• Title/Summary/Keyword: Useful energy

Search Result 2,416, Processing Time 0.03 seconds

An Evaluation of the Weights and Investigation of the Impact Factors for Supplying LNG (천연가스 공급타당성 검토를 위한 영향요인 발굴 및 중요도 평가)

  • Hong, Sung-Jun;Choi, Bong-Ha;Lee, Deok-Ki;Lee, Jeong-Tae;Park, Soo-Uk
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.1
    • /
    • pp.79-85
    • /
    • 2009
  • In this paper, we investigated impact factors by brainstorming and survey research and calculated the weights of them using the Analytic Hierarchy Process(AHP) method in order to evaluate alternatives for supplying Liquefied Natural Gas(LNG). AHP is a useful method for evaluating multi-criteria decision making problems. We selected 3 criteria and 9 sub-criteria. According to the result in this study, the most important sub-criterion is the Government's Policy, and the second is the Province's Policy. The other side, the lowest important sub-criterion is the Investment Cost. This study may provide basic data to select the optimal alternative for supplying LNG.

Theoretical Study on Hydrophobicity of Amino Acids by the Solvation Free Energy Density Model

  • Kim, Jun-Hyoung;Nam, Ky-Youb;Cho, Kwang-Hwi;Choi, Seung-Hoon;Noh, Jae-Sung;No, Kyoung-Tai
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1742-1750
    • /
    • 2003
  • In order to characterize the hydrophobic parameters of N-acetyl amino acid amides in 1-octanol/water, a theoretical calculation was carried out using a solvation free energy density model. The hydrophobicity parameters of the molecules are obtained with the consideration of the solvation free energy over the solvent volume surrounding the solute, using a grid model. Our method can account for the solvent accessible surface area of the molecules according to conformational variations. Through a comparison of the hydrophobicity of our calculation and that of other experimental/theoretical works, the solvation free energy density model is proven to be a useful tool for the evaluation of the hydrophobicity of amino acids and peptides. In order to evaluate the solvation free energy density model as a method of calculating the activity of drugs using the hydrophobicity of its building blocks, the contracture of Bradykinin potentiating pentapeptide was also predicted from the hydrophobicity of each residue. The solvation free energy density model can be used to employ descriptors for the prediction of peptide activities in drug discovery, as well as to calculate the hydrophobicity of amino acids.

Design Factor Calculation and Analysis of Grid-Connected Photovoltaic System (계통연계형 태양광발전시스템의 설계계수 산출분석)

  • So, Jung-Hun;Hwang, Hye-Mi;Jung, Young-Seok;Ko, Suk-Whan;Ju, Young-Chul;Lim, Hyun-Mook
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.89-94
    • /
    • 2013
  • This paper presents a simple but valid design factor calculation method of grid-connected photovoltaic system using normalized yield model. The proposed calculation method can be represented as a quantitative value about five design factors from irradiance to system output power. The validity of this method is identified by analyzing design factor with three years monitored data. These results will indicate that it is useful to determine the optimal design and selection of grid-connected photovoltaic system to meet different user purposes and enhance long-term reliability and stability of grid-connected photovoltaic system.

Output Characteristics of Parallel or Serially Connected Helical Magneto-Cumulative Generators (병렬 또는 직렬로 결합한 나선형 자장압축발전기의 출력특성 분석)

  • Kuk Jeong-Hyeon;Lee Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.647-657
    • /
    • 2004
  • Helical magneto-cumulative generator(HMCG)s are very useful devices in suppling pulsed high current to inductance loads. To apply fast high voltage pulses to high impedance loads, high current outputs of HMCGs are required to be conditioned to higher voltages by using various pulse components such as opening/closing switches and pulse transformer. In this paper, stepping with the trends of requirements for ever-increasing energy in pulsed power applications coupling methods is investigated to obtain higher output energy by connecting several HMCGs in series or parallel way. The coil dimension of HMCGs used in series or parallel connections was 50 mm in diameter and 150 mm in length. The coil was fabricated by using enamel-coated copper wire of 1 mm in diameter. The highest energy amplification ratio and peak voltage of load were achieved from the serially connected four-barrel HMCG system. They were 68 and 34 kV, respectively, when the initial energy of 0.36 kJ was supplied into that system with the load of 0.4 μH. Within the tested range of inductance ratio, energy amplification ratio was found to be highly dependent on the inductance ratio of serial- and parallel-connected HMCG systems to load, which to be optimal around 500 was turned out. The experimental results showed that the output energy and voltage of load are controlled by connecting HMCGs in series or parallel.

Analysis the Energy Consumption of a Wireless Network Interface in broadcast and point-to-point Environment (브로드캐스트와 Point-to-Point환경에서 무선 네트워크 인터페이스의 에너지 소비 측정 분석)

  • Choi Ji-Hoon;Kim Kwang-Deok;Kim Dong-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.111-114
    • /
    • 2006
  • This paper describes measurement of energy consumption when various size of data packets, on the both broadcast and point-to-point of Wireless network interface, are transmitted, received and discarded in the environment of Ad-hoc network. This experiment measures energy consumption using IEEE 802.11 wireless network interface with each condition. Since the measurements induces linear equation, it can provide useful information for protocol designer and developer. And this paper analyzes the information of behavior of energy consumption for the energy-aware design and the evaluation of network protocol on the practical wireless environment.

  • PDF

Hybrid between Inorganic Material and Biological Photosystem1 for Light Energy Application

  • Kim, Yeong-Hye;Nam, Gi-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.272-272
    • /
    • 2013
  • The attractive features of photosynthetic reaction center proteins for energy application make them useful in solar energy conversion to hydrogen fuel or electrical energy. Almost unity charge separation quantum yield and its rapid speed of ~1ns, absorbance region in visible light (480~740 nm) and high proportion of photosynthetically active solar energy of 48.5% allowed photosystem1 to exploited as a bio-material for photo-energy devices. Directionality of photosystem1 in electron transfer can solve main problem in two-step water splitting process where back reaction deteriorates the overall efficiency. In the study, photosystem1 was extracted from spinach and the photo-induced excited electron in the reaction center was utilized in various field of light energy application. First, hydrogen evolving system realized by photodeposition of platinum at the end of the electron transfer chain, with combining specific semiconductor to oxidize water in the first step of Z-scheme. The evaluation by gas-chromatography demonstrated hydrogen evolution through the system. For the further application of photoelectrical material on electrode, photosystem1 have been controlled by copper ion, which is expected to assemble photosystem in specific orientation followed by maximized photoelectrical ability of film. The research proposed concrete methods for combining natural protein and artificial materials in one system and suggested possibility of designing interface between biological and inorganic materials.

  • PDF

Study on Thermal Dewatering of Sludge Using the Parabolic Through Collector(PTC) Solar Collector (PTC태양열 집열기를 이용한 슬러지 열탈수 연구)

  • Lee, Jung-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • A fiat-plate or vacuum tube solar collector have been mainly used for hot water supply of house because of some being difficult to get uniform energy density, so little applied into industrial field. This study is to apply the PTC(parabolic trough collector) solar collector into industrial field such as sludge dewatering system for energy reduction. The real scale system which composed of PTC Solar Collector and Thermal Dewatering (TDW) is established. PTC solar collector is designed to produce a hot water with $80^{\circ}C$ of temperature. And size of TDW is $630{\times}630mm$. Hot water produced from PTC solar collector is supplied into heating plate of TDW, and sludge like waterworks or wastewater is dewatered. PTC solar collector with $10m^2$ of area produce energy of average 5,618 kcal. As according to results from real scale performance, solar collector takes charge 94 % of the amount that TDW consume energy which is so large part if compare with boiler. It means that PTC solar collector is useful to apply industrial field under the condition of sufficient solar radiation. And it is analyzed that TDW by PTC solar collector has an economical validity.

Characterising the dynamic seals used in absorber rod drive mechanisms in Indian FBR

  • Kaushal, Nihal;Patri, Sudheer;Kumar, R. Suresh;Meikandamurthy, C.;Sreedhar, B.K.;Murugan, S.;Raghupathy, S.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3438-3448
    • /
    • 2021
  • Dynamic seals are one of the critical components of Absorber Rod Drive Mechanism of Fast Breeder Reactors, requiring separate experimental development. Their significance can't be overemphasized considering that the availability and re-usability of Control Rod Drive Mechanisms of Fast Breeder Test Reactor is governed by the failure rate of dynamic seals (bellows). For prototype and subsequent Fast Breeder Reactors in India, choice of the dynamic seal is changed to an in-house designed & developed labyrinth type V-ring seal. The present work is related to the numerical investigations carried out to gain insights into the sealing mechanism and the thermal behaviour of these seals. The results indicate that the seal geometry is very important for obtaining optimum performance. By changing the geometry of the present seal, performance enhancement by more than 50% in important indices is obtained. Further, the results point out that caution shall be exercised when the seal material & its operating temperature are changed. Also, the numerical model developed in this study will be useful for developing more robust dynamic seals in future.

Prediction of a Leakage in a Liquid Hydrogen Pump Using a Finite Element Method (유한요소 해석을 이용한 액화수소 펌프 누설량 예측)

  • HYUNSE KIM;YOUNG-BOG HAM
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.3
    • /
    • pp.292-296
    • /
    • 2023
  • Until recently, ships, automobiles, and drones using hydrogen energy are being actively researched. In addition, stations and facilities for hydrogen supply are being developed widely. Among them, a hydrogen pump is necessary for compressing it and transfer to other stations. The liquid hydrogen pump is operated at very high pressure up to 90 MPa. In our research, a reciprocating plunger pump is studied. Especially, a leakage in a liquid hydrogen pump is predicted using a finite element method. As a result, it was found that leak mass flow rates changed from 0.09 to 2.20 kg/h, when the gaps were given from 2 to 6 ㎛. Thus pump efficiencies were calculated from 99.9 to 97.9%, when the gaps changed from 2 to 6 ㎛. These results are useful for the design of the liquid hydrogen pump.

A Study on the Integrated Fusion Technology Between a Carbon Dioxide Emission and a District Cooling Energy Using a Cold Energy ($CO_2$ 배출문제와 냉열이용 지역집단 냉방에너지에 관한 통합적 융합기술 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.34-40
    • /
    • 2006
  • This paper provides a fusion technology between a district cooling energy system and an environment conservation policy based on the energy savings and reusable cold energy resources. The district heating and cooling systems are very effective ways for an energy saving, a cost reduction and a safety control. It is necessary to equalize the energy savings and an environmental preservation policy for an improved human lift. A gasification process of a liquefied natural gas, cooling water from deep seawater and an ice water thermal storage system may produce a cold energy. A district cooling system is used to cool an apartment, office buildings and factory facilities with a cooling energy supply pipeline. LNG cooling energy will switch a conventional air-conditioning system, which is operated by on electrical energy and a Freon refrigerant. Coincident with significant clean energy and operating cost savings, LNG cold energy system owen radical reductions in an air-borne pollutant, $CO_2$ and the release of environmentally harmful refrigerants compared with that of the conventional air-conditioning system. This study provides useful information on the fusion technology of a LNG cold energy usage and energy savings, and environmental conservation.

  • PDF