• Title/Summary/Keyword: Urbanization effect

Search Result 255, Processing Time 0.021 seconds

Modification of CFD results for Wind Environment in Urban area with Tree Canopy Model (Canopy Model 적용을 통한 도심지 풍환경 예측 CFD 시뮬레이션 결과의 보정)

  • Jung, Su-Hyeon;Hong, In-Pyo;Choi, Jong-Kyu;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.185-193
    • /
    • 2012
  • Recently rapid urbanization facilitates development of high-rise building complex including apartment and office building in urban area. Many problems related with high -rise building are reported. Especially, unpleasant strong winds in pedestrian area are frequently encountered around the high-rise building. CFD simulation methods are used to analyze the wind environment of pedestrian level in high-rise building block. However, the results show differences between CFD and measurement. This difference is attributed to improper use of CFD. Conventional CFD simulation for wind environment around high-rise building does not describe the effect of trees, shrubs and plants near ground which affect the wind environment of pedestrian level. Canopy model can be used to reproduce the aerodynamic effects of trees, shrubs and plants near ground. In this paper, CFD simulation methods coupled with the tree canopy model to predict wind environment of pedestrian level in high-rise residential building block were suggested and the validity was analyzed by comparison between measurement and CFD results.

A Study on the Mitigation Policies for Urban Heat Island (도시열섬 완화를 위한 제도개선)

  • Suh, Eung Chul
    • KIEAE Journal
    • /
    • v.7 no.2
    • /
    • pp.17-23
    • /
    • 2007
  • While heat island has been recognized as an unique environmental nuisance in cities, the phenomenon tends to be regarded as an inevitable side effect on urbanization. Recently the nature of the heat island has been disclosed and efforts for the remedy have been discussed in many ways. Some pioneering actions have been taken to mitigate the strength of the heat island's intensity in several countries. After studies for the heat island and speculations on current pilot policies of 3 different countries has been done, mitigation policies for heat island has been suggested as followings. 1. Preservation of natural topography is essential because latent energy consumption(evapotranspiration) from the site is the single most important factor to mitigate the energy surplus caused by urban heat island. 2. Because current national zoning ordinance or building law can not effectively control the site specific local environment, heat island policy should be established or employed at local level. 3. Incentives for the mitigation should be adopted on the process of implementation because environment is public concern. 4. Wind can easily dissipate energy surplus which is the major driving force for heat island. Therefore local wind, the direction and intensity should be sustained and sometimes facilitated fully through policies.

The Nexus between Urbanization, Gross Capital Formation and Economic Growth: A Study of Saudi Arabia

  • KHAN, Uzma
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.12
    • /
    • pp.677-682
    • /
    • 2020
  • To investigate the nexus between urban population, gross capital formation, and economic growth in the Kingdom of Saudi Arabia, yearly data was collected from the World Bank for the period 1974- 2018. Basic statistics test and correlation matrix was used to investigate the causal effect among the tested parameters, followed by Augmented Dickey-Fuller (ADF) stationary test, co-integration analysis by Johansen test after that Vector Auto-Correction Model for both short-run and long-run and finally the Granger-Causality tests. Result of unit root test analysis shows that the urban population became stationary at I (0) level while economic growth and gross capital formation became stationary at I (1). Johansen co-integration analysis indicates that there is presence of both long-run and short-run relationship between the three variables in the Kingdom of Saudi Arabia. The result of the VECM Model reflects that both economic growth and gross capital formation have a negative impact on urban population in the short run. According to the Granger-Causality tests, there is unidirectional causality with the urban population by both gross capital formation and economic growth. Also, the result of the Granger Causality tests show that there is unidirectional causality between economic growth and gross capital formations.

Analysis of Climate Variability under Various Scenarios for Future Urban Growth in Seoul Metropolitan Area (SMA), Korea (미래 도시성장 시나리오에 따른 수도권 기후변화 예측 변동성 분석)

  • Kim, Hyun-Su;Jeong, Ju-Hee;Kim, Yoo-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.3
    • /
    • pp.261-272
    • /
    • 2012
  • In this study, climate variability was predicted by the Weather Research and Forecasting (WRF) model under two different scenarios (current trends scenario; SC1 and managed scenario; SC2) for future urban growth over the Seoul metropolitan area (SMA). We used the urban growth model, SLEUTH (Slope, Land-use, Excluded, Urban, Transportation, Hill-Shade) to predict the future urban growth in SMA. As a result, the difference of urban ratio between two scenarios was the maximum up to 2.2% during 50 years (2000~2050). Also, the results of SLEUTH like this were adjusted in the Weather Research and Forecasting (WRF) model to analysis the difference of the future climate for the future urbanization effect. By scenarios of urban growth, we knew that the significant differences of surface temperature with a maximum of about 4 K and PBL height with a maximum of about 200 m appeared locally in newly urbanized area. However, wind speeds are not sensitive for the future urban growth in SMA. These results show that we need to consider the future land-use changes or future urban extension in the study for the prediction of future climate changes.

Effect of Rainfall Design Frequency Determination on the Design of Storm Sewer System (강우 확률년수의 설정이 우수관거 설계에 미치는 영향)

  • Lee, Cheol-kyu;Hyun, In-hwan;Dockko, Seok;Kim, Hyung-jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.647-654
    • /
    • 2005
  • Recently, the economic losses caused by inundation are increasing due to the urbanization and industrialization, i.e., intensive land utilization and concentration of population and properties. It is regarded that the role of the storm sewer systems in urban areas becomes more important as one of the effective countermeasures for reducing the inundation losses. In this study, the effects of rainfall design frequency enhancement on the construction cost of the storm sewer systems were analyzed by increasing the design frequency from the present design frequency of the sewer systems, which is 5~10 years, to 15 years, 20 years and 30 years. The change rate functions of the design discharge and construction cost based on the various design frequencies were derived by regression analysis. According to the analysis, change the rate of design discharge at 15, 20, 30 years rainfall design frequencies were increased by 10%, 17.1%, and 27.2%, respectively, when compared to that at 10 year frequency. Furthermore, it was found that by increasing the design frequency from 10 years to 15 years, 20 years and 30 years, the construction costs were increased by 5.0%, 8.0% and 12.4%, respectively. Finally, their reliabilities need to be tested by applying the rate functions to the real storm sewer districts.

Development of Water Supply System under Uncertainty

  • Chung, Gun-Hui;Kim, Tae-Woong;Kim, Joong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.2179-2183
    • /
    • 2009
  • As urbanization is progressed, the network for distributing water in a basin become complex due to the spatial expansion and parameter uncertainties of water supply systems. When a long range water supply plan is determined, the total construction and operation cost has to be evaluated with the system components and parameter uncertainties as many as possible. In this paper, the robust optimization approach of Bertsimas and Sim is applied in a hypothetical system to find a solution which remains feasible under the possible parameter uncertainties having the correlation effect between the uncertain coefficients. The system components to supply, treatment, and transport water are included in the developed water supply system and construction and expansion of the system is allowed for a long-range period. In this approach, the tradeoff between system robustness and total cost of the system is evaluated in terms of the degree of conservatism which can be converted to the probability of constraint violation. As a result, the degree of conservatism increases, the total cost is increased due to the installation of large capacity of treatment and transportation systems. The applied robust optimization technique can be used to determine a long-range water supply plan with the consideration of system failure.

  • PDF

Climate change effect on storm drainage networks by storm water management model

  • Hassan, Waqed Hammed;Nile, Basim Khalil;Al-Masody, Batul Abdullah
    • Environmental Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.393-400
    • /
    • 2017
  • One of the big problems facing municipalities is the management and control of urban flooding where urban drainage systems are under growing pressure due to increases in urbanization, population and changes in the climate. Urban flooding causes environmental and infrastructure damage, especially to roads, this damage increasing maintenance costs. The aim of the present study is to develop a decision support tool to identify the performance of storm networks to address future risks associated with climate change in the Middle East region and specifically, illegal sewer connections in the storm networks of Karbala city, Iraq. The storm water management model has been used to simulate Karbala's storm drainage network using continuous hourly rainfall intensity data from 2008 to 2016. The results indicate that the system is sufficient as designed before consideration of extra sewage due to an illegal sewer connection. Due to climate changes in recent years, rainfall intensity has increased reaching 33.54 mm/h, this change led to flooding in 47% of manholes. Illegal sewage will increase flooding in the storm system at this rainfall intensity from between 39% to 52%.

Long-term Behavior of FCM Bridges considering Seasonal Temperature Variation - Part 1 (계절변화에 따른 PSC 균형 켄틸레버 교량의 장기거동 특성)

  • Lee, Son-Ho;Lee, Hak-Eun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.1 no.2 s.2
    • /
    • pp.93-101
    • /
    • 2001
  • The objective of this study is to derive a shrinkage correction formula that considers temperature effect and to develop a methodology for the improved prediction of the long-term behavior of the FCM bridges by considering seasonal temperature variations in-situ. Thereby, current formulation were performed by using the actual experimental shrinkage data including seasonal temperature variation. The investigation of the long-term behavior of the FCM bridge was performed on the construction site in order to decide applicability of the shrinkage formula Numerical results by the general method indicates inaccurate values of total strain when considering real strain, whereas the applied method demonstrates a good agreement in the resultant strain. In consequently, the applied method will improve the prediction of the long-term deformation of the FCM Bridges.

  • PDF

A Study on Effect of Geogrid Reinforced- Crushed stone Sub-base in Permeable Pavement System (투수성 포장체 쇄석 보조기층 지오그리드 보강효과 확인에 대한 연구)

  • Kwon, Hyeok-Min;Oh, Jeongho;Han, Shin-in
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.64-70
    • /
    • 2015
  • A rapid urbanization has increased the portion of paved layer that results in the change of water circulation system. This change leads to frequent events of flooding, drought, and urban heat island. To resolve these issues, permeable pavement system based on Low Impact Development (LID) concept is being applied to international urban areas. Therefore it is necessary to establish a rational design procedure for the permeable pavement system that reflects our environmental conditions. iDue to inherent characteristics of permeable pavement system, water infiltrates thorough the layers so it may reduce the bearing capacity of sub-layers. In this study, an effort was made to investigate the effectiveness of geogrid reinforced crushed stone subbase layer based on field experimental program along with a limited numerical analysis. It reveals that geogrid reinforced sections improve the bearing capacity by close to 20%. In addition, a light weight deflectomenter (LWDT) appears to be promising for the compaction quality control of crushed stone subbase layer in order to construct qualified permeable pavement systems.

A Study on the Actual Conditions of Indoor Air Quality of Underground Dwellings and the Automatic Ventilating Fan Operated by CO2 Controller and Timer (지하주거의 실내공기환경 실태조사와 CO2 조절기 및 타이머에 의한 환기팬 자동운전에 관한 연구)

  • Kwon, Young Cheol;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.3-9
    • /
    • 2008
  • The rapid urbanization after 1970s caused the shortage of dwellings in urban areas. As the result, the underground dwellings were developed to compensate for the insufficient dwelling spaces. While the underground dwellings have some advantage in the respect of thermal and acoustic environment, they usually have the basic problems in the indoor air quality because of the lack of natural ventilation through small window areas. The purpose of this study is to investigate and to improve the indoor air quality of underground dwellings. Thirty Units in Seoul and Gyung-Gi Province were investigated into the indoor environmental conditions. For the purpose of the improvement of their indoor air quality, Automatically-operated ventilating fan was installed in a sample unit which has worst indoor environmental condition. Then the indoor air quality was monitored when it was operated by $CO_2$ control system and timer. Finally economic feasibility study was made considering the effect of the improvement of indoor air quality. The extra cost for installing timer could be paid back only in 10 months, so timer-installed automatic fan is recommended to improve the indoor air quality of underground dwellings.