• Title/Summary/Keyword: Unsteady energy analysis

Search Result 117, Processing Time 0.031 seconds

Analysis of Unsteady Blade Forces in a Vertical-axis Small Wind Turbine (수직형 소형풍력터빈의 비정상 익력 평가)

  • LEE, SANG-MOON;KIM, CHUL-KYU;JEON, SEOK-YUN;ALI, SAJID;JANG, CHOON-MAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.2
    • /
    • pp.197-204
    • /
    • 2018
  • In the present study, unsteady flow analysis has been conducted to investigate the blade forces and wake flow around a hybrid street-lamp having a vertical-axis small wind turbine and a photovoltaic panel. Uniform velocities of 3, 5 and 7 m/s are applied as inlet boundary condition. Relatively large vortex shedding is formed at the wake region of the photovoltaic panel, which affects the increase of blade torque and wake flow downstream of the wind turbine. It is found that blade force has a good relation to the variation of the angle of attack with the rotation of turbine blades. Variations in the torque on the turbine blade over time create a cyclic fluctuation, which can be a source of turbine vibration and noise. Unsteady fluctuation of blade forces is also analyzed to understand the nature of the vibration of a small wind turbine over time. The detailed flow field inside the turbine blades is analyzed and discussed.

Performance Analysis of Floating Wave Energy Converter by Using CFD (CFD를 이용한 부양식 파력발전 장치의 성능해석)

  • CHOI, Yong-Seok;LIM, Tae-Woo;KIM, You-Taek
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.5
    • /
    • pp.1303-1309
    • /
    • 2015
  • The behavior and flow characteristics of the floating wave energy converter were analyzed by using CFD in this study. The average significant wave height was confirmed as 0.5~2.0m from the Korean coastal sea area. This study was carried out by selecting a range of 1.0~1.6m in the wave height to simulate the operations of realistic wave energy converter system. The principle of a piston wave maker was applied in order to produce periodic wave. The behavior of the wave energy converter and the state of the wave overtopping according to the generated periodic wave were confirmed through the unsteady three-dimensional flow analysis. It was found that the wave overtopping rate according to the generated periodic wave was in range of the 11.6~30.0 kg/s.

A Study on the Yearly Measurement and Numerical Analysis of Underground Temperature (년간 지중온도의 실측 및 수치해석에 관한 연구)

  • Shin, Y.H.;Tanshen, Md. Riyad;Chung, H.C.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.16 no.2
    • /
    • pp.30-35
    • /
    • 2012
  • The geothermal energy is one of the renewable energy sources which can contribute in accomplishing a vision and goal of the national plan on energy for a government suggestion. Especially, the geothermal energy is evaluated as the nearly unlimited resources. The yearly underground temperature distribution by depth is very important to the design of air-conditioning system which uses a geothermal energy. Furthermore, there has no data for comparisons to numerical analysis. In this study, the yearly underground temperature is measured under the depth of 2 m in Tongyeong, and these data are compared with numerical analysis results for checking the accuracy. The results showed that the experimental temperature and numerical results had a good agreements and these results will be utilized to predict a performance of air-conditioning system for using a geothermal energy.

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

Energy Performance Analysis Program with Heating methods of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방용 자동온도조절기의 난방방식에 따른 에너지성능 해석용 프로그램에 관한 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob;Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.381-386
    • /
    • 2008
  • In this study, the energy characteristic of automatic thermostatic valves according to each heating method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on heating method, valve's control method, outdoor air condition, supply heating water temperature, supply flow rate are performed to compare energy characteristic, respectively.

  • PDF

Study on the Flow Characteristics Inside a Metal DPF System (메탈 DPF 시스템 유동특성 연구)

  • Han, Cheolheui;Chon, Munsoo
    • Journal of Institute of Convergence Technology
    • /
    • v.3 no.1
    • /
    • pp.31-35
    • /
    • 2013
  • Unsteady fluid dynamics analysis of flow characteristics inside a Metal DPF system is done using a commercial CAE software, CFD-ACE+. The time profiles of both temperature and pressure of exhaust gas are given as initial conditions. It was found that the position of connecting pipes and the numbering of exhaust gases did not affect the flow uniformity. The presence of a DPF resulted in the significant flow nonuniformity effect on the flow characteristics at the inlet of the DPF. Present results can be applied to the selection of optimal geometry that produces uniform flow characteristics inside a DPF system.

  • PDF

Numerical Analysis for the Unsteady Laminar Flow and Heat Transfer Around a Circular Cylinder (원주 주위의 비정상 층류유동과 열전달에 대한 수치해석)

  • 조석호;남청도;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.64-72
    • /
    • 1991
  • The unsteady, two-dimensional laminar flow and heat transfer of an incompressible, constant-property fluid flowing around a circular cylinder are numerically analyzed. The Navier-Strokes equation and the energy equation are solved by the finite difference method. The range of the Reynolds number is 10 to 100 and the Prandtl number considered is 0.7. The contours of the flow pattern, equi-vorticity line and isotherm pattern around a circular cylinder are shown. Also, numerical solutions of the surface vorticity, pressure coefficient, drag coefficient, local Nusselt number and mean Nusselt number are obtained. The numerical results for the final time fo calculation are compared with the other available experimental and theoretical results for the steady state and are found to be in good agreement with them.

  • PDF

A Study on the 3-D Unsteady State Heat Transfer Coupled by Conductive Currents (전기장 변화에 따른 3차원 비정상 상태 열전달 연계 해석에 관한 연구)

  • Kwac, L.K.;Kim, H.G.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.29-34
    • /
    • 2008
  • A modeling technique for the 2-way coupling of heat transfer and conduction currents has been performed to inspire a combined analytical simulation. The 3-D finite element method is used to solve steady conduction currents and heat generation in an aluminum film deposited on a silicon substrate. The model investigates the temperature in the device after the current is applied. The conservation equation of energy, the Maxwell equations for conduction currents, the unsteady state heat transfer equation and the Fourier's law for heat transfer are implemented as a bidirectionally coupled problem. It is found that the strongly coupled temperature and time dependent heat equations give a reasonable results and an explicit solving technique.

Analysis of instantaneous friction in full-circumferentially grooved engine main bearings (원주방향 윤활홈을 갖는 엔진 주베어링의 연속 마찰 해석)

  • 전상명
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.4
    • /
    • pp.35-46
    • /
    • 1990
  • The instantaneous friction in main bearings of a single cylinder diesel engine was determined by measuring the instantaneous angular velocity, calculating the resulting forces acting on the bearings, and solving the unsteady Reynolds equation in combination with the mobility method. The considered system consists of only the crankshaft with flywheel and oil pump. The thermal effects were not considered because of the short testing time. The tests were conducted using an electric start motor. The results indicated that when the bearing is not near equilibrium for very small speeds, simple film lubrication theories are not accurate. The details of grooves and unsteady terms in the Reynolds equation cannot be ignored for increasing efficiency of instantaneous friction calculation of the engine bearings. The effects of speed on instantaneous friction and energy lost in friction were determined.

  • PDF

Numerical Analysis of Unsteady Thermo-Fluid Behavior for Launched Body using Chimera Mesh (키메라 격자를 이용한 발사체의 비정상 열유동해석)

  • Son, D.H.;Sohn, C.H.;Ha, J.H.
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1013-1018
    • /
    • 2010
  • This paper presents a numerical evaluation of the launch dynamics and thermo-fluid phenomena for gas generator launch eject system. The existing gas dynamic model for launching eject body used ideal gas and adiabatic assumption with empirical energy loss model. In present study, a turbulent Navier-Stokes solver with CHIMERA mesh is employed to predict the detail unsteady thermo-fluid dynamics for the launched body. The calculation results show that proper grid number is necessary for good agreement with experimental data. The important effects for accurate prediction are a gap distance and thermal boundary condition on the wall. The computational results show good agreement with experiment data.