• Title/Summary/Keyword: Use Intensity

Search Result 1,556, Processing Time 0.029 seconds

Sound Intensity Measurement for Characteristics of Two Microphone Arrangements. (두 개의 Microphone 배열 특성에 의한 음향 Intensity 측정)

  • 장호경
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1985.10a
    • /
    • pp.37-42
    • /
    • 1985
  • The errors caused by developmental finite difference approximations in the two microphone acoustic intensity measurement technique are considered in this paper. The frequencies and pressure responses obtained experimentally, are presented for both face to face (FF) and side by side(SS) microphone configurations. The implications of these results by the use of such a cofiguration for two microphone sound intensity measurement are discussed.

  • PDF

Obstacle Avoidance of Indoor Mobile Robot using RGB-D Image Intensity (RGB-D 이미지 인텐시티를 이용한 실내 모바일 로봇 장애물 회피)

  • Kwon, Ki-Hyeon;Lee, Hyung-Bong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.10
    • /
    • pp.35-42
    • /
    • 2014
  • It is possible to improve the obstacle avoidance capability by training and recognizing the obstacles which is in certain indoor environment. We propose the technique that use underlying intensity value along with intensity map from RGB-D image which is derived from stereo vision Kinect sensor and recognize an obstacle within constant distance. We test and experiment the accuracy and execution time of the pattern recognition algorithms like PCA, ICA, LDA, SVM to show the recognition possibility of it. From the comparison experiment between RGB-D data and intensity data, RGB-D data got 4.2% better accuracy rate than intensity data but intensity data got 29% and 31% faster than RGB-D in terms of training time and intensity data got 70% and 33% faster than RGB-D in terms of testing time for LDA and SVM, respectively. So, LDA, SVM have good accuracy and better training/testing time to use for obstacle avoidance based on intensity dataset of mobile robot.

Estimation of Pollutants Loading from Non-Point Sources Based on Rainfall Event and Land use Characteristics (강우강도와 토지이용을 고려한 비점오염물질 부하량 산정에 관한 연구)

  • Lee, Hye-Won;Choi, Nam-Hee;Lee, Yong-Seok;Choi, Jung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.8
    • /
    • pp.572-577
    • /
    • 2011
  • The unit load has simply been used to estimate total pollutant loading from non-point sources, however, it does not count on the variable pollutant loading according to land use characteristics and rainfall intensity. Since pollutant emission from the watershed is strongly dependent on the rainfall intensity, it is necessary to find out the relationship between pollutant loading and rainfall intensity. The objective of this study is to develop simple and easy method to compute non-point source pollution loads with consideration of rainfall intensity. Two non-point source removal facility at Gyeongan-dong (Gwangju-si) and Mohyeon-myeon (Yongin-si), Gyeonggi-do was selected to monitor total rainfall, rainfall intensity, runoff characteristics and water quality from June to November, 2010. Most of Event Mean Concentrations (EMC) of measured water quality data were higher in Gyeongan which has urban land use than in Mohyeon which has rural land use. For the case of TP (Total Phosphorus), Mohyeon has higher values by the influence of larger chemical uses such as fertilizer. The relationship between non-point source pollution load and rainfall intensity is perfectly well explained by cubic regression with 0.33~0.81 coefficients of determination($R^2$). It is expected that the pollution loading function based on the long-term monitoring would be very useful with good accuracy in computing non-point source pollution load, where a rainfall intensity is highly variable.

Measurement of Near Field Sound Intensity and Loss Factor Using Plate Intensity Measurement (평판 인텐시티 측정을 통한 근접장 음향 인텐시티와 손실 계수 측정법)

  • 김용조;김양한
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.589-596
    • /
    • 1997
  • A energy equation for a thin plate and surrounding fluid is derived. The equation essentially determines the relation between internal loss of thin plate, energy of acoustic radiation, and structure intensity. We attempted to use this relation to measure internal loss of thin plate. The significance of this approach is that internal loss at any point of a thin plate can be measured. The quality of this measure is dicated by the accuracy of associated measurement systems such as structure and acoustic intensity measurements. A strain gauge bridge system has been developed to measure structure intensity of thin plate. Its performance is tested by experiments.

  • PDF

REMARKS ON FINITE ELEMENT METHODS FOR CORNER SINGULARITIES USING SIF

  • Kim, Seokchan;Kong, Soo Ryun
    • Honam Mathematical Journal
    • /
    • v.38 no.3
    • /
    • pp.661-674
    • /
    • 2016
  • In [15] they introduced a new finite element method for accurate numerical solutions of Poisson equations with corner singularities, which is useful for the problem with known stress intensity factor. They consider the Poisson equations with homogeneous Dirichlet boundary condition, compute the finite element solution using standard FEM and use the extraction formula to compute the stress intensity factor, then they pose a PDE with a regular solution by imposing the nonhomogeneous boundary condition using the computed stress intensity factor, which converges with optimal speed. From the solution we could get accurate solution just by adding the singular part. This approach works for the case when we have the accurate stress intensity factor. In this paper we consider Poisson equations with mixed boundary conditions and show the method depends the accrucy of the stress intensity factor by considering two algorithms.

A FINITE ELEMENT METHOD USING SIF FOR CORNER SINGULARITIES WITH AN NEUMANN BOUNDARY CONDITION

  • Kim, Seokchan;Woo, Gyungsoo
    • East Asian mathematical journal
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • In [8] they introduced a new finite element method for accurate numerical solutions of Poisson equations with corner singularities, which is useful for the problem with known stress intensity factor. They consider the Poisson equations with homogeneous Dirichlet boundary condition, compute the finite element solution using standard FEM and use the extraction formula to compute the stress intensity factor, then they pose a PDE with a regular solution by imposing the nonhomogeneous boundary condition using the computed stress intensity factor, which converges with optimal speed. From the solution they could get accurate solution just by adding the singular part. This approach works for the case when we have the reasonably accurate stress intensity factor. In this paper we consider Poisson equations defined on a domain with a concave corner with Neumann boundary conditions. First we compute the stress intensity factor using the extraction formular, then find the regular part of the solution and the solution.

Placing Constrained Layer Damping Patches Using Reactive Shearing Structural Intensity in Order to Reduce the Radiated Sound Power of a Air-Conditioner Outdoor Unit (반동 전단 구조 인텐서티 측정에 의한 제진재 적용과 그에 따른 에어컨 실외기 구조 방사 소음 저감)

  • 김규식;강연준;진심원;정인화;이정우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.333-337
    • /
    • 2003
  • The use of reactive shearing structural intensity to place small patches of constrained layer damping material in order to achieve the largest reduction in the radiated sound power of Air-conditioner outdoor unit is described. The normal surface velocity of each panel was measured using a laser doppler vibrometer. Experimental results indicated that patches of constrained layer damping material placed over areas of high reactive structural intensity reduced the radiated sound power significantly more than patches of the same area placed over areas of low reactive structural intensity

  • PDF

Albumin-conjugated Cadmium Sulfide Nanoparticles and their Interaction with KB Cells

  • Selim, K.M. Kamruzzaman;Kang, Inn-Kyu;Guo, Haiqing
    • Macromolecular Research
    • /
    • v.17 no.6
    • /
    • pp.403-410
    • /
    • 2009
  • Cytotoxicity is a severe problem of cadmium sulfide nanoparticles(CSNPs) for use in biological systems. In the present study, mercaptoacetic acid-coated CSNPs were conjugated with bovine serum albumin (BSA) to improve biocompatibility. The surface properties of the CSNPs and albumin-conjugated CSNPs (ACSNPs) were characterized by XRD, UV, FTIR, EA, TEM and DLS. Human breast cancer cells (KB cells) were then cultured in the presence of the nanoparticles to evaluate the cytotoxicity of CSNPs and ACSNPs. Finally, the fluorescence intensity of the nanoparticles' aqueous solution was examined using a fluorescence spectrometer. The results showed that the cell compatibility and fluorescence intensity of ACSNPs were higher than those of CSNPs. The strongly luminescent features of the biocompatible ACSNPs are promising for use in biological fields such as cellular labeling, intracellular tracking and molecular imaging.

Correlation Analysis between Space Integration and Natural Light in K Senior Hospitals (K 노인전문병원의 공간 통합도와 자연광의 상관관계 분석)

  • Moon, Sun-Young;Lee, Hyun-Soo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.2
    • /
    • pp.189-196
    • /
    • 2015
  • In case of Senior Hospitals, meticulous care is required in both amount and quality of natural lighting because of the semi-long term residence of patients. Natural lighting has a huge impact on the physical and psychological part for the seniors. Likewise, natural lighting is an important factor considered for hospital design because it can also effect hospitalization period of patients. Research subject was K Senior Hospital which was determined as the courtyard-type building made to provide healing environment through natural lighting. Analysis was performed by dividing the space of K Senior Hospital into Central Treatment Department directly used by patients, Outpatient Department(OPD), Ward Department, Common Use Department. Research was carried out in two ways of integration value analysis using SPACE SYNTAX and illumination intensity analysis using ECOTECT. K Senior Hospital intended to actively let in natural light through courtyard and to make patients exposed to natural light when they walk along the circuit corridor built around the courtyard. This environmental consideration affected the utilization rate of Common Use Department and residence time of patients raising the average of Common Use Department on every floor. As a resuit of this study presenting type C and type D, part of four types of illumination intensity, takes higher percentage of almost every spaces compare to the others therefore K Senior Hospital was designed on the assumption of healing environment composition through natural light. The result of this research would be used meaningfully in the space programming phase of Senior Hospitals in the future. Utilization rate can be adjusted using illumination intensity value in the space that integration rate should be planed to be high. The use(purpose) of space and integration rate can be used as a guideline to set illumination intensity of natural.

Development of Evaluation Indices for Preservation Strategies for Agricultural Reservoir Watersheds (농업용 저수지 유역의 보전전략 수립을 위한 특성평가지표 개발)

  • Jang, Byoung-Kwan;Whang, Bo-Chul;Hwang, Kook-Woong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.6
    • /
    • pp.14-20
    • /
    • 2008
  • The agricultural reservoir watershed plan suggests three specific indices or ways to measure the potential for maintaining reservoir quality in balance with existing or proposed uses: an index of the reservoir's vulnerability to accelerated eutrophication, an index of the degree of land use intensity in reservoir watersheds, and an index of present water quality. Three items that contribute to reservoir eutrophication are included in the vulnerability index: the ratio of reservoir volume to drainage-basin area, shoreline configuration, and mean depth. The watershed land-use intensity index is based on road proximity and upland watershed land-use intensity. Water quality can be given a COD level. All six indicators are considered separately and then rated as follow: low (1), medium (2), or high (3). Five out of 30survey sites were less than 8points, 17sites were less than 11points and 8sites were less than 14points. This study suggests that the sites in the first ranking were potential areas for preservation, sites in the second ranking were potential areas for environmental friendly planning and sites in the third ranking were potential areas for residential need oriented planning. The advantage of this study is the low cost of gathering data for the development of local policy for the planning, management and protection of reservoir basin.