• Title/Summary/Keyword: Universal adhesive

Search Result 237, Processing Time 0.021 seconds

INFLUENCE OF APPLICATION METHODS OF A DENTIN ADHESIVE ON SHEAR BOND STRENGTH AND ADHESIVE PATTERN (상이질 접착제의 적용방법에 따른 전단결합강도와 접착양상에 관한 연구)

  • Park, Sung-Taek;Moon, Joo-Hoon;Cho, Young-Gon;Ohn, Yeong-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.381-391
    • /
    • 1999
  • A new 5th generation adhesive system(ONE-STEP) has been supplied which operators can apply to conditioned tooth surfaces by one simplified step. The purpose of this study was to determine whether different methods of adhesive application and various air drying duration after applying adhesive affect the shear bond strength of composite resin to dentin, and to evaluate the adhesive pattern of composite resin and dentin under SEM. Seventy-seven extracted human molar teeth were cleaned and mounted in palstic test tubes. The occlusal dentin surfaces were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A.). Teeth were randomly divided into 7 groups (n=11), In experimental A group, adhesive was applied to dentin with agitation for 20 sec. In experimental N-A group, adhesive were continuously applied to dentin for 20 sec. Also control and experimental 1, 2, 3, 4 groups were dried for 10, 0, 5, 20, 30 seconds after applying adhesive, respectively, Adhesives were light cured for 10 sec. A gelatin capsule 5mm in diameter was filled with Aelitefil$^{TM}$ composite resin, placed on the treated dentin surface and light cured for 40 see, from three sides, All specimens were stored in distilled water at room temperature for 24 hours. The shear bond strengths were measured using a universal testing machine(AGS-1000 4D, Japan) at a crosshead speed of 5mm/min. An one-way ANOVA and LSD test were used for statistical analysis of the data. For SEM evaluation, seven specimens were made and sectioned. Representive postfracture and seven specimens were mounted on brass stubs, sputter-coated with gold and observed under SEM. The results were as follows : 1. The shear bond strength of experimental A group which adhesive were applied to dentin with agitation was higher than that of experimental N-A group (continuous application), and there was significant difference between two groups (p<0.01). 2. The interface between composite and dentin according to different application methods showed close adaptation in experimental A group and showed tinny gap in experimental N-A group. 3. The shear bond strength accoding to various air drying duration was the lowest value(7.57${\pm}$2.60 MPa) in experimental 1 group, so there was significant difference between experimental 1 group and other four groups (p<0.05). But there was no significant difference of shear bond strength between four groups (p>0.05). 4. The interface between composite and dentin according to various air drying duration showed close adaptation in control group and tinny gap in experimental 3 and 4 groups. But experimental 1 and 2 groups showed $30{\mu}$ and 6 - $10{\mu}m$ thick gaps, respectively.

  • PDF

COMPARISON OF SHEAR BOND STRENGTHS OF FOUR DENTINAL ADHESIVES (네가지 상아질 접착제의 전단 결합 강도 비교)

  • Cho, Kyeong-Mee;Hur, Bock;Lee, Hee-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.280-288
    • /
    • 1996
  • The purpose of this study was to assess comparatively the shear bond strength on dentin of four dentin bonding agents used in conjunction with light-curing composite resins. Clearfil New Bond, Scotchbond Multipurpose Dentin Adhesive, All-Bond 2 and X-R Bond were applicated on labial dentin surfaces just below dentin - enamel juction of bovine incisor teeth. After shear bond strength testing with the universal testing machine, the bonding interface of the specimens were observed under light stereomicroscope. Following results were obtained. 1. The shear bond strength was high in the order of B,C,D,A and group B Scotchbond Multipurpose Dentine Adhesive revealed greater bond strength than Clearfil New Bond and X-R Bond. (p<.001) 2. When using ANOVA and Duncan's multiple range test, there were statistical differences among the four groups, except between group Band C,group D and A. 3. There was no relationship between mode of failure and shear bond strength.

  • PDF

The Microleakage in Class V Cavity Based on Different Kinds of Several Dentin Adhesive and Composite Resin (5급 와동에서 수종의 상아질 접착제와 복합레진의 종류에 따른 미세누출)

  • Choi, Yoo-Seok;Jeong, Soon-Jeong;Jeong, Moon-Jin;Ahn, Yong-Soon;Park, Seon-Nyeo;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.13 no.3
    • /
    • pp.330-338
    • /
    • 2013
  • In order to explore microleakage in class V cavity based on different kinds of several dentin adhesive and composite resin, 2 kinds of composite resin was restored and exposed after applying 4 kinds of dentin adhesives. Deposited in methylene blue solution for 4 hours and cut in parallel with tooth longitudinal axis. By observing dye penetration level of enamel and dentin margins of each restored resin following conclusion was obtained. 1. In composite resin Filtek Z350XT Universal (3M/ESPE Dental Products, USA) in enamel margin, Easy Bond (3M/ESPE Dental Products) showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2 (3M/ESPE Dental Products), Scotchbond Multi-Purpose (3M/ESPE Dental Products) and Cearfil SE Bond (Kuraray Medical Inc., Japan). In case of Filtek Z350XT Flowable (3M/ESPE Dental Products), Scotchbond Multi-Purpose showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2, Clearfil SE Bond and Easy Bond. 2. In case of Filtek Z350XT Universal in dentin margin, Easy Bond showed the lowest microleakage and this leakage was represented to be high in the order of Scotchbond Multi-Purpose, Single Bond 2 and Clearfil SE Bond. In case of Filtek Z350XT Flowable, Scotchbond Multi-Purpose and Single Bond showed the lowest microleakage and this leakage was represented to be high in the order of Clearfil SE Bond and Easy Bond. 3. In all the groups excepting S-U group (Single Bond 2+Filtek Z350XT Universal), enamel margin showed more higher microleakage than that of dentin margin. 4. There was a difference between enamel and dentin margin among each group but it was not significant statistically (p>0.05). When summarizing this result, it is considered that composite resin and dentin adhesive could be applied selectively and particularly in case of applying 1-step self-etching dentin adhesive, this method would be advantageous for manipulation convenience and shortening of operation time.

Effect of PPG, MDI, 2-HEMA and butyl acrylate content on the properties of polyurethane adhesive (폴리우레탄 접착제의 물성에 미치는 PPG, MDI, 2-HEMA 및 butyl acrylate량의 영향)

  • Park, Chan Young
    • Elastomers and Composites
    • /
    • v.49 no.3
    • /
    • pp.245-252
    • /
    • 2014
  • FT-IR measurement and the physical properties of polyurethane adhesive prepared from the polyol, isocyanate, 2-HEMA and other acrylate monomers were examined. The softening point, viscosity, adhesion strength and mechanical properties of the PU adhesives were reviewed by Ring and Ball method, Brookfield viscometer and universal test machine, respectively. Results revealed that increment of both PPG amount and butyl acrylate content decreased softening point, adhesion strength, tensile strength and 100% modulus. However as 2-HEMA and MDI content increased the mechanical properties including tensile strength, 100% modulus increased, and also the viscosity and NCO content increased.

Shear Bond Strength of a 3-in-1 Flowable Composite Resin to Primary Teeth (유치에 대한 3-in-1 유동성 복합레진의 전단결합강도)

  • Lee, Hyeongjik;Shin, Jonghyun;Kim, Jiyeon;Jeong, Taesung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.436-444
    • /
    • 2018
  • The purpose of this study was to compare the shear bond strengths of 3-in-1 flowable composite to the enamel and dentin of primary teeth to previous adhesive systems. 110 primary incisors were prepared and divided into two groups: Dentin group included 5 groups: 1) Scotch bond Multi-purpose plus(DSM), 2) Single-bond 2(DSB), 3) Clearfil SE bond(DSE), 4) All bond universal(DAB), 5) Constic(DC), and Enamel group included 6 groups: 1) Scotch bond Multi-purpose plus(ESM), 2) Single bond 2(ESB), 3) Clearfil SE bond(ESE), 4) All bond universal(EAB), 5) Constic(EC), 6) Constic with additional etching(ECE). A cylinder of composite was bonded to the prepared surface, and the shear bond strength was measured. In the dentin groups, group DC had significantly lower shear bond strength than group DSE. No significant difference was found between group DC, group DSM, group DSB and group DAB. In the enamel groups, there was no significant difference between group EC, group ESE, and group EAB. This material showed lowest shear bond strength among all tested materials in both enamel and dentin groups, showing insignificant difference with some adhesive systems. Therefore, 3-in-1 flowable composite can be used for primary teeth restoration but further studies are needed.

IN VITRO SHEAR BOND STRENGTH OF CERAMIC BRACKETS (도재 브라켓의 전단접착강도에 관한 실험적 연구)

  • Lee, Suhng-Jin;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.22 no.2 s.37
    • /
    • pp.449-474
    • /
    • 1992
  • The purpose of this study was to evaluate the in vitro shear bond strengths to enamel and the failure sites of three ceramic brackets and one metal bracket in combination with light cured orthodontic adhesive. The brackets were divided into four groups. Each ceramic bracket group had different bonding mechanisms with adhesive. Group A; metal bracket with foil-mesh base (control group) Group B; ceramic bracket with micromechanical retention Group C; ceramic bracket with chemical bonding Group D; ceramic bracket with mechanical retention and chemical bonding. Forty extracted human lower first premolars were prepared for bonding and 10 brackets for each group were bonded to prepared enamel surfaces with $Transbond^{\circledR}$ light cured ortho dontic adhesive. Twenty four hours after bonding, the Instron universal testing machine was used to test the shear bond strength of brackets to enamel. After debonding, brackets and enamel surfaces were examined under stereoscopic microscope to determine the failure sites, Statistical analysis of the data was carried out with ANOVA test and $Scheff\acute{e}$ test using SPSS PC+. The results were as follows. 1 . There were statistically significant differences in mean shear bond strengths of three ceramic bracket groups (p < 0.05). Shear bond strengths of group C and D were significantly higher than that of group B and shear bond strength of group C was significantly higher than that of group D. 2. Group C and D both had significantly higher shear bond strengths than metal bracket (group A), but there were no significant differences in shear bond strengths between group A and B (p < 0.05). 3. The failure sites of four bracket groups were also different. Group C and D failed primarily at enamel-adhesive interface, but group A and B failed primarily at bracket base-adhesive interface. 4. Among all ceramic bracket groups, group B was very similar to metal bracket in the aspect of shear bond strength and failure site.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH BETWEEN RESIN-BONDED RETAINERS AND ENAMEL ACCORDING TO THE ADHESIVE RESINS AND RETENTION TYPES (유지형태와 접착제 종류에 따른 수지 접착형 수복물과 법랑질간의 전단결합강도 및 파절양상에 관한 연구)

  • Cho, Mi-Sook;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.662-684
    • /
    • 1995
  • The purpose of this study was to evaluate the shear bond strength between various resin-bonded retainers and enamel according to the adhesive resins and retention types and observe the bond filure modes with scanning electron microscope(SEM). For this purpose, the followin eight sub-groups were tested in shear bond strength : 1) electrochemically etched group(Verabond) using Panavia EX and Superbond C&B 2) tin-plated group(PG-S) using Panavia EX and Superbond C&B 3) salt-treated group(Verabond) using Panavia EX and Superbond C&B 4) meshtreated group(Verabond) using Panavia EX and Superbond C&B. Thermocycling test was conducted on the condition of 15 second dwell time each in $5^{\circ}C$ and $55^{\circ}C$bath. Shear bond strength was measured by Instron Universal Testing Machine(medel 1125). The obtained results were as follows : 1. After thermocycling, the shear bond strengths of tin-plated group and electrochemically etched group were significantly greater than those of salt-treated group and mesh-treated group. And the shear bond strength of Panavia EX was greater than that of Superbond C&B with salt-treated group and tin-plated group(p<0.05). 2. Before thermocycling, electrochemically etched group using Superbond C&B produced the greatest shear bond strength(p<0.01). 3. The shear bond strength of electrochemically etched group using Superbond C&B was significantly decreased after thermocycling(p<0.01). 4. In observation of bond failure modes before thermocycling, Panavia EX highly exhibited enamel fracture. Tin-plated group using Superbond C&B adhesive failure between metal and resin and electrochemically etched group using Superbond C&B exhibited adhesive failure between enamel and rdsin. 5. In observation of failure modes after thermocycling, Panavia EX exhibited cohesive failure and Superbond C&B exhibited adhesive failure between resin and metal.

  • PDF

Synthesis and Properties of Eco-friendly Polyurethane Adhesive without Solvent : Effect of DPE-41, TDI, Initiator and Plasticizer Content (용제를 사용하지 않는 친환경 폴리우레탄 접착제의 합성 및 물성 : DPE-41, TDI, 개시제 및 가소제량의 영향)

  • Ryu, Ki-Jung;Park, Chan-Young
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1909-1918
    • /
    • 2014
  • In this experiment no solvent based polyurethane(PU) adhesives were prepared with the polyol, isocyanate, dioctyl phthalate(DOP), 2-hydroxyethylacrylate(2-HEA) and other acrylate monomers. The softenening point of the PU adhesives measured by Ring & Ball method were examined in the present study. And adhesion strength and mechanical properties such as tensile strength and 100% modulus of the PU adhesives were evaluated by Universal Test Machine. The experimental results showed that increase of both DPE-41, benzoylperoxide(BPO) and toluene diisocyanate(TDI) increased softenening point, adhesion strength, tensile strength and 100% modulus. However as DOP content increased sofenening point, adhesion strength decreased and tensile strength, 100% modulus also decreased.

AII-Bond - Fourth Generation Dentin Bonding System

  • Suh, Byoung I.
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.3 no.1
    • /
    • pp.23-31
    • /
    • 1995
  • The All-Bond system is a unique development in the field of adhesive dentistry. It is a universal bonding system that will bond composite to all dental-related surfaces: dentin, enamel, metal alloy (precious and nonprecious), amalgam, porcelain, and composite. It is also the only system that allows use of both the conservative and all-etch techniques. The main purpose of this paper is to explain the features of the All-Bond system. Its chemistry and a working hypothesis are shown as well.

  • PDF

Effect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials

  • Sismanoglu, Soner;Gurcan, Aliye Tugce;Yildirim-Bilmez, Zuhal;Turunc-Oguzman, Rana;Gumustas, Burak
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.22-32
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the microshear bond strength (µSBS) of four computer-aided design/computer-aided manufacturing (CAD/CAM) blocks repaired with composite resin using three different surface treatment protocols. MATERIALS AND METHODS. Four different CAD/CAM blocks were used in this study: (1) flexible hybrid ceramic (FHC), (2) resin nanoceramic (RNC), (c) polymer infiltrated ceramic network (PICN) and (4) feldspar ceramic (FC). All groups were further divided into four subgroups according to surface treatment: control, hydrofluoric acid etching (HF), air-borne particle abrasion with aluminum oxide (AlO), and tribochemical silica coating (TSC). After surface treatments, silane was applied to half of the specimens. Then, a silane-containing universal adhesive was applied, and specimens were repaired with a composite, Next, µSBS test was performed. Additional specimens were examined with a contact profilometer and scanning electron microscopy. The data were analyzed with ANOVA and Tukey tests. RESULTS. The findings revealed that silane application yielded higher µSBS values (P<.05). All surface treatments were showed a significant increase in µSBS values compared to the control (P<.05). For FHC and RNC, the most influential treatments were AlO and TSC (P<.05). CONCLUSION. Surface treatment is mandatory when the silane is not preferred, but the best bond strength values were obtained with the combination of surface treatment and silane application. HF provides improved bond strength when the ceramic content of material increases, whereas AlO and TSC gives improved bond strength when the composite content of material increases.