• Title/Summary/Keyword: Universal Testing Machine

Search Result 791, Processing Time 0.027 seconds

Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins

  • Asar, Neset Volkan;Albayrak, Hamdi;Korkmaz, Turan;Turkyilmaz, Ilser
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.241-247
    • /
    • 2013
  • PURPOSE. To evaluate the effect of various metal oxides on impact strength (IS), fracture toughness (FT), water sorption (WSP) and solubility (WSL) of heat-cured acrylic resin. MATERIALS AND METHODS. Fifty acrylic resin specimens were fabricated for each test and divided into five groups. Group 1 was the control group and Group 2, 3, 4 and 5 (test groups) included a mixture of 1% $TiO_2$ and 1% $ZrO_2$, 2% $Al_2O_3$, 2% $TiO_2$, and 2% $ZrO_2$ by volume, respectively. Rectangular unnotched specimens ($50mm{\times}6.0mm{\times}4.0mm$) were fabricated and drop-tower impact testing machine was used to determine IS. For FT, compact test specimens were fabricated and tests were done with a universal testing machine with a cross-head speed of 5 mm/min. For WSP and WSL, disc-shaped specimens were fabricated and tests were performed in accordance to ISO 1567. ANOVA and Kruskal-Wallis tests were used for statistical analyses. RESULTS. IS and FT values were significantly higher and WSP and WSL values were significantly lower in test groups than in control group (P<.05). Group 5 had significantly higher IS and FT values and significantly lower WSP values than other groups (P<.05) and provided 40% and 30% increase in IS and FT, respectively, compared to control group. Significantly lower WSL values were detected for Group 2 and 5 (P<.05). CONCLUSION. Modification of heat-cured acrylic resin with metal oxides, especially with $ZrO_2$, may be useful in preventing denture fractures and undesirable physical changes resulting from oral fluids clinically.

Fluoride Release and Compressive Strength of Several Giomers (수종의 자이오머의 불소 유리량과 압축 강도 평가)

  • Kang, Jieun;Yoo, Seunghoon;Kim, Jongbin;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.3
    • /
    • pp.292-298
    • /
    • 2016
  • The aim of this study was to compare the compressive strength and amount of fluoride-release of recently developed giomers (Beautifil Flow Plus F00, Beautifil Flow Plus F03), conventional giomer, resin-modified glass ionomer and composite resin. Fifteen cylindrical specimens for each group were prepared to measure fluoride release. It was measured using pH/ISE meter and fluoride ion electrode every 24 hours for the first 7 days and every 72 hours until the 31st day. Also, fifteen cylindrical specimens for each group after thermocycling were prepared to measure compressive strength. The universal testing machine (Kyung-sung Testing Machine Co., Korea) was used and the crosshead speed was 1 mm/min. Recently developed giomers showed more fluoride release and higher compressive strength than conventional giomer. It would be a good alternative to composite resin.

Synthesis and Self-healing Properties of Waterborne Polyurethane Based on Polycarbonate and Polyether Polyol (폴리카보네이트계 및 폴리에테르계 폴리올 기반 자가치유 기능 수분산 폴리우레탄 합성과 특성)

  • Kwon, Seon-Young;Park, Soo-Yong;Paik, In Kyu;Chung, Ildoo
    • Journal of Adhesion and Interface
    • /
    • v.23 no.1
    • /
    • pp.8-16
    • /
    • 2022
  • In this study, self-healable waterborne polyurethane (SH-WPU) as shoes and coating materials with self-healable disulfide functionalities was synthesized by mixing polyether polyol to impart excellent durability and heat resistance and polycarbonate polyol to impart excellent mechanical properties. The synthesized SH-WPU was characterized by fourier transform-infrared spectroscopy (FT-IR), and physical and self-healing properties were confirmed through universal testing machine (UTM) and scanning electron microscope (SEM) measurements. Tensile strength and hardness were increased and elongation was decreased by using polycarbonate polyol. In addition, as a result of comparison of thermal properties, thermal stability has been increased as the content of polycarbonate polyol increased. The healing efficiency showed the highest efficiency when poly(tetramethylene ether)glycol : polycarbonate polyol = 0.75 : 0.25, and it was confirmed that the damaged part was healed through surface observation using a microscope and SEM.

Analysis of mechanical properties of agricultural products for development of a multipurpose vegetable cutting machine

  • Park, Jeong Gil;Jung, Hyun Mo;Kang, Bum Seok;Mun, Seong Kyu;Lee, Seung Hun;Lee, Seung Hyun
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.3
    • /
    • pp.432-440
    • /
    • 2016
  • The consumption of pre-treated vegetables (including fresh-cut vegetables) that are washed, peeled, and trimmed has been significantly increased because of their easy use for cooking. Vegetable cutting machines have been widely utilized for producing fresh-cut vegetables or agricultural products of different sizes; however, the design standard is not established for specific types of agricultural products. Therefore, this study was conducted to determine mechanical properties (compressive and shear forces) of targeted agricultural products (radish, carrot, squash, cucumber, shiitake mushroom, and sweet potato) for developing a multipurpose vegetable cutting machine. According to ASAE standard (s368.3), compressive and shear forces of targeted agricultural products were measured by using a custom built UTM (universal testing machine). Shape type of samples and speed ranges (5 - 15 mm/min) of loading rate on bioyield and shear points varied depending on the targeted agricultural product. The range of averaged bioyield points of targeted agricultural products were between 7.89 and 146.98 N. On the other hand, their averaged shear points ranged from 22.50 to 53.47 N. Results clearly showed that the bioyield and shear points of targeted agricultural products were thoroughly affected by their components. As measuring compressive and shear forces of a variety of agricultural products, it will be feasible to calculate blade cutting force for designing multipurpose vegetable cutting machine.

A Study on the Peel Strength of Silane-treated Silicas-filled Epoxy Adhesives (실란처리 되어진 실리카가 첨가된 에폭시 접착제의 접착박리강도에 관한 연구)

  • Choi, Bo-Kyung;Kim, Hong-Gun;Seo, Min-Kang;Park, Soo-Jin
    • Applied Chemistry for Engineering
    • /
    • v.25 no.5
    • /
    • pp.520-525
    • /
    • 2014
  • In this paper, the effect of silane-treated silicas and epoxidized soybean oil (ESBO) addition on adhesion properties of silicas-filled epoxy adhesives was examined. The silicas were treated by ${\gamma}$-methacryloxy propyltrimethoxy silane (MPS), ${\gamma}$-glycidoxy propyl trimethoxy silane (GPS), and ${\gamma}$-mercapto propyl trimethoxy silane (MCPS). Surface and structural properties of the adhesives were determined by using scanning electron microscope (SEM) and Fourier transform infrared spectroscopy (FT-IR). The t-peel strength of the adhesives was estimated using the universal testing machine (UTM). And, the equilibrium spreading pressure, surface free energy, and specific surface area were investigated by BET methods with $N_2$/77 K adsorption. As a result, the peel strength of the adhesives was increased in the presence of silane-treated silicas in the adhesives compared to that of untreated silicas. This result indicated that the silane coupling agent played an important role in improving the dispersion of silicas in epoxy adhesives. And, the adhesives treated by MCPS were superior to the others in adhesion.

Measurement of Contact Angle and Bond Strength Using 3 Different Self-Etching Primer (3종의 자가부식 프라이머의 상아질계면 접촉각 및 미세인장결합강도에 관한 연구)

  • Chang, Seok-Woo;Kwon, Ho-Beom;Yoo, Hyun-Mi;Park, Dong-Sung;Oh, Tae-Seok;Bae, Kwang-Shik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.105-112
    • /
    • 2008
  • The purpose of this study was to evaluate the contact angle made by 3 kinds of self etching primers (Clearfil SE Bond, AdheSE, and Tyrian) on dentin and to measure the microtensile bond strength of resin composite to dentin using these self-etching primers. Contact angle between each of 3 self etching primers and polished dentin surface was measured (n=30) by contact angle analyzer and the result was analyzed by One-way ANOVA. For the measurement of microtensile bond strength, polished dentin surface was treated with each of 3 self etching primers and dentin adhesives. Z-250 composite resin was built-up with a height of 5 mm on the adhesive-treated surface and light cured for 40s with a halogen light curing unit. Thereafter, each tooth was sectioned into slabs perpendicular to the bonded interface and trimmed (n=45). The microtensile bond strength was measured with universal testing machine and the result was analyzed with Kruskal-Wallis test. AdheSE group showed the highest contact angle followed by Clearfil SE group and Tyrian group (p<0.05). AdheSE group and Clearfil SE group showed significantly higher microtensile bond strength than Tyrian group (P<0.05).

Comparison of Shear Bond Strength of Different Restorative Materials to Tricalcium Silicate-Based Pulp Capping Materials (Tricalcium Silicate-Based 치수복조재에 대한 수 종 수복재의 전단결합강도 비교)

  • Jeong, Hwakyong;Lee, Nanyoung;Lee, Sangho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.2
    • /
    • pp.200-209
    • /
    • 2017
  • The aim of this study was to evaluate the shear bond strength (SBS) of three typical restorative materials - glass ionomer cement (GIC), resin-modified glass ionomer (RMGIC) and composite resin (CR) - to different pulp capping materials, i.e., Theracal $LC^{TM}$ (TLC), $Biodentine^{TM}$ (BD), and $ProRoot^{TM}$ white MTA (WMTA). 90 acrylic blocks with a center hole were prepared. The holes were completely filled with three pulp capping materials (TLC, BD, and WMTA), with 30 specimens per capping material. The samples were then randomly divided into 3 subgroups of 10 specimens each and were overlaid with GIC, RMGIC, or CR. A total 9 specimen groups were prepared. The SBS was assessed using a universal testing machine. Kruskal-Wallis test and Mann-Whitney's test were performed to compare the SBS among the subgroups (p < 0.05). After the SBS test, the fractured surfaces were examined under a stereomicroscope at a magnification of $25{\times}$. The highest and lowest SBS values were recorded for TLC-CR and TLC-GIC, respectively. With regard to the SBS to the three pulp capping materials, CR was found to be superior to RMGIC and GIC. BD showed a higher SBS compared to TLC and WMTA when used with GIC.

Study of the fracture resistance of zirconia on posterior fixed partial dentures based on inter-abutment distance (지르코니아 고정성 국소의치의 지대치간 거리에 따른 파절저항성에 관한 연구)

  • Park, Gi-Beom;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.61-69
    • /
    • 2020
  • Purpose: Zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments are fabricated and then the effects of inter-abutment distance on fracture resistance of zirconia fixed partial dentures is studied. Materials and Methods: The materials used in this study are Cameleon S zirconia block and S2 zirconia block, which are divided into CS Group and S2 Group applying different inter-abutment distance for each material, and the sintered zirconia fixed partial denture was luted to the epoxy resin die using a temporary luting cement, and then the fracture resistance was measured by placing a 6 mm diameter hardened steel ball on the occlusal surfaces of the pontics and applying pressure at a cross head speed of 1.0 mm/min on a universal testing machine with a load cell of 5.0 kN. Results: The fracture resistance of zirconia fixed partial dentures is not significantly affected by inter-abutment distance The fracture resistance of zirconia fixed partial dentures in CS Group was significantly higher in 15 mm of inter-abutment distance than in 13 mm and 17 mm of inter-abutment distance (P < 0.05). The fracture resistance of zirconia fixed partial dentures in S2 Group was not significantly different between the three groups (P > 0.05). Conclusion: The fracture resistance of zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments does not significantly affected by the inter-abutment distance.

The effect of chlorhexidine varnish application on the shear bond strength of orthodontic brackets (클로르헥시딘 바니쉬의 적용이 교정용 브라켓의 전단접착강도에 미치는 영향)

  • Im, Dong-Hyuk;Kim, Tae-Woo;Chang, Young-Il;Nahm, Dong-Suk;Yang, Won-Sik;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.215-222
    • /
    • 2000
  • The purpose of this study was to determine whether the application of chlorhexidine varnish affects the shear bond strength and failure pattern of orthodontic brackets or not. The experimental group consisted of 22 human premolars which extracted after chlorhexidine varnish application (4 times for 1 week interval) in vivo, and the control group consisted of 22 human premolars which extracted without any pre-treatment. After all teeth were etched with $37\%$ phosphoric acid gel, metal orthodontic brackets (Q-3002, RMO, USA) were bonded to each tooth using auto-polymerizing orthodontic resin (Ortho-One, Bisco, USA) with the same bonding procedure. The shear bond strength was measured with Instron universal testing machine (model 4466, Instron Ltd., England), and the failure pattern of each bracket was examined with Scanning Electron Microscope (SM 840A, JEOL, Japan). The data were analysed statistically with t-test. The results were as follows : 1. Application of chlorhexidine varnish had no significant effect on the shear bond strength of the orthodontic bracket. 2. There was no significant difference in the failure pattern of orthodontic bracket between the experimental group and the control group.

  • PDF

COMPARISON OF BOND STRENGTH OF A FIBER POST CEMENTED WITH VARIOUS RESIN CEMENTS (다양한 레진시멘트로 합착한 섬유포스트의 결합강도 비교)

  • Lee, Hyun-A;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.499-506
    • /
    • 2008
  • The purpose of this study was to compare the push-out strength of a fiber post cemented with various resin cements. Newly extracted 36 human mandibular premolars which had single root canal were selected and their crown portions were removed. The root canal was instrumented using $PROTAPER^{TM}$ system and obturated using continuous wave technique. In each root, a 9-mm deep post space was prepared. #2 translucent fiber post (DT Light post, Bisco Inc., Schaumburg, IL, U.S.A.) was cemented using injection technique with Uni-dose needle tip (Bisco) and six different resin cements. The tested resin cements were Duo-Link (Bisco Inc., Schaumburg, IL, U.S.A.), Variolink II (Ivoclar-Vivadent AG, Schann, Liechtenstein), Panavia F (Kuraray Medical Inc., Okayama, Japan), Multilink Automix (Ivoclar-Vivadent AG, Schann, Liechtenstein), RelyX Unicem (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and Maxcem (Kerr Co., CA, U.S.A.). After storage in distilled water for 24 hours, each root was transversally sectioned into approximately 1-mm thick sections. This procedure resulted in 6 serial sections per root. Push-out test wasperformed using a universal testing machine (EZ Test, Shimadzu Co.) with a crosshead speed of 1 mm/min. The data were analyzed with one-way ANOVA and Tukey HSD (p=0.05). The push-out strength of the groups which cemented fiber post with Panavia F and Multilink Automix were lower than those of the other groups. But, there were no statistically significant difference among groups at a probability level of 0.05.