• 제목/요약/키워드: Use of Facility

검색결과 1,738건 처리시간 0.029초

근린 주거환경이 노인의 사회적 네트워크 형성에 미치는 영향 - 중국 동북 지역을 중심으로 - (The Impacts of the Neighborhood Environment on the Social Network Formation of Elderly - Focusing on the Elderly in North-east Region of China -)

  • 무효우;이경훈
    • 대한건축학회논문집:계획계
    • /
    • 제35권8호
    • /
    • pp.65-72
    • /
    • 2019
  • The purpose of this study was to explore the influence of the topography and the neighborhood facility on the aged people's social network formation. The paper samples the aged people living in Changchun city located in a flat ground and Tonghua city located in a mountain region. Four selections of dwelling districts from the two cities are based on amount of the facilities maintaining the wealth and living area same to do the questionnaires. One hundred aged people are selected in the each dwelling district to fill out the questionnaires, and 386 valid questionnaires are finally obtained. The data obtained from the questionnaires are used to do some statistic analysis by using SPSS24.0 program. The results are shown as following: In the case of same amount of neighborhood facility for dwelling district, the aged people living in a flat ground use the facility more frequently and communicate more often with their friends and neighbors than the aged people living in a mountain region do, the social network forms more easily as well. In the other case of same topography dwelling districts, the aged people living in an abundant facility dwelling district use the facility more frequently and communicate more with their neighbors and friends than the aged people living in a mountain region do, so the social network forms more easily as well. Thus it can be seen that topography and amount of facility are significant influence factors of the aged social network formation.

출산 여성의 산후관리서비스 이용에 영향을 미치는 요인 (Factors Affecting the Use of Postpartum Care Services)

  • 정윤선;권영대
    • 보건의료산업학회지
    • /
    • 제11권1호
    • /
    • pp.143-158
    • /
    • 2017
  • Objectives : This study aims to analyze differences in the use of postpartum care services and identify the factors affecting their use. Methods : Data were collected from the 2008-2014 Korean Health Panel. Chi-square tests were conducted to analyze differences in the characteristics of women after birth by the use of postpartum care services. Logistic regression analysis was used to identify factors affecting the use of each type of postpartum care service. Results : Participants with higher education and household income levels were more likely to use a postpartum care facility. Individuals with a lower number of household members, who gave birth in 2011-2013, and who used hospitals specializing in obstetrics and gynecology had a greater likelihood of using a postpartum care facility. The probability of using a postpartum caretaker was higher when participants did not perform any economic activities. Conclusions : It is meaningful to confirm that use patterns and determinants of postpartum care facilities and postpartum caretakers are completely different and that the socioeconomic status of women affects the utilization of postpartum care facilities.

GIS를 이용한 대학시설물 관리시스템 개발 - 경북대학교를 중심으로 - (Development of Campus Facility Management System using GIS - Focused on Kyungpook National University -)

  • 이승엽;임용호;최현상
    • 한국지리정보학회지
    • /
    • 제1권1호
    • /
    • pp.18-27
    • /
    • 1998
  • 본 연구는 GIS를 이용하여 대학시설물 관리시스템의 개발을 수행한 결과를 다룬 것으로 시설물 관리에 GIS를 적용했을때의 장, 단점과 시스템의 개발과정에 대해 설명하고자 한다. 먼저, 시설물 관리란 사람들과 조직의 작업을 물리적인 작업공간과 하나로 통합하는 작업으로 볼 수 있다. 오늘날 시설물의 관리비용이 높아지고 합리적인 관리가 요구되기에, 이러한 조직들은 기존의 시설과 집기의 사용을 최대한 활용함으로써 더 이상의 불필요한 투자를 방지할 필요가 생겼다. 이러한 관점에서 본 연구의 목적은 GIS를 이용한 대학 시설물 관리 시스템 구축하는데 있다. 먼저 국립지리원의 1/5,000지도와 1/600의 측량도를 바탕으로 베이스 맵을 구축하고 제나시스의 제니어스 프로그램을 이용하여 학교내 각종 시설물관리 시스템을 개발하였다. 본 시스템은 지형정보관리, 지하매설물관리 그리고 시설물 관리의 3가지로 구분되며 각각의 속성정보를 이용함으로서 현재의 합리적인 관리뿐만 아니라 미래 지향적인 개발의 방향을 제시할 수 있다.

Uncertified Facility (BSL 2 plus): Its Journey through Life for Preparations and Setting up, Compliance with Biosafety Regulations, Implementation, and Registration of the Facility with the Ministry of Health, Singapore

  • Tun, Tin;Sim, Xander
    • 대한임상검사과학회지
    • /
    • 제53권1호
    • /
    • pp.68-80
    • /
    • 2021
  • An uncertified facility is a facility not certified, as defined in the Biological Agents and Toxins Act (BATA) in Singapore, but has met the requirements of the Ministry of Health to possess First and Fifth Schedule biological agents and toxins. This type of facility is also known as a Biosafety Level 2 Plus (BSL 2+) facility. Registration as an uncertified facility or a BSL 2+ facility requires a certain process and procedure to be sought with the Biosafety Branch of the ministry. This review, shares first-hand knowledge on the journey to achieving registration of the authors' facility. The procedure involved considerable preparation, setting up facility requirements, biosafety precautions, procedures and practices, and training and competence of laboratory users. The ministry conducted a thorough onsite facility audit to ensure that the facility requirements and biosafety procedures and practices were in place. It then issued an approval letter of possession for the first-time use of biological agents and registered the laboratory as an uncertified facility. The expectation is that the comprehensive information shared may be of great benefit to other facilities with similar interests.

낙후 도심지역의 교육시설 재구성을 위한 연구 - 경북 포항시 장량.중앙지구 초등학교시설 복합화 방안 - (A Study on the Reformation Plan for School Facilities in Depressed Downtown Area - Mixed Use Rebuilding Plan for Elementary School Facilities in Jang-Ryang and Joong-Ang Dong Areas in Pohang, Kyoungsangbukdo -)

  • 유승애;이대준
    • 교육시설
    • /
    • 제14권3호
    • /
    • pp.36-46
    • /
    • 2007
  • This study is based on the need to reform mixed use plan of school facilities considering the characteristics of depressed downtown area. It started with the object to make a plan by deducting function of place required and corresponded to the characteristics of depressed downtown area in Pohang city. As the result of researching present status and the characteristics of six elementary schools in Pohang which the number of student has decreased, it is found that they are required to have change in the region of depressed downtown area which have fallen behind and obsolete school facilities which idle classrooms have increased and to have reformations of a city are characterized by 5 types as poor life environment, lack of cultural facilities as community institution, poor open-space and ecological environment, non-activation of conventional market and contraction of commerce industry by outflow of industry, transfer of administration operation function and etc. and the region of school under researching shows these characteristics. I planed the mixed use program with factors of local community facility, status of school facility use and depressed area's characteristics. Finally, I propose the mixed use plan of school facilities as the strong point of sustainable development which influences on and be influenced by regional characteristics and structure of city.

BIM Application Process for Facility Condition Assessment Documentation Work

  • Yoo, Seung Eun;Yu, Jung Ho
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.268-270
    • /
    • 2015
  • Overseas countries' government and facility management industries make efforts to ensure precise and fluent data from building information modeling (BIM). In facility management, a large amount of data and information are necessary to continue the process activities. Facility condition assessment, which is performed to make budget plan for the maintenance and operation requires the related facilities' documentation and information. However, it depends on the owner and the user of the facility to provide accurate and complete information to consultant. The problems as follows: (1) owner and user should provide documents and information, and (2) the consultant cannot verify the provided information. To solve these problems, we suggest a methodology to produce the information for FCA through BIM. First, all of the essential documentation and assessment elements are listed. Next, the documents and elements are separated out, whether they are able to be extracted from BIM or not. Then, the list indicates only the data that is linked with BIM. The suggestion is expected to provide the required information through the connection to BIM with accuracy and completeness and to present another BIM application use for facility management.

  • PDF

Development of the Control System for Fast-Responding Frequency Regulation in Power Systems using Large-Scale Energy Storage Systems

  • Lim, Geon-Pyo;Park, Chan-Wook;Labios, Remund;Yoon, Yong-Beom
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.9-13
    • /
    • 2015
  • Energy storage systems (ESS) can be used to provide frequency regulation services in a power system to replace traditional frequency regulation power plants. Battery ESS, in particular, can provide "fast-responding frequency regulation," wherein the facility can respond immediately and accurately to the frequency regulation signal sent by the system operator. This paper presents the development and the trial run results of a frequency regulation control system that uses large-scale ESS for use in a large power system. The control system was developed initially for the 4 MW ESS demonstration facility in Jocheon Jeju Island, and was further developed for use in the 28 MW ESS facility at the Seo-Anseong substation and the 24 MW ESS facility at the Shin-Yongin substation to provide frequency regulation services within mainland Korea. The ESS facility in Seo-Anseong substation responds to a sudden drop in frequency via governor-free control, while the ESS facility in Shin-Yongin responds via automatic generator control (AGC).

아파트 단지의 전력감시반 개선 연구 (A Study on the Improvement of Electric Supervisory in Apartment Complex)

  • 홍규장;김채규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.51-54
    • /
    • 1993
  • In this paper, it is proposed the the SCADA(Supervisory control and Data Acquisition) system in Apartment complex. The proposed SCADA system make use of the computer CRT(Cathod RAy Tube), which automatically observe the Electrical Facility, Elvator Facility, Fire Alarm Facility and process in the real-time data. In order to improve the hardware performance and the information process, the SCADA system composed of master-slave topology and decentralized the supervisory Facility. This system is expected the retrenchment of construction expenditure and the level-up of supervisory execution.

  • PDF

다목적강당의 계획과 활용에 관한 연구 - 가변성 적용을 중심으로 - (A Study on Design and Practical Use of Multi-purpose Auditorium with Priority given to Variable Application in Educational Facility)

  • 지현정;이정란;이상홍
    • 교육시설
    • /
    • 제12권6호
    • /
    • pp.5-17
    • /
    • 2005
  • The purpose of the study is to propose architectural design standards of the Multi-purpose Auditorium planning in educational facilities. The success of the design is measured by how well variable elements are applied to parts of Multi-purpose Auditorium and designed and equipped so that all groups-amateurs, professionals, youth, and adult alike-may use it effectively. The use of this facility will extend over a wide range, including concerts, plays, motion pictures, forums, and other forms of presentation. The wall, stage, roof, windows, and furnitures are important parts of Multi-purpose Auditorium and variable elements can applied to these parts. To successfully application of variable elements, it is necessary that these elements are considered in planning phase including time schedule planning. Various elements are permit a more informal and flexible arrangement and extensive learning activity.

Ontology-based Facility Maintenance Information Integration Model using IFC-based BIM data

  • Kim, Karam;Yu, Jungho
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.280-283
    • /
    • 2015
  • Many construction projects have used the building information modeling (BIM) extensively considering data interoperability throughout the projects' lifecycles. However, the current approach, which is to collect the data required to support facility maintenance system (FMS) has a significant shortcoming in that there are various individual pieces of information to represent the performance of the facility and the condition of each of the elements of the facility. Since a heterogeneous external database could be used to manage a construction project, all of the conditions related to the building cannot be included in an integrated BIM-based building model for data exchange. In this paper, we proposed an ontology-based facility maintenance information model to integrate multiple, related pieces of information on the construction project using industry foundation classesbased (IFC-based) BIM data. The proposed process will enable the engineers who are responsible for facility management to use a BIM-based model directly in the FMS-based work process without having to do additional data input. The proposed process can help ensure that the management of FMS information is more accurate and reliable.

  • PDF