• Title/Summary/Keyword: University's Image

Search Result 7,172, Processing Time 0.041 seconds

Suggestions for Using Historical and Cultural Resources in Uiseong : Focusing on the Gilt-bronze Crown and the Earthenware of Jomunguk (의성 지역 역사문화자원 활용을 위한 제안 : 조문국 금동관과 토기를 중심으로)

  • Lee, Eunjoo;Kim, Migyung;Kim, Youngsun
    • 지역과문화
    • /
    • v.6 no.3
    • /
    • pp.79-105
    • /
    • 2019
  • In the Geumseongsan Tumulus of the Uiseong area where the Jomunguk was existed in the Three Han Period, many relics such as metal craft ornaments and Uiseong-style earthernware were excavated. However, it is hard to find cases where the excavated relics were used to develop cultural products. In this study, symbolic relics which can express the culture of Uiseong Jomunguk were selected from excavated relics. Then, the basic design that can be applied to various cultural products were derived from symbolic relics. In order to select symbolic relics, the formative characteristics of the metal craft relics excavated from the Tablili Tumulus and the Dali Tumulus were examined. As a result, a gilt-bronze crown excavated from the Tablili Tumulus was selected as a symbolic relics. And then the basic desin was derived from the gilt-bronze crown. The basic design is expressed in the form of birds based on the bird's feather shape at the edge of the standing ornaments and the record of the Bongdae(鳳臺), the phoenix's habitat. And the application design that changed the expression of the birds' face was presented. The earthenware excavated from the Uiseong area was designed as a soil pot and applied various indoor air purification plants. The result of this study, which reinterprets and reconstructs the historical and cultural resources of the region in accordance with the modern sense, can be used as useful data for the development of cultural products of Jomunguk. Furthermore, if the design derived from the Jomunguk relics is used as a representative symbol of the area, it will be possible to derive an image of a differentiated region from other regions. Finally, it is expected that the result of this study will be a chance to re-evaluate the value of the historical and cultural resources in the region.

The Effects of the Perceived Motivation Type toward Corporate Social Responsibility Activities on Customer Loyalty (기업사회책임활동적인지인지동기류형대고객충성도적영향(企业社会责任活动的认知认知动机类型对顾客忠诚度的影响))

  • Kim, Kyung-Jin;Park, Jong-Chul
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.3
    • /
    • pp.5-16
    • /
    • 2009
  • Corporate social responsibility (CSR) activities have been shown to be potential factors that can improve corporate image and increase the ability of corporations to compete. However, most previous studies related to CSR activities investigated how these activities influence product and corporate evaluation, as well as corporate image. In addition, some researchers treated consumers' perceptions of corporate motives as moderator variables in evaluating the relationship between corporate social responsibilities and consumer response. However, motive-based theories have some weaknesses. Corporate social responsibility activities cause two motives(egoistic vs. altruistic) for consumers, but recently, Vlachos et al. (2008) argued that these motives should be segmented. Thus, it is possible to transform the original theory into a modified theory model (persuasion knowledge model, PKM). Vlachos et al. (2008) segmented corporate social responsibility motives into four types and compared the effects of these motives on customer loyalty. Prior studies have proved that CSR activities with positive motives have positive influences on customer loyalty. However, the psychological reasons underlying this finding have not been determined empirically. Thus, the objectives of this research are twofold. First, we attempt to determine why most customers favor companies that they feel have positive motives for their corporate social responsibility activities. Second, we attempt to measure the effects of consumers' reciprocity when society benefits from corporate social responsibility activities. The following research hypotheses are constructed. H1: Values-driven motives for corporate social responsibility activities have a positive influence on the perceived reciprocity. H2: Stakeholder-driven motives for corporate social responsibility activities have a negative influence on the perceived reciprocity. H3: Egoistic-driven motives for corporate social responsibility activities have a negative influence on perceived reciprocity. H4: Strategic-driven motives for corporate social responsibility activities have a negative influence on perceived reciprocity. H5: Perceived reciprocity for corporate social responsibility activities has a positive influence on consumer loyalty. A single company is selected as a research subject to understand how the motives behind corporate social responsibility influence consumers' perceived reciprocity and customer loyalty. A total sample of 200 respondents was selected for a pilot test. In addition, to ensure a consistent response, we ensured that the respondents were older than 20 years of age. The surveys of 172 respondents (males-82, females-90) were analyzed after 28 invalid questionnaires were excluded. Based on our cutoff criteria, the model fit the data reasonably well. Values-driven motives for corporate social responsibility activities had a positive effect on perceived reciprocity (t = 6.75, p < .001), supporting H1. Morales (2005) also found that consumers appreciate a company's social responsibility efforts and the benefits provided by these efforts to society. Stakeholder-driven motives for corporate social responsibility activities did not affect perceived reciprocity (t = -.049, p > .05). Thus, H2 was rejected. Egoistic-driven motives (t = .3.11, p < .05) and strategic-driven (t = -4.65, p < .05) motives had a negative influence on perceived reciprocity, supporting H3 and H4, respectively. Furthermore, perceived reciprocity had a positive influence on consumer loyalty (t = 4.24, p < .05), supporting H5. Thus, compared with the general public, undergraduate students appear to be more influenced by egoistic-driven motives. We draw the following conclusions from our research findings. First, value-driven attributions have a positive influence on perceived reciprocity. However, stakeholder-driven attributions have no significant effects on perceived reciprocity. Moreover, both egoistic-driven attributions and strategic-driven attributions have a negative influence on perceived reciprocity. Second, when corporate social responsibility activities align with consumers' reciprocity, the efforts directed towards social responsibility activities have a positive influence on customer loyalty. In this study, we examine whether the type of motivation affects consumer responses to CSR, and in particular, we evaluate how CSR motives can influence a key internal factor (perceived reciprocity) and behavioral consumer outcome (customer loyalty). We demonstrate that perceived reciprocity plays a mediating role in the relationship between CSR motivation and customer loyalty. Our study extends the research on consumer CSR-inferred motivations, positing them as a direct indicator of consumer responses. Furthermore, we convincingly identify perceived reciprocity as a sub-process mediating the effect of CSR attributions on customer loyalty. Future research investigating the ultimate behavior and financial impact of CSR should consider that the impacts of CSR also stem from perceived reciprocity. The results of this study also have important managerial implications. First, the central role that reciprocity plays indicates that managers should routinely measure how much their socially responsible actions create perceived reciprocity. Second, understanding how consumers' perceptions of CSR corporate motives relate to perceived reciprocity and customer loyalty can help managers to monitor and enhance these consumer outcomes through marketing initiatives and management of CSR-induced attribution processes. The results of this study will help corporations to understand the relative importance of the four different motivations types in influencing perceived reciprocity.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

The Evaluation of TrueX Reconstruction Method in Low Dose (저선량에서의 TrueX 재구성 방법에 의한 유용성 평가)

  • Oh, Se-Moon;Kim, Kye-Hwan;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • Purpose: Recently in diagnostics area PET/CT is using a variety of areas including oncology, as well as in cardiology, neurology, etc. While increasing in the importance of PET/CT, there are various researches in the image quality related to reconstruction method. We compared and tested Iterative 2D Reconstruction Method with True X Reconstruction method by Siemens through phantom experiment, so we can see increasing of clinical usefulness of PET/CT. Materials and Methods: We measured contrast ratio and FWHM due to evaluating images on dose and experiment using Biograph 40 True Point PET/CT (Siemens, Germany). Getting a result of contrast ratio and FWHM, we used NEMA IEC PET body phantom (Data Spectrum Corp.) and capillary tube. We used the current TrueX and the previous Iterative 2D algorithm for all images which have 10 minutes long. Also, a clinical suitability of parameter for Iterative 2D and a recommended parameter by Siemens for True X are applied to the experiment. Results: We tested FWHM using capillary tube. As a result, TrueX was less than Iterative 2D. Also, the differences of FWHM get bigger in low dose. On the other hand, we tested contrasts ratio using NEMA IEC PET body phantom. As a result, TrueX was better aspect than Iterative 2D. However, there was no difference in dose. Conclusion: In this experiment, TrueX get higher results of contrast ratio and spatial resolution than Itertive 2D through experiment. Also, in the reconstruction result through TrueX, TrueX had better aspect of resolution than Iterative 2D in low dose. However, contrast ratio had no specific difference. In other words, TrueX reconstruction method in PET/CT had higher clinical value in use because TrueX can reduce exposure of patient and had a better quality of screen.

  • PDF

The Relationship among Country of Origin, Brand Equity and Brand Loyalty: Comparison among USA, China and Korea (원산지효과, 상표자산 및 상표충성 간의 관계에 관한 연구: 미국, 중국, 한국의 비교분석)

  • Ko, Eun-Ju;Kim, Kyung-Hoon;Kim, Sook-Hyun;Li, Guo-Feng;Zou, Peng;Zhang, Hao
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.1
    • /
    • pp.47-58
    • /
    • 2009
  • The marketing environment has become competitive to an extent that requires firms to target their products at markets that span national boundaries. However, competitive clout cannot be achieved in global consumer markets unless firms thoroughly understand and adequately respond to the core values and needs of those consumers. Brand equity is one of the most important assets to a company. Especially in sportswear markets, brand equity is the crucial value added to a product by its brand name. Factors such as country of origin also influence customer's attitude towards brand equity. Therefore, this paper discusses the relationship between country of origin effect and brand equity, and how they influence consumers' loyalty for respective brands. This paper focused on the sports shoes market, because it is an increasing area of opportunity for world manufacturers. The objectives of this study were the following. (1) Test the effect of country of origin on brand equity. (2) Test how brand equity influences consumers' brand loyalty. (3) Find whether there are differences in the effects of country of origin and brand equity among the three countries. (4) Find whether there are differences in the effects of country of origin and brand equity among the different lifestyles. Based on the review of literature results, the hypotheses are concluded as the following: H1-a: Country image has positive influence on country of origin. H1-b: Product perception has positive influence on country of origin. H2-a: Perceived quality has positive effect on brand equity. H2-b: Perceived price has positive effect on brand equity. H3: Country of origin has positive effect on brand equity. H4: Brand equity has a positive impact on brand loyalty. Research model was constructed (see Fig. 1). After data analysis, the following results were concluded: sports shoes purchase behavior showed significant differences among Korean, Chinese, and American consumers for favorite brand, purchased brand, purchased place, information usage, and favorite sports games. The results of this study also extend the research of the relationship among country of origin, brand equity and brand loyalty to the sports shoes market. Brand equity was proven to have a significant relationship with brand loyalty for all countries. The factors which can influence brand equity are different for different countries. The third finding of this paper is that we identified different three lifestyles, adventurer, follower, and laggard, for Korean, Chinese and American consumers. Without the nationality boundary, seeing the emergence of a new group of consumers who have similar preferences and buy similar brands is more important. All of the consumers consider brand equity to keep their brand loyalty. Perceived price is the only factor which can influence brand equity for adventurers; brand is more important for them. The laggards were not influenced by any factor. All of the factors expect perceived price are important for the followers. Marketing managers should consider brand equity when introducing their brand into a new market. Also localization is the basic strategy that all the sports shoes companies should understand. But as a global brand, understanding the same characteristics for each country is more important to build global strategy.

  • PDF

The Relationship Analysis between the Epicenter and Lineaments in the Odaesan Area using Satellite Images and Shaded Relief Maps (위성영상과 음영기복도를 이용한 오대산 지역 진앙의 위치와 선구조선의 관계 분석)

  • CHA, Sung-Eun;CHI, Kwang-Hoon;JO, Hyun-Woo;KIM, Eun-Ji;LEE, Woo-Kyun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.3
    • /
    • pp.61-74
    • /
    • 2016
  • The purpose of this paper is to analyze the relationship between the location of the epicenter of a medium-sized earthquake(magnitude 4.8) that occurred on January 20, 2007 in the Odaesan area with lineament features using a shaded relief map(1/25,000 scale) and satellite images from LANDSAT-8 and KOMPSAT-2. Previous studies have analyzed lineament features in tectonic settings primarily by examining two-dimensional satellite images and shaded relief maps. These methods, however, limit the application of the visual interpretation of relief features long considered as the major component of lineament extraction. To overcome some existing limitations of two-dimensional images, this study examined three-dimensional images, produced from a Digital Elevation Model and drainage network map, for lineament extraction. This approach reduces mapping errors introduced by visual interpretation. In addition, spline interpolation was conducted to produce density maps of lineament frequency, intersection, and length required to estimate the density of lineament at the epicenter of the earthquake. An algorithm was developed to compute the Value of the Relative Density(VRD) representing the relative density of lineament from the map. The VRD is the lineament density of each map grid divided by the maximum density value from the map. As such, it is a quantified value that indicates the concentration level of the lineament density across the area impacted by the earthquake. Using this algorithm, the VRD calculated at the earthquake epicenter using the lineament's frequency, intersection, and length density maps ranged from approximately 0.60(min) to 0.90(max). However, because there were differences in mapped images such as those for solar altitude and azimuth, the mean of VRD was used rather than those categorized by the images. The results show that the average frequency of VRD was approximately 0.85, which was 21% higher than the intersection and length of VRD, demonstrating the close relationship that exists between lineament and the epicenter. Therefore, it is concluded that the density map analysis described in this study, based on lineament extraction, is valid and can be used as a primary data analysis tool for earthquake research in the future.

Current Status and Improvements of Transfered PET/CT Data from Other Hospitals (외부 반출 PET/CT 영상 현황 및 개선점)

  • Kim, Gye-Hwan;Choi, Hyeon-Joon;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.38-40
    • /
    • 2010
  • Purpose: This study was performed to find the current problems of PET/CT data from other hospitals. Materials and Methods: The subjects were acquired from 64 hospitals referred to our department for image interpretation. The formats and contents of PET/CT data were reviewed and the phone questionnaire survey about these were performed. Results: PET/CT data from 39 of 64 hospitals (61%) included all transaxial CT and PET images with DICOM (Digital Imaging Communications in Medicine) standard format which were required for authentic interpretation. PET/CT data from the others included only secondary capture images or fusion PET/CT images. Conclusion: The majority of hospitals provided limited PET/CT data which could be inadequate for accurate interpretation and clinical decision making. It is necessary to standardize the format of PET/CT data to transfer including all transaxial CT and PET images with DICOM standard format.

  • PDF

Method to Reduce the Activity Loss and Pain when Injecting 18F-Florbetaben (18F-Florbetaben 주사 시 Activity 손실과 통증 감소를 위한 방법)

  • Kwon, Hyeong Jin;Choi, Jin Wook;Lee, Hyeong Jin;Woo, Jae Ryong;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.42-45
    • /
    • 2016
  • Purpose Neuracep is used to other diagnostic evaluations of the brain to estimate beta-amyloid neuritic plaque density in adult patients with cognitive impairment and inspected cognitive impairment. $^{18}F-Florbetaben$ specially has moderate lipophilicity and property of the added ethanol. It is the subject of interest of the patient pain and residual activity after injecting. Our study is effective injection method of the radiopharmaceutical and patient care. So it is for the highest quality image. Materials and Methods Patients were targeted 70 subjects, it was injected mean $259{\pm}74MBq$ to the patients ($^{18}F-FDG$: 20 subjects, $^{18}F-FP-CIT$: 20 subjects, $^{18}F-Florbetaben$: 30 subjects). After injection (reflusing 2 times, reflusing 3 times) using a 3-way set, it measured the residual activity. When injecting $^{18}F-Florbetaben$, we evaluated the effective injection methods(3-way set method and heparin cap method). The average residual activity after the injection was compared using a statistical analysis of SPSS 12.0(ANOVA, t-test analysis). Also, elemental analysis was performed on $^{18}F-Florbetaben$ by GC (Gas Chromatography). Results When reflusing 2 times measured residual activity as follows ($^{18}F-FDG$: 1.48 MBq, $^{18}F-FP-CIT$: 7.4 MBq, $^{18}F-Florbetaben$: 32.6 MBq). And when reflusing 3 times measured residual activity as follows ($^{18}F-FDG$: 1.85 MBq, $^{18}F-FP-CIT$: 3.7 MBq, $^{18}F-Florbetaben$: 36.3 MBq). There was a significant difference when reflusing 2 times(P < 0.05) and reflusing 3 times (P < 0.05). But when reflusing 3 times, there was no significant difference relation FDG and FP-CIT (P > 0.05). $^{18}F-Florbetaben$ Residual activity according to the injection method was a significant difference (P < 0.05). GC analysis results were measured ethanol: 207665 ppm and acceton: 377.4 ppm. Conclusion $^{18}F-Florbetaben$ was high residual activity compared to FDG and FP-CIT. Heparin cap method was effective when $^{18}F-Florbetaben$ was injected. $^{18}F-Florbetaben's$ ethanol component analysis was highly measured. So it is recommended that inject to 6 sec/ml or more in order to reduce the pain.

  • PDF

The Evaluation of Lateral Scatter Ray of Gamma Camera (Gamma Camera에 있어 측면 선란선의 영향에 대한 평가)

  • Kim, Jae-Il;Lee, Eun-Byeol;Cho, Seong-Wook;Noh, Kyeong-Woon;Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.46-50
    • /
    • 2018
  • Purpose Generally, a collimator that installed in front of detector set a direction of gamma ray and remove a scatter ray. By the way, a lateral or oblique scatter ray is detected into crystal through collimator. At this study, we will evaluate a mount of count and spectrums of lateral scatter ray. Materials and Methods We used the SKY LITE (philips, netherlands) as a gamma camera, and $^{99m}Tc$, 1.11 GBq point source as a phantom. we put this point source at backside 50 cm of detector. After acquiring this for 1 min, we turned a detector next 10 degrees. Likely this, we acquired images at every 10 degrees from $0^{\circ}$ to $360^{\circ}$, analyzed images and spectrums. In case of patient study, we choose a 3 phase bone scan patient who had a hand disease, because scatter rays from body would detect on crystal. After acquiring blood flow and blood pool images, we analyzed images and spectrums. Additional, we put a lead gown on patient's hand, body. And then we compared and evaluated 3 type blood pool images (non lead gown, lead gown on a hand and on body). Results In case of phantom study, scatter ray counts at backside ($270^{\circ}-90^{\circ}$) are same with a background count. By the way, counts of scatter ray of oblique side ($0^{\circ}-50^{\circ}$, $220^{\circ}-270^{\circ}$) are 100-600 cps, furthermore, counts at frontside are over 4 Mcps. In case of patient study, a counts of hand blood pool scan are 1510 cps. But counts of hand with lead gown on hands and on body are each 1554 cps, 1299 cps. Conclusion Therefore, even though there is a collimator in front of detector, lateral scatter rays detect on crystal and affect to images and spectrums. Especially, if there is a high activity source at outside of detector when we examine low activity organs like hands or foot, we have to shield and remove the source at outside for a good image.

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.