• Title/Summary/Keyword: Up-Up Method

Search Result 17,086, Processing Time 0.047 seconds

A Study on Perception of Face Image of Point Make-up by demographic variables and preferences of the point make-up (인구통계적 변인에 따른 부분색채화장 이미지지각과 선호도에 관한 연구)

  • 이연희;양취경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.3_4
    • /
    • pp.515-526
    • /
    • 2002
  • The purpose of this study will find out the primary element of point make-up image perception, the point make-up image perception by point make-up trend and demographic variables such as sex and age. And this study will show the preferences of the point make-up. This study is based on the quasi-experimental study method with contents analysis method and experimental method. And content ana]isis is primarily based on the color trend and cosmetics colors which were suggested by a fashion magazine. Experiment was conducted by gathering opinions by poll, with the model wearing different make-ups and checking the typical reactions of people. To summarize, sex and age were found out to be influential variable to distinguish color perception abilities. This could verify that point make-up was important factor, influencing on the face image perception. also, face make-up effect could be maximized with Natural or common color groups rather than trend-oriented color group selections. And the polled preferred Natural color group with no point make-up or Classic color group to any other color group.

Comparative Study on the HPLC Determination of Aflatoxins Coupled with Extraction and Clean-up Methods (Aflatoxin 분석법에 관한연구;추출 및 정제방법의 비교)

  • 김종규
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.4
    • /
    • pp.251-254
    • /
    • 1993
  • Extraction and Clean-up procedures coupled with quantitation by high performance liquid chromatography(HPLC) was evaluated for the detection of 4 aflatoxins, B1, B2, G1 and G2, in peanut butter. The Sep-pak clean-up method showed poorer separation and repeatability than did the modified DeVries' and an immunoaffinity column clean-up methods. No significant difference of detected aflatoxins between the affinity column clean-up and modified DeVries' method. The coefficients of variation for the 4 aflatoxins were ranging from 6.3∼32.3 by the modified DeVries' method and 5.3∼9.8 by the affinity column clean-up.

  • PDF

A Study on the Start-up Control for HDD Spindle Motors (HDD 스핀들 모터의 초기 구동 제어에 관한 연구)

  • Jeong, Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.869-873
    • /
    • 2008
  • Optimization method for the open loop commutation time intervals in HDD spindle start-up control is presented in this paper. A hard disk drive(HDD) uses a sensorless brushless DC motor(BLDC) for the platter rotation. Because there is no direct sensor for the rotor position, open loop commutations after sensing the rotor position at a standstill using inductive sensing method are performed to speed up the rotor up to a certain speed where the zero crossings of the back electromotive force(EMF) are measurable. Therefore successful open loop commutations are necessary for the stable start-up control of the spindle motors. Random neighborhood search(RNS) algorithm is introduced as a optimization technic in this paper. Rotor speed and its standard deviation are used as a cost function and commutation intervals obtained from the spindle motion equation are used as initial parameter values for the RNS. With the help of the proposed method optimized open loop commutation time intervals for the very low start-up current are acquired and tested. The experimental results shows that the proposed method can decrease the start-up failure rate of a HDD spindle motor.

  • PDF

Calibration of an Optical Pick-up Performance Evaluator (광 픽업 성능 평가기 캘리브레이션)

  • Ryoo, Jung Rae;Doh, Tae-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.5
    • /
    • pp.578-583
    • /
    • 2014
  • Optical pick-up is a core component for data read/write operations in optical disc drives, and an optical pick-up performance evaluator is an instrument used to analyze the overall performance of an optical pick-up. Due to inevitable errors in an analog measurement circuit, resultant evaluation data is not guaranteed to be accurate. In this paper, a calibration method for an optical pick-up performance evaluator is proposed to ensure evaluation accuracy. Measured data is corrected by a 1st order correction function, and a calibration process based on least-square method is utilized to obtain correction coefficients of the correction function. The proposed calibration method is applied to experiments, and enhanced accuracy is presented with resultant evaluation data.

Numerical Approach to Evaluate the Behavior of Concrete Panel Considering Construction Method (수치해석을 이용한 시공방법에 따른 판넬식 옹벽의 거동 분석에 관한 연구)

  • Junhee, Kang;Hoki, Ban
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.12
    • /
    • pp.17-23
    • /
    • 2022
  • This paper analyze the precast panel retaining wall's safety factor changes based on the numerical analysis using PLAXIS 2D software. Numerical analysis conditions include construction method, nail and panel fixing method, backfill material compaction conditions, rainfall conditions. The classification according to the construction method of the precast panel retaining wall includes the top-down and bottom-up methods. The difference between the top-down and bottom-up methods is the presence or absence backfill material and the ground excavation method. The top-down method involves vertically excavating the ground and attaching the panel using mortar, but in the bottom-up method, the ground is vertically excavated and harden the backfill material. As a result of numerical analysis, the top-down method secured a higher safety factor in all cases except the rainfall conditions.

Numerical Study on Wave Run-up of a Circular Cylinder with Various Diffraction Parameters and Body Drafts

  • Jeong, Ho-Jin;Koo, Weoncheol;Kim, Sung-Jae
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.245-252
    • /
    • 2020
  • Wave run-up is an important phenomenon that should be considered in ocean structure design. In this study, the wave run-up of a surface-piercing circular cylinder was calculated in the time domain using the three-dimensional linear and fully nonlinear numerical wave tank (NWT) techniques. The NWT was based on the boundary element method and the mixed Eulerian and Lagrangian method. Stokes second-order waves were applied to evaluate the effect of the nonlinear waves on wave run-up, and an artificial damping zone was adopted to reduce the amount of reflected and re-reflected waves from the sidewall of the NWT. Parametric studies were conducted to determine the effect of wavelength, wave steepness, and the draft of the cylinder on the wave run-up of the cylinder. The maximum wave run-up value occurred at 0°, which was in front of the cylinder, and the minimum value occurred near the circumferential angle of 135°. As the diffraction parameter increased, the wave run-up increased up to 1.7 times the wave height. Furthermore, the wave run-up was 4% higher than the linear wave when the wave steepness was 1/35. In particular, the crest height of the wave run-up increased by 8%.

Strength buckling predictions of cold-formed steel built-up columns

  • Megnounif, A.;Djafour, M.;Belarbi, A.;Kerdal, D.
    • Structural Engineering and Mechanics
    • /
    • v.28 no.4
    • /
    • pp.443-460
    • /
    • 2008
  • The aim of this paper is to propose a design procedure for predicting the buckling strength of built-up, cold-formed steel columns based on the two well known methods; the effective width method and the Direct Strength Method. Several design approaches, based on different elastic buckling solutions, were considered in this investigation. Traditional hand methods, without interaction effects between the different modes, and a new numerical spline finite strip method were used to predict the buckling stresses. All of the proposed methods were compared with experimental data on plain and lipped, built-up columns. Results have shown that the effective width approaches are more accurate than the Direct Strength Method. However, both methods can be investigated using more experimental data to assess a practical design method for built-up columns.

Buckling Analysis of Built up Column with Stay Plates by the Generalized Differential Quadrature Method (GDQM에 의한 띠판을 갖는 조립 칼럼의 좌굴 해석)

  • 신영재;김재호;정인식
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.9
    • /
    • pp.462-474
    • /
    • 2001
  • In this paper, Generalized Differential Quadrature Method is applied to the buckling analysis of built-up columns without or with stay plates. numerical analysis using GDQM is carried out for various boundary conditions(simply supported conditions, fixed conditions, fixed-simply supported conditions), dimensionless stiffness parameter and dimensionless inertia moment parameter. The accuracy and convergence of solutions are compared with exact solutions of Gjelsvik to validate the results of GDQM. Results obtained by this method are as follows. 91) This method can yield the accurate numerical solutions using few grid points. (2) The buckling load of built-up column increases as the dimensionless stiffness parameter decreases. (3) The effects of boundary conditions on the buckling load are not considerable as the dimensionless stiffness parameter increases. (4) The buckling load of built-up column increases due to the stay plate.

  • PDF

The Effect of Warm-Up Method on Exercise Performance and Rate Pressure Product during Resistance Training

  • Hwanjong Jeong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.148-155
    • /
    • 2024
  • We are designed was to find an efficient warm-up method for resistance training for muscle hypertrophy, and 10 males with at least 3 years of resistance training experience were selected as subjects. The 75% 1RM was measured directly based on the pre-measured bench press 1RM. After that, the main experiment of 75% 1RM bench press according to the three warm-up methods was conducted one week apart, and all experiments were randomized and cross-over. Performance according to the warm-up method (3) was measured by total exercise volume, and physiological changes were determined by myocardial workload. All post-measurement data were analyzed using SPSS.22.0 and analyzed using repeated measures one-way ANOVA and contrast comparisons were made using the deviation method. The results showed that the method of gradually increasing the number of repetitions by performing the same intensity as the intensity of the main exercise in the form of muscle hypertrophy, but at submaximal repetitions, showed the highest performance.

Scale- Up of Water-Oil Hydrolysis System

  • Hur, Byung-Ki;Kim, Eun-Ki
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.6
    • /
    • pp.773-777
    • /
    • 1999
  • Scale-up experiments for hydrolysis of beef tallow, fat, and palm kernel with lipase derived from Candida cylindracea were carried out in 1-1, 100-1, and 10,000-1 reactors. The optimum agitation speed for the hydrolysis of the 1-1 reactor was investigated and found to be 350rpm, and this was a basis for the scale-up of agitation speed. The hydrolysis system in this work was the oil-water system in which the hydrolysis seems to process a heterogeneous reaction. An emulsion condition was the most important factor for determining the reaction rate of hydrolysis. Therefore, the scale-up of agitation speed was performed by using the power n = 1/3 in an equation of the rules of thumb method. The geometrical similarity for scaling-up turned out to be unsatisfactory in this study. Thus, the working volume per one agitator was used for the scale-up. In the case of scale-up from a 1-1 reactor to a 100-1 reactor, the hydrolysis of palm kernel was very much scaled-up by initiating the rules of thumb method. However, the hydrolysis of fat and beef tallow in a 100-1 reactor was a little higher than that of the 1-1 reactor because of the difference of geometrical similarity. The scale-up of hydrolysis from the 100-1 reactor to the 10,000-1 reactor was improved compared to that of the 1-1 to 100-1 reactor. The present results indicated that the scale-up of hydrolysis in the oil-water system by the rules of thumb method was more satisfactory under the condition of geometrical similarity. Even in the case where geometrical similarity was not satisfactory, the working volume per one agitator could be used for the scale-up of a heterogeneous enzyme reaction.

  • PDF