• Title/Summary/Keyword: Unit Cooler

Search Result 40, Processing Time 0.025 seconds

Thermal Characteristics of Hydrostatic Guideway in Ultra Precision Positioning (초정밀위치결정을 위한 유정압안내면의 온도특성 분석)

  • 박천홍;오윤진;황주호;이득우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.37-41
    • /
    • 2002
  • Thermal characteristics of hydrostatic guideway is largely depended on the temperature of supplied oil. For improving the positioning accuracy of hydrostatic guideway, relationship between setting temperature of oil cooler and thermal characteristics is analyzed, and influence of thermal characteristics on positioning accuracy is also analyzed experimental1y in this paper. Laser scale which has 0.01 $\mu\textrm{m}$ of resolution is used as feed-back unit. From the experimental results, it is confirmed that positioning error and repeatability is minimize upto 0.21 $\mu\textrm{m}$ and 0.18 $\mu\textrm{m}$ when the temperature of supplied oil is setting equal to temperature of atmosphere, and also confirmed that thermal deformation, which occurs by the temperature deviation between table and rail or scale supporter, works as limit of repeatability in long time operation.

  • PDF

Dynamic Modeling for the Coal Gasification Process (석탄가스화공정의 동적모델링)

  • 유희종;김원배;윤용승
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1997.10a
    • /
    • pp.47-53
    • /
    • 1997
  • Dynamic models have been developed for the coal gasification process by using a modular approach method. The complete unit is divided, for the convenience of the analysis, into several sections, viz. the coal feeding system, the gasifier, the gas cooler, the valves, the pumps, etc. The dynamic behaviour of each section is described in mathematical terms and each term is modulized into several submodels consisting of the complete process. To represent the behaviour of the fluid flow, the hydraulic network is proposed. Results for the more important system variables are presented and discussed. There dynamic models enable process and control engineers to quickly review a wide range of alternative operating and control strategies and help operators to easily understand the process dynamics and eventually can be applied to the design of commercial scale IGCC plants.

  • PDF

Experimental Study for Development of Air Eject Defrost Equipment (공기분사식 제상장치 개발에 관한 실험적 연구)

  • Han, In-Geun;Kim, Chang-Yeong;Kim, Jae-Dol;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.3
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.

Development of Cold Chain System Using Thermal Storage with Low-Energy Type (저 에너지형 축냉식 저온유통 시스템 개발)

  • Kwon K.H.;Jeong J.W.;Kim J.H.;Choi C.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.161-167
    • /
    • 2006
  • The purpose of this study is to find the optimal conditions of PCM slurry manufacturing equipment for saving the marketing cost and keeping the original quality of products. In addition, the characteristics of the movable container for shipping or distributing products is analysed. The major results are as follows. 1. PCM thermal storage system is designed with the conditions of temperature($-5{\sim}10^{\circ}C$), cold chain time(30 minutes), and one time usage(50 liter). This system includes tank, freezer, circulating pump, cycle type heat exchanger, swelling tank, equipment of supplying PCM supplying unit includes cold tank, cycle type heat exchanger, suction unit and control equipments, etc. 2. After ability test of PCM thermal storage system, it shows that the required freezing time of PCM thermal storage system is less than one of the previous system. The reason is that churn (top and bottom) and compulsion circulation are occurred simultaneously and unit cooler type method is better than chiller type method. 3. By the experiment of transportation latent heat container, it is decided that the best container is $K_1$ with latent heat temperature($0{\sim}5^{\circ}C$) and density(0.15%). However, for $K_l\;and\;K_2$, it is necessary more studies on latent heat thermal conditions and conditions of making method.

Function of Microclimate Amelioration by Urban Greenspace (도시녹지에 의한 미기후개선의 기능)

  • 조현길;안태원
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.4
    • /
    • pp.23-28
    • /
    • 1999
  • This study measured transpiration rate of urban trees and albedos of urban surfaces, and examined the function of microclimate amelioration by urban greenspace. Transpiration rates of trees were highest in July and August of growing months. Transpiration per unit leaf area for the two months was 300-350 g/$m^2$/h for Platanus occidentalis, 210-270 g/$m^2$/h for Ginkgo biloba and Zelkova serrata, and 130-140 g/$m^2$/h for Acer palmatum. Surface albedos were 0.09 for asphalt paving and 0.68 for white wall, which reveals that light-colored surfaces are better than dark-colored ones to lower the heat build-up. Due to lack of evapotranspiration, concrete surfaces were, at t midafternoon maximum, 8$^{\circ}C$ hotter than grass ones, though the albedo of concrete paving was higher thant that of grass and trees. Summer air temperatures at places with 12% and 22% cover of woody plants were, respectively, 0.6$^{\circ}C$ and 1.4$^{\circ}C$ cooler than a place with no vegetation. To mitigate the impacts of urban heat islands, required are minimization of hard surfaces, light-coloring for building surfaces, and greenspace enlargement including more plantings.

  • PDF

A Study on the Determination of Mixed Refrigerant for the Joule-Thomson Cryocooler (극저온 Joule-Thomson 냉동기용 혼합냉매 결정에 관한 연구)

  • 이경수;장기태;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.901-907
    • /
    • 2000
  • The conceptual determination of mixed-refrigerant (MR) for a closed Joule-Thomson cryocooler is described in this paper. The thermodynamic cycle design was mainly considered to develop a cryocooler by using a compressor of domestic air-conditioning unit. The target cooling performance of the designed cryocooler is 10 W around 70 K with less than 5 kJ/kg enthalpy rise. The systematic approach of choosing a proper refrigerant among 20 different kinds of mixture for such cryogenic temperature was introduced in detail. The main components of the cryocooler are compressor, evaporator, oil separator, after-cooler, counterflow heat exchanger, and J-T expansion device. Due to the limitation of the compressor operation range, the temperature after the compression was limited below $117^{\circ}C$ (390 K) and the temperature before compression was restricted above $5^{\circ}C$ (278 K). 20 atm of discharging pressure (high pressure) and less than 3 atm suction pressure (low pressure) were the design conditions. The inlet temperature of a counterflow heat exchanger in the high Pressure side was about 300 K. The proper composition of the mixed refrigerant for the designed J-T cryocooler is 15% mol of$ N_2, 30% mol of $CH_4,\; 30% mol\; of C^2H^ 6,\; 10%\; mol\; of\; C_3H_8\; and \;15%\; mol\; of\; i-C_4H_10$.

  • PDF

Design of Naphtha Splitter Unit with Petlyuk Distillation Column Using Aspen HYSYS Simulation (Aspen HYSYS를 이용한 나프타 분리공정의 Petlyuk Distillation Column 설계)

  • Lee, Ju-Yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.21-27
    • /
    • 2018
  • FRN (Full range Naphtha) is distilled from crude oil in a Naphtha Splitter Unit and is separated into the Light Straight Naphtha, Heavy Naphtha, and kerosene according to the boiling point in sequence. This separation is conducted using a series of binary-like columns. In this separation method, the energy consumed in the reboiler is used to separate the heaviest components and most of this energy is discarded as vapor condensation in the overhead cooler. In this study, the first two columns of the separation process are replaced with the Petlyuk column. A structural design was exercised by a stage to stage computation with an ideal tray efficiency in the equilibrium condition. Compared to the performance of a conventional system of 3-column model, the design outcome indicates that the procedure is simple and efficient because the composition of the liquid component in the column tray was designed to be similar to the equilibrium distillation curve. An analysis of the performance of the new process indicated an energy saving of 12.3% under same total number of trays and with a saving of the initial investment cost.

Thermal Performance of the Show-Case Cooler Using Ice Slurry Type Storage System (아이스슬러리형 축냉시스템을 이용한 쇼케이스 냉각장치의 열적성능에 관한 실험적 연구)

  • Lee, Dong-Won;Kim, Jeong-Bae
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.26-29
    • /
    • 2011
  • A promising alternative technology is the potential use of ice slurries as a secondary refrigerant in conventional cooling process. Ice slurries behave almost like a liquid and can be pumped through pipes although the energy capacity of ice slurries per unit volume is considerably higher than that for chilled water or brine due to the latent heat capacity of the ice particles. To give the basic data for the design of cooling systems using ice slurries, experimental study has been conducted to find out the performance of the cooling coil of show-case with ice slurries. Despite the fact that ice slurries entering the cooling coil had at least $5^{\circ}C$ higher temperature than that of R22, it was still capable of providing a similar cooling performance than that obtained with R22.

A Feasibility Study for the Application of the Cold-heat Storage System Considering the Real Operation Status of the Showcase (쇼케이스의 실제 운전상태를 고려한 축냉시스템 적용 가능성 평가 기초 연구)

  • Lee, Dong-Won;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.52-58
    • /
    • 2012
  • Experimental study was performed to understand the real operation conditions of a showcase working usually in a convenient store and discount store. The purpose of this study was to show the possibility for practical use of cold-heat storage systems being operated for the showcase. To do that, evaporator and condenser temperatures were measured and the compressor electric power consumption were measured simultaneously. To use the ice storage system, the ice making process was typically operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was subcooled using the stored cold-heat after being discharged from the condenser during daytime. So, the cooling performance was increased with the sub-cooling of refrigerant during daytime,hence the actual running time of the compressor could be effectively decreased. Through the experiments, this study showed that the compressor electric power consumption during daytime could be transferred to nighttime for applying the refrigerant sub-cooling. So, for the convenient store, the maximum load transfer rates for each working cooler and showcase were estimated about 31.1% and 19.9% respectively. And for the discount store, the maximum load transfer rates for each refrigeration and freezing showcase were estimated about 34.1% and 49.0% respectively.

Design of Naphtha Cracker Gas Splitter Process in Petlyuk Column (납사열분해 가스분리공정에서의 Petlyuk Column 설계)

  • Lee, Ju Yeong
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.1
    • /
    • pp.17-22
    • /
    • 2020
  • Light Naphtha is distillated from crude oil unit and separated into the methane, ethylene and propylene by boiling point difference in sequence. This separation is conducted using a series of binary-like columns. This separation method is known that the energy consumed in the reboiler is used to separate the heaviest components and most of this energy is discarded as vapor condensation in the overhead cooler. In this study, the first two columns of the separation process are replaced with the Petlyuk column. A structural design was exercised by the stage computation with ideal tray efficiency in equilibrium condition. Compared with the performance of a conventional system of 3-column model, The design outcome shows that the procedure is simple and efficient because the composition of the liquid component in the column tray was designed to be similar to the equilibrium distillation curve. The performance of the new process indicates that an energy saving of 12.1% is obtained and the cost savings of 44 million won per day based on gross domestic product is reduced under same total number of trays and the initial investment cost is saved.