• 제목/요약/키워드: Unseparated flow

검색결과 8건 처리시간 0.022초

개구부에 삽입한 수직평판이 헬륨.공기치환류에 미치는 영향 (Effect of Partition within Opening on Helium-Air Exchange Flow)

  • Tae-il Kang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.797-805
    • /
    • 2003
  • This paper describes experimental investigations of helium-air exchange flow through single opening and partitioned opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a small opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with the opening, for partition ratios H_p/H$_1$$ in the range 0 to 1. where H_p$ and H$_1$ are partition length and height of the opening. respectively. In the case of H_p/H$_1$$ of 0, flow passages of upward flow of the helium and downward flow of the air within the opening are unseparated (bidirectional), and the two flows interfere within the opening. The unseparated flow increases strength of flow resistance and therefore, the exchange flow rate is minimum through range of the partition ratios. Two flow zones, i.e., separated (unidirectional) flow zone and unseparated (bidirectional) flow zone, exist with increasing the partition length. The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at H_p/H$_1$$ of 1. As a result of comparison of the exchange flow rates by changing the partition ratio, the fluids Interference in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

개구부 삽입부의 길이가 헬륨 및 공기의 치환류에 미치는 영향 (Effect of Opening Partition Length on Helium-Air Exchange Flow)

  • 강태일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.192-200
    • /
    • 1999
  • This paper describes experimental investigations of helium-air exchange flow through parti-tioned opening. Such exchange flow may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with partitioned opening for parti-tion rations $H_p/H_1$ in the range 0 to 1 where $H_p$ and $H_1$ are partition length and height of the open-ing respecticely. In the case of $H_p/H_1$ of 0 flow passages of upward flow of the helium and down-ward flow of the air within the opening are unseparated (bidirectional) and the two flows interact exchange flow rate is minimum through range of the partition ratios, Two flow zones i.e. separat-ed(unidirectional)flow zone and unseparated(bidirectional) flow zone exist with increasing the partition. length, The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at $H_p/H_1$ of 1. As a result fo comparison of the exchange flow rates by changing the partition ration the fluids interaction in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

  • PDF

수직평판을 삽입한 개구부의 헬륨 및 공기 치환류 (Helium-Air Exchange Flow Through Openings with Vertical Partitions)

  • 강태일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.79-87
    • /
    • 2000
  • This paper describes experimental investigations of helium-air exchange flow through openings with vertical partitions. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. Exchange flow rates are investigated experimentally by using partitioned opening and opening with extended partition to assess fluids interference of the exchange flow at the stand pipe rupture accident. A tests vessel with the two types of opening on top of test cylinder is used in the experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Amplitude and progress of interference fringes of the flows are observed and used as a support in comparison with the exchange flow rates. Flow passages of upward flow of the helium and downward flow of the air for both two types of the opening are separated by inserted partition within the opening, but in the case of partitioned opening, unseparated flow is formed at the opening entrance and the two flows interface. The exchange flow rate for the partitioned opening is not greater than that of the opening with extended partition because of the fluids interference at the entrance of opening. Finally, the fluids interference at the opening entrance is found to be one of important factors on the helium-air exchange flow rate.

  • PDF

시간 전진법을 이용한 난류 경계층 유동의 해석 (ANALYSIS OF TURBULENT BOUNDARY LAYER FLOWS USING A TIME MARCHING METHOD)

  • 공효준;이승수
    • 한국전산유체공학회지
    • /
    • 제20권1호
    • /
    • pp.32-38
    • /
    • 2015
  • A 3-dimensional compressible turbulent boundary layer solver has been developed. A time marching method is used to integrate the turbulent boundary layer equations. While the direct integration of the boundary layer equations is performed for unseparated flow regions, the inverse integration is performed for separated flow regions. The program is verified for flows that have analytical solutions or other numerical results. The solver will be merged with an Euler solver for viscous-inviscid interaction.

압축성 유동을 위한 $k-{\omega}$ 난류방정식의 수렴성 연구 (Convergence Study of $k-{\omega}$ Turbulence Equations for Compressible Flows)

  • 박수형;성춘호;권장혁;이승수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.31-34
    • /
    • 2002
  • An efficient implicit multigrid method is presented for the Navier-Stokes and $k-{\omega}$ turbulence equations. Freezing and limiting strategies are applied to improve the robustness and convergence of the multigrid method. The eddy viscosity and strongly nonlinear production terms of turbulence are frozen in the coarser grids by passing down the values without update of them. The turbulence equations together with the Navier-Stokes equations, however, are consecutively solved on the coarser grids in a loosely coupled fashion. A simple limit for k is also introduced to circumvent slow-down of convergence. Numerical results for the unseparated and separated transonic airfoil flows show that all computations converge well without any robustness problem and the computing time is reduced to a factor of about 3 by the present multigrid method.

  • PDF

지하철 역사내 동선 분리 시스템을 활용한 보행편의 및 이동성 증진 (Improvement of Pedestrian Convenience and Mobility by Applying the Walking Guidance System in Subway Stations)

  • 이주용;김태완;유소영
    • 대한교통학회지
    • /
    • 제33권2호
    • /
    • pp.204-213
    • /
    • 2015
  • 지하철 역사 공간 내 보행교통류의 혼잡 상황은 역사의 이용효율을 저해시킨다. 특히 방향별 동선의 미분리로 인한 보행자간 상충은 보행자의 이동저항을 증가시키며 통행시간과 안전사고에 부정적인 영향을 끼치게 된다. 본 연구에서는 미시적 움직임에 기반한 양방향 보행교통류의 통행 특성을 분석하였으며, 동선 분리로 인한 운영상의 효과를 분석하는 모형을 개발하였다. 이산요소법에 따라 역사 공간을 2차원 grid 구조로 해석하였으며, 각 grid에 존재하는 cell 별로 보행자의 움직임이 이루어진다고 보았다. 그 결과 양방향 보행교통류가 상충하는 상황에서는 동선을 분리시키고, 우측통행을 유도하여 보행자들의 진행 방향을 정돈시키는 경우가 가장 효율이 좋은 것으로 분석되었다. 이에, 동선 분리 시스템을 적용하여 보행편의 및 이동성을 증진시키기 위한 시사점을 제시하고자 한다.

Percoll 분리된 미니돼지 정액의 체외 수정 능력에 있어서 동결보존액의 영향 (Effects of Cryo-extenders for Spermatozoa Sorted by Percoll on In Vitro Fertility of in Miniature Pigs)

  • 이상희;유한준;이용승;정희태;양부근;김대영;박춘근
    • Reproductive and Developmental Biology
    • /
    • 제35권1호
    • /
    • pp.85-91
    • /
    • 2011
  • The objective of this study was to evaluated the efficiency on sperm cryosurvival and ability of in vitro fertilization using Triladyl and Lactose Egg-Yolk(LEY) as extenders for cryopreservation of separated sperm by 65% percoll in miniature pig. Sperm viability was measured with SYBR-14/PI double stained sperm by flow cytometry. Ability on embryo cleavage rate and blastocyst development were observed by in vitro fertilization after frozen-thawing of sperm separated by 65% percoll. The experimental groups were designed that separated sperm by 65% percoll with Triladyl (ST) or LEY(SL) and unseparated sperm with Triladyl(UT) or LEY(UL) for cryopreservation. As a results, the viability was significantly(p<0.05) higher in ST(55.1%), SL(63.1%), UL(58.8%) than UT(38.2%) group. Sperm viability in SL(63.1%) group was significantly(p<0.05) higher than other experimental groups. On the other hand, embryo cleavage rate was significantly(p<0.05) higher in ST(79.1%), SL(83.2) than UT(74.1) and UL(75.7%) groups at 96h after in vitro fertilization. Blastocyst development was also significantly(p<0.05) higher in ST(21.5%), SL(20.9%) than UT(17.0%) and UL(18.8%) groups. In conclusion, cryopreservation of miniature boar sperm separated by 65% percoll were beneficial to viability and capacity on in vitro fertilization.

항산화 효소가 첨가된 Percoll에 의해 분리한 돼지 정액의 동결-융해 능력 (Cryo-Ability of Boar Sperm sorted by Percoll Containing of Antioxidative Enzyme)

  • 이경진;이상희;주선호;김유진;양진우;이연주;황보용;이승형;이승태;이은송;박춘근
    • 한국수정란이식학회지
    • /
    • 제30권3호
    • /
    • pp.121-128
    • /
    • 2015
  • The objective of this study was to evaluate the efficiency of sperm cryosurvival in boar sperm separated by Percoll containing antioxidant enzymes. The boar semen was collected into a pre-warmed ($37^{\circ}C$) thermos bottle by gloved-hand method and was separated by 65% Percoll with superoxide dismutase (SOD), catalase (CAT) and glutathione (GSH) before freezing. The frozen sperm was thawed at $38.5^{\circ}C$ for 45 sec in water-bath for sperm characteristic analysis. The sperm were estimated with SYBR14/PI double staining for viability, FITC-PNA/PI double staining for acrosome reaction, Rhodamine123/PI double staining for mitochondrial integrity and were analyzed using flow cytometry. In results, sperm viability, acrosome reaction and mitochondrial integrity were improved in separated sperm groups compared with unseparated sperm by Percoll (UP) group. Especially, viability was significantly higher in sperm separated by Percoll containing 400 IU CAT group compared with other groups (P<0.05). And acrosome reaction was decreased in sperm separated by Percoll with 300 IU SOD, 400 IU CAT and 0.5 mM GSH groups compared with other groups, however, there were no significantly difference mitochondrial integrity among sperm separated by Percoll with antioxidant enzymes. In conclusion, we suggest that use of Percoll containing antioxidant enzymes for sperm separation will be beneficial for sperm cryopreservation in pigs.