• Title/Summary/Keyword: Upper Pad

Search Result 71, Processing Time 0.025 seconds

A Histochemical Study of the Masseter Muscle Fibers of White Rat with Unilateral Edentulous Jaw (편측 무치악이 백서 교근 근섭유에 미치는 영향에 관한 조직화학적 연구)

  • Hong-Ryeol Ryu;Sung-Woo Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.13 no.1
    • /
    • pp.61-69
    • /
    • 1988
  • The study of the muscle fiver composition and the muscle fiver type conversion during unilateral edentulous condition was undertaken in the rostral superficial masseter muscle of the whiter rat. 16 4-week-old male white rats weighting approximately 130gm that crowns of left upper and lower molare were cut intentionally, were divided into 4 groups (one control group and 3 experimental groups). After experimental groups were sacrificed by etherization in 6 days($E_1$), 18 days($E_2$) and 36 days($E_3$) separately, samples of the rostral superficial masseter muscle were obtained bilaterally and the proportion of type I, type IIA, type IIB, and type IIC fibers was determined and counted according to their histochemical activity of myosin ATPase (at pH 9.4, pH 4.6, and pH 4.2)and PAD staining. The obtained results were as follows : 1. The rostral superficial masseter muscle of the white rat contained approximately 47.5% type I fiber and 52.5% type II fiber. 2. Type I/ Type II ratio of molar-present side was increased significantly in the group E2 (18 days group) 3. Type IIA fiber was increased at molar-present side and decreased at molar-absent side in experimental groups.

  • PDF

Development and Evaluation of Wearable Device with Heat and Massage Function (안마 및 발열기능의 스마트 조끼 개발과 성능 및 만족도 평가)

  • Roh, Eui Kyung;Yoon, Mi Kyung
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.676-685
    • /
    • 2020
  • This study developed smart vests with heat and massage functions that changed patterns, designs, materials, etc., and evaluated their functions and satisfaction. A knitted fabric with good elasticity and a heating lining were used, and in consideration of this, the final vest pattern fitted to the upper body was completed. A heat pad was attached to the back, and 6 vibration motors were attached to the trapezius muscle. The controller was placed on the left chest for easy operation, and the battery was stored in an inner pocket under the controller. The heating effect of the smart vest, the location of the devices, and the ease of operation were excellent. When the massage function was operated, the thermal comfort was increased compared to when the massage function was not operated, and the high thermal comfort was perceived by the operation of heat and heat+massage function. Due to the battery, the weight, irritating contact of devices and wearing sensation decreased, but there was no reduction in wearing sensation due to heat and vibration devices. The greater the satisfaction with the massage function, thermal comfort, fit, appearance and weight, the greater the product satisfaction.

A Preliminary Study on the Fitness of Adjustable Dental Impression Trays (가변형 치과 인상용 트레이의 적합도에 관한 예비연구)

  • Kim, Min-Jeong;Oh, Sang-Chun;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.83-93
    • /
    • 2005
  • This study was designed to investigate the fitness of adjustable dental impression trays. The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. A hundred dental students(male:50, female:50) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. The results obtained were as follows : 1. Uniform impression material thickness was achieved by controlling the width of the tray using stops and beveled guides. 2. In the upper tray, the impression material thickness was measured to be rather great showing thickness of the labial vestibule 8.3 mm and the midpalatal part 8.6 mm. 3. In the lower tray, length of the impression material of the labial vestibule of first, second premolar contact point was 7.8 mm, and thickness of the lingual part of premolars(1.8 mm) and molars(1.9 mm) showed small values. 4. In the lower tray, the impression material thickness of the buccal shelf area(0.2 mm) and the retromolar pad area(0.6 mm) was measured to be too small.

Kinematical Analysis of Heel-Brake Stop in Inline Skate (인라인 스케이트(Inline Skate) 힐 브레이크(Heel-Brake) 정지에 관한 운동학적 분석)

  • Han, Jae-Hee;Lim, Yong-Kyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.11-20
    • /
    • 2005
  • This study has a purpose on contributing to apprehend safe and right way to stop to the inline skate beginners and to the instructors who teaches line skating on the basis for the result of the kinematical analysis on Heel brake stop movement of the inline skate, focusing on the displacement on COG, angle displacement of ankle joint, angle displacement of knee joint, angle displacement of hip joint, using a 3D image method by DLT. To achieve this goal, we analysed the kinematical factor of the 3 well-trained inline skating instructors and obtained the following results. 1. During the movement of heel-brake stop, when strong power was given to a stable and balanced stop and the lower limbs, if the physical centroid is lowered the stability increases, and if it is placed high from the base surface, as the stability decreases compared to the case of low physical centroid, we should make a stop by placing a physical centroid in the base surface and lowering the hight of physical centroid. 2. To make a stable and balanced stop and to provide a strong power to the lower limbs, it is advisable to make a stop by decreasing an angle displacement of ankle joint during a "down" movement. In case of the left ankle joint, in all events and phases the dorsiflexion angle showed a decrease. Nevertheless, in the case of the right ankle joint, the dorsiflexion angle shows an increase after a slight decrease. The dorsiflexion angle displacement of ankle joint can be diminished because of the brake pad of the rear axis frame of the right side inline skate by raising a toe, but cannot be more decreased if certain degree of an angle is made by a brake pad touching a ground surface. To provide a power to a brake pad, it is recommended to place a power by lowering a posture making the dorsiflexion angle of the left ankle joint relatively smaller than that of the right ankle. 3. To make a stable and balanced stop and to add a power to a brake pad, the power must be given to the lower limbs in lowering the hight of physical centroid. For this, it is recommended to make a down movement by decreasing the flexion angle of a knee joint and it is necessary to make a down movement by a regular decrease of the angle displacement of knee joint rather than a swift down movement in every event and phase. 4. The right angle displacement of hip joint is made by lowering vertically the hight of physical centroid as leaning slightly forward. If too narrow angle displacement of hip joint is made by leaning forward too much, the balance is lost during the stop by placing the center in front. To make a stable and balance stop and to place a strong power to the lower limbs, it is recommendable to make a narrow angle by lower the hip joint angle. However, excessive leaning of the upper body to make the angle too narrow, can cause an instable stop and loss of physical centroid. After this study, it is considered to assist the kinematical understanding during the heel brake stop movement of the inline skate, and, to present basic data in learning a method of stable and balanced stop for the inline skating beginners or for the inline skate instructors in the present situation of the complete absence of the study in inline skating.

Sub-brow Resection via Relocation of Retro-orbicularis Oculi Fat and Preseptal Fat Unit (눈둘레근뒤 지방과 앞사이막 지방 단위의 재배치술을 통한 눈썹하 절제술)

  • Cha, Jeong-Ho;Woo, Sang-Min;Kim, Jin-Woo;Jung, Jae-Hak;Kim, Young-Hwan;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.477-484
    • /
    • 2011
  • Purpose: Retro-orbicularis oculi fat (ROOF) and preseptal fat pad (PSF) are deep fat structures of frontal and supraorbital area, that encounter galeal fat pad (GFP). If galeal wall is weakened by aging process, GFP loses its anchoring structure, moved downward pushing ROOF and PSF. This especially occur in lateral brow area. As a result of drooping, eyebrow affects the eyelid covering PSF as a sac descended to a lateral hooding and ptotic eyelid simultaneously. Consequently, in the case of lateral hooding and brow ptosis, besides the skin, deep fat structures (ROOF and PSF) should be corrected as well. Methods: ROOF-PSF repositioning technique in subbrow resection were performed. 21 cases of patients from April, 2007 to January, 2008. Before surgery, all patients were examined carefully to evaluate the degrees of dermatochalasia, drooping of the eyebrow, marginal reflex distance 1 (MRD1), eyelid crease height. Surgery was performed under local anesthesia, then excised the drooped eyelid skin by lateral subbrow resection, removed proper amount of ROOF, repositioned ROOF-PSF at the supraorbital rim, and fix it on periosteum. During follow up periods, the patients were surveyed of the satisfaction of surgery, and postoperative MRD1 was evaluated. Results: One patient had a hematoma on left eyebrow, and another one patient had a numbness on left forehead for two months. Except for these two patients, all patients had good results without any significant complications. The mean follow up period was about 5 months, and the position of lateral eyebrow maintained above the supraorbital rim in all cases. Postoperatively, MRD1 increased by 0.8 mm in 5-months mean follow up period. Conclusion: In patient with lateral brow ptosis and lateral hooding, the ROOF-PSF repositioning technique in sub-brow resection could be a good operative option.

The Effect on Attention of College Students by Epidermal Cooling in Posterior and Lateral of Upper Cervix (경추부 후면 및 측면 피부 냉각 작용이 대학생의 주의력에 미치는 영향)

  • Chang, Ji Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.5
    • /
    • pp.328-334
    • /
    • 2022
  • The process that one may consciously focuses on necessary stimulation among tremendous amount of stimulation through human sensory systems is called attention in psychology. It is known that the attention can be affected by many factors such as room temperatures, humidity level, etc. In the field of sports science, ice packs are widely used for recovery from exercise fatigue providing fast heat transfer by conduction. However, the effect on attention by so-called iced-pack-cooling has not been tested. This research focuses on the attention levels when one is provided with a special cooling pad on their dorsal and lateral cervices. 40 subjects were divided into four groups and their attention level was evaluated based on the exposure conditions of combinations in reading and light walking with and without the cooling pad. The Frankfruter Aufmerksamkeits-Inventar, FAIR was used to evaluate the attention levels; the performance index, quality index, and continuity index consist of the FAIR test indicating the selectiveness of the attention, correctness of the attention, and maintaining term of the attention, respectively. Analysis of variance was carried out for those variables and post-hoc if applicable. When visual attention is constantly used for reading and studying, application of conductive heat transfer by the cooling pads is significantly helpful for improvement in selectiveness of the attention and maintaining terms of the attention levels. Also, light walking yielded improvement in selectiveness of the attention and maintaining terms of the attention levels; however one should presupposedly consider the loss of reading time.

Comparative study of volumetric change in water-stored and dry-stored complete denture base (공기중과 수중에서 보관한 총의치 의치상의 체적변화에 대한 비교연구)

  • Kim, Jinseon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.18-26
    • /
    • 2021
  • Purpose: Generally, patients are noticed to store denture in water when removed from the mouth. However, few studies have reported the advantage of volumetric change in underwater storage over dry storage. To be a reference in defining the proper denture storage method, this study aims to evaluate the volumetric change and dimensional deformation in case of underwater and dry storage. Materials and methods: Definitive casts were scanned by a model scanner, and denture bases were designed with computer-aided design (CAD) software. Twelve denture bases (upper 6, lower 6) were printed with 3D printer. Printed denture bases were invested and flasked with heat-curing method. 6 upper and 6 lower dentures were divided into group A and B, and each group contains 3 upper and 3 lower dentures. Group A was stored dry at room temperature, group B was stored underwater. Group B was scanned at every 24 hours for 28 days and scanned data was saved as stereolithography (SLA) file. These SLA files were analyzed to measure the difference in volumetric change of a month and Kruskal-Wallis test were used for statistical analysis. Best-fit algorithm was used to overlap and 3-dimensional color-coded map was used to observe the changing pattern of impression surface. Results: No significant difference was found in volumetric changes regardless of the storage methods. In dry-stored denture base, significant changes were found in the palate of upper jaw and posterior lingual border of lower jaw in direction away from the underlying tissue, maxillary tuberosity of upper jaw and retromolar pad area of lower jaw in direction towards the underlying tissue. Conclusion: Storing the denture underwater shows less volumetric change of impression surface than storing in the dry air.

The Effects of Gabapentin on Facial Formalin Test (백서에서 Gabapentin 전신투여가 Facial Formalin Test에 미치는 영향)

  • Kim, Chul-Hong;Baik, Seong-Wan;Kim, Hae-Kyu;Kwon, Jae-Young;Kim, Kyoung-Hun;Choi, Sung-Hwan
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.3 no.2 s.5
    • /
    • pp.92-97
    • /
    • 2003
  • Background: Gabapentin is a novel anti-epileptic drug, which is used in clinical practice to treat epilepsy. This drug is also used as an analgesic in pain patients. The antinociceptive effect of this drug was assessed using the formalin test in the rat. Methods: In order to investigate the effects of gabapentin on the trigeminal nerve territory, we injected 0.5% formalin into the upper lip. Adult, male, Sprague-Dawley rats received a $50{\mu}l$ subcutaneous injection of 5% formalin into one vibrissal pad and the consequent, facial grooming behavior was monitored. Consistent with previous investigations using tile formalin model, animals exhibited biphasic nocifensive grooming (phase 1, 0-12 min; phase 2, 12-60 min). Results: The intraperitoneal administration gabapentin 5 minutes prior to the formalin injection led to a significant, dose-dependent reduction in grooming time during phase 2. In high doses, gabapentin also reduced the time of grooming during phase 1. Conclusions: The Intraperitoneal injection of gabapentin has an analgesic effect in the facial formalin rat model and this analgesic effect increases dose-dependently.

  • PDF

Eyebrow Lift and Malar Fat Lift by Absorbable Suture Fixation with Subperiosteal Dissection (골막하 박리와 흡수성 봉합사에 의한 눈썹과 광대지방층의 거상술)

  • Chung, Jaehoon;Lee, Yoonhoo;Jang, Chunghyun
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.262-266
    • /
    • 2005
  • In some blepharochalasis patients, upper blepharoplasty alone is not satisfactory because of narrow distance between eyebrow and eyelash. On that occasion, eyebrow lift is advisable. There are many methods of classical eyebrow lift, such as direct excision, transblepharoplasty approach, anterior hairline technique, and so on. But they are not so effective, have a tendency to recur and also give rise to side effects; unacceptable scar, facial nerve palsy, sensory loss and hematoma, etc. Some patients who have prominent nasolabial folds, are reluctant to perform face lift procedure due to psychologic or economic burden. The authors performed the eyebrow lift procedure separately or simultaneously with face lift or forehead lift. After making 2 or 3 slit incisions, we passed absorbable suture material, 3-0 vicryl, through suborbicularis oculi fat layer. Then it was passed through subperiosteal plane and fixated to the temporalis fascia. When patients complain prominent nasolabial folds, malar fat pad was elevated also in the same manner. This methods is effective and has minimal complication such as facial nerve palsy, scar, sensory loss. Recurrent tendency was rarely observed during follow-up. Dimples were observed at slit incision sites but they disappeared within 2 or 3 weeks. Eyebrow lift and malar fat lift by absorbable suture elevation with subperiosteal dissection is a simple and less morbid. Because of its effectiveness and little side effect or complication, this procedure can be a useful method.

Simulation of Ultrasonic Stress During Impact Phase in Wire Bonding

  • Mayer, Michael
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.4
    • /
    • pp.7-11
    • /
    • 2013
  • As thermosonic ball bonding is developed for more and more advanced applications in the electronic packaging industry, the control of process stresses induced on the integrated circuits becomes more important. If Cu bonding wire is used instead of Au wire, larger ultrasonic levels are common during bonding. For advanced microchips the use of Cu based wire is risky because the ultrasonic stresses can cause chip damage. This risk needs to be managed by e.g. the use of ultrasound during the impact stage of the ball on the pad ("pre-bleed") as it can reduce the strain hardening effect, which leads to a softer deformed ball that can be bonded with less ultrasound. To find the best profiles of ultrasound during impact, a numerical model is reported for ultrasonic bonding with capillary dynamics combined with a geometrical model describing ball deformation based on volume conservation and stress balance. This leads to an efficient procedure of ball bond modelling bypassing plasticity and contact pairs. The ultrasonic force and average stress at the bond zone are extracted from the numerical experiments for a $50{\mu}m$ diameter free air ball deformed by a capillary with a hole diameter of $35{\mu}m$ at the tip, a chamfer diameter of $51{\mu}m$, a chamfer angle of $90^{\circ}$, and a face angle of $1^{\circ}$. An upper limit of the ultrasonic amplitude during impact is derived below which the ultrasonic shear stress at the interface is not higher than 120 MPa, which can be recommended for low stress bonding.