• 제목/요약/키워드: Upward flow

검색결과 317건 처리시간 0.037초

수직상향 기체 주입에 따른 기포 및 액상의 유동분석 (Flow Analysis of Bubble and Liquid Phase by Vertical Upward Gas Injection)

  • 서동표;오율권
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.727-732
    • /
    • 2003
  • In the present study, a PIV measurement and image processing technique were applied in order to investigate the flow characteristics in the gas injected liquid bath. The circulation of liquid was induced by upward bubble flow. Due to the centrifugal force, the flow was well developed near both wall sides than in the center of a bath. The vortex flow irregularly repeated generation and disappearance which helped to accelerate the mixing process. The bubble rise velocity in the bottom region was relatively lower than in the upper region because the energy generated by bubbles' behavior in the region near the nozzle was almost converted into kinetic energy But bubble rise velocity increases with the increase of the axial distance since kinetic energy of rising bubbles is added to buoyancy force. In conclusion, the flow increased bubble rise velocity and the flow of the bottom region became more active.

통계적 보이드율계측에 의한 수직상향이상류의 유동양식과 보이드분포 분석 (Analyses of the Flow Patterns and Void Distribution in Vertical Upward Two Phase Flow with the Statistical Void Fraction Measurement)

  • 손병진;김인석;이진
    • 대한설비공학회지:설비저널
    • /
    • 제15권3호
    • /
    • pp.283-291
    • /
    • 1986
  • An experimental study has been conducted to investigate characteristics of the flow patterns, its transitions and the mean local void fraction obtained from which the probe was traversed diametrically from center to wall of the test section in the vertical upward air-water flow for isothermal condition using the electrical conductivity probe. It has been shown that the probability density function of the mean local void fraction measured statistically from a Fast Fourier Transform becomes a criterion for the flow patterns and the mean local void fraction profile is a highly function of the flow patterns.

  • PDF

Envi-met 모델을 이용한 도심지역 대기오염측정망 주변의 바람장 분석 (An Analysis of Wind Field around the Air Quality Monitoring Station in the Urban Area by Using the Envi-met Model)

  • 김민경;이화운;도우곤;정우식
    • 한국환경과학회지
    • /
    • 제18권9호
    • /
    • pp.941-952
    • /
    • 2009
  • The urban microscale wind field around the air quality monitoring station was investigated in order to check how a building complex influences it. For this study as the high density areas Jwa-dong and Yeonsan-dong monitoring sites in Busan were chosen. As the direction of inflow which is perpendicular to the building of the monitoring station was expected to cause the considerable variation of the wind field, that direction was selected. The model Envi-met was used as the diagnostic numerical model for this study. It is suitable for this investigation because Envi-met has the microscale resolution. After simulating it, on the leeward side around a building complex the decrease of flow velocity and some of vortexes or circulation area were discovered. In addition, on the edge of the top at the building and at the back of the building the upward flow was developed. If the sampling hole of monitoring site were located in this upward flow, it would be under the influence of upward flow from the near street.

발열체와 부분 열림 수직벽을 갖는 사각 공간 내 자연대류 특성 해석 (A Study on the Characteristics of Natural Convection in a Partially Opened Enclosure with a Heat Source)

  • 심동식;강보선;차동진;주원종
    • 대한기계학회논문집B
    • /
    • 제24권12호
    • /
    • pp.1588-1595
    • /
    • 2000
  • Natural convection heat transfer in an enclosure with an opening in the right veritcal wall and a heat source at the bottom surface is investigated using a holographic interferometric technique. The effects of the opening length, divider length attached to the top wall, and heater temperature on the temperature distribution are examined. The opening length as well as the divider length greatly affects the degree of inflow and outflow of air. In the case of small opening length, the opening doesnt affect much the upward warm air flow resulting in the symmetric temperature distribution .The upward flow in hindered by the divider resulting in the decrease of heat transfer from the heater region to the upper region. The longest divider shows the highest temperature in the lower region of enclosure. In the case of large opening length, the inward cold flow moves the upward flow to the left direction. Among the cases of different divider length, the case of H(sub)d=0.25H shows the highest temperature in the lower region of enclosure.

저온의 물속에 잠겨있는 수평 평면에 의하여 야기되는 자연대류의 수치해석 (Numerical Analysis of Natural Convection from a Horizontal Surface Immersed in Cold Water)

  • 유갑종;예용택;권혁용
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1195-1204
    • /
    • 1992
  • 본 연구에서는 등온 평면의 온도가 0.0.deg. C부터 8.0.deg. C까지, 그리고 주위물의 온 도가 1.0.deg. C부터 10.0.deg. C까지 일 대 상향 및 하향면 주위에서 일어나는 자연대류를 유한 차분법(FDM)으로 수치해석하여 등온면 주위에서 일어나는 유동형태, 속도분포, 평균 Nusselt수를 구하여 유동 및 열전달특성을 구명하였다.

유체간섭을 동반하는 헬륨과 공기의 치환류 (Helium-Air Exchange Flow with Fluids Interaction)

  • T.I. Kang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.372-380
    • /
    • 1997
  • This paper describes experimental investigations of helium-air exchange flows through parti¬tioned opening and two-opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with the two types of small open¬ing on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. In the case of exchange flow through the partitioned opening, flow passages of upward flow of the helium and downward flow of the air within the opening are separated by vertical partition, and the two flows interact out of entrance and exit of the opening. Therefore, an experiment of the exchange flow through two-opening is made to investigate effect of the fluids interaction of the partitioned opening sys¬tem. As a result of comparison of the exchange flow rates between the two types of the opening system, it is found that the exchange flow rate of the two-opening system is larger than that of the partitioned opening system due to absence of the effect of fluids interaction. Finally, the fluids interaction between the upward and downward flows through the partitioned opening is found to be an important factor on the helium-air exchange flow.

  • PDF

편재된 비대칭형 전류고정날개 추진시스템에 관한 연구 (A Study on the Design of a Biased Asymmetric Pre-swirl Stator Propulsion System)

  • 김문찬;강용덕;전호환
    • 대한조선학회논문집
    • /
    • 제41권3호
    • /
    • pp.13-21
    • /
    • 2004
  • This paper deals with a theoretical and experimental method for the design of a biased asymmetric pre-swirl stator propulsion system which is an energy saving device by recovering a propeller rotational energy. In the case of slow-speed ships, the upward flow is generated along the afterbody hull form at the propeller plane. The generated upward flow cancels the rotating flow of the propeller at the starboard part while it increases at port part. The present biased asymmetric pre-swirl stator propulsion system consists of three blades at the port and one blade at the starboard which can recover the biased rotating flow effectively. This paper provides the design concept which gives more simple and a high degree of efficiency and the experimental results for the compound propulsion system.

T형 수평 및 수직 입구 분지관 내 냉매 2상 유동 특성 (Two-phase Flow Characteristics of Refrigerant in T-branch with Horizontal and Vertical Inlet Tube)

  • 태상진;조금남
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.741-748
    • /
    • 2002
  • The present study investigated the two-phase flow characteristics of refrigerant R-22 in T-branch with horizontal and vertical inlet tube The key experimental parameters were the orientation of inlet and branch tubes (horizontal and vertical), diameter ratio of branch tube to inlet tube (1 and 0.61), inlet mass flux (200~500 kg/$m^2$s) and inlet quality (0.1~0.4). Predicted pressure profile agreed with the measured data within 25.4%. The flow distribution ratio decreased as the mass flux increased. The flow distribution ratio decreased by 12~25% as the tube diameter ratio decreased from 1 to 0.61, and decreased by 38~47% as the orientation of branch changed from horizontal to vertical upward for horizontal inlet tubes. As the orientation of inlet tube changed from horizontal to vertical upward for horizontal branch, the flow distribution ratio increased by 15~68%, but the quality in the branch tube decreased by 28~92% due to phase separation.

경사진 평판에서의 자연대류 열전달 (Natural Convection Heat Transfer on Inclined Plates)

  • 임철규;허정환;정범진
    • 대한기계학회논문집B
    • /
    • 제35권7호
    • /
    • pp.701-708
    • /
    • 2011
  • 기울어진 평판에서 발생하는 자연대류 열전달현상을 $R_{a_L}$ $1.69{\times}10^{11}$$7.23{\times}10^{12}$에 대하여 실험적으로 연구하였다. 유사성을 이용하여 열전달실험을 물질전달 실험으로 대체하였고 물질전달계로 전기도금계를 사용하였다. 평판의 기울기는 상향수평에서 하향수평까지 $10^{\circ}$씩 변화시켰다. 하향평판에서는 수직 벽면에 대한 자연대류 열전달 상관식에서 g 대신 g $cos{\theta}$로 대체함으로써 열전달계수를 구할 수 있다는 기존의 이론과 일치하는 결과를 얻었다. 상향평판의 경우 경계층이 벽면을 따라 발달되는 경우와 벽면으로부터 박리되는 2가지 영역으로 구분되는데 박리에 따른 열전달 증가를 확인하였다. 아울러 도금패턴을 이용하여 박리지점을 시각화하였고 박리지점에 대한 분석이 수행되었다.