• Title/Summary/Keyword: Urban underground subway

Search Result 82, Processing Time 0.028 seconds

Analysis of Institutional Limitations on Evacuation of Urban Railway Station Facilities and Guidelines (도시철도역 시설의 피난에 대한 제도적 한계점 분석과 가이드라인)

  • Yekyeong Shin;Okkyung Yuh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.15 no.4
    • /
    • pp.1-9
    • /
    • 2022
  • This study analyzes the institutional status related to 'evacuation' and 'firefighting' in underground subway stations, derives institutional limitations for 'evacuation' in underground subway stations, and proposes guidelines in terms of architectural space based on this. As a result of the study, the following points were derived. First, since similar standards are separately enacted in individual laws and it is difficult to grasp the standards and they are dualized, it is necessary to standardize and regulate the space where users stay according to the movement of urban railway users, limited to urban railways. Second, in order to use trains, a special procedure called 'ticketing' must be considered, and regulations on evacuation safety zones and evacuation stairs between the waiting room and the platform are required. Finally, if there is a platform at a depth of more than 30m underground, it is necessary to install an evacuation floor in accordance with standards similar to the current building law.

A Study on 3D Tunnel Data Model for Integrated Map of Underground Spaces (지하공간통합지도의 3차원 터널 데이터 모델에 관한 연구)

  • Lee, Ji Yeon;Ryu, Ji Hui;Jeong, Da Woon;Ahn, Jong Wook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.371-380
    • /
    • 2021
  • This study aims to design a tunnel part model for underpass and subway lines that correspond to tunnel sector among the underground facilities(structure types) covered in the integrated map of underground spaces. For this purpose, we compared and reviewed the characteristics of international standards related to tunnel data models. As a result, it was found that CityGML 3.0 - Tunnel module was the most suitable for designing a 3D tunnel data model. Afterwards we reviewed the legal and institutional regulations to derive the standard elements of the 3D tunnel data model. Then we conducted a demand survey targeting experts in related fields to derive standard elements for addition and extension of underpasses and subway lines. Based on the above process, we designed and presented a 3D tunnel data model using UML. This study is expected to be meaningful as a basic study to improve the utilization of tunnel model in the integrated map of underground spaces.

도심지역 지하수관리를 위한 지하수환경 모니터링

  • 이진용;최미정;이명재;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.277-279
    • /
    • 2002
  • In late of the 1980's, dramatic increase in water use caused over-exploitation of groundwater and deterioration of water quality in urban areas. To monitor quantity of groundwater resources and their qualities, local groundwater monitoring networks were established. Groundwater resources in urban areas are affected by various human activities including underground building construction (subway), pumping for water use, and pavements. Detailed analysis of the monitored groundwater data would provide some good implications for optimal and efficient management for groundwater resources in the urban area.

  • PDF

Removal Efficiency of PM10 & $CO_2$ in Subway Mock-up Cabin (지하철 목업차량내 객실 공기정화장치의 미세먼지(PM10) 및 $CO_2$ 저감성능평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;Nam, Goong-Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.613-618
    • /
    • 2011
  • More than 7 million persons use Seoul Metropolitan Subways (SMS) everyday and the number has been in increasing trend. With the increasing trend of concerns on indoor air quality(IAQ), the management of IAQ has become an important issue, especially in case of subway operators, because most of subway lines are placed underground with poor ventilation condition. The ultimate object of study develop independent cleaning device that reduce efficient fine particle and $CO_2$. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. Two layered electrically pre-charged filters were used for removing particulate matters and gas absorbers are packed between two layer filters for removing gases pollutants such $CO_2$, VOCs and HCHO. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. SCAP prototype is producted as all in one method which decrease fine dust, $CO_2$ and noxious gas. and basic test carry out with quantity of wind, a gap of pressure, sampling efficiency.

  • PDF

A Study on the Management of Subway Structure as an Underground Facility (지하 시설물로서의 지하철 구조물 관리 방안에 관한 연구)

  • 김충평;김감래
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.1
    • /
    • pp.21-28
    • /
    • 1997
  • Since beginning of subway construction in 1974, for supplying the demand for increasing urban traffic and solving the traffic jam due to expansion of society and elevation of an individual income, the $1^{st}\;and\;2^{nd}$ construction have been almost done and $3^{rd}$ has been driving forward. However, according to an increment of com-mon usage with the passage of time, structures are superannuated and the amount of improvement and repairs keeps on increasing continuous. And many problems are taking place at underground space because of new constructions for underground facilities such as urban gas, electric power, waterworks, and sewerage. In consequence. The consideration of a counterplan for safety is required deeply This study analyzed problems on maintenance of structure about $1^{st}$ class subway, and will present means that a manage civil structures scientifically and systematically by using GSIS concept that imported into several organizations for facility management recently as making digital graphic elements and historic data into a database rather than using an old method - documents and paper drawings.

  • PDF

Relationship between Flood Characteristics and Underground Inundation (홍수특성과 지하공간침수의 관계 검토)

  • Lee, Dae-Young;Lee, Keon-Haeng;Kyoung, Min-Soo;Kim, Hung-Soo
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.367-370
    • /
    • 2007
  • In recent, the utilization of underground in urban area is increased as subway, store, and others but we have done a few studies for the inundation of underground due to flooding. So, we investigate the examples of underground inundation and the causes of inundation for flood events. And the relationship between flood characteristics and underground inundation is analyzed through the frequency of rainfall which is made by annual multi maximum series. As a result, most of underground is inundated by high frequency of rainfall. And there are some cases that the underground is inundated by low frequency of rainfall because of poor drainage system and characteristics of location.

  • PDF

Investigation for Fire Flow of the Deeply Underground Shin-Gum-Ho Subway Station (대심도 신금호역사의 화재 유동에 대한 고찰)

  • Jang, Yong-Jun;Park, Il-Soon;Kim, Jin-Ho;Jung, Woo-Sung;Kim, Hag-Beom;Lee, Chang-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.110-115
    • /
    • 2010
  • Recently the deeply underground tunnels have been increased along the subway railroads of urban area compared to the past subway railroads. The Shin-Gum-Ho subway station (the Fifth lines, the depth : 46m) which is the third among the deep subway stations in the Korea was chosen as the model of deeply underground stations, and attempted to do simulation of fire. This station consists of three entrance, the basement first floor (B1), the basement second floor (B2), the basement eighth floor or platform (B8) and escalators and stairs from B2 to B8. The total number of grid was about 9,000,000 to make simulation of fire and smoke from the platform to entrance in this research, and the grid system was divided into 19 blocks to increase the efficiency of this simulation. The FDS (Fire Dynamics Simulation) was chosen to make the simulation of fire, and the model of turbulent flow was LES (Large Eddy Simulation). Each block is processed in a CPU using parallel processing of MPI (Message Passing Interface). The resource of CPU for this simulation is a ten of Intel 3.0 GHz Dual CPU (20 CPU).

  • PDF

A Study of Connecting Space Designs in the Development of the Underground Space -focused on University and Subway Area- (지하공간개발에서의 연계공간 디자인연구 -대학가와 지하철역을 중심으로-)

  • 박전자
    • Korean Institute of Interior Design Journal
    • /
    • no.15
    • /
    • pp.17-30
    • /
    • 1998
  • Through the rapid growth of Korea for the effectiveness and rationalization of the use of land the development of the underground land is mostly needed. Especially I think that in the limited country(like Korea) when we consider that the population of metropolitan area is almost a third if a total population of this country it is time that we should consider the method of transfer for using of under ground not of on the ground from the legal or systematic recognition of the land. In this respect it is necessary that the person involved in the urban development (the person for architect urban development landscape architect and adminstratives) should pay much attention to the using of the underground spaces.

  • PDF

Underground Space Development and Strategy in Korea (국내 지하공간 개발 및 대책)

  • Shin, Hee-Soon
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.327-336
    • /
    • 2013
  • Approximately 70% of the Korean peninsula is composed of mountains, around 99,274 $km^2$. Even worse, population rate of Korea is the No.3 in the world now. Accordingly, it is necessary to develop the potential underground space actively with the concept of another territory to be utilized. The development of underground space should be considered not a choice but an indispensable issue. Since 1970s, many large-scale underground structures have been constructed like as crude-oil storage bins, liquefied petroleum gas storage caverns, and underground pumped storage powerplants. Also, In urban area, the underground facilities such as subway networks, underground shopping mall, underground pedestrian network, electric power tunnels, and car parking lots have been used extensively. The scale of Yeosu oil and gas underground storage facility and Seoul subway systems are one of the massive scale in the world. Recently, the trend of the development of underground space becomes more diverse and larger scale. The current status of Korean underground space developments and strategy are described in this paper.

Research on Efficient Applicability Through Review on Standard for Selection of Construction Method for Railway Underground Crossing Transit (철도지하횡단 통과 공법 선정기준에 관한 검토를 통해 효율적인 적용성에 대한 연구)

  • Hwang, Young-Ho;Shon, Jung-Chul;Baek, Jong-Myeong
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.595-600
    • /
    • 2007
  • Greater expansion and more frequent operation of the railroad transportation system anticipated due to its characteristics including low cost, safety and mass transportation. Recently, effects on the railway structures due to expansion of newly constructed road, construction of subway, city gas pipeline, communication network, electric power network and construction of other railway underground crossing in accordance with urban planning and organization has influenced safe operation of trains. Accordingly, standard for selection of construction method that will enable construction of more economical and rational subway underground crossing structures by preventing problems occurring at the time of above construction works and accidents in safe operation of trains due to construction in advance is definitively necessary. Although there are numerous construction methods that can be applied at the time of construction of railway underground crossing, there are much difficulties in selection of appropriate construction method that considers characteristics of each construction method on non-excavation type construction method, train operation plan of number of operational routes and on-site circumstances. Therefore, this research aims to present rational standard for selection of construction method for such, and standard for slowdown speed and interception of train when passing the areas of slowdown in sectors under construction.

  • PDF