated from solar and thermal (accounts for less than 1%). To achieve sustainable development in the power sector it is essential to diversify power generation mix into the grid. Knowing the facts, the government has a plan to achieve a 5-10% share of power generation from solar and mix it into the grid system. Solar is the second most abundant, prominent and free source of renewable in the context of Nepal. This study mainly focuses on the grid-connected solar system, its importance, present status, government efforts, and its need. It is based on the review of literature, news published in national newspaper online news and international organization's report.

계통연계형 풍력, 태양광 및 축전지 하이브리드 시스템의 출력제어 및 동특성 해석 (Power Control and Dynamic Performance Analysis of a Grid-Interactive Wind/PV/BESS Hybrid System)

  • 김슬기;전진홍;조창희;안종보
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.317-324
    • /
    • 2007
  • Most conventional hybrid systems using renewable energy sources have been applied for stand-alone operation, but Utility-interface may be an useful and viable option for hybrid systems. Grid-connected operation may have benefits such as reduced losses in power system distribution, utility support in demand side management, and peak load shaving. This paper addresses power control and dynamic performance of a grid-connected PV/wind/BESS hybrid system. At all times the PV way and the wind turbine are individually controlled to generate the maximum energy from given weather conditions. The battery energy storage system (BESS) charges or discharges the battery depending on energy gap between grid invertger generation and production from the PV and wind system. The BESS should be also controlled without too frequently repeated shifts in operation mode, charging or discharging. The grid inverter regulates the generated power injection into the grid. Different control schemes of the grid inverter are presented for different operation modes, which include normal operation, power dispatching, and power smoothing. Simulation results demonstrate that the effectiveness of the proposed power control schemes for the grid-interactive hybrid system.

A Fast and Robust Grid Synchronization Algorithm of a Three-phase Converters under Unbalanced and Distorted Utility Voltages

  • Kim, Kwang-Seob;Hyun, Dong-Seok;Kim, Rae-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1101-1107
    • /
    • 2017
  • In this paper, a robust and fast grid synchronization method of a three-phase power converter is proposed. The amplitude and phase information of grid voltages are essential for power converters to be properly connected into the utility. The phase-lock-loop in synchronous reference frame has been widely adopted for the three-phase converter system since it shows a satisfactory performance under balanced grid voltages. However, power converters often operate under abnormal grid conditions, i.e. unbalanced by grid faults and frequency variations, and thus a proper active and reactive power control cannot be guaranteed. The proposed method adopts a second order generalized integrator in synchronous reference frame to detect positive sequence components under unbalanced grid voltages. The proposed method has a fast and robust performance due to its higher gain and frequency adaptive capability. Simulation and experimental results show the verification of the proposed synchronization algorithm and the effectiveness to detect positive sequence voltage.