• Title/Summary/Keyword: Unit Water

Search Result 2,770, Processing Time 0.023 seconds

A Study on the status of unit water content control of the Ready-Mixed Concrete plants in the country (국내 레미콘 플랜트의 단위수량관리 현황 검토에 관한 연구)

  • Jung, Yang-Hee;Kim, Yong-Ro;Choi, Il-Ho;Lee, Do-Bum;Hong, Kyung-Seon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.606-609
    • /
    • 2006
  • In this study, it was selected that in order to make an investigation into the status of the unit water content control of the ready-mixed concrete plants in the country, Capacitance Measurement Method out of various methods which are able to gauge the amount of unit water content in fresh concrete. Then, it were estimated that the quantity of unit water in fresh concrete and the technical standard of every mixture design of the six ready-mixed concrete plants chosen at random in the country. Finally, based on this study, it was proposed as fundamental data to utilize measurement techniques of the quantity of unit water for the quality control of the ready-mixed concrete in construction field.

  • PDF

A Study on Influencing Factors of Unit-Water Measurement method according to Electrostatic capacity (정전용량에 따른 단위수량 측정기법의 영향인자에 대한 실험적 연구)

  • We, Joon-Woo;Lee, Young-Jin;Kim, Jeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.232-233
    • /
    • 2013
  • The unit-water content in fresh concrete determines consistency, and play an important role in condensing the structure of concrete and enhancing the durability of concrete. The capacitance measurement method measure quickly unit-water content and is the best way to apply to construction site. In this study, the unit-water content of capacitance measurement method is estimated according to types and replacemment ratio of admixture. and the field application of capacitance measurement method is reviewed.

  • PDF

An Experimental Study on the Evaluation of Unit-Water Content in Mortar Using High Frequency Moisture Sensor (고주파 수분 센서를 이용한 모르타르의 단위수량 평가에 관한 실험적 연구)

  • Cho, Yang-Je;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.17-18
    • /
    • 2021
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

An Fundamental Study on the Measurement of Cement Mortar Unit-Water Content Using High Frequency Moisture Sensor (고주파 수분 센서를 이용한 시멘트 모르타르의 단위수량 측정에 관한 기초적 연구)

  • Cho, Yang-Je;Kim, Min-Seo;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.6-7
    • /
    • 2020
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

The evaluation of the simultaneous flow rate for sizing the water supply piping in the office building (사무소 건물의 급수배관경 산정을 위한 동시사용유량에 관한 연구)

  • 이용화
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.511-517
    • /
    • 1999
  • Determining the simultaneous flow rate in any particular section of piping is the important step in order to determine the size of water supply piping. Now we are using the diversity curve of common water closet in order to determine the simultaneous flow rate of water supply piping, but there is a difference between a determined flow rate of general water closet and that of water closet for water saving. This study aims to find out the fixture unit of a flush valve type water closet for water saving in office building, and to determine the correlation between the fixture units and peak flow rates on the basis of the probability theory. A flush valve type water closet for water saving that have a 7.5 second duration of flush operation with an average design flow rate 72 $\ell$/fin was considered. Simulation results indicate that the number 5 is shown to be reasonable to the fixture unit of water closet for water saving. And the design can be undersized considerably with the revised diversity curves using modified fixture unit.

  • PDF

Relationship between the Flow data on the Unit Watersheds and on the Stream Flow Monitoring Network (수질오염총량관리 단위유역 유량자료와 하천유량 측정망 자료의 연계성 분석)

  • Park, Jun Dae;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.55-65
    • /
    • 2013
  • It is very difficult to apply stream flow data directly to the management of Total Maximum Daily Loads because there are some differences between the unit watershed and the stream flow monitoring network in their characteristics such as monitoring locations and its intervals. Flow duration curve can be developed by linking the daily flow data of stream monitoring network to 8 day interval flow data of the unit watershed. This study investigated the current operating conditions of the stream flow monitoring network and the flow relationships between the unit watershed and the stream flow monitoring network. Criteria such as missing and zero value data, and correlation coefficients were applied to select the stream flow reference sites. The reference sites were selected in 112 areas out of 142 unit watersheds in 4 river basins, where the stream flow observations were carried out in relatively normal operating conditions. These reference sites could be utilized in various ways such as flow variation analysis, flow duration curve development and so on for the management of Total Maximum Daily Loads.

An Experimental Study on the Evaluation of Mortat Unit-Water Content by Powder Ratio Using Frequency Domain Reflectometry Sensor (고주파수분센서를 활용한 분체 비율별 모르타르 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Wi, Kwang-Woo;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.109-110
    • /
    • 2022
  • Currently, interest in the quality of concrete is increasing. Among the important factors for evaluating the quality of concrete, interest in unit-water content is also increasing. Currently, the air-meter method, the microwave oven drying method, the capacitance method, and the microwave penetration method are used to measure the unit-water content of concrete.. Among the above methods, except for the microwave method, the measurement method is complicated, portability is reduced, and economic efficiency is reduced. This research aims to measure a unit-water content by using a Frequency Domain Reflectometry(FDR) sensor that is economical, simple to measure, and portable among microwave methods. In addition, it is an experimental study to determine the accuracy of unit-water content using a single input residual model during deep learning to solve the limitations of the FDR sensor.

  • PDF

A Study on the Evaluation of Concrete Unit-Water Content of FDR Sensor Using Deep Learning and Machine Learning (딥러닝과 머신러닝을 이용한 FDR 센서의 콘크리트 단위수량 평가에 관한 연구)

  • Lee, Seung-Yeop;Youn, Ji-Won;Wi, Gwang-Woo;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.29-30
    • /
    • 2022
  • The unit-water content has a very significant effect on the durability of the construction structure and the quality of concrete. Although there are various methods for measuring the unit-water content, there are problems of time required for measurement, precision, and reproducibility. Recently, there is an FDR sensor capable of measuring moisture content in real time through an apparent dielectric constant change of electromagnetic waves. In addition, various artificial intelligence techniques that can non-linearly supplement the accuracy of FDR sensors are being studied. In this study, the accuracy of unit-water content measurement was compared and evaluated using machine learning and deep learning techniques after normalizing the data secured in concrete using frequency domain reflectometry (FDR) sensors used to measure soil moisture at home and abroad. The result of comparing the accuracy of machine learning and deep learning is judged to be excellent in the accuracy of deep learning, which can well express the nonlinear relationship between FDR sensor data and concrete unit-water content.

  • PDF

Water Quality Status of the Unit Watersheds in the Yeongsang / Seomjin River Basin since the Management of Total Maximum Daily Loads (수질오염총량관리제 시행에 따른 영산강.섬진강수계 단위유역의 수질 현황)

  • Park, Jae Hong;Rhew, Doug Hee;Jung, Dong Il
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.719-728
    • /
    • 2011
  • The results of investigation on the water quality of the unit watersheds in the Yeongsang/Seomjin River indicate that $BOD_5$, SS, T-P decrease in most of the unit watersheds. However, $COD_{Mn}$ and T-N increase since the Total Maximum Daily Loads (TMDLs). It is thought that $COD_{Mn}$, which is included non-biodegradable matters, is difficult to decrease only using by conventional biological treatment facilities and T-N is affected by non-point source, etc. The results of assessment on 3 years $BOD_5$ indicate that most of the unit watersheds were being improved except Yeongbon A, Seombon C and Yocheon B. In addition, it was found that T-P were also being improved except Yocheon B and Hwangryeong A. Consequently, water qualities of the unit watersheds have been improved in many cases since the TMDLs.

An Experimental Study on the Accuracy of Concrete Unit-Water Content Using High-frequency Water Fraction Sensors (고주파수분센서를 이용한 콘크리트 단위수량 평가 정확도에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Yu, Seung-Hwan;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.61-62
    • /
    • 2022
  • The unit quantity is an important factor influencing the durability, workability, and quality of concrete. Methods for measuring the unit quantity include a high frequency heating method, a unit volume mass method, a capacitance method, and a microwave method. However, these methods have disadvantages of poor measurement method, time required, and accuracy, and a relatively experimental method compensating for these disadvantages was used to measure the unit quantity using a high frequency main sensor (FDR) capable of simple and fast measurement. In addition, the unit quantity was evaluated by analyzing the measurement data through deep learning.

  • PDF