• 제목/요약/키워드: Unit Volume

검색결과 1,250건 처리시간 0.028초

A CLASS OF COMPLETELY MONOTONIC FUNCTIONS INVOLVING DIVIDED DIFFERENCES OF THE PSI AND TRI-GAMMA FUNCTIONS AND SOME APPLICATIONS

  • Guo, Bai-Ni;Qi, Feng
    • 대한수학회지
    • /
    • 제48권3호
    • /
    • pp.655-667
    • /
    • 2011
  • A class of functions involving divided differences of the psi and tri-gamma functions and originating from Kershaw's double inequality are proved to be completely monotonic. As applications of these results, the monotonicity and convexity of a function involving the ratio of two gamma functions and originating from the establishment of the best upper and lower bounds in Kershaw's double inequality are derived, two sharp double inequalities involving ratios of double factorials are recovered, the probability integral or error function is estimated, a double inequality for ratio of the volumes of the unit balls in $\mathbb{R}^{n-1}$ and $\mathbb{R}^n$ respectively is deduced, and a symmetrical upper and lower bounds for the gamma function in terms of the psi function is generalized.

하프 브릿지 푸쉬 풀 DC/DC 컨버트를 이용한 전자석 전원 개발 (Development of Magnet Power Supply using Half Bridge Push Pull DC/DC Converter)

  • 김성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2030-2032
    • /
    • 1998
  • It is always necessary to high performance power supplies for the magnet system in the accelerator, especially when the number of power supplies are large. When have developed the compact power supply using switching technology instead of SCR phase control. We adopt the pulse width modulation(PWM) method with a half bridge DC/DC converter. In this way, we can make a compact system with light weight and small volume. Actual system we developed is 1.2kW, 35V/35A bipolar DC power supply current precision of +/-0.02%. It is possible to mount 10 unit in a conventional 19 rack. The built in controller has an RS422 protocol to drive 10 unit by one serial port up to 1.2km distance. If we adopt RS485 protocol, one serial port can control 32 power supplies. In this paper, we will report the design and performance of the prototype power supply.

  • PDF

Determination of Optimum Pressurizer Level for Kori Unit 1

  • Song, Dong-Soo;Lee, Chang-Sup;Lee, Jae-Yong;Kim, Yo-Han;Lee, Dong-Hyuk
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.437-442
    • /
    • 1997
  • To determine the optimum pressurizer water level during normal operation for Kori unit 1, performance and safety analysis are peformed. The methodology is developed by evaluating "decrease in secondary heat removal" events such as Loss of Normal Feedwater accident. To demonstrate optimum pressurizer level setpoint, RETRAN-03 code is used for performance analysis. Analysis results of RETRAN following reactor trip are compared with the actual plant data to justify RETRAN code modelling, The results of performance and safety analyses show that the newly established level setpoints not only improve the performance of pressurizer during transient including reactor trip but also meet the design bases of the pressurizer volume and pressure. pressure.

  • PDF

생물공학에서의 합성막 : 현실과 가능성 (Synthetic Membranes in Biotechnology: Realities and Possibilities)

  • Belfort, Georges
    • 멤브레인
    • /
    • 제2권2호
    • /
    • pp.91-103
    • /
    • 1992
  • Synthetic membrane processes are being increasingly integrated into existing reaction, isolation, and recovery schemes for the production of valuable biological molecules. In many cases they are replacing traditional unit processes. The properties of membrane systems which are most often exploited for both upstream and downstream processing and their permselectivity, high surface area per unit volume, are their potential for controlling the level of contact and/or mixing between two separate phases. Advances in both membrane materials and module design and operation have led to better control of concentration polarization and membrane fouling. After presenting some recent advances in membrane materials and fluid mechanics, we demonstrate how membranes have been integrated into cellular and enzymatic reaction schemes. This is followed by a review of established and emerging synergism between biological processes and synthetic membranes.

  • PDF

Synthetic membranes in Biotechnology: Realities and Possibilities

  • Belfort, Georges
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1992년도 추계 총회 및 학술발표회
    • /
    • pp.15-33
    • /
    • 1992
  • Synthetic membrane processes are being increasingly integrated into existing reaction, isolation, and recovery schemes for the production of valuable biological molecules. In many cases they are replacing traditional unit processes. The properties of membrane systems which are most often exploited for both upstream and downstream processing are their permselectivity, high surface area per unit volume, and their potential for controlling the level of contact and/or mixing between two separate phases. Advances in both membrane materials and module design and operation have led to better control of concentration polarization and membrane fouling. After presenting some recent advances in membrane materials and fluid mechanics, we demonstrate how membranes have been integrated into cellular and enzymatic reaction schemes. This is followed by a review of established and emerging membrane separation processes. Several examples are used to emphasize the synergism between biological processes and synthetic membranes.

수송단위에 의한 지연납기를 고려한 최적 수송량 결정 모형 (An Optimal Distribution Model under Consideration of Delivery Unit and Backlogging Costs)

  • 이양호;안준홍;최경현
    • 대한산업공학회지
    • /
    • 제29권3호
    • /
    • pp.206-212
    • /
    • 2003
  • In this paper, we propose a mathematical optimization model with a suitable algorithm to determine delivery and backlogging quantities by minimizing the total cost including the penalty costs for delay. The system has fixed transshipment costs and demands are fulfilled by some delivery units that represent the volume of delivery amount to be shipped in a single time period. Since, backlogging is allowed, demands could be delivered later at the expense of some penalty costs. The model provides the optimal decisions on when and how much to he delivered while minimizing the total costs. To solve the problem, we propose an algorithm that uses the Lagrangian dual in conjunction with some primal heuristic techniques that exploit the special structure of the problem. Finally, we present some computational test results along with comments on the further study.

신경계 중환자실에서 기계호흡 그래프 파형 감시와 분석 (Monitoring and Interpretation of Mechanical Ventilator Waveform in the Neuro-Intensive Care Unit)

  • 박진
    • 대한신경집중치료학회지
    • /
    • 제11권2호
    • /
    • pp.63-70
    • /
    • 2018
  • Management of mechanical ventilation is essential for patients with neuro-critical illnesses who may also have impairment of airways, lungs, respiratory muscles, and respiratory drive. However, balancing the approach to mechanical ventilation in the intensive care unit (ICU) with the need to prevent additional lung and brain injury, is challenging to intensivists. Lung protective ventilation strategies should be modified and applied to neuro-critically ill patients to maintain normocapnia and proper positive end expiratory pressure in the setting of neurological closed monitoring. Understanding the various parameters and graphic waveforms of the mechanical ventilator can provide information about the respiratory target, including appropriate tidal volume, airway pressure, and synchrony between patient and ventilator, especially in patients with neurological dysfunction due to irregularity of spontaneous respiration. Several types of asynchrony occur during mechanical ventilation, including trigger, flow, and termination asynchrony. This review aims to present the basic interpretation of mechanical ventilator waveforms and utilization of waveforms in various clinical situations in the neuro-ICU.

Correlation between Structures and Ionic Conductivities of $Na_2Ln_2Ti_3O_{10}$ (Ln=La, Nd, Sm, and Gd)

  • 박길응;변송호
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권2호
    • /
    • pp.168-172
    • /
    • 1996
  • The variations of the structural detail of layered perovskite-type oxides, Na2Ln2Ti3O10 (Ln=La, Nd, Sm, Gd), have been refined by Rietveld analyses of their powder X-ray diffraction data. Although the c-axis strongly decreases from Ln=La to Nd, Sm, or Gd, the length of Na-O bond along the c-axis that is regarded as the sodium layer spacing is not dependent on the unit cell parameter. Such a behavior is explained by the fact that Na-O bond is in competition with Ti-O one of the perovskite slab. Increased covalency of this Ti-O bond by the lattice contraction leads to weakening of the attaching strength of Na ion. This picture is consistent with the experimental observation that Na ion conductivity of Na2Ln2Ti3O10 increases from Ln=La to Nd, Sm, or Gd despite strong contraction of the unit cell volume.

Mechanical properties and radiation shielding performance in concrete with electric arc furnace oxidizing slag aggregate

  • Lim, Hee Seob;Lee, Han Seung;Kwon, Seung Jun
    • Journal of Ceramic Processing Research
    • /
    • 제20권4호
    • /
    • pp.363-371
    • /
    • 2019
  • In this study, physical properties of normal concrete, magnetite concrete, EAF concrete, and EAF concrete with added iron powder were evaluated and a feasibility of radiation shielding is also evaluated through irradiation tests against X-rays and gamma-rays. While the unit weight of EAF concrete (3.21 t/㎥) appeared lower than that of magnetite concrete (3.50 t/㎥), the results in compressive strength of EAF concrete were greater than those in magnetite and normal concrete. While the radiation transmission rate of normal concrete reaches 26.0% in the X-ray irradiation test, only 6.0% and 9.0% of transmission rate were observed in magnetite concrete and linear relationship with unit volume weight and radiation shielding. In the gamma-ray irradiation test, the performance of EAF and magnetite concretes appeared to be similar. Through the results on the excellent physical properties and radiation shielding performance a potential applicability of EAF concrete to radiation shielding was verified.

Lymphaticovenular Anastomosis: Superficial Venous Anatomical Approach

  • Winaikosol, Kengkart;Surakunprapha, Palakorn
    • Archives of Plastic Surgery
    • /
    • 제49권5호
    • /
    • pp.689-695
    • /
    • 2022
  • Background Lymphaticovenular anastomosis (LVA) is an effective, functional treatment for limb lymphedema. This study reports an alternative surgical approach to lymphedema treatment without the use of indocyanine green mapping. Methods A retrospective analysis was performed on 29 consecutive lymphedema patients who underwent LVAs from January 2015 to December 2020, whereby incisions were made along the anatomy of the superficial venous systems in both upper and lower extremities around the joint areas. The evaluation included qualitative assessments and quantitative volumetric analyses. Result The mean number of anastomoses was 3.07, and the operative time was 159.55 minutes. Symptom improvement was recorded in 86.21% of the patients, with a mean volume reduction of 32.39%. The lymphangitis episodes decreased from 55.17% before surgery to 13.79% after surgery, and the median number of lymphangitis episodes per year decreased from 1 before surgery to 0 after surgery. Conclusions The superficial venous anatomical approach is an easy way to start a lymphedema practice using LVA without other advanced surgical equipment. With this reliable technique, microsurgeons can perform LVA procedures and achieve good results.