• Title/Summary/Keyword: Unit-to-unit

Search Result 26,064, Processing Time 0.062 seconds

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Fundamental Studies for the Production of Korea Ginseng(Panax ginseng)(II) -Study on the Variations and the Correlations of Important Quantitative characters of Korea Ginseng according to Environmental Conditions (우량인삼생산(優良人蔘生産)을 위(爲)한 육종생리학적(育種生理學的) 연구(硏究)(II) -재식위치(栽植位置)에 따르는 인삼(人蔘)의 주요량적(主要量的) 형질(形質)의 변이(變異)와 그 상호간(相互間)의 관계(關係))

  • Choi, B.Y.;Park, J.S.;Kim, Y.R.;Kim, M.K.;Jo, J.S.;Kim, C.S.
    • Korean Journal of Agricultural Science
    • /
    • v.2 no.1
    • /
    • pp.131-142
    • /
    • 1975
  • This study was carried out to define the variations of important quantitative characters and correlations among them accoding to the planted location under the shadow by planting density. The results obtained are summarized as follows; 1. Growth of leaf and stem of 6 rows and 8 rows planting plots was decreased at front and back rows, but that of root was increased at front row and also decreased at back row. However, at 4 rows planting plots, front row was better for the growth of leaf, stem and root. 2. Average root weight of 6 rows planting plot was 34.29g but that of 8 rows planting plot was ]8.20 g. And total weight of root per unit area was increased and quality of ginseng was better in 6 rows planting plot compaired with 8 rows. 3. Variation by planting locations under the shadow was smallest in stem diameter and highest in root length at 8 row planting plot, but at 6 rows planting plot, that was smallest in leaf blade and greatest in stem length. However, in 4 rows plant ing plot, variation of leaf length was smallest and that of root weight biggest. 4. In all Planting densities, root weight was significantly correlated with root diameter and high correlation was recognized between root diameter and stem diameter. 5. Rate of variations of all characters among plant individuals was different by planting location and that of correlations between quantitative Characters too.

  • PDF

Cultural practices of in vitro Tuber of Pinellia ternata(Thunb.) Breit II. Effects of Harvesting Time on Growth, Tuber Size and Yield (기내(器內) 대량(大量) 생산(生産) 반하(半夏) 종구(種球)의 포장(圃場) 재배기술(栽培技術) 연구(硏究) II. 수확시기별(收穫時期別) 생육특성(生育特性), 괴경(塊莖)크기 및 수량(收量))

  • Park, Moon-Soo;Park, Ho-Ki;Kim, Tai-Soo;Jang, Yeong-Seon;Park, Keun-Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.1 no.2
    • /
    • pp.115-119
    • /
    • 1993
  • This study was carried out to determine optimum harvest time of in vitro multiplied tuber Pinellia ternata(Thunb.)Breit from 1990 to 1992. Tuber yield and its related traits were observed with four harvest times. Plant height was 7.2cm at 6 months and 19.3cm at 24 months after planting. The number of tubers per unit area was significantly increased with the passage of growing time after planting$(78\;tubers/m^2)$, those were increased by 2.3 times in 6 months, 5.6 times in 12 months, 13.3 times in 18 months and 20.0 times in 24 months. The tuber sizes(length, width and weight) were highly enlarged during 12 to 18 months after planting compared with before or after this time. There were smaller tubers and lower tuber yields with shorter growing period, while large tubers above 7.1mm and higher yields with longer growing. It was suggested that the optimum harvest time was 18 months after planting, before over wintering rather than next year of spring, 24months after planting.

  • PDF

Analysis on Distribution Characteristics of Mammals in Relation to Altitude in Juwangsan National Park (주왕산국립공원에 서식하는 포유동물의 고도에 따른 분포 특징의 분석)

  • Chung, Chul-Un
    • Journal of Ecology and Environment
    • /
    • v.29 no.6
    • /
    • pp.511-520
    • /
    • 2006
  • The study analyzed the distribution of mammalia per altitude in Gamebong, the highest trail of Juwangsan National Park and confirmed the inhabitation of 22 different species inhabiting in the park. Starting from 200 m to 800 m above the sea level was segmented into 100 m unit. The result of analysis has shown that the Tamias sibiricus is the dominant specie throughout in all segments. Species confirmed to be inhabiting in all segments of research areas were Mustela sibirica, Caproelus pygargus and squirrel. By analyzing the confirmed Field Sign basing from the observation point, it has shown close relations between types of species and population following the increase in altitude (y=-0.0234 + 25.552, $R^2$=0.9296, $F_{0.05}$(1,4)=7.71, p<0.05). However, the result of analysis targeting nine species inhabiting in at least five out of six 100 m segmented units has shown that only two species, Apodemus sgrarius (y=-0.034X+25.2, $R^2$=0.905, $F_{0.05}$(1, 4)=38.169, p<.0.01) and Sciurus vulgaris (y=-0.0154X+ 12.819, $R^2$=0.781, $F_{0.05}$(1, 4)=14.270, p<0.05) were affected by the altitude. Therefore, it is judged that the distribution of species does not follow the altitude variation but follows the food conditions and the structure of habitat. The result of analysis of Box and Whisker Diagram had shown lowest quartile deviation($Q_U-Q_L$) in Nature Restoration Area that is located in $200{\sim}300m$ above the sea level, where hikers are prohibited from entering. In $500{\sim}600m$ above the sea level segment that has similar food environment and trail, it has shown the widest distribution. Further research is required on this segment for the excretion drops of Prionailurus bengalensis, a Grade II class of endangered species, were found on the trails.

Carbon Reduction and Enhancement for Greenspace in Institutional Lands (공공용지 녹지의 탄소저감과 증진방안)

  • Jo, Hyun-Kil;Park, Hye-Mi;Kim, Jin-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.4
    • /
    • pp.1-7
    • /
    • 2020
  • This study quantified annual uptake and storage of carbon by urban greenspace in institutional lands and suggested improvement of greenspace structures to enhance carbon reduction effects. The study selected a total of five study cities including Seoul, Daejeon, Daegu, Chuncheon, and Suncheon, based on areal size and nationwide distribution. Horizontal and vertical greenspace structures were field-surveyed, after institutional greenspace lots were selected using a systematic random sampling method on aerial photographs of the study cities. Annual uptake and storage of carbon by woody plants were computed applying quantitative models of each species developed for urban landscape trees and shrubs. Tree density and stem diameter (at breast height) in institutional lands averaged 1.4±0.1 trees/100 ㎡ and 14.9±0.2 cm across the study cities, respectively. Of the total planted area, the ratio of single-layered planting only with trees, shrubs, or grass was higher than that of multi-layered structures. Annual uptake and storage of carbon per unit area by woody plants averaged 0.65±0.04 t/ha/yr and 7.37±0.47 t/ha, which were lower than those for other greenspace types at home and abroad. This lower carbon reduction was attributed to lower density and smaller size of trees planted in institutional lands studied. Nevertheless, the greenspace in institutional lands annually offset carbon emissions from institutional electricity use by 0.6 (Seoul)~1.9% (Chuncheon). Tree planting in potential planting spaces was estimated to sequester additionally about 18% of the existing annual carbon uptake. Enhancing carbon reduction effects requires active tree planting in the potential spaces, multi-layered/clustered planting composed of the upper trees, middle trees and lower shrubs, planting of tree species with greater carbon uptake capacity, and avoidance of the topiary tree maintenance. This study was focused on finding out greenspace structures and carbon offset levels in institutional lands on which little had been known.

Crop Characteristics of Sweetpotato (Ipomoea batatas L.) Germplasms for Optimizing the Selection of Resources (우수자원 선발을 위한 고구마 유전자원의 주요 특성 평가)

  • Park, Won;Lee, Hyeong-Un;Goh, San;Lee, Im Been;Nam, Sang-Sik;Chung, Mi Nam;Yu, Gyeong-Dan;Hwang, Eom-Ji;Lee, Seungyong;Park, Jin Cheon;Paul, Narayan Chandra;Han, Seon-Kyeong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.64 no.4
    • /
    • pp.441-451
    • /
    • 2019
  • This study was conducted to investigate the crop characteristics of 181 sweetpotato germplasms collected from Korea and overseas. The longest shoot vine length was observed in IT232211 (354.8 cm) and the shortest shoot vine length was observed in IT232185 (32 cm). The maximum numbers of shoot branches and nodes were produced by IT232091 (23.0) and IT232174 (67.8), respectively. Differences in Rapid Visco Analyser profiles were observed for pasting parameters such peak, trough, final, breakdown, and setback viscosities; and pasting temperature. The peak and breakdown viscosities were highest in IT232050 and IT232010, at 338.3 and 207.2 Rapid Visco Unit (RVU), respectively. The trough viscosity was lowest in IT232019 at 103.8 RVU. IT232101 had the highest final viscosity (284.6 RVU), and IT232192 had the highest setback viscosity (81.7 RVU). IT232197 had the highest pasting temperature at 86.8℃, and that of IT232134 was lowest at 72.7℃. To evaluate functional substance content, we analyzed 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging activity and total polyphenol content. The highest frequency proportion of starch was in the 10%-15% range (50.8% of the plants), followed by the 5%-10% range (38.1% of the germplasms). Sugar content ranged from 13.5 to 33.3% (23.2% on average); the highest frequency proportion of sugar was in the 20%-25% range (56.9% of the germplasms), followed by the 25%-30% range (25.4% of the germplasms). The highest frequency proportion of water was in the 70%-80% range (52.5% of the germplasms), followed by the 60%-70% range (44.2% of the germplasms). Our results provide basic data for the selection of useful resources and for the development of new sweetpotato varieties.

Germination and Growth of Oaks (Quercus serrata, Q. mongolica, Q. variabilis) Seedlings by Gradient of Light Intensity and Soil Moisture (광도와 토양수분 구배(勾配)에 따른 참나무류(Quercus Serrata, Q. mongolica, Q. variabilis)치수(稚樹)의 발아 및 성장)

  • Beon Mu-Sup
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.4
    • /
    • pp.183-189
    • /
    • 2000
  • This study was carried out to analyze ecophysiological responses for seedling of Quercus serrata, Quercus mongolica and Quercus variabilis that are the typical species of deciduous broadleaved forests in Korea. And executed experiments in the climatic control room to provide necessary information to ecological forest management and methods of natural regeneration through the analysis of seedling responses. The details of experimental analysis were growth processes of 4 months after seeding that vary with the condition of three light intensity[relative light intensity(RLI) 8%, 20%, 52%] and three soil moisture[water suction(WS) Ψ=100 hPa, Ψ=280 hPa, Ψ=330 hPa] gradient, growth factors after harvesting and the nutrition condition of leaves. The results of this study are followings: 1) Early growth was prosperous after germination for the species which have more weight of acorn. 2) The formation of lammas shoot was favourable with Q. variabilis and Q. mongolica. And the rate of the occurrence was the highest in the RLI 20%, and it was remarkably reduced in the RLI 8%. 3) As the height growth of seedling of all 3 species were greater in the RLI 20% and 8% than that of the RLI 52%, they showed strong shade tolerance. 4) The increase of light intensity promoted the diameter at root collar growth, and development of main and lateral roots with all 3 species. 5) It showed that the increase of light intensity in the experimental radiation condition raised special leaf area weight(mg/cm$^2$) and leaf area productivity(mg/cm$^2$). Consequently, these resulted in the increase of leaf thickness and total dry biomass per the unit area of leaf. 6) As the increase of light intensity, the minerals contents of leaves such as N, P and K were lowered, and the increase of soil moisture resulted in the increase of P, K, Ca and Mg.

  • PDF

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

Changes of Hemodynamic and Central Pulmonary Artery Dimension After Bidirectional Cavopulmonarv Shunt (양방향성 체정맥-폐동맥 단락술후 혈역학 및 중심 폐동맥 크기의 변화)

  • 이정렬;이해원
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1306-1315
    • /
    • 1996
  • This study reviewed the changes of hemodynamlcs and centrAl pulmonary artery dimension in 54 patients who underwent bidirectional cavopulmonary shunt(BCPS) between February 1992 and December 1995 at Seoul National University Childrell's Hospital. Ag and body weight of patients averaged 36.8 $\pm$ 37.7 months and 8.0$\pm$3.0 kg, respectively Eightynine percent of patients had more than 2 violations of the risk factors for Fontan operation, resulting overall hospital mortality of 16.6%(9154). Serial hemodynamic and anglographic examinations before and mean 16.3 $\pm$ 14.3 months iirter BCPS were compared. The arterial oxygen saturation improved from a preoperative value of 71 9: 10.1 % to 79.H $\pm$ 8. 5% (n:4), p<0.05). The values of arterial oxygen saturation were lower as the age of the patients with BCPS in place was older(n=22, R'=0.341, p=0.004). A mean pulmonary artery pressure and pulmonary vascular resistance reduced from 31 $\pm$17 to 1).5$\pm$3.SmmHg(n=22, p<0.05) and from ).2$\pm$2.1 to 2.3$\pm$2.7 unit (n=7. p>0.05), respectively. Follow-up study showed a significant Increase of absolute values of ipsilateral pulmoanry artery (n: 14, p<0.05), but no change of contralateral pulmonary artreries (n: 14. p=not significant(HSI). However, there w re significant decreases in diameters of both ipsilateral and contralateral pulmonary arteries standardized by patients' body surface areas(16.8% decrease, n: 14, p< 0. 05 for ipsilatreal, 25.1%, n=14, p<0.05 for contralateral). Pulmonary artery indices for cross sectional areas of both pulmonary arterises decreased 9.3 $\pm$ 13.8% with showing a trend of more decrease as the follow-up duration was longer, We conclude that the bidirectional cavopulmonary shunt provide an excellent.

  • PDF

Pharmaco-mechanical Thrombectomy and Stent Placement in Patients with May-Thurner Syndrome and Lower Extremity Deep Venous Thrombosis (May-Thurner 증후군과 동반된 하지 심부정맥혈전환자에서 혈전제거술과 스텐트삽입술)

  • Jeon, Yonh-Sun;Kim, Yong-Sam;Cho, Jung-Soo;Yoon, Yong-Han;Baek, Wan-Ki;Kim, Kwang-Ho;Kim, Joung-Taek
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.757-762
    • /
    • 2009
  • Background: Compression of the left common iliac vein by the overriding common iliac artery is frequently combined with acute deep vein thrombosis in patients with May-Thurner Syndrome. We evaluate the results of treatment with thrombolysis and thrombectomy followed by stenting in 34 patients with May-Thurner Syndrome combined with lower extremity deep venous thrombosis. Material and Method: The authors retrospectively reviewed the records of 34 patients (mean age: $65{\pm}14$ year old) who had undergone stent insertion for acute deep vein thrombosis that was caused by May-Thurner syndrome. After thrombectomy and thrombolysis, insertion of a wall stent and balloon angioplasty were performed to relieve the compression of the left common iliac vein. Urokinase at a rate of 80,000 to 120,000 U/hour was infused into the thrombosed vein via a multi-side hole thrombolysis catheter. A retrieval inferior vena cava (IVC) filter was placed to protect against pulmonary embolism in 30 patients (88%). Oral anticoagulation with warfarin was maintained for 3 months, and follow-up Multi Detector Computerized Tomography (MDCT) angiography was done at the date of the patients' hospital discharge and at the 6 months follow-up. Result: The symptoms of deep venous thrombosis disappeared in two patients (4%), and there was clinical improvement within 48 hours in twenty eight patients (82%), but there was no improvement in four patients (8%). The MDCT angiography at discharge showed no thrombus in 9 patients (26%) and partial thrombus in 21 (62%), whereas the follow-up MDCT at $6.4{\pm}5.5$ months (32 patients) revealed no thrombus in 23 patients (72%), and partial thrombus in 9 patients (26%). Two patients (6%) had recurrence of DVT, so they underwent retreatment. Conclusion: Stent insertion with catheter-directed thrombolysis and thrombectomy is an effective treatment for May-Thurner syndrome combined with acute deep vein thrombosis in the lower extremity.