• 제목/요약/키워드: Urban Environmental Water

검색결과 1,229건 처리시간 0.028초

Performance evaluation of organic matter adsorption from actual graywater using GAC: OrbitrapTM MS and optimization

  • Ligaray, Mayzonee;Kim, Minjeong;Shim, Jaegyu;Park, Jongkwan;Cho, Kyung Hwa
    • Membrane and Water Treatment
    • /
    • 제10권6호
    • /
    • pp.471-484
    • /
    • 2019
  • The complex combination of organic contaminants in the wastewater made water treatment challenging; hence, organic matter in water bodies is usually measured in terms of organic carbon. Since it is important to identify the types of compounds when deciding suitable treatment methods, this study implemented a quantitative and qualitative analysis of the organic matter content in an actual graywater sample from Ulsan, Republic of Korea using mass spectroscopy (MS). The graywater was treated using adsorption to remove the organic contaminants. Using orbitrap MS, the organic matter content between an untreated graywater and the treated effluent were compared which yielded a significant formula count difference for the samples. It was revealed that CHON formula has the highest removal count. Isotherm studies found that the Freundlich equation was the best fit with a coefficient of determination ($R^2$) of 0.9705 indicating a heterogenous GAC surface with a multilayer characteristic. Kinetics experiments fit the pseudo-second order equation with an $R^2$ of 0.9998 implying that chemisorption is the rate-determining step between the organic compounds and GAC at rate constant of $52.53g/mg{\cdot}h$. At low temperatures, the reaction between GAC and organic compounds were found to be spontaneous and exothermic. The conditions for optimization were set to achieve a maximum DOC and TN removal which yielded removal percentages of 94.59% and 80.75% for the DOC and TN, respectively. The optimum parameter values are the following: pH 6.3, 2.46 g of GAC for every 30 mL of graywater sample, 23.39 hrs contact time and $38.6^{\circ}C$.

어류 스트레스 요인으로서 우리나라 하천의 산소과포화 실태 (Oxygen Supersaturation in Korean Streams as a Stress Factor to Fish)

  • 이새로미;이재용;최재석;김선정;안부영;김범철
    • 한국물환경학회지
    • /
    • 제28권2호
    • /
    • pp.213-218
    • /
    • 2012
  • Abnormal dissolved oxygen concentration in aquatic habitat, both depletion and supersaturation, can be stress factor to aquatic animals. In this study the nationwide distribution of oxygen supersaturation was analyzed for three categories of streams (43 urban streams, 15 rural streams, and 14 forest streams) by using monitoring network data of the Korean Ministry of Environment. From the distribution analysis 30% of urban streams showed hyperoxic condition of eutrophic level, while no forest stream showed hyperoxic condition. The physiological effect of hyperoxia on fish was examined using two species of fish Zacco koreanus, which resulted in higher concentration of a stress hormone (cortisol) in fish exposed to hyperoxic concentration (196%) of oxygen. This study shows that hyperoxic condition is ubiquitous in urban and rural Korean streams, and it can be a stress factor to aquatic animals.

Development of a model to forecast the external migration rate in development projects reflecting city characteristics

  • Kim, Ki-Bum;Park, Joon;Seo, Jee-Won;Yu, Young-Jun;Hyun, In-Hwan;Koo, Ja-Yong
    • Environmental Engineering Research
    • /
    • 제23권4호
    • /
    • pp.406-419
    • /
    • 2018
  • In planning public service systems such as waterworks, the design population is very important factor. Owing to the limitations of the indirect method, two new models, which take into consideration urban characteristics, were developed to accurately predict external migration rate (EMR), which is an essential component in estimating reliably the design population. The root mean square error (RMSE) between the model values and observed values were 10.12 and 15.58 for the metropolitan cities and counties respectively and were lower compared to RMSE values of 27.31 and 28.79 obtained by the indirect method. Thus, the developed models provide a more accurate estimate of EMR than the indirect method. In addition, the major influencing factors for external migration in counties were development type, ageing index, number of businesses. On the other hand, the major influencing migration factors for cities were project scale, distance to city center, manufacturing size, population growth rate and residential environment. Future medium and long-term studies would be done to identify emerging trends to appropriately inform policy making.

Benefit of the Drinking Water Supply System in Office Building by Rainwater Harvesting: A Demo Project in Hanoi, Vietnam

  • Dao, Anh-Dzung;Nguyen, Viet-Anh;Han, Mooyoung
    • Environmental Engineering Research
    • /
    • 제18권2호
    • /
    • pp.103-108
    • /
    • 2013
  • Vietnam is a developing country with the rate around 5%-6% per year, especially in urban areas. Rapidly developed urban areas lead to stress for infrastructure and the water supply is also stressed. In Hanoi city, total water capacity from the manufactories is around one million cubic meters per day and almost the entire main water source is groundwater but it is not enough to supply all of Hanoi's people, especially in the summer. A demo project is implemented in Hanoi University of Civil Engineering (HUCE) to produce drinking water by using the rainwater and membrane system and supply for people. In this project, rainwater is collected on the rooftop of the lecture building with an area of around $500m^2$ and $100m^3$ volumetric rainwater tanks. Afterwards, the rainwater is treated by the micro-membrane system and supplied to the tap water. Total cost for construction, technology and operation in the first year is around USD 48,558. In the long-term (15 yr) if HUCE invests in the same system, with $20m^3$ volumetric storage tank, it can provide drinking water for 500 staffs in every year. The cost of investment and operation for this system is lower than 30% compared to buying bottled water with the price USD 1.8/bottle. The drinking water parameters after treatment are pH, 7.3-7.75; turbidity, 0.6-0.8 NUT; total dissolved solids, 60-89 mg/L; coliform, 0; heavy metal similar with water quality in the bottle water in Vietnam.

原州川의 水質汚染에 관한 調査硏究 (A Study on the Water Pollution of the Wonju Stream)

  • Park, Byoung Youn;Ra, Kyu Hwan;Ok, Chi Sang
    • 한국환경보건학회지
    • /
    • 제11권1호
    • /
    • pp.1-8
    • /
    • 1985
  • Urban sewage and stream water in Wonju city were examined and the results were as follows: The average water quality of Wonju stream was flow 52.8m$^3$/min, BOD 21.14ppm, COD 7.06 ppm, SS 212.4ppm, Cl$^-$ 23.14ppm, O-Phosphate 1.08ppm, NH$_3$-N 1.08ppm, NO$_2$-N 2.63ppm and pH 7.48 respectively. The average water quality of urban sewage was flow 2.76m$^3$/min, BOD 112.7ppm, COD 33.6ppm, SS 374.4ppm, Cl$^-$ 46.2ppm, O-Phosphate 1.56ppm, NH$_3$-N 5.96ppm and NO$_2$-N 3.28 ppm respectively. The quality of stream water showed was 4th grade area according to environmental water quality standard. The survey showed k$_1$ 0.11day$^{-1}$, k$_2$ 0.29day$^{-1}$ and the self- purification coefficient 2.5 in average.. In calculating oxygen variation in water by Streeter-Phelp's equation the zero station exhibited in down stream.

  • PDF

댐 배수조작에 따른 저수지내 탁수변화 모의 - 대청댐을 대상으로 - (Simulation of Turbid Water in the Stratified Daecheong Reservoir during Gate Operation)

  • 이재일;서세덕;이규성;하성룡
    • 환경영향평가
    • /
    • 제18권6호
    • /
    • pp.377-386
    • /
    • 2009
  • Due to severe flooding, the long-term residence of turbidity flows within the stratified Daecheong Reservoir have lengthened. A long-term residence of turbidity flows within the stratified Daecheong Reservoir after floods has been major environmental issue. The objective of this study was to assess the impact to water supply from the hydrodynamics and turbidity outflow. Two gate operation scenarios were investigated. Scenario A refers to gate operations according to rainfall events, and scenario B refers to gate operations according to inflow. From the results of secenario A, the SS concentrations decreased from 0.44mg/l to 0.54mg/l at the front of the dam, whereas SS concentrations increased from 0.24mg/l to 1.24mg/l at the intake points at Munhi and Daejeon. From the results of scenario B, the SS concentrations decreased from 0.61mg/l to 0.83mg/l at the front of Dam; howeve, SS concentrations also decreased from 0.16mg/l to 0.48mg/l at the intake points at Munhi and Daejeon. It seems that it may be more efficient to control turbidity by creating additional outflows of generated discharge after intensive rainfalls than not.

수공간 조성을 통한 도시의 열섬현상 저감효과 분석 - 대전시 노은지구 열매마을아파트를 중심으로 - (Analysis on the Mitigation Effects of Urban Heat Island through Creation of Water Space - A case study of Yeol-Mae village Apt in Daejeon's Noeun District -)

  • 박기용;이선우;심용주;황희연
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.13-18
    • /
    • 2011
  • The overall aim of this study is to mitigate urban environmental problems. In particular, to reduce the effects of urban heat island phenomenon which is one of the urban planning perspective. This study focused on the analysis of the relationship between the urban heat island effect and the thermal and wind properties. To do this analysis, water space was virtually made at Yeol_Mae village Apt. Because it is very difficult to set up water space for the existing apartment complexes due to realistic constraints. This study, therefore has a strong sort of guidelines to create water space for newly formed city. It was based on the concept of virtual city through an in-depth analysis on reduction of urban heat island effects for the existing apartment along with creation of water space. To analysis site, Envi-Met Model developed by Michael Bruse was used. The results are as follows. The temperature went from 298.9K to 297.82K and The wind speed went from 1.42m/s to 1.43m/s. The results are slight in this study because creation of water space is planned to a small area of an apartment complex. But if the water space would be applied to a whole city, the mitigation effect of urban heat island would be bigger.

도시 수자원 리빙랩 적용사례 분석: 김해시 삼방워터 리빙랩을 중심으로 (Analysis of Application Cases of Living Lab for Urban Water Resources: Focusing on Sam-bang Water Living Lab)

  • 이남정;이정훈;금아로
    • 한국IT서비스학회지
    • /
    • 제20권6호
    • /
    • pp.141-150
    • /
    • 2021
  • With the recent spread of the concept of Smart Cities which is to solve urban problems with ICT technology, Living Lab, which identifies the demands of citizens who dwell in the city and verifies the acceptability of the services being introduced, has become an important topic. Living Lab is an open innovation platform introduced in consideration of the user's perspective in real life and is a new approach in that service developers use collective intelligence in the process of Co-creation with users. Living Lab is operated on topics which is close to citizens' daily lives such as energy, housing, transportation, and education. In particular, as energy and environmental-focused Living Lab emerges in accordance with the 'Korean New Deal Policy', interest and importance in the field are increasing. The paper derives the characteristics of water resource Living Lab through case analysis of several Living Lab practices. Water resource Living Lab in Daejeon and Chuncheon, which are located in Korea, and water resource Living Lab in Romania and Indonesia are covered in this paper as the reference. The paper finally analyzes the case of Sambang Water Living Lab in Gimhae, which is the city located in southern part of Korea. As a result of case analysis, the urban water resource Living Lab focuses on the raw water of urban water resource and should respond sensitively to the safety of citizens. And for the success of this urban water resource Living Lab, it is essential to ensure that citizens participating in the Living Lab clearly understand the concept of water resources, and citizens' opinions to be implemented as services.

Estimating the Air Temperature Cooling Effect of the Cheonggyechun Stream Restoration Project of Seoul, Korea

  • Park Chong-Hwa;Kwon Young-Sang
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • 제2호
    • /
    • pp.120-129
    • /
    • 2004
  • Urban stream restoration projects can improve water quality, wildlife habitats, urban landscape, outdoor recreation spaces, and urban microclimate. The objectives of this research were to investigate temperature cooling effect of urban streams by using satellite imagery, to evaluate environmental variables related to stream cooling effect, and to estimate the cooling effect of the Cheonggye stream restoration project of Seoul, Korea. Findings of this research can be summarized as follows. First, a method of estimating temperature distribution around urban streams by using satellite imagery was developed. Scatter plots of distance from stream edges and average temperature obtained through multiple buffering were used for the estimation. Second, urban temperature cooling effect of streams was estimated by comparing background temperature and temperature of each buffer zone. Third, environmental factors affecting stream cooling effect were also identified. Fourth, the temperature cooling effect of the restoration project was estimated based on three scenarios. An estimated cooling effect based on the average cooling effect of existing tributaries showed the most significant effect; $2.0^{\circ}C$ lower than the present level at the edge of the renovated stream. It was estimated that the temperature of the same area would be $1.4^{\circ}C$ cooler than the present level if the cooling effect of the Yangjaechun was used as the bench mark But the effect would be $1.2^{\circ}C$ lower than the present level if environmental variables related to the temperature cooling effect of urban streams were used as the bench mark.

  • PDF

수원시 비점오염물질의 유출 특성 (Runoff Characteristics of Non-point Pollutants Source in Suwon City)

  • 지홍진;이상은;이재동
    • 한국환경과학회지
    • /
    • 제22권4호
    • /
    • pp.493-505
    • /
    • 2013
  • This study was to investigate the runoff characteristics of non-point pollutants source at the urban area in Suwon city. The highest T-N and T-P concentration of rainfall runoff observed in agricultural area. In residential area, the highest $BOD_5$ and SS concentration of rainfall runoff was investigated. During rainfall events, the peak concentrations of SS and $BOD_5$ were observed after 1~2 hours of rainfall in urban area. Whereas, the peak concentrations occurred within 1~2 hours after rainfall and then the highest concentrations of SS and $BOD_5$ sharply decreased, showing strong first flush effect in urban area. The EMC results indicated that the highest value of T-N and T-P in agricultural area was observed. While residential area was shown the lowest EMC value as T-N and T-P. Non-point pollutant loads on the land use types in urban area were investigated in the order of residential>industrial>agricultural>highway. $BOD_5$ and SS loads on urban watershed were investigated in the order of Suwon>Hwangguji>Seoho>Wonchunri. Whereas, T-N and T-P loads on urban watershed were investigated in the order of Hwangguji>Suwon>Wonchunri>Seho.