• 제목/요약/키워드: Unit Module

검색결과 831건 처리시간 0.036초

라그랑지승수 수정에 의한 효율적인 동적부하배분 알고리즘 (An efficient dynamic load dispatch algorithm with Lagrange multipliers adjustment)

  • 송길영;오광희;김용하
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.467-473
    • /
    • 1996
  • This Paper presents a new algorithm to solve Dynamic Economic Dispatch problem. Proposed algorithm is composed of two computational modules; one is dispatch, the other adjusting module. In the dispatch module based on the traditional Static Economic Dispatch method, the power dispatch of each unit is calculated. And in case the results of dispatch module violate ramp rate constraints, Lagrange multipliers are adjusted in the adjusting module. Tests and computer results on test systems are given to show the efficiency of the proposed algorithm. (author). 11 refs., 6 figs., 4 tabs.

  • PDF

이동 통신 단말용 센서 시스템을 위한 신호 잠금 방식의 검출 회로 (Signal lock-in detection circuit for mobile device sensor systems)

  • 정인일;손호현;최영환
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2008년도 정보통신설비 학술대회
    • /
    • pp.559-562
    • /
    • 2008
  • In this paper we propose a lock-in detection method for portable sensor systems and demonstrate with the portable detection module that has high sensitivity and robustness against the noise. The simple portable sensor module is manufactured using MCU(Micro Contorl Unit), OPAMP, MOSFET and a pair of infrared sensor. Manufactured sensor module is testified in the noisy environment caused by an external light and an white noise source. Without any type of band pass filters, we recover a signal of 33 $mV_{p-p}$ in 80 $mV_{p-p}$ white noise and get the DR(Dynamic Reserve) of 14 dB.

  • PDF

소프트스킬 프로그램 학습성과의 교과기반 평가(CEA)를 위한 학습모듈(안)에 관한 연구 (A Study on Learning Modules for Course Embedded Assessment of Soft Skills Program Outcomes)

  • 강상희
    • 공학교육연구
    • /
    • 제23권6호
    • /
    • pp.40-50
    • /
    • 2020
  • This paper proposes learning modules as a kind of integrated instruction model for soft skills program outcomes to enable CEA. Learning modules consist of course learning objectives(outcomes) described in detail, learning content(elements), learning activities(teaching learning methods), evaluation methods, evaluation rubrics so that they can be evaluated based on the performance criteria of the program learning outcomes. The unit of time for the learning module is 50 minutes. If this learning module is applied, it is expected that the soft skill program outcomes can be evaluated in the technical course. As a result of the expert feasibility study, the positive answers were much higher than the negative answers in most of the questions about the composition of the learning module or the method of managing the class.

유닛모듈러 공법의 시공매뉴얼 체계 개발 (Development of manual framework for unit modular construction method)

  • 김균태;김태영;전영훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.198-199
    • /
    • 2015
  • In Korea, it raised the need of the specification of unit modular construction, because there are no standard or manual. And it is urgent that the specification of unit modular construction is needed to develop in the domestic. Therefore, this study aims to propose the manual framework of the construction method. In the future, this framework will be based on the development of the manual on the unit modular construction method.

  • PDF

Expert Network의 모듈형 계층구조를 이용한 범용 연산회로 설계 (General Purpose Operation Unit Using Modular Hierarchical Structure of Expert Network)

  • 양정모;홍광진;조현찬;서재용;전홍태
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 추계 학술대회 학술발표 논문집
    • /
    • pp.122-125
    • /
    • 2003
  • By advent of NNC(Neural Network Chip), it is possible that process in parallel and discern the importance of signal with learning oneself by experience in external signal. So, the design of general purpose operation unit using VHDL(VHSIC Hardware Description Language) on the existing FPGA(Field Programmable Gate Array) can replaced EN(Expert Network) and learning algorithm. Also, neural network operation unit is possible various operation using learning of NN(Neural Network). This paper present general purpose operation unit using hierarchical structure of EN EN of presented structure learn from logical gate which constitute a operation unit, it relocated several layer The overall structure is hierarchical using a module, it has generality more than FPGA operation unit.

  • PDF

반도체 설비의 Fan Filter Unit 에서 발생하는 진동이 Wafer 생산성에 미치는 영향

  • 조귀영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.121-121
    • /
    • 2014
  • 본 연구에서는 반도체 제조의 Diffusion 공정설비의 FFU (Fan Filter Unit) 진동에 의해 발생한 wafer 불량 현상을 규명 및 개선하였다. EFEM(Equipment Front End Module)의 Loading 부에 장착된 FOUP(Front Opening Unified Pod)에 들어 있는 Wafer 들이 설비 EFEM 하부로 떨어져 깨지거나 FOUP 내에서 겹침 현상이 발생하는 것을 확인하였다. 이에 생산현장의 모든 Diffusion 공정 설비를 조사하였으며, 그 결과 A 사(社)의 특정 설비에서만 발생되는 현상임을 확인하였다. 해당 A사(社)설비군에서만 월 평균 10 건의 Slot Mapping Error 가 발생하였으며, 이로 인해 Wafer가 재 제조된 매수가 월 평균 53 매로 확인되었다. 따라서 본 연구는 A 사(社)설비에서 발생하는 Mapping Error 의 원인 규명 및 개선을 위해 추진되었다. 총 12 개의 항목을 불량 발생 원인 후보 군으로 선정 후 예비 진단한 결과 FFU(Fan Filter Unit)에 의한 문제 발생 가능성이 가장 높을 것으로 추정되었다. 이에 따라 4 개의 서로 다른 물리적 환경/조건에서 진동을 측정하였으며, 최종 평가 결과 Motor 와 Blade 의 불균형에서 기인한 진동이 설비의 loader 부에 직접적으로 영향을 주는 것을 확인하였다. 진동 문제를 해결하기 위해 고 RPM blade 에서 저 RPM 및 유량 감소를 보완할 수 있는 신규모델로 교체하였다. 신규 Module(blade/motor) 장착 후 Load port 에서의 진동 측정 결과 개선 전 대비 91% 감소하였으며, 결과적으로 Slot mapping error 발생 건수가 50% 이상 감소되는 효과와 Wafer 재 제조 매수도 월 평균 약 43% 감소하는 효과를 얻을 수 있었다.

  • PDF

Shingled 모듈 적용을 위한 태양전지 전극 구조 최적화 (Optimization of Solar Cell Electrode Structure for Shingled Module)

  • 오원제;박지수;황수현;이수호;정채환;이재형
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.290-294
    • /
    • 2018
  • The shingled photovoltaic module can be produced by joining divided solar cells into a string of busbarless structure and arranging them in series and parallel to produce a module, in order to produce a high output per unit area. This paper reports a study to optimize solar cell electrode structure for shingled photovoltaic module fabrication. The characteristics of each electrode structure were analyzed according to the simulation program as follow: 80.62% fill factor in the six-junction solar cell electrode structure and 19.23% efficiency in the five-junction electrode structure. Therefore, the split electrode structure optimized for high-density and high-output shingled module fabrication is the five-junction solar cell electrode structure.