• Title/Summary/Keyword: Unstable Flow

Search Result 399, Processing Time 0.025 seconds

Numerical simulation of diffusion in the stratified flow

  • Mizumoto N.;Kawamura T.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.255-256
    • /
    • 2003
  • Simulations of atmospheric diffusion process under stable and unstable conditions were carried out using both numerical and experimental methods. Results from the previous study show that numerical simulation using 3-dimensional incompressible Navier-Stokes equation and density deviation are in good agreement with typical plume pattern. In this study, we use experimental data of temperature and wind profile obtained from a thermally stratified wind tunnel as initial conditions for numerical simulation and compare the results.

  • PDF

A STUDY OF FLOW CHARACTERISTICS AND DESIGN VARIABLES IN AN LPG INJECTOR (LPG Injector 컷솔 유동 특성 및 설계 변수 연구)

  • Lee, Joon-Sik;Lim, Seol;Kim, Sang-Dug;Song, Dong-Joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.239-243
    • /
    • 2008
  • Fluid flow in LPG injector is delayed momently around nozzle and leaked accidentally, then engine operation becomes unstable. When attached cutsole injector that we can prevent fuel from leaking. Attaching additional devices cause loss of power and pressure. In this study, We has analyzed the performance of the LPG injector nozzle by changing cutsole geometry numerously by using Computational Fluid Dynamics.

  • PDF

A STUDY OF FLOW CHARACTERISTICS AND DESIGN VARIABLES IN AN LPG INJECTOR (LPG Injector 컷솔 유동 특성 및 설계 변수 연구)

  • Lee, Joon-Sik;Lim, Seol;Kim, Sang-Dug;Song, Dong-Joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.239-243
    • /
    • 2008
  • Fluid flow in LPG injector is delayed momently around nozzle and leaked accidentally, then engine operation becomes unstable. When attached cutsole injector that we can prevent fuel from leaking. Attaching additional devices cause loss of power and pressure. In this study, We has analyzed the performance of the LPG injector nozzle by changing cutsole geometry numerously by using Computational Fluid Dynamics.

  • PDF

Transient stability analysis of the Yongwol.Bupyong power system by electronic analog computer techniques (상이형전자계산기에 의한 영월.부평간 송전계통의 과도안전도 해석)

  • 한만춘
    • 전기의세계
    • /
    • v.15 no.1
    • /
    • pp.14-19
    • /
    • 1966
  • Transient stability analysis of Yongwol-Bupyong power system, which contains Yongwol steam power station, the largest one in Korea, was undertaken by using the Yonsei 101 Analog computer. The critical switching time and phase angle for the present 150MW power flow to be stable were found. And the transient stability power limit for the system was also found. It is concluded that the system becoms unstable if the power flow increases much more than 151MW.

  • PDF

Effects of Vibratory Stimulus on Postural Balance Control during Standing on a Stable and an Unstable Support (안정판과 불안정판에서 자세 균형 조절에 대한 진동자극의 영향)

  • Yu, Mi;Eun, Hey-In;Kim, Dong-Wook;Kwon, Tae-Kyu;Kim, Nam-Gyun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.647-656
    • /
    • 2007
  • The purpose of this study was to analyze the effects of vibratory stimulus as somatosensory inputs on the postural control in human standing. To study these effects, the center of pressure(COP) was observed while subjects were standing on a stable and an unstable support with co-stimulated mechanical vibrations to flexor ankle muscles(tibialis anterior tendon, achilles tendon) and two plantar zones on both foot. The COP sway measurement was repeated twice in four conditions: (1) with visual cue and vibration, (2) without visual cue and vibration, (3) with visual cue and without vibration, (4) without visual cue and with vibration. The calculated parameters were the COP sway area and the distance, the median frequency and the spectral energy of COP sway in three intervals $0.1{\sim}0.3,\;0.3{\sim}1,\;1{\sim}3Hz$. The results showed that vibratory stimulus affect postural stability. The reduction rate of the COP sway with vibratory stimulus were higher on the unstable support because the effect of postural stability increases when afferent nervous flow is more activated by vibration on unstable support. If unclear visual or vibratory information is received, one type of information is compared with the other type of sensory information. Then the input balance between visual and vibratory information is corrected to maintain postural stability. These findings are important for the rehabilitation system of postural balance control and the use of vibratory information.

Analysis of the Stability of HLA-A2 Molecules Expressed on the Cell Surface

  • Lim, Jong-Seok;Lee, Ki-Young;Lee, Hee-Gu;Kim, Ik-Hwan;Lee, Chong-Kil;Han, Seong-Sun;Kim, Kil-Hyoun
    • BMB Reports
    • /
    • v.29 no.4
    • /
    • pp.286-293
    • /
    • 1996
  • Association of antigenic peptide with class I MHC is believed to be crucial for maintaining stable conformation of class I molecules. T2 cells that are defective in TAP gene function mainly express class I molecules with an unstable conformation due to little or no association with antigenic peptides, whereas T1 cells that are normal in TAP gene function mainly express the stable form of class I molecules. In this work, attempts were made to determine the molecular stability of stable and unstable class I molecules. Dissociation of HLA-A2 molecules on T1 and T2 cells was monitored by flow cytometry using anti-HLA-A2 antibody after the cells were treated with brefeldin A to shut down the transport of newly-assembled HLA-A2. Estimated dissociation rate constants for the stable and unstable forms of HLA-A2 were 0.076 $h^{-1}$ and 0.66 $h^{-1}$, respectively. It appeared that both T1 and T2 cells express stable and unstable class I complex, but with different ratios of the two forms. Furthermore, $interferon-{\gamma}$ treatment of T1 cells appeared to induce the expression of both the stable and unstable class I molecules. These results demonstrate that class I MHC molecules can be divided into two groups in terms of structural stability and that they exist on the cell surface in both forms in a certain ratio.

  • PDF

Effects of Respiratory Muscle Strengthening Training on the Pulmonary Function in Chronic Stroke Patients on an Unstable Support Surface (불안정한 지지면에서의 호흡근 강화훈련이 만성 뇌졸중 환자의 폐기능에 미치는 영향)

  • Lee, Myoung-Ho;Kim, Myoung-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.2
    • /
    • pp.75-82
    • /
    • 2022
  • PURPOSE: This study examined the correlation between the pulmonary function and respiratory muscle strengthening training on an unstable support surface and a stable support surface in stroke patients. METHODS: The study subjects were 22 stroke patients undergoing central nervous system developmental rehabilitation treatment. After excluding six dropouts, eight people in the experimental group and eight people in the control groups were classified by random sampling. Both groups performed central nervous system developmental rehabilitation therapy and were provided a 10-minute break. The experimental group was provided with an unstable support surface using Togu, and the control group was trained to strengthen the respiratory muscle in a stable support surface. Respiratory muscle strengthening training was conducted three times per week for 20 minutes. Before and after each group of experiments, a nonparametric test Wilcoxon signed rank test, and a Mann Whitney U-test analysis were used to analyze the variations between the two groups. All statistical significance levels (α) were set at 0.05. RESULTS: Both groups showed increases in the pulmonary function but showed significant differences only in the experimental group. There was a significant difference in the peak expiratory flow between the two groups. CONCLUSION: Central nervous system development rehabilitation treatment for patients with an impaired nervous system and respiratory muscle strengthening training on unstable support surfaces are effective in improving the pulmonary function of stroke patients. Therefore, they are expected to be applied to physical therapy programs to help various functional activities.

Numerical Analysis of the Three-Dimensional Wake Flow and Acoustic Field around a Circular Cylinder

  • Kim, Tae-Su;Kim, Jae-Soo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.11 no.4
    • /
    • pp.319-325
    • /
    • 2010
  • For decades, researchers have rigorously studied the characteristics of flow traveling around blunt objects in order to gain greater understanding of the flow around aircraft, vehicles or vessels. Many different types of flow exist, such as boundary layer flow, flow separation, laminar and turbulent flow, vortex and vortex shedding; such types are especially observed around circular cylinders. Vortex shedding around a circular cylinder exhibits a two-dimensional flow structure possessing a Reynolds number within the range of 47 and 180. As the Reynolds number increases, the Karman vortex changes into a three-dimensional flow structure. In this paper, a numerical analysis was performed examining the flow and aero-acoustic field characteristics around a circular cylinder using an optimized high-order compact scheme, which is a high order scheme. The analysis was conducted with a Reynolds number ranging between 300 and 1,000, which belongs to B-mode flow around a circular cylinder. For a B-mode Reynolds number, a proper spanwise length is analyzed in order to obtain the characteristics of three-dimensional flow. The numerical results of the Strouhal number as well as the lift and drag coefficients according to Reynolds numbers are coincident with the other experimental results. Basic research has been conducted studying the effects an unstable three-dimensional wake flow on an aero-acoustic field.

Development of a Flow Compensating Boom Sprayer for the Speed Variation (주행속도 보상형 붐방제기의 개발)

  • 구영모;정재은
    • Journal of Biosystems Engineering
    • /
    • v.23 no.3
    • /
    • pp.211-218
    • /
    • 1998
  • A variable flow-controlled boom sprayer was developed and evaluated. Field tests were conducted to evaluate the adoptability of the sprayerr with optimal conditions. Negative response time was obtained from the field test because pump and PTO were interlocked with the speed of sprayer. Another reason for the negative value was due to the definition of the response time. With constant on-time control, the system was unstable at the conditions of small tolerance and long control interval. The performances of the spray system were stable and accurate. The stable and synchronous responses were achieved with a variable on-time control. The flow control system with an optimal condition (1.0 sec of control interval, 2 of damping ratio, 1% of tolerance) provided the proper performance for uniform spraying. A standard operating procedure of the flow compensating boom sprayer for the ground speed variation was presented and recommended.

  • PDF

A Experimental Study on the Uneven Flow Distribution in the Windbox of an Oil-Fired Boiler (유류 연소 발전용 보일러에서 공기 공급 계통의 불균일성에 관한 실험적 연구)

  • Go, Young-Gun;Kim, Young-Bong;Choi, Sang-Min;Kim, Young-Zoo
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.199-206
    • /
    • 2004
  • In the multi-burner power plant, uneven supplies of combustion air to multi-burner are induced by unbalanced flow distribution in the windbox. These flow patterns tend to make flame unstable, increase the formation of pollutants and lower the overall combustion efficiency. To prevent these disadvantages, flow patterns in the windbox should be investigated and made to be distributed uniformly, In this study, scaled windbox model was used for tests and measured the velocities at the exit of the each burner and compared those with the CFD results.

  • PDF