• Title/Summary/Keyword: Urban Sewage

Search Result 197, Processing Time 0.03 seconds

Development and Lab-scale Plant Study of Coagulation Sedimentation Module using Cyclone (선회류를 이용한 응집침전모듈의 개발 및 실증 연구)

  • Moon, Jinyoung;Cho, Young-Gun;Song, Seung-Jun;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3336-3344
    • /
    • 2014
  • The purpose of this study is small scale coagulation module is developed and demonstrated through a lab-scale test. Recent as a sewage treatment rate increases, have heightened the interest in the necessity on the nonpoint source and developing a small processing unit has been increased. Coagulation sedimentation module in this study is additional growth of floc through swirling in the outside zone, reduction of microstructure floc number and the internal settling zone through vertical/level flow complex sedimentation method after the coagulation process precipitation method as an effective high separation efficiency can be divided was also assessed. Coagulation sedimentation module can increase the load factor was 4.4 times compared to conventional clarifier base on the same volume and surface area through vertical/level flow. In this study, this process was selected formation and maintenance of swirling and uniform flow distribution in the internal settling zone as an important design factor, to derive its FLUENT was used to characteristics of the flow model. Through the simulation of swirling, influent velocity, dimensions of external basin, hopper depth of bottom cone was determined and through analysis of velocity distribution, flow distribution detailed specifications are derived like as diameter and number of effluent hole. Lab-scale($120{\ell}/hr$) test results, influent of 300~800 NTU to less than 10 NTU without polymer feeding was able to operate in the 20minutes retention time(surface loading rate $37.3m^3/m^2$-day), and through analysis FLUENT the possibility of using design parameters were derived.

Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO (분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어)

  • Baek, Hyunwook;Ryu, Jaena;Kim, Tea-Hyoung;Oh, Jeill
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.722-728
    • /
    • 2012
  • Urban sewer systems has a limitation of capacity of rainwater storage and problem of occurrence of untreated sewage, so adopting a storage facility for sewer flooding prevention and urban non-point pollution reduction has a big attention. The Korea Ministry of Environment has recently introduced a new concept of "multi-functional storage facility", which is crucial not only in preventive stormwater management but also in dealing with combined sewer overflow and sanitary sewer discharge, and also has been promoting its adoption. However, reserving a space for a single large-scale storage facility might be difficult especially in urban areas. Thus, decentralized construction of small- and midium-sized storage facilities and its operation have been introduced as an alternative way. In this paper, we propose a model predictive control scheme for an optimized operation of distributed storage facilities and sewer networks. To this aim, we first describe the mathematical model of each component of networks system which enables us to analyze its detailed dynamic behavior. Second, overflow locations and volumes will be predicted based on the developed network model with data on the external inflow occurred at specific locations of the network. MPC scheme based on the introduced particle swarm optimization technique then produces the optimized the gate setting for sewer network flow control, which minimizes sewer flooding and maximizes the potential storage capacity. Finally, the operational efficacy of the proposed control scheme is demonstrated by simulation study with virtual rainstorm event.

Fundamental Properties of Low Strength Concrete Mixture with Blast Furnace Slag and Sewage Sludge (고로슬래그미분말 및 하수슬러지를 활용한 저강도 콘크리트의 기초적 물성)

  • Kwon, Chil Woo;Lim, Nam Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.136-144
    • /
    • 2013
  • In this study, in order to establish a plan that will enable safe use of renewable resources such as diverse industrial by-products and urban recycled materials, we conducted experiments that focused on flow, bleeding, compressive strength and environmental pollution evaluation to evaluate the material properties of low strength concrete using BFS and SS. In the case of low strength concrete using BFS and SS, blending of at least BFS 6000 within a 30% range regardless of the type of sand used was found to be the most effective approach for improving the workability by securing the minimum unit quantity of water, restraining the bleeding ratio and establishing compressive strength by taking account of the applicability at the work site. In particular, in view of the efficient use of SS, the optimal mixing condition was found to be the mixing of BFS 8000 with in the 30% range, not only for improving the workability restraining the bleeding ratio and establishing the compressive strength but also for application to the work site. Further, the results of tests on hazardous substance content and those of elution tests conducted on soil cement using SS indicated that all values satisfied the environmental standards without any harmful effects on the surrounding environment.

Indicators of Rural Regional Development Level by the City/County Type (농촌지역 발전수준 지표체계 설정과 시·군 유형별 비교)

  • Koo, Seung-Mo;Park, Yoon-Ho;Lee, Han-Sung;Choi, Se-Hyun
    • Journal of agriculture & life science
    • /
    • v.44 no.3
    • /
    • pp.99-110
    • /
    • 2010
  • This paper builds a system of indicators representing rural regional development level. Indicators were classified into two groups, that is, living environment indicator group and regional vitality indicator group. Living environment indicator group consists of four indicators including housing, road, water supply, and sewage system, while regional vitality indicator group consists of five indicators including regional economy, public finance, and demography. Real data of the year 2002 and 2006 were used to do the basic statistical analysis and estimate the suitable statistical distributions for each indicator. Data were applied for the three city/county type, general city, urban-rural combined city, and county. General cities have the strongest urbanization tendency among the three types, while counties have the weakest tendency. General cities turned out to be superior in housing condition, road density, water supply system and sewage system. Indicators of employment and local finance showed the highest levels in counties. The results of this analysis are expected to provide local governments with the appropriate reference for their rural regional development policy.

Studies on the Water Quality of Urban Streams in Daegu City (대구시(大邱市) 도시하천(都市河川)의 수질조사(水質調査) 연구(硏究))

  • Lee, Jyung Jae;Park, Byoung Yoon;Choi, Jyung
    • Current Research on Agriculture and Life Sciences
    • /
    • v.6
    • /
    • pp.99-104
    • /
    • 1988
  • Water polution status of urban streams in Daegu city were observed to provide the basic information for the effective purification of urban sewage and the conservation of Keumho river. Periodically, pH, DO, COD, nitrate and phosphate of water were investigated at Yee cheon, B$\ddot{o}$m$\ddot{o}$ cheon, Chilsung cheon, Dalseo cheon and Kongdan cheon. The results were as follows. 1) The ranges of average values of analyzed components for 12 months at six sampling sites were pH 7.3-8.2, DO trace-6.5ppm, COD 20.4-116.9ppm, T-N 23.2-31.7ppm, $NH_4$-N 18.3-27.7ppm, $NO_2$-N 0.08-1.89ppm, $NO_3$-N 0.19-1.51ppm, $PO_4$-P 2.50-17.28ppm. 2) At Kongdan cheon, the most heavily polluted site, average values of components were pH 8.2, DO trace, COD 116.9ppm, T-N 23.2ppm, $NH_4$-N 18.3ppm, $NO_2$-N 1.89ppm, $NO_3$-N 1.51ppm, $PO_4$-P 17.28ppm. 3) The values of pH, DO, COD, T-N and $NH_4$-N at winter urban streams were higher than those at summer urban streams. And the values of $NO_2$-N and $PO_4$-P were more or less higher at summer urban streams.

  • PDF

A Study on Applicability of Water Pipe Detecting Using GPR (상수관로 탐사에 대한 지중레이더의 적용가능성에 관한 연구)

  • Lee, Won-Jong;Lim, Sung-Min;Choi, Yun-Soo;Min, Kwan-Sik
    • Journal of Cadastre & Land InformatiX
    • /
    • v.45 no.2
    • /
    • pp.131-147
    • /
    • 2015
  • In modern society, as to the underground urban infrastructure facilities(communication electricity water and sewage gas etc.) were contained many risks because of excavating. The exact position of underground facilities and the attribute information should be built in order to prevent accidents. As the result of analyzing the public surveying results from 2004 to 2009, it shows that low detecting rate of water pipeline which is only 52.4%, because the exploration of electromagnetic induction only detect metal pipeline and positioning survey only detect new pipeline before burying. Therefore development and verification of the correct and efficient exploration techniques are needed to improve the detecting rate. In this study, determined based on the location measurement results for the non-metal pipes and metal pipes before burial. It was compared with values that obtained through the ground penetrating radar and electromagnetic induction detecting. As a result, detecting rate of the concrete section showed a 100%, unpaved section showed a 94.7%, asphalt section showed 60%. So it confirmed the applicability of the ground penetrating radar at underground facilities detecting.

Study of structural properties and development of high strength Cured-In-Place Pipe (CIPP) liner for sewer pipes using glass fiber (유리섬유를 이용한 하수관의 고강도 현장경화 비굴착 보수 공법 재료의 개발 및 물성 특성 연구)

  • Ji, Hyon Wook;Koo, Dan Daehyun;Yoo, Sung Soo;Kang, Jeong-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.149-159
    • /
    • 2020
  • Cured-in-place-pipe(CIPP) is the most adopted trenchless application for sewer rehabilitation to extend the life of the existing sewer without compromising both direct construction and indirect social costs especially applied in the congested urban area. This technology is globally and domestically known to be the most suitable for partial and full deteriorated pipe structure rehabilitation in a sewer system. The typical design of CIPP requires a significant thickness of lining to support loading causing sewage flow interruption and increasing material cost. This paper presents development of a high strength glass fiber composite lining material for the CIPP application and structural test results. The test results exhibit that the new glass fiber composite lining material has 12 times of flexural strength, 6.2 times of flexural modulus, and 0.5 Creep Retention Factor. These test results can reduce lining design thickness 35% at minimum. Even though taking into consideration extra materials such as outer and inner films for actual field applications, the structural capacity of the composite material significantly increases and it reduces 20 percent or more line thickness as compared to the conventional CIPP. We expect that the newly developed CIPP lining material lowers material costs and minimizes flow capacity reduction, and fully replaceable to the conventional CIPP lining materials.

A Feasibility Study on Supplying Stream Minimum Flow Using Detention Storage in Developing Planned District (단지계획지구 홍수저류지의 하천유지유량 공급방안 연구)

  • Noh Jaekyoung;Park Hyun-goo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1219-1223
    • /
    • 2005
  • This study was accomplished to confirm the possibility of supplying stream minimum flow from detention storage which was determined to reduce peak flows of flood within developing planned district. The results analyzed was summarized as follows; Firstly, Sin-gil district situated in Ansan city was selected, of which watershed area has $0.56km^2$. And detention storage was determined to $5,370m^3$ from analyzing flood volume by the SCS unit hydrograph method. Secondly, using Visual Basic ver 6.0, a detention storage water balance model was developed, in which simulation was based on conditioning storage inflow and outflow according to streamflow volume or rate state. And streamflow was simulated using the DAWAST model. Thirdly, detention operation scenarios were consisted of the combinations with inflow referencing streamflow of 5mm/day, 10mm/day and outflow referencing streamflow of 1mm/day, 2mm/day. The developed detention storage water balance model was operated to simulate daily water storages of detention sized on flood by scenarios. Stream minimum flows were able to be supplied during 209 days to 237 days per a year, total volume of stream minimum flows supplied for this period was analyzed to reach 27 to $55\% of yearly streamflow volume. If inflow criteria of streamflows to detention was considered to be established on a theoretical condition, it is expected to supply stream minimum flows of 20 to $30\% of yearly streamflow from stream to detention. Also to maximize function of supplying urban stream minimum flow from detention storages, sewage waters within developing planned district have to be treated and entered to detention inflow together with streamflows to enrich function of detention planned to reduce flood volumes.

  • PDF

Application of ecosystem modeling for the assessment of water quality in an eutrophic marine environment; Jinhae Bay (부영양화된 해양환경의 수질개선을 위한 해양생태계모델링의 적용 ; 한국의 진해만)

  • Lee, Won-Chan;Park, Sung-Eun;Hong, Sok-Jin;Oh, Hyun-Taik;Jung, Rea-Hong;Koo, Jun-Ho
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.217-219
    • /
    • 2006
  • This study focused an water quality response to land-based pollution loads and the appropriate pollutant load reduction in Chinhae Bay using an eco-hydrodynamic model. Land-based discharge foam urban areas, industrial complex and sewage treatment plant was the greatest contributor to cause red-tide blooms and summer hypoxia. Tidal currents velocity af the ebb tide was about 10 cm/s stronger than that of the flood tide. A residual current was simulated to. have a slightly complicated pattern with ranging from 0.1 to. 2.7 cm/s. In Masan Bay, pollutant materials cannot flaw from the inner to the outer bay easily because af residual currents flaw southward at surface and northward at the bottom. The simulation results of COD distribution showedhigh concentrations aver 3 mg/L in the inner part of Masan Bay related pollutant discharge, and charge, and lower levels less than 1.5mg/L in the central part of Chinhae Bay. For improvement water quality in Chinhae Bay, it is necessary to reduce the organic and inorganic loads from paint sources by mare than 50% and ameliorate severe polluted sediment.

  • PDF

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures I: Characteristics of the Foul-Smelling Sewer Pipe in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 1: 주거지역 하수관로의 악취 발생 특성)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.621-629
    • /
    • 2007
  • This study intends to investigate the characteristics of the foul smell of sewer pipes near large apartment complexes as complaints about offensive odors have drastically increased in urban residential areas. Targeting apartments where people actually complained about foul orders, the study result revealed that components in the smell of the water-purifier tank of the target apartment were very similar to those of sewage treatment plants and night soil treatment plants. Measuring components of odors inside the management layer of tank showed that the concentration of hydrogen sulfide was 10ppm, which is approximately 160 times the safety standard of 0.06ppm; the concentration of mercaptan was 0.9ppm, which is about 220 times the safety standard of 0.004ppm. The source materials of foul odors were discharged outside through ducts, and those households living near outlets producing bad smell complain that it gets worse depending on the air pressure or wind direction and strength, and they could not even open windows. As well, these source materials were transferred by discharge pumps to public sewer pipes outside the apartment complex. While discharge pumps starts operating, they remain on the sewer pipe and then begin to spread over to roads through small openings of manholes on the road. Then, the smell offends passers-by and residents near the road, leading to a lot of complaints. The study results suggest that, among the sources of foul odors in sewer pipes of residential areas, especially those from the water-purifier tank of large apartments, hydrogen sulfide should be the main target for follow-up treatment.