• 제목/요약/키워드: Unit Load Method

Search Result 511, Processing Time 0.028 seconds

Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth (Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철)

  • Yoon, Hyung-In
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

Shifting Control Method for Automatic Transmission of PSD-Axle Forklift (PSD322-Axle형 지게차 자동변속기의 변속제어)

  • Kwon, Soon-Ki;Choi, Si-Young;Kwon, Gi-Ryung;Han, Seung-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.565-575
    • /
    • 2009
  • A forklift (also called a lift truck) is a powered industrial truck that is used to lift and transport materials. It has become an indispensable piece of equipment in manufacturing and warehousing operations. The modem forklift is equipped with automatic transmission to meet the requirement of loading and easy operation of the vehicle. This paper proposes the design of TECU(Transmission Electronic Control Unit) which is applied to PSD322-Axle transmission. Garofalo's control technique is generally used to the automatic transmission. We consider the work quality and market requirement that does not want to control engine throttle. This paper proposes new controller system which guarantees efficient speed changes with simple system. This new system does not control the engine throttle spontaneously. But it has the load of engine and vehicle as a maximum disturbance. The scope of the disturbance is limited to the stoll area of the torque converter. This paper proposes a ideal control commander that converges relative velocity of the input and ouput of a clutch into a zero. We design linear controller to execute the idea control commander. We applied the control algorithm to the forklift of PSD322-Axle type and the performance of this controller was verified.

  • PDF

Emotional Labour, Emotional Expression and Burnout of Clinical Nurses (임상간호사의 정서노동, 정서표현과 소진)

  • Park, Hyun-Joo
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.15 no.2
    • /
    • pp.225-232
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate the relationship among emotional labour, emotional expression and burnout of clinical nurse. Method: Data was collected from convenient sample of 178 nurses in 4 cities. The questionnaire measured the level of emotional labour, emotional expression and burnout of clinical nurse. The data were analyzed using descriptive statistics, t-test, ANOVA, and Pearson's correlation coefficient. Result: The mean score of emotional labour was 3.34(${\pm}.41$), emotional expression was 3.49(${\pm}.51$), burnout was 2.94(${\pm}.58$). There were significant differences on burnout according to age, marital status, religion, clinical career, working unit, level of job satisfaction, satisfaction of work load, satisfaction of interpersonal relations. There was a significant positive correlation between emotional labour and emotional expression. The emotional expression was a significant negative correlation with burnout. Conclusions: From the studies reviewed, it can expect the positive effect to decrease the burnout of clinical nurses when the nurse administrators who have concern about nurses' emotional expression. These findings would be significant resource to promote understanding about emotional labour for nurses.

  • PDF

A Field Application Case of Direct Ice Slurry Transporting System for District Cooling (지역냉방용 직접순환식 아이스슬러리 시스템의 현장적용 사례)

  • Yoo, Ho-Seon;Lee, Sang-Hoon;Lee, Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.496-504
    • /
    • 2009
  • In order to investigate the feasibility of a direct ice slurry transporting system for the purpose of district cooling, a case study of field application is performed. The research aims include the field measurement of ice packing factor, the performance of coldness delivery, and the branching characteristics of ice slurry. Two representative types of pipe branch are dealt with in this work. For the slurry flow with ice volume fraction of 0.16 or less, the pipe blocking due to aggregation is not observed. Based on the time-wise variation of temperature in the storage tank, a calculating method of ice packing factor is newly developed, which seems to be useful when the brine concentration is unknown. It is confirmed that the mass flow rate of ice slurry per unit cooling load is markedly reduced with increasing the ice content. The pumping power also decreases, but remains unchanged for high ice fractions. The distribution of ice particle before and after branching shows a good uniformity within the range of 5% difference, but yields a unique trend depending on the flow rate.

Data Management Method of Table Unit for Efficient Load in a Spatial Data Warehouse Builder (공간 데이터 웨어하우스 구축기에서 추출된 데이터의 효율적인 적재를 위한 테이블 단위의 데이터 관리 기법)

  • Kim, Hyung-Sun;You, Byeong-Seob;Park, Soon-Young;Lee, Jae-Dong;Bae, Hae-Young
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.79-81
    • /
    • 2005
  • 공간 데이터 웨어하우스 구축기는 운영 데이터베이스의 데이터를 추출하여, 공간 데이터 웨어하우스 서버에 적재하는 과정을 효율적으로 관리하는 시스템이다. 구축기는 적재로 인한 서버의 부하를 줄이기 위하여 적재할 데이터를 임시 저장하는데, 기존 기법은 적재할 데이터를 하나의 저장 공간에 관리한다. 따라서 서버가 특정 차원 테이블에 대한 실시간 질의처리를 위해 특정 차원 테이블의 즉시 적재를 요청할 경우, 구축기는 이를 위해 임시 저장한 모든 데이터를 검색하므로 처리비용이 증가한다. 또한, 하나의 저장공간에 적재할 데이터를 유지하여 서버에 데이터 적재 시, 저장을 위해 혼합된 데이터를 분석하는 비용이 증가한다. 본 논문에서는 공간 데이터 웨어하우스 구축기에서 추출된 데이터의 효율적인 적재를 위한 테이블 단위의 데이터 관리 기법을 제안한다. 제안 기법은 운영 데이터베이스로부터 추출한 데이터를 서버에 적재할 차원 테이블 단위로 구축기에서 각각 다른 저장 공간에 관리한다. 따라서 테이블 단위의 데이터 관리로 실시간 질의처리를 위한 특정 차원 테이블의 즉시 적재 비용이 감소하며, 테이블 단위의 병렬전송이 가능하여 전송비용이 감소한다. 또한, 서버로 전송된 데이터는 테이블 단위의 벌크 삽입이 가능하여 적재시간이 감소한다.

  • PDF

Prediction of Iron Loss Resistance by Using HILS System (HILS 시스템을 통한 IPMSM의 철손저항 추정)

  • Jeong, Kiyun;Kang, Raecheong;Lee, Hyeongcheol
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.1
    • /
    • pp.25-33
    • /
    • 2015
  • This paper presents the d-q axis equivalent circuit model of an interior permanent magnet (IPM) which includes the iron loss resistance. The model is implemented to be able to run in real-time on the FPGA-based HIL simulator. Power electronic devices are removed from the motor control unit (MCU) and a separated controller is interfaced with the real-time simulated motor drive through a set of proper inputs and outputs. The inputs signals of the HIL simulation are the gate driver signals generated from the controller, and the outputs are the winding currents and resolver signals. This paper especially presents iron loss prediction which is introduced by means of comparing the torque calculated from d-q axis currents and the desired torque; and minimizing the torque difference. This prediction method has stable prediction algorithm to reduce torque difference at specific speed and load. Simulation results demonstrate the feasibility and effectiveness of the proposed methods.

The Estimation of Fatigue Strength of Structure with Practical Dynamic Force by Inverse Problem and Lethargy Coefficient (구조물의 피로강도평가를 위한 역문제 및 무기력계수에 의한 실동하중해석)

  • 양성모;송준혁;강희용;노홍길
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.106-113
    • /
    • 2004
  • Most of mechanical structures are composed of many substructures connected to one another by various types of mechanical joints. In automotive engineering, it is important to study these connected structures under various dynamic forces for the evaluations of fatigue life and stress concentration exactly. In this study, the dynamic response of vehicle structure to external forces is classified an inverse problem involving strains from the experiment and the analysis. The practical dynamic forces are determined by the combination of the analytical and experimental method with analyzed strain by quasi-static finite element analysis under unit force and with measured strain by a strain gage under driving load, respectively. In a stressed body, inter-molecular chemical bonds are failed beyond the certain magnitude. The failure of molecular structure in material is considered as a time process of which rate is determined by mechanical stress. That is, the failure of inter-molecular chemical bonds is the fatigue lift of material. This kinetic concept is expressed as lethargy coefficient. And S-N curve is obtained with the lethargy coefficient from quasi-static tensile test. Equivalent practical dynamic force is obtained from the identification of practical dynamic force for one loading point. Using the practical dynamic force and S-N curve, fatigue life of a window pillar is analyzed with FEM under the identified force by the procedure of above mentioned.

A Biomechanical Model of Lower Extremity Movement in Seated Foot Operation

  • Kyu-Sung Hwang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.60
    • /
    • pp.37-46
    • /
    • 2000
  • A biomechanical model of lower extremity in seated postures was developed to assess muscular activities of lower extremity involved in a variety of foot pedal operations. The model incorporated four rigid body segments with the twenty-four muscles to represent lower extremity This study deals with quasi-static movement to investigate dynamic movement effect in seated foot operation. It is found that optimization method which has been used for modeling the articulated body segments does not predict the forces generated from biarticular muscles and antagonistic muscles reasonably. So, the revised nonlinear optimization scheme was employed to consider the synergistic effects of biarticular muscles and the antagonistic muscle effects from the stabilization of the joint. For the model validation, three male subjects performed the experiments in which EMG activities of the nine lower extremity muscles were measured. Predicted muscle forces were compared with the corresponding EMG amplitudes and it showed no statistical difference. For the selection of optimal seated posture, a physiological meaningful criterion was developed for muscular load sharing developed. For exertion levels, the transition point of type F motor unit of each muscle is inferred by analyzing the electromyogram at the seated postures. Also, for predetermined seated foot operations exertion levels, the recruitment pattern is identified in the continuous exertion, by analyzing the electromyogram changes due to the accumulated muscle fatigue.

  • PDF

Design of Modular DC / DC Converter with Phase-Shifting Topology (위상천이 방식의 모듈형 DC/DC 컨버터 설계)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • This paper is concerned with a system design that enables a the plurality of switching mode power supplies to be supplied with larger power through a parallel connection. For this purpose, a shunt resistor is placed in series at the output of the constant voltage regulator and the output voltage is sensed and controlled using an arduino. In this paper, two constant-voltage regulators were used for the experiment, but it is possible to generalize for more boards. By using the method that controls the system, the sum of the currents delivered by the two systems to the load was found to be 96% of the current drawn from each board. In case of efficiency, 92.4% efficiency is achieved in the unit board and the efficiency in parallel connection is about 90%.

Numerical analysis and stability assessment of complex secondary toppling failures: A case study for the south pars special zone

  • Azarafza, Mohammad;Bonab, Masoud Hajialilue;Akgun, Haluk
    • Geomechanics and Engineering
    • /
    • v.27 no.5
    • /
    • pp.481-495
    • /
    • 2021
  • This article assesses and estimates the progressive failure mechanism of complex pit-rest secondary toppling of slopes that are located within the vicinity of the Gas Flare Site of Refinery No. 4 in South Pars Special Zone (SPSZ), southwest Iran. The finite element numerical procedure based on the Shear Strength Reduction (SSR) technique has been employed for the stability analysis. In this regard, several step modelling stages that were conducted to evaluate the slope stability status revealed that the main instability was situated on the left-hand side (western) slope in the Flare Site. The toppling was related to the rock column-overburden system in relation to the overburden pressure on the rock columns which led to the progressive instability of the slope. This load transfer from the overburden has most probably led to the separation of the rock column and to its rotation downstream of the slope in the form of a complex pit-rest secondary toppling. According to the numerical modelling, it was determined that the Strength Reduction Factor (SRF) decreased substantially from 5.68 to less than 0.320 upon progressive failure. The estimated shear and normal stresses in the block columns ranged from 1.74 MPa to 8.46 MPa, and from 1.47 MPa to 16.8 MPa, respectively. In addition, the normal and shear displacements in the block columns ranged from 0.00609 m to 0.173 m and from 0.0109 m to 0.793 m, respectively.