• Title/Summary/Keyword: Urine analysis

Search Result 768, Processing Time 0.025 seconds

Unilateral Renal Subcapsular Abscess Associated with Pyelonephritis in a Cat (고양이의 신우신염을 동반한 편측신장의 피막하 농포 증례)

  • Lee, Hye-Yeon;Chang, Jin-Hwa;Jung, Joo-Hyun;Oh, Sun-Kyung;Kim, Jae-Hong;Kim, Wan-Hee;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.27 no.1
    • /
    • pp.79-82
    • /
    • 2010
  • A 1-year-old intact male Russian blue cat was admitted with a history of depression, partial anorexia, vomiting and dysuria. Through the blood analysis, ultrasonography and urinalysis, this cat was diagnosed as feline lower urinary tract disease with cystitis. Despite antibiotic therapy the cat showed stranguria and urinary catheterization were repeated several times. One week after, this patient appeared depression, hyperthermia and leukocytosis. Ultrasonography revealed a small amount of hypoechoic fluid around the right kidney and bacteria were found in the urine. The amount of the right subcapsular fluid was increased and bacteria were found in the fluid. On the excretory urography, leakage of contrast media were detected. The right kidney was surgically removed and suppurative fluid between the renal parenchyma and the thickened capsule was identified. After surgery, subcapsular abscess of the right kidney associated with pyelonephritis was confirmed histologically and this cat recovered without complications.

A Rapid Method for Estimating the Levels of Urinary Thiobarbituric Acid Reactive Substances for Environmental Epidemiologic Survey

  • Kil, Han-Na;Eom, Sang-Yong;Park, Jung-Duck;Kawamoto, Toshihiro;Kim, Yong-Dae;Kim, Heon
    • Toxicological Research
    • /
    • v.30 no.1
    • /
    • pp.7-11
    • /
    • 2014
  • Malondialdehyde (MDA), used as an oxidative stress marker, is commonly assayed by measuring the thiobarbituric acid reactive substances (TBARS) using HPLC, as an indicator of the MDA concentration. Since the HPLC method, though highly specific, is time-consuming and expensive, usually it is not suitable for the rapid test in large-scale environmental epidemiologic surveys. The purpose of this study is to develop a simple and rapid method for estimating TBARS levels by using a multiple regression equation that includes TBARS levels measured with a microplate reader as an independent variable. Twelve hour urine samples were obtained from 715 subjects. The concentration of TBARS was measured at three different wavelengths (fluorescence: ${\lambda}-_{ex}$ 530 nm and ${\lambda}-_{em}$ 550 nm; ${\lambda}-_{ex}$ 515 nm and ${\lambda}-_{em}$ 553 nm; and absorbance: 532 nm) using microplate reader as well as HPLC. 500 samples were used to develop a regression equation, and the remaining 215 samples were used to evaluate the validity of the regression analysis. The induced multiple regression equation is as follows: TBARS level (${\mu}M$) = -0.282 + 1.830 ${\times}$ (TBARS level measured with a microplate reader at the fluorescence wavelengths ${\lambda}-_{ex}$ 530 nm and ${\lambda}-_{em}$ 550 nm, ${\mu}M$) -0.685 ${\times}$ (TBARS level measured with a microplate reader at the fluorescence wavelengths ${\lambda}-_{ex}$ 515 nm and ${\lambda}-_{em}$ 553 nm, ${\mu}M$) + 0.035 ${\times}$ (TBARS level measured with a microplate reader at the absorbance wavelength 532 nm, ${\mu}M$). The estimated TBARS levels showed a better correlation with, and are closer to, the corresponding TBARS levels measured by HPLC compared to the values obtained by the microplate method. The TBARS estimation method reported here is simple and rapid, and that is generally in concordance with HPLC measurements. This method might be a useful tool for monitoring of urinary TBARS level in environmental epidemiologic surveys with large sample sizes.

Low Dose Exposure to Di-2-Ethylhexylphthalate in Juvenile Rats Alters the Expression of Genes Related with Thyroid Hormone Regulation

  • Kim, Minjeong;Jeong, Ji Seong;Kim, Hyunji;Hwang, Seungwoo;Park, Il-Hyun;Lee, Byung-Chul;Yoon, Sung Il;Jee, Sun Ha;Nam, Ki Taek;Lim, Kyung-Min
    • Biomolecules & Therapeutics
    • /
    • v.26 no.5
    • /
    • pp.512-519
    • /
    • 2018
  • Phthalates widely used in the manufacture of plastics have deeply penetrated into our everyday lives. Recently, a concern over the toxicity of phthalates on thyroid, has been raised but in most of cases, the doses employed were unrealistically high. To investigate the effects of phthalates on thyroid, we investigated the effects of the repeated oral exposure to low to high doses (0.3, 3, 30 and 150 mg/kg) di-2-ethylhexylphthalate (DEHP) from weaning to maturity for 90 days in juvenile rats on the thyroid. The histological examination revealed that DEHP significantly induced hyperplasia in the thyroid from the doses of 30 mg/kg, which was confirmed with Ki67 staining. In line with this finding, increased mRNA expression of thyrotropin releasing hormone (Trh) was observed in the thyroid of female at 0.3 mg/kg and 150 mg/kg as determined by RNAseq analysis. Moreover, significantly increased expression of parathyroid hormone (Pth) in the female at 0.3 mg/kg, and thyroglobulin (Tg) and thyroid hormone responsive (Thrsp) in the male at 0.3 mg/kg were noted in the blood, of which changes were substantially attenuated at 150 m/kg, alluding the meaningful effects of low dose DEHP on the thyroid hormone regulation. Urinary excretion of mono-2-ethylhexyl-phthalate (MEHP), a major metabolite of DEHP was determined to be 4.10 and 12.26 ppb in male, 6.65 and 324 ppb in female at 0.3 and 30 mg/kg DEHP, respectively, which fell within reported human urine levels. Collectively, these results suggest a potential adverse effects of low dose phthalates on the thyroid.

The Value of Isotope Nephrography in Carcinoma of Cervix - Follow up Studies of Pre and Post Irradiation (자궁경부암(子宮頸部癌) 방사선치료(放射線治療) 전후(前後) Renogram의 의의(意義))

  • Yoo, H.S.;Suh, J.H.;Park, C.Y.;Choi, B.S.;Jung, S.O.;Kwak, H.M.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.9 no.1
    • /
    • pp.51-58
    • /
    • 1975
  • It is a great value to find an early detection of involvement of ureteric obstruction in the carcinoma of cervix. Little or no knowledge of the condition of the kidneys or the lower urinary tract are able to elucidate by the biochemical studies such as blood nitrogen or urine creatinine in carcinoma of cervix. Findings of urography delineates the condition of urinary tract stasis in the renal pelvis and ureters, however, slight stasis maybe difficult to demonstrate. On the other hand isotope nephrography is accepted as a sensitive method to observe renal function especially in regarding to the excretory function of kidney. It was attempted to analysis the findings of urography conjunction with isotope nephrography in 50 cases of unselected patients with invasive carcinoma of cervix through pre and post irradiation follow up studies. Urography was done as a routine procedure and.analysed emphasising changes of collecting systems and ureter condition. Isotope nephrography was carried out by means of $15{\mu}ci\;I^{131}$-Hippuran injected intravenously and the curves were analysed as follows. Parameter were; time of maximum amplitude ($T_{max}$), half time of maximum amplitude ($T\frac{1}{2}$), Kac and Kex value calculated from these two parameters in Tobe's method. The excretion index by Aurell defines the ratio between the maximum activity and the activity measured on the slope of the third phase ten minites after it has reached its maximum. Results: 1. 28.8% had an abnormal IVP suggestive of ureteric involvement before irradiation therapy and the patient of stage III and IV were the great part. 2. 21.7% had abnormal findings of per-irradiation renogram whom showed normal IVP. The other group showed normal IVP which group also showed normal renogram prior irradiation. 3. The more severe the ureteric involvement, the change of excretion index was greater. 4. Even in stage I and II patient, abnormal renogram was revealed in 12 cases (39.4%) among 31 cases. 5. All cases of TAH showed abnormal findings of IVP and renogram. 6. No. definite change of renogram was obtained just after the irradiation therapy (point $A:8000{\sim}9000rads,\;B:5000{\sim}6000rads,\;Co:11000{\sim}13000rads$). Each 3 month follow up study was performed and comparing with preirradiation study which showed significant changes of excretion index of renogram were 42.8% in $6{\sim}9$ month follow-up and 75% in $9{\sim}12$ month, respectively. 7. It seems to be important to observe the parameter Kex and excretion index of renogram to determine early abnormality of kidney excretory function by means of post-irradiation follow up study.

  • PDF

Analysis on Urinary N-methylformamide of Korean Workers according to Industrial Classification and Countermeasures for Exposure Control of N,N-dimethylformamide (우리나라 근로자들의 업종별 뇨중 N-methylformamide 분석 및 N,N-dimethylformamide 노출관리 대책)

  • Kim, Dohyung;Byun, Kiwhan;Park, Jae-Oh;Lee, Mi-Young;Kim, Eun-A
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.345-352
    • /
    • 2014
  • Objectives: This study is aimed to describe the current situation about urinary biomarker N-methylformamide(NMF) for workers exposed to N,N-dimethylformamide(DMF) according to industrial classification. Materials: Special health examination records of the workers who had undergone urinary biological monitoring in 2013 were collected. The numbers and percentage of workers, whose urinary NMF values were above the limit of detection(LOD) and above the biological exposure index(BEI) were calculated. Health relatedness with DMF as judged by their doctors was also described. All description was classified according to the $9^{th}$ Korean Standard Industrial Classification(KSIC). Results: It appeared that most workers exposed to DMF belong to manufacturing section(80.7%). The geometric mean(GM) values of urinary NMF were 6.25 mg/L, 3.54, and 3.86 for the manufacturing section, professional, scientific and technical activities section, and for the construction section respectively. In detail, it seemed that division of textiles(except apparel) (GM 7.51 mg/L), division of leather, luggage and footwear(11.59 mg/L), and division of rubber and plastic products(6.89 mg/L) were highly exposed to DMF with a high percentage of workers with urinary NMF values above BEI. This was probably due to the effect of skin absorption that the division of leather, luggage and footwear showed the highest urine NMF GM. Conclusions: It seemed that workers in manufacture industries such as textile, leather, luggage, footwear, rubber and plastic products were highly exposed to DMF. So, efforts should be focused on those industries in order to effectively diminish worker's exposure. Further studies to compare DMF air-monitoring with bio-monitoring according to industrial classification should be considered.

Quantification of urea in serum by isotope dilution HPLC/MS (동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량)

  • Lee, Hwashim;Park, Sangryoul
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 2005
  • Urea in blood has been measured as an effective marker for diagnosis of renal function. Urea which is e end-product of nitrogen containing metabolites such as proteins is filtered through glomeruli of kidneys and then excreted as urine. If the renal function is deteriorated, the urea concentration in blood will be increased, from which the healthiness of renal function is judged. In order to improve the confidence of diagnosis results, the results must keep traceability chain to certified reference materials, which was certified by primary reference method. In this study, we proposed isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) as a candidate primary method, in which $15^N_2$-urea is used as an internal reference material. The developed method is highly accurate in principle and is convenient as it does not require cumbersome derivatization. 0.1 mmol/L ammonium chloride was selected as a mobile phase for HPLC because it provided low interference in MS analysis of relatively low molecular weighted urea. HPLC and MS were connected with an electrospray ionization (ESI) interface of positive mode, which provided high sensitivity and reproducibility. The developed method was validated with internationally recognized reference materials, and we have obtained satisfactory results in an international ring trial. The expanded uncertainty calculated according to ISO guide was 1.8% at 95% confidence interval. The developed method is being used as a primary reference measurement method such as for certification of serum certified reference materials (CRMs).

Gastrointestinal and Hepatic First-pass Effects of Triflusal in Rats (흰쥐에서 트리플루살의 위장관 및 간 초회통과효과)

  • Cho, Hea-Young;Jeong, Tae-Jin;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.4
    • /
    • pp.265-271
    • /
    • 2001
  • In order to elucidate the influence of intestinal and hepatic first-pass effect on the pharmacokinetics of triflusal, the biotransformation of triflusal in the gastrointestinal tract and liver was designed. Moreover, we tried to establish an HPLC method applicable for bioassay and available to pharmacokinetics, not only with the simultaneous determination of triflusal and its active metabolite, 2-hydroxy-4-trifluoromethyl benzoic acid (HTB), but also with improving sensitivity. After the administration of triflusal (10 mg/kg) and HTB (10 mg/kg) into femoral vein, portal vein (only triflusal) and oral route (only triflusal), pharmacokinetic parameters were investigated from the plasma concentration-time profiles of triflusal and HTB in rats. An HPLC method was developed for the simultaneous determination of triflusal and HTB in rat plasma, urine and bile. The HPLC analysis was carried out using a C18 column and acetonitrile-methanol-water (25:10:65, v/v/v) as the mobile phase and UV detection at 234 nm. Furosemide was used as the internal standard. The calibration curves were linear over the concentration range $0.05-5.0\;{\mu}g/ml$ for triflusal and $0.2-200.0\;{\mu}g/ml$ for HTB with correlation coefficients greater than 0.999 and with intra-day or inter-day coefficients of variation not exceeding 10.0%. This assay procedure was applied to the study of metabolite pharmacokinetics of triflusal and HTB in rats. It was supposed that triflusal was almost metabolized in vivo because urinary and biliary excreted amounts of triflusal could be ignored as it was lower than 1.2% of the administered dose. According to the gastrointestinal and hepatic biotransformation pathways of triflusal, it was found that triflusal was hydrolyzed by about 5% in intestine and metabolized by about 53% in liver, and that the bioavailability of triflusal after oral administration of triflusal was 0.44, and also that the fraction of total elimination rate of triflusal which formed HTB in liver $(F_{mi},\;%)$ was about 98%. These results showed that triflusal was almost metabolized in liver, and the total elimination of triflusal in the body was dependent to the formation rate of HTB from triflusal in liver.

  • PDF

Pharmacokinetics of Anticancer Agent SB-31 in Rats & Rabbits and the Cardiovascular Effect on the Isolated Perfused Rat Heart & Blood Coagulation (SB-31의 Glycyrrhizin을 지표로 한 Rat과 Rabbit에서의 약물동태 및 심혈관계에 대한 효과 연구)

  • Kang, Won Ku;Park, Yong Soon;Lee, Dong Heum;Kwon, Kwang Il
    • Korean Journal of Clinical Pharmacy
    • /
    • v.8 no.2
    • /
    • pp.122-132
    • /
    • 1998
  • SB-31 which contains Pursatilla, Licoris and Ginseng extracts was recently proved as an anticancer agent. In a preclinical effort to be applied this drug to human, pharmacokinetics of SB-31 was carried out in rats and rabbits. Glycyrrhizin(GZ), a saponin of Licoris was used as a standard ingradient for the pharmacokinetics of SB-31. The rat's blood, bile and urine samples were serially collected in femoral vein, common bile duct and bladder, respectively, after bolus i.v. injection at a dose of 1 or 1/5 ampul/rat and rabbit's blood samples from the marginal ear vein at a dose of 1 or 3 amp./rabbit. GZ and glycyrrhetic acid(GA), a major metabolite of GZ in the physiological samples were analysed by HPLC with UV detection. The decline of GZ in plasma concentration was generally biexponential at each dose. GZ was almost completely recovered in bile within 18 hour. GA wasn't detected in the samples with UV detector. In the rat, Vss and Kel at a dose of 1 and 1/5 ampul of SB-31 were $98.06\pm6.07\;ml,\;0.33\pm0.05\;hr^{-1}\;and\;65.46\pm11.19\;ml,\;0.68\pm0.25\;hr^{-1}$, respectively. Those in rabbits at a dose of 3 and 1 ampul of SB-31 were $235.24\pm30.72\;ml,\;0.13\pm0.36\;hr^{-1}\;and\;341.32\pm28.58\;ml,\;0.27\pm0.04\;hr^{-1}$, respectively. 'WinNonlin' was utilized for the compartmental analysis. A two-compartment model was chosen as the most appropriate pbarmaco-kinetic model. The data were best described by using a weighting factor of $1/y^2$. To evaluate the effect of SB-31 on cardiovascular system, serially diluted SB-31 was directly injected into coronary artery in the isolated perfused rat heart and the effect of PSF, PSH, saponins of Pursatilla, and SB-31 on PT, APTT of healthy human plasma was examined. Except the positive inotropic effect of ten times diluted solution of SB-31, there was no significant effect on LVDP, (- dp/dt)/(+dp/dt), heart rate and coronary flow in comparision with that of vehicle. SB-31 had no effect on PT but slightly delayed APTT about $6.9{\sim}11.5\%$. There was no significant effect of PSF and PSH on PT & APTT. Conclusively, SB-31 did not show any notable toxic effects on cardiovascular system.

  • PDF

An Experimental Study on the Occurence of Bacteriuria according to Duration of Insertion, Frequency of Bladder Irrigation & Perineal Care, & Administration of Antibiotics in Patients with Indwelling Catheter (수직도뇨관환자의 요로감염발생요인에 관한 실험적 연구 -요관삽입기간, 삽입방법, 세척횟수, 회음부소독유무, 항생제사용유무를 중심으로 -)

  • 임난영;김분한
    • Journal of Korean Academy of Nursing
    • /
    • v.11 no.1
    • /
    • pp.19-27
    • /
    • 1981
  • This Study was conducted at Intensive Care Unit of H & S Hospitals from Jan 4 to April 7, 1981 on 14mail & 26female adult patients. Each patient was screened and found to have nonbacteriuria in clean catch specimen before catheterization. Clean catch apecimen through Foley catheter were obtained after 24hours, 48hours and 72hours from catheterization. The result of this study is reviewed in a statistical analysis of percentage & Chi Square test to obtain the following findings. 1) The occurenc of bacteriuria in patients according to duration of indwelling catheter. a. 9.1% of the patient showed evidence of bacteriuria 24hours post catheterization specimen and 60% showed 48hours post cathetreization, while 68.4% of the patient showed evidence of bacteriuria 72hours post catheterization specimen. The occurence of bacteriuria in patients were significant differences at 1% level between duration of indwelling catheter. b. Mail patients had no infection 24hours post catheterization, 50% displayed bacteriuria 48hours post catheterization & 62.5% displayed bacteriuria 71hours post catheterization. 11.1% of femail patients displayed infection 24hours post catheterization 66.7% displayed infection 48hours post catheterization and 72.7% displayed infection 72hours post catheterization. There were significant differences at 1% level between bacteriuria occurence of mail & femail patients and the duration of insertion. 2) 56% of those patient who have altered mental state developed bacteriuria, while 40% of those patient who have alear mental state developed bacteriuria. But there was without statistically any significant difference between patient's mental status. 3) The occurence of bacteriuria with the administration of antibiotics in 36 patient was in 50%. The occurence of bacteriuria without the administration of antibiotics in 4 patients was in 50%. But there was without statistically any significant difference between the administration of antibiotics. 4) The occurence of bacteriuria in patients according to frequency of bladder irrigation. 50% of those patient who irrigated twice a day developed bacteriuria, 63.6% of those patient who irrigated once a day developed bacteriuria. The occurence of bacteriuria in patients were significant differences at 1% level between frequency of bladder irrigation. 5) The occurence of bacteriuria in patients who did perineal care once a day was 58.1%, 22.6% of those patient who did perineal care twice a day developed bacteriuria. But there was without statistically any signiticant differences between frequency of perineal care. 6) Most frequent bacteria of all bacterial strains isolated by culture of the urine was E. coli(45%). Enterococci & Staphylococcus were 15% respectively.

  • PDF

MicroRNA-23a: A Novel Serum Based Diagnostic Biomarker for Lung Adenocarcinoma

  • Lee, Yu-Mi;Cho, Hyun-Jung;Lee, Soo-Young;Yun, Seong-Cheol;Kim, Ji-Hye;Lee, Shin-Yup;Kwon, Sun-Jung;Choi, Eu-Gene;Na, Moon-Jun;Kang, Jae-Ku;Son, Ji-Woong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.1
    • /
    • pp.8-14
    • /
    • 2011
  • Background: MicroRNAs (miRNAs) have demonstrated their potential as biomarkers for lung cancer diagnosis. In recent years, miRNAs have been found in body fluids such as serum, plasma, urine and saliva. Circulating miRNAs are highly stable and resistant to RNase activity along with, extreme pH and temperatures in serum and plasma. In this study, we investigated serum miRNA profiles that can be used as a diagnostic biomarker of non-small cell lung cancer (NSCLC). Methods: We compared the expression profile of miRNAs in the plasma of patients diagnosed with lung cancer using an miRNA microarray. The data from this assay were validated by quantitative real-time PCR (qRT-PCR). Results: Six miRNAs were overexpressed and three miRNAs were underexpressed in both tissue and serum from squamous cell carcinoma (SCC) patients. Sixteen miRNAs were overexpressed and twenty two miRNAs were underexpressed in both tissue and serum from adenocarcinoma (AC) patients. Of the four miRNAs chosen for qRT-PCR analysis, the expression of miR-23a was consistent with microarray results from AC patients. Receiver operating characteristic (ROC) curve analyses were done and revealed that the level of serum miR-23a was a potential marker for discriminating AC patients from chronic obstructive pulmonary disease (COPD) patients. Conclusion: Although a small number of patients were examined, the results from our study suggest that serum miR-23a can be used in the diagnosis of AC.