• 제목/요약/키워드: Urban air temperature

검색결과 350건 처리시간 0.031초

The Mobile Composting Device Development of Organic Wastes (유기성 폐기물의 이동용 퇴비화 장치개발에 관한 연구)

  • Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • 제21권2호
    • /
    • pp.56-62
    • /
    • 2013
  • Organic wastes are not disposing object but renewable resources. One of those ways of rendering to resources, composting is environmentally friendly way as to aspect of recycling of resources. Regardless of ways, composting goes through the main processes which are fermentation process and curing process. In the study, mobile composting device was developed with the experiments which were performed to solve the problems of fermentation and curing process. Since reaction vessel is rotated, it does not cease in the middle of agitation because of foreign. In addition, it mixed as well. With maintaining uniform temperature of reaction vessel by controlling amount of air, fermentation and curing are easy to use. Its economic feasibility is better than the existing fermentation equipments. Furthermore, it benefits to reduce the personnel and materiel maintenance cost, and mass produce composting product which use organic waste. Especially, although it needs less space, it has effect to provide transferable composting device with available area to increase by contacting organic waste to air.

Hydrological Drought Assessment and Monitoring Based on Remote Sensing for Ungauged Areas (미계측 유역의 수문학적 가뭄 평가 및 감시를 위한 원격탐사의 활용)

  • Rhee, Jinyoung;Im, Jungho;Kim, Jongpil
    • Korean Journal of Remote Sensing
    • /
    • 제30권4호
    • /
    • pp.525-536
    • /
    • 2014
  • In this study, a method to assess and monitor hydrological drought using remote sensing was investigated for use in regions with limited observation data, and was applied to the Upper Namhangang basin in South Korea, which was seriously affected by the 2008-2009 drought. Drought information may be obtained more easily from meteorological data based on water balance than hydrological data that are hard to estimate. Air temperature data at 2 m above ground level (AGL) were estimated using remotely sensed data, evapotranspiration was estimated from the air temperature, and the correlations between precipitation minus evapotranspiration (P-PET) and streamflow percentiles were examined. Land Surface Temperature data with $1{\times}1km$ spatial resolution as well as Atmospheric Profile data with $5{\times}5km$ spatial resolution from MODIS sensor on board Aqua satellite were used to estimate monthly maximum and minimum air temperature in South Korea. Evapotranspiration was estimated from the maximum and minimum air temperature using the Hargreaves method and the estimates were compared to existing data of the University of Montana based on Penman-Monteith method showing smaller coefficient of determination values but smaller error values. Precipitation was obtained from TRMM monthly rainfall data, and the correlations of 1-, 3-, 6-, and 12-month P-PET percentiles with streamflow percentiles were analyzed for the Upper Namhan-gang basin in South Korea. The 1-month P-PET percentile during JJA (r = 0.89, tau = 0.71) and SON (r = 0.63, tau = 0.47) in the Upper Namhan-gang basin are highly correlated with the streamflow percentile with 95% confidence level. Since the effect of precipitation in the basin is especially high, the correlation between evapotranspiration percentile and streamflow percentile is positive. These results indicate that remote sensing-based P-PET estimates can be used for the assessment and monitoring of hydrological drought. The high spatial resolution estimates can be used in the decision-making process to minimize the adverse impacts of hydrological drought and to establish differentiated measures coping with drought.

Evaluation of Climate Change between Agricultural Area and Urban Area in Jeonbuk Province, ROK (전북의 농경 지역과 도시 지역에서 기후변화 비교 평가)

  • Lee, Deog Bae;Shim, Kyo Moon;Kwon, Soon Ik
    • Journal of Climate Change Research
    • /
    • 제2권1호
    • /
    • pp.33-42
    • /
    • 2011
  • It was analyzed climatic data in Gimje, Buan, Iksan and Jeonju in Jeonbuk Province between 1930s and 1990s. The data source of Gimje and Iksan in 1930s were Namseon Agricultural Experimental Station. Those in 1990s was Honam Agricultural Research Institute, Rural Development Administration. The data source of Jeonju of 1930s and 1990s was Jeonju Weather Station, Korea Meteorological Administration. Weather Station of Gimje and Buan were located at the agricultural area in rural paddy field. That of Iksan was located at the agricultural area in suburban paddy field. That of Jeonju was located at the downtown area. As compared to mean air temperature between 1930s and 1990s, it was increased by $0.2^{\circ}C$ in agricultural area, $0.6^{\circ}C$ in Iksan city and $1.4^{\circ}C$ in Jeonju city. On the while, increased temperature was the higher in winter than other seasons. Annual precipitation was increased by 128.1 mm in agricultural area and 169.3 mm in Jeonju city. And it was remarkable in summer season.

A Study on Reduction Effect of White Smoke Fog in Urban Detention Basin using a Fog Removal System (안개제거장치를 이용한 도심 저류지 시설에서의 안개 저감 효과 연구)

  • Lee, Kyu Hong;Lee, Sang Woo;Choi, Jun Sung;Lee, Sung Kyun;Park, Jihwan;Park, Seunghee
    • Journal of Korean Society of Disaster and Security
    • /
    • 제11권2호
    • /
    • pp.69-74
    • /
    • 2018
  • Fog to which environmental impacts are sensitive has a danger to the safety of citizens due to the difficulty in predicting the specific area/time zone. Therefore, we propose a white smoke fog reduction technique using a fog removal device that can remove fog particles directly through dry air and anionic condensation nucleus instead of conventional passive countermeasures. In this study, to verify the effect of reducing fog and the effect of temperature on the white smoke fog which is frequently occurred in the detention basin. As a result, the visible distance of 100m or more was secured within 30 seconds, and it was confirmed that the fog reduction effect is more effective. Also, the lower the temperature, the larger the amount of white smoke fog was. However, the effect of reducing the white smoke fog by temperature was insignificant. Through this experiment, it was possible to verify the reduction effect of the white smoke fog generated in the detention basin through fog removal device.

Mapping Monthly Temperature Normals Across North Korea at a Landscape Scale (북한지역 평년의 경관규모 기온분포도 제작)

  • Kim, Soo-Ock;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • 제13권1호
    • /
    • pp.28-34
    • /
    • 2011
  • This study was carried out to estimate monthly mean of daily maximum and minimum temperature across North Korea at a 30 m grid spacing for a climatological normal year (1971-2000) and the 4 decadal averages (1971-1980, 1981-1990, 1991-2000, and 2001-2010). A geospatial climate interpolation method, which has been successfully used to produce the so-called 'High-Definition Digital Climate Maps' (HD-DCM), was used in conjunction with the 27 North Korean and 17 South Korean synoptic data. Correction modules including local effects of cold air drainage, thermal belt, ocean, solar irradiance and urban heat island were applied to adjust the synoptic temperature data in addition to the lapse rate correction. According to the final temperature estimates for a normal year, North Korean winter is expected colder than South Korean winter by $7^{\circ}C$ in average, while the spatial mean summer temperature is lower by $3^{\circ}C$ than that for South Korea. Warming trend in North Korea for the recent 40 years (1971-2010) was most remarkable in spring and fall, showing a 7.4% increase in the land area with 15 or higher daily maximum temperature for April.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Human Thermal Environment Analysis with Local Climate Zones and Surface Types in the Summer Nighttime - Homesil Residential Development District, Suwon-si, Gyeonggi-do (Local Climate Zone과 토지피복에 따른 여름철 야간의 인간 열환경 분석 - 경기도 수원시 호매실 택지개발지구)

  • Kong, Hak-Yang;Choi, Nakhoon;Park, Sookuk
    • Ecology and Resilient Infrastructure
    • /
    • 제7권4호
    • /
    • pp.227-237
    • /
    • 2020
  • Microclimatic data were measured, and the human thermal sensation was analyzed at 10 local climate zones based on the major land cover classification to investigate the thermal environment of urban areas during summer nighttime. From the results, the green infrastructure areas (GNIAs) showed an average air temperature of 1.6℃ and up to 2.4℃ lower air temperature than the gray infrastructure areas (GYIAs), and the GNIAs showed an average relative humidity of 9.0% and up to 15.0% higher relative humidity. The wind speed of the GNIAs and GYIAs had minimal difference and showed no significance at all locations, except for the forest location, which had the lowest wind speed owing to the influence of trees. The local winds and the surface roughness, which was determined based on the heights of buildings and trees, appeared to be the main factors that influenced wind speed. At the mean radiant temperature, the forest location showed the maximum value, owing to the influence of trees. Except at the forest location, the GNIAs showed an average decrease of 5.5℃ compared to GYIAs. The main factor that influenced the mean radiant temperature was the sky view factor. In the analysis of the human thermal sensation, the GNIAs showed a "neutral" thermal perception level that was neither hot nor cold, and the GYIAs showed a "slightly warm" level, which was a level higher than those of the GNIAs. The GNIAs showed a 3.2℃ decrease compared to the GYIAs, except at the highest forest location, which indicated a half-level improvement in the human thermal environment.

Analysis of Meteorological Factors when Fine Particulate Matters Deteriorate in Urban Areas of Jeju Special Self-Governing Province (제주특별자치도 도시지역 미세먼지 악화 시 기상요소 분석)

  • Sin, Jihwan;Jo, Sangman;Park, Sookuk
    • Ecology and Resilient Infrastructure
    • /
    • 제9권1호
    • /
    • pp.36-58
    • /
    • 2022
  • In this study, the weather conditions corresponding to the increase in the environmental concentration of fine dust (PM10) and ultrafine dust (PM2.5) from 2001 to 2019 in Jeju and Seogwipo cities were analyzed. The increase in the levels of PM10 and PM2.5 was observed in the order: spring > winter > autumn > summer. In both cities, PM10 and PM2.5 levels increased more frequently during the day in spring and summer and at night in autumn and winter, with PM2.5 showing a greater increase in concentration than PM10. The air temperature and wind speed corresponding with increased levels of PM10 were higher than their respective seasonal averages in spring and winter, but lower in summer and autumn. Relative humidity was lower than the seasonal average during all seasons. The air temperature variation corresponding with increased levels of PM2.5 showed the same seasonal trend as that observed for PM10. The relative humidity was higher than the respective seasonal averages in spring and summer, and lower in winter. The wind speed was lower than the seasonal average in both the cities. When the PM10 and PM2.5 levels increased, the wind direction was from the north and the west during the day and varied according to the season at night. The rate of the increase in the PM10 concentration was the highest in both cities at the wind speed of 1.6 - 3.4 ms-1 during the day and night except during night in the summer. The highest concentration of PM2.5 was observed with the wind speed range of 1.6 - 3.4 ms-1 in Jeju, and 0.3 - 1.6 ms-1 in Seogwipo. The results of this study applied to urban and landscape planning will aid in the formulation of strategies to reduce the adverse effects of fine particular matter.

Spaciotemporal Distributions of PM10 Concentration and Their Correlation with Local Temperature Changes : a Case Study of Busan Metropolitan City (PM10 농도의 시공간적 분포 특징과 국지적 기온 변화 간의 상관관계: 부산광역시 사례 분석)

  • Park, Sunyurp
    • Journal of the Korean association of regional geographers
    • /
    • 제23권1호
    • /
    • pp.151-167
    • /
    • 2017
  • The main objective of this study was to investigate the climatic impact of $PM_{10}$ concentration on the temperature change pattern in Busan Metropolitan City(BMC), Korea during 2001~2015. Mean $PM_{10}$ concentration of BMC has gradually declined over the past 15 years. While the highest $PM_{10}$ concentration was observed in spring followed by winter, summer, and fall on average, the seasonal variations of $PM_{10}$ concentration differed from place to place within the city. Frequency analysis showed that the most frequently observed $PM_{10}$ concentration ranged from $20{\mu}g/m^3$ to $60{\mu}g/m^3$, which accounted for 64.6% of all daily observations. Overall, the west-high and east-low pattern of $PM_{10}$ concentration was relatively strong during the winter when the effect of yellow-dust events on the air quality was weak. Comparative analyses between $PM_{10}$ concentration and monthly temperature slope derived from generalized temperature curves indicated that the decreasing trend of $PM_{10}$ concentration was associated with increases of annual temperature range, and $PM_{10}$ concentration had a negative relationship with the temperature slope of warming months. Overall, $PM_{10}$ concentration had a weak correlation with the annual mean temperature, but it had a significant, positive correlation with the winter season, which had a dominant influence on the annual mean temperature. In terms of energy budget, it has been known that the change in $PM_{10}$ concentration contributes to the warming or cooling effect by affecting the radiative forcing due to the reflection and absorption of radiant energy. The correlation between $PM_{10}$ concentration and temperature changes in the study area was not seasonally and spatially consistent, and its significance was statistically limited partly due to the number of observations and the lack of potential socioeconomic factors relevant to urban air quality.

  • PDF

The Characteristics of Retention and Evapotranspiration in the Extensive Greening Module of Sloped and Flat Rooftops (저토심 경사지붕과 평지붕 녹화모듈의 저류 및 증발산 특성)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • 제41권6호
    • /
    • pp.107-116
    • /
    • 2013
  • This study was undertaken to investigate the characteristics of retention and evapotranspiration in the extensive greening module of sloped and flat rooftops for stormwater management and urban heat island mitigation. A series of 100mm depth's weighing lysimeters planted with Sedum kamtschaticum. were constructed on a 50% slope facing four orientations(north, east, south and west) and a flat rooftop. Thereafter the retention and evapotranspiration from the greening module and the surface temperature of nongreening and greening rooftop were recorded beginning in September 2012 for a period of 1 year. The characteristics of retention and evapotranspiration in the greening module were as follows. The water storage of the sloped and flat greening modules increased to 8.7~28.4mm and 10.6~31.8mm after rainfall except in the winter season, in which it decreased to 3.3mm and 3.9mm in the longer dry period. The maximum stormwater retention of the sloped and flat greening modules was 22.2mm and 23.1mm except in the winter season. Fitted stormwater retention function was [Stormwater Retention Ratio(%)=-18.42 ln(Precipitation)+107.9, $R^2$=0.80] for sloped greening modules, and that was [Stormwater Retention Ratio(%)=-22.64 ln(X)+130.8, $R^2$=0.81] for flat greening modules. The daily evapotranspiration(mm/day) from the greening modules after rainfall decreased rapidly with a power function type in summer, and with a log function type in spring and autumn. The daily evapotranspiration(mm/day) from the greening modules after rainfall was greater in summer > spring > autumn > winter by season. This may be due to the differences in water storage, solar radiation and air temperature. The daily evapotranspiration from the greening modules decreased rapidly from 2~7mm/day to less than 1mm/day for 3~5 days after rainfall, and that decreased slowly after 3~5 days. This indicates that Sedum kamtschaticum used water rapidly when it was available and conserved water when it was not. The albedo of the concrete rooftop and greening rooftop was 0.151 and 0.137 in summer, and 0.165 and 0.165 in winter respectively. The albedo of the concrete rooftop and greening rooftop was similar. The effect of the daily mean and highest surface temperature decrease by greening during the summer season showed $1.6{\sim}13.8^{\circ}C$(mean $9.7^{\circ}C$) and $6.2{\sim}17.6^{\circ}C$(mean $11.2^{\circ}C$). The difference of the daily mean and highest surface temperature between the greening rooftop and concrete rooftop during the winter season were small, measuring $-2.4{\sim}1.3^{\circ}C$(mean $-0.4^{\circ}C$) and $-4.2{\sim}2.6^{\circ}C$(mean $0.0^{\circ}C$). The difference in the highest daily surface temperature between the greening rooftop and concrete rooftop during the summer season increased with an evapotranspiration rate increase by a linear function type. The fitted function of the highest daily surface temperature decrease was [Temperature Decrease($^{\circ}C$)=$1.4361{\times}$(Evapotranspiration rate(mm/day))+8.83, $R^2$=0.59]. The decrease of the surface temperature by greening in the longer dry period was due to sun protection by the sedum canopy. The results of this study indicate that the extensive rooftop greening will assist in managing stormwater runoff and urban heat island through retention and evapotranspiration. Sedum kamtschaticum would be the ideal plant for a non-irrigated extensive green roof. The shading effects of Sedum kamtschaticum would be important as well as the evapotranspiration effects of that for the long-term mitigation effects of an urban heat island.