• Title/Summary/Keyword: Universal statistical test

Search Result 112, Processing Time 0.028 seconds

Study on the Fatigue Test and the Accelerated Life Test for Dental Implant using Universal-Joint Test Type (유니버설조인트 시험방식을 이용한 치과용 임플란트의 피로시험 및 가속수명시험에 관한 연구)

  • Do, Gyeong Hun;Lee, Seok Jin;Kim, Jong Mi;Kim, Sung Min
    • Journal of Applied Reliability
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • Purpose : This paper is a comparative analysis results of the fatigue test for dental implants and accelerated life test by using a static type loading device commonly used in Korea and a dynamic type loading device (universal-joint) recommended by FDA. Methods : Fatigue tests of dental implant is based on ISO 14801 and classified into static load test and dynamic load test. The tests were carried out on three test specimens by four load stress steps under each loading device. For analysis on failure mode such as crack, fracture and permanent deformation of test specimens, we used X-ray three-dimensional computed tomography on test specimens before and after the fatigue tests. The design of the accelerated life test was based on the analysis results of the fatigue life data obtained from the dynamic load test and the statistical analysis software (Minitab ver.15) was used to analyze the appropriate life distribution. Results : As a result of the fatigue tests and the accelerated life tests at same acceleration condition under each test method, the fatigue life under the dynamic type loading device (universal-joint) was shorter than when static type loading device was applied. Conclusion : This paper can be used as a reference when the universal-joint type loading device for implants fatigue test is applied as ISO 14801.

On the Length of Sample Sequence in Universal Statistical Test (유니버설 통계적 검정에서 표본 수열의 길이에 대한 분석)

  • 강주성
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.8 no.3
    • /
    • pp.105-114
    • /
    • 1998
  • Maurer가 제안한 유니버설 통계적 검정을 소개하고 검정에 사용된 통계량의 의미를 분석한다. 기존 검정법을 포괄하는 이 검정법은 보다 넓은 의미의 통계적 결점들을 탐지해낼 수 있다. 또한, 검정에 사용되는 통계량은 엔트로피와 밀접한 연관이 있으며 암호학적 응용에서 시스템의 안전성에 영향을 키치는 요소들을 탐지해 낸다. 이러한 특징과 함께 기존 검정법 보다 상당히 긴 표본 수열을 필요로 한다는 사실이 유니버설 검정의 단점으로 지적되어 왔다. 그러나 본 논문에서는 빈도(freequency) 검정법과의 비교를 통해서 미세한 편의(bias)를 탐지해내기 위한 도구로서는 유니버설 검정이 오히려 더 효율적이라는 사실을 보였다.

Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatment

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.34-38
    • /
    • 2017
  • Objectives: The aim of this study was to evaluate the cyclic fatigue resistance of the ProTaper Universal D1 file (Dentsply Maillefer) under continuous and adaptive motion. Materials and Methods: Forty ProTaper Universal D1 files were included in this study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which had an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5 mm radius of curvature. The files were randomly divided into two groups (Group 1, Rotary motion; Group 2, Adaptive motion). The time to failure of the files were recorded in seconds. The number of cycles to failure (NCF) was calculated for each group. The data were statistically analyzed using Student's t-test. The statistical significant level was set at p < 0.05. Results: The cyclic fatigue resistance of the adaptive motion group was significantly higher than the rotary motion group (p < 0.05). Conclusion: Within the limitations of the present study, the 'Adaptive motion' significantly increased the resistance of the ProTaper Universal D1 file to cyclic facture.

RESEARCH ON THE DEVELOPMENT OF COLLEGE STUDENT EDUCATION BASED ON MACHINE LEARNING - TAKE THE PHYSICAL EDUCATION OF YANBIAN UNIVERSITY AS AN EXAMPLE

  • Quan, Yu;Guo, Wei-Jie;He, Lin;Jin, Zhe-Zhi
    • East Asian mathematical journal
    • /
    • v.38 no.1
    • /
    • pp.65-84
    • /
    • 2022
  • This paper is based on Yanbian University's physical test data, and uses statistical analysis methods to study the relationship between college students' physical test scores to promote college physical education. Firstly, using gender as categorical variables, we conduct a general analysis of students in different majors and different grades, and obtain the advantages and disadvantages of male and female college students; then we use Decision Trees and Random Forest algorithms to conduct modeling analysis to provide valuable suggestions for relevant departments of the university. the aiming of this research analyzing about the undergraduates physical test is that giving universities the targeted suggestions to improve the college graduate rate and promote the overall development of higher education, lay the foundation for achieving universal health.

Comparison of flexural strength and modulus of elasticity in several resinous teeth splinting materials (여러 레진계 치아고정 재료의 굴곡강도 및 탄성계수 비교)

  • Yoo, Je-In;Kim, Soo-Yeon;Batbayar, Bayarchimeg;Kim, Jin-Woo;Park, Se-Hee;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.169-175
    • /
    • 2016
  • Purpose: Direct splinting material should have high flexural strength to withstand force during mastication and low modulus of elasticity to provide some movement while force applied for relief of stress. The purpose of this study was to compare flexural strength and modulus of elasticity of several resinous splinting materials. Materials and Methods: Four materials; Super-Bond C&B, G-FIX, G-aenial Universal Flo, FiltekTM Z350 XT; were used in this study. Fifteen rectangular bar specimens of each material were prepared. Three-point bending test were performed to determine physical properties. Maximum load at fracture was recorded and flexural strength and modulus of elasticity were calculated. One-way analysis of variance (ANOVA) and Scheffe's tests at a 0.05 level of significance were conducted on all test results. Results: Statistical analysis reveals that Super-Bond C&B had significant low mean value for flexible strength and the other three materials showed no significant difference. For modulus of elasticity, Super-Bond C&B exhibited statistically lower modulus of elasticity. G-FIX presented intermediate result, showing statistically higher modulus of elasticity than Super-Bond C&B but lower than G-aenial Universal Flo and FiltekTM Z350 XT. There was no significant difference on modulus of elasticity between G-aenial Universal Flo and FiltekTM Z350 XT. Conclusion: Using a G-FIX, the newly commercially available splinting material, which shows higher fracture resistance properties comparable to flowable and restorative composite resin and a relatively flexible nature might be a beneficial for stabilizing teeth mobility.

Surface gloss, gloss retention, and color stability of 2 nano-filled universal resin composites

  • Gustavo Fabian Molina;Ricardo Juan Cabral;Ignacio Mazzola;Michael Burrow
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.4
    • /
    • pp.43.1-43.13
    • /
    • 2022
  • Objectives: This study compared the surface gloss (SG), gloss retention (GR), and color stability (CS) of 2 universal resin composites after chemical (CA) and mechanical (MA) aging. Materials and Methods: Twenty disc-shaped samples of G-ænial A'Chord (GC-Europe) and Filtek Universal (3M-ESPE) were polished with sequential abrasive papers. For CA, specimens were stored in 1 mL of 75% ethanol for 15 days at 37℃, and readings (SG, GR, and CS) were obtained at baseline and 5, 10, and 15 days. For MA, specimens were subjected to 10,750 simulated brushing cycles. SG and CS were evaluated after every 3,583 cycles. SG was measured with a glossmeter (geometrical configuration: 60°), and values were expressed in gloss units. Color was measured with a spectrophotometer using the CIE-L*a*b* color system. The Student's t-test, 1-way analysis of variance, and Scheffé test were used for statistical analysis (α = 0.05). Results: G-ænial presented significantly higher SG values than Filtek (p = 0.02), with GR reductions of 5.2% (CA) and 5.3% (MA) for G-ænial and 7.6% (CA) and 7.2% (MA) for Filtek. The aging protocol had no statistically significant effect on SG or GR (p = 0.25) from baseline to the final readings. G-ænial-MA presented the lowest color difference (ΔE = 1.8), and G-ænial-CA and Filtek-CA had the largest changes (ΔE = 8.6 and ΔE = 11.8, respectively). Conclusion: G-ænial presented higher SG values and better CS. Both restorative materials demonstrated acceptable GR and CS. Aging protocols impacted these properties negatively.

A Study on Physical Service Environment and Customer's Satisfaction in Multiplex (멀티플렉스에서의 물리적 서비스환경과 고객의 만족에 관한 연구)

  • Chang Kyung;Ko Hyun-Min
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.2
    • /
    • pp.29-36
    • /
    • 2004
  • As Lately movie industry and related market becomes larger and people have had more spare time, people's interest in multiplex grows higher, This paper studies relationships between physical service environment and customer's satisfaction in multiplex. The number of subjects in this study is 346 persons stayed at four multiplexes, among which we obtained valid responses from 326 persons through questionnaire investigation. We held hypotheses for the relationships, and for the testing, used methods are Spearman's correlation, Mann-Whitney test, etc, and for statistical analysis, SPSS 10.1 software was used. Thus, we found statistically significant results, that is, the relation between physical service environment and customer's satisfaction is positive: the higher evaluation about physical service environment is, the more customer's universal satisfaction is. Information about the significant relation's intensity of many indicators in physical service environment, which is given in this paper, can be used for attaining higher customer satisfaction and spreading more effective management activities in multiplex.

Bond Strength between Co-Cr Alloy Metal and Ceramic (Co-Cr 합금의 금속-도재 결합 강도)

  • Kim, Min-Jeong;Park, Gwang-Sig
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.3
    • /
    • pp.602-608
    • /
    • 2021
  • For the comparison of bond strength between the Co-Cr alloy and ceramic, which are clinically used, test samples made with a traditional casting method as a control group), and Milling and SLM(3d printing group) samples were made as an experimental group. The metal-ceramic bond strength was measured with a universal testing machine. For the measurement, a three-point bending test was conducted. After the bond strength was measured, metal-ceramic interface was observed. According to the test result, casting group had 53.59 MPa, milling group had 45.90 MPa, and 3d printing group had 58.34 MPa. There was no statistical significance. With regard to failure pattern, most of the samples in two groups, showed mixed failure. This study showed a clinically applicable value when measuring the bond strength of alloy-ceramic material with an alloy produced by 3D printing.

A Study on Development of Test Model and Linkage Method among International Standard Identification Systems and UCI/ICN (UCI/ICN과 국제표준 식별체계간의 연계방법과 시험모형개발에 대한 연구)

  • Kim, Yoonho
    • The Journal of Society for e-Business Studies
    • /
    • v.19 no.4
    • /
    • pp.151-168
    • /
    • 2014
  • UCI (Universal Content Identifier) as a national digital content identification system for identifying digital content and ICN (Integrated Copyright Number) for copyright management are operated by Korea copyright commission. However, They are not interoperable with international standard identification system such as ISRC (International Standard Recording Code), ISWC (International Standard Works Code), and ISAN (International Standard Audiovisual Number) due to lack of linkage system. Hence, extra works with international standard identification system are needed for international market entry and integrated management of statistical information including content settlement in international market is impossible. In this paper, the domestic/international identification systems are surveyed, and by metadata analysis of identification systems, linkage method with UCI/ICN is proposed. And also by developing the prototype model, research direction to UCI/ICN with international standard identification system is proposed.

New Blind Steganalysis Framework Combining Image Retrieval and Outlier Detection

  • Wu, Yunda;Zhang, Tao;Hou, Xiaodan;Xu, Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.12
    • /
    • pp.5643-5656
    • /
    • 2016
  • The detection accuracy of steganalysis depends on many factors, including the embedding algorithm, the payload size, the steganalysis feature space and the properties of the cover source. In practice, the cover source mismatch (CSM) problem has been recognized as the single most important factor negatively affecting the performance. To address this problem, we propose a new framework for blind, universal steganalysis which uses traditional steganalyst features. Firstly, cover images with the same statistical properties are searched from a reference image database as aided samples. The test image and its aided samples form a whole test set. Then, by assuming that most of the aided samples are innocent, we conduct outlier detection on the test set to judge the test image as cover or stego. In this way, the framework has removed the need for training. Hence, it does not suffer from cover source mismatch. Because it performs anomaly detection rather than classification, this method is totally unsupervised. The results in our study show that this framework works superior than one-class support vector machine and the outlier detector without considering the image retrieval process.