• Title/Summary/Keyword: Uniformity control

Search Result 474, Processing Time 0.032 seconds

Seed Germination and Effect of Water Depths on Seedling Establishment of Iron-coated Rice Seeds (벼 철분코팅종자의 발아 특성 및 담수깊이에 따른 초기입모 영향)

  • Kim, Sang-Yeol;Park, Sung-Tae;Seo, Jong-Ho;Hwang, Chung-Dong;Bae, Hyun-Kyung;Oh, Myung-Kyu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.62 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • Germination characteristics, seedling emergence, and early seedling growth of iron-coated rice seeds, cultivars Daebo and Samdeokbyeo, under different water depths were compared with those of non-coated seeds (control) and the results evaluated to obtain basic information for establishing stable seedlings in direct water seeding. The total germination percentage of the two seed treatments was similar, but iron-coated seeds had slightly faster germination and shorter mean germination time than non-coated seeds. Water absorption rates of iron-coated seeds were lower than that of non-coated seeds during seed germination. The germination percentage of the two iron-coated rice seed cultivars showed a significant decline of 15-22% after one year of storage under natural conditions. The seedling emergence percentage and uniformity of the two rice cultivars were significantly higher in the iron-coated seeds at 1-13 cm water depths but the percentage of floating seedlings was lower in iron-coated seeds than in non-coated seeds. The iron-coated seeds had a high seedling emergence percentage of 91.3-93.3% at all flooding depths whereas the non-coated seeds had a significantly low seedling emergence percentage of 57.7-71.7% at a water depth of 13 cm. Moreover, the shoot dry weight and seedling health score of iron-coated seeds were significantly higher than those of non-coated seeds, while root dry weights were similar in iron-coated and non-coated seeds, regardless of water depth. These results suggest that iron-coated seeds are more appropriate for stable seedling establishment in direct water seeding than are non-coated seeds.

Foaming Properties and Flame Retardancy of the Foams Based on NBR/GTR Compounds (니트릴고무/타이어고무분말(GTR)를 이용한 발포체의 발포 및 난연 특성에 관한 연구)

  • Moon, Sung-Chul;Jo, Byung-Wook;Choi, Jae-Kon
    • Elastomers and Composites
    • /
    • v.37 no.3
    • /
    • pp.159-169
    • /
    • 2002
  • The improvement of flame retardancy of the foams based on NBR/GTR compounds was conducted by formulating various materials i.e. NBR, GTR, inorganic and phosphorus containing flame retardants, foaming agent, cross-linking agent and activator. The foaming properties, morphology, smoke density and flame retardancy of the specimens were investigated using SEM, LOI tester, smoke density control system and cone calorimeter. The phosphorus containing flame retardant reduces heat release rate, increases the limiting oxygen index and a char formation. The inorganic flame retardant increases the limiting oxygen index and reduces heat release rate with an increased CO yield by char formation, and smoke suppressing effect. The formed char seemed to intercept the oxygen transport and heat transfer into the core area. When the composition ratios of the compounds of NBR/GTR were $100{\sim}80/0{\sim}20 wt.%$, and the ratios of the rubbers/flame retardants were $1/1.55{\sim}3.60 wt.%$, we could developed foams with low heat release rate, high limiting oxygen index($28.0{\sim}39.3$), closed or semi-closed cell of uniformity and reasonable expandability($225{\sim}250 %$).

The effect of osmotic potentials on the temperature response for germination of pepper seed

  • Kim, Young Ae;Park, Sunyeob;Kim, Du Hyun
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.216-216
    • /
    • 2017
  • Primed seeds germinate faster and uniformly, since these have already started imbibition and metabolism requiring to complete germination. Several factors such as solution composition, osmotic potential, and treatment duration affect seed priming response. Water potentials of priming solution and germination response of primed seed were investigated to clarify the effects different inorganic salt types and the duration. Pepper seeds were primed in osmotic solutions that were osmotic potential ranged -1.54 to -0.45 MPa in an aerated solution of polyethylene glycol 8000 (PEG; 17%, 22%, 27%), and inorganic salt solution of $KNO_3$, $K_2SO_4$, and $Na_2SO_4$ (100, 200, 300mM) in aerated condition. The seeds were treated at $20^{\circ}C$ for 4, 6 day (D) and stepwise duration combined concentration of 100mM (2 or 4 days) and 300mM(2 or 4days). After soaking treatment, seeds were washed with distilled water and then were dried to approximately 6% moisture content in dry chamber at $25^{\circ}C$. The germination of seed was characterized by ISAT rules at $20^{\circ}C/30^{\circ}C$ and $15^{\circ}C$. Total germination percentage (GP), mean germination time (MGT), germination uniformity (GU), germination rate (GR), and health seedling percent (HS) were calculated on the germinated seed in a 14-day period. Seed water potential (${\psi}$) was correlated with water potential of priming solution ($r^2=0.84$). The effect of seed priming on germination varies with inorganic salt and organic agents (PEG). Germination percentage (GP, 77 and 73%), GR (21.3 and $19.4 %{\cdot}day^{-1}$), and HS (58 and 52 %) was greatest and lowest MGT (4.2 and 4.8 day) when they were primed in 100mM $K_2SO_4$ (${\psi}=-0.45MPa$), and 100mM $KNO_3$ (${\psi}=-0.52MPa$) for 6 days compared to untreated control (67% GP, $19.7%{\cdot}day^{-1}\;GR$, 18% HS, and 10.8 day MGT) in $15^{\circ}C$ chamber. Water potential less then -1.2MPa of osmotic solution resulted lower GP, GR and HS and in $K_2SO_4$ and $KNO_3$. However, stepwise treatment of water potential that changed solution as 100mM for 4 D + 300mM for 2 D or 300mM for 4 D + 100mM for 2 D) were not better than single concentration alone in germination characteristics.

  • PDF

Usefulness Assessment of Automatic Analysis Program for Flangeless Esser PET Phantom Images (Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가)

  • NamGung, Chang-Kyeong;Nam, Ki-Pyo;Kim, Kyeong-Sik;Kim, Jeong-Seon;Lim, Ki-Cheon;Shin, Sang-Ki;Cho, Shee-Man;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.63-66
    • /
    • 2009
  • Purpose: ACR (American College of Radiology) offers variable parameters to PET/CT quality control by using ACR Phantom. ACR Phantom was made to evaluate parameters which are uniformity, attenuation, scatter, contrast and resolution. Manual analysis method wasn't good for the use of QC because values of parameter were changed as it may user and it takes long time to analysis. Ki-Chun Lim, a nuclear scientist in AMC, developed program that automatically analysis values of parameter by using ACR Phantom to overcome above problems. In this study, we evaluated automatic analysis program's usability, through the comparing SUV of each method, reproducibility of SUV when repeated analysis and the time required. Materials and Methods: Using Flangeless Esser PET Phantom, the ideal ratio of 4 : 1 hot cylinder and BKG but it actually showed a ratio of 3.89 to 1 hot cylinder and BKG. SIEMENS Biograph True Point 40 was used in this study. We obtained images using ACR phantom at Fusion WB PET Scan condition (2 min/bed) and 120 kV, 100 mAs CT condition. Using True X method, 3 iterations, 14 subsets, Gaussian filter, FWHM 4 mm and Zoom Factor 1.0, $168{\times}168$ image size. We obtained Max. & Min. SUV and SUV Mean values at Cylinder (8, 12, 16, 25 mm, Air, Bone, Water, BKG) by automatic program and obtained SUV by manual method. After that, we compared manual and automatic method. we estimate the time required from opened the image data to final work sheet was completed. Results: Automatic program always showed same result and same the time required. At 8, 12, 16 and 25 m cylinder, manual method showed 6.69, 3.46, 2.59, 1.24 CV values. The larger cylinder size became, the smaller CV became. In manual method, bone, air, water's CV were over 9.9 except BKG (2.32). Obtained CV of Mean SUV showed BKG was low (0.85) and bone was high (7.52). The time required was 45 second, 882 second respectably. Conclusions: As a result of difference automatic method and manual method, automatic method showed always same result, manual method showed that the smaller hot cylinders became, the lager CV became. Hot cylinders mean region size, the smaller hot cylinder size becomes we had some trouble in doing ROI poison setting. And it means increase in variation of SUV. The Study showed the time required of automatic method was shorten then manual method.

  • PDF

Investigation on the Heating Patterns Depending on the Packaging Materials During Microwave Cooking (포장 소재에 따른 전자레인지 가열 조리 패턴 조사)

  • Lee, Hwa Shin;Cho, Ah Reum;Moon, Sang Kwon;Yoon, Chan Suk;Lee, Keun Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.21 no.1
    • /
    • pp.27-34
    • /
    • 2015
  • Heating patterns depending on the packaging materials were examined in order to investigate the causes of thermal deformation of packages used for ready-to-eat foods for microwave heating due to the non-uniformity of microwaves. Physical properties including tensile strength, heat-resistance and elongation of four different CPP grades were compared. High retortable CPP had higher sealing strength and heat resistance compared to the conventional CPPs. All CPP samples tested were proved to have melting temperatures around $160^{\circ}C$. However, they were all thermally deformed by microwave heating due to a limited penetration of microwave and non-uniform heating within the spicy sauce of high viscosity contained high salt, especially on the above the filling line and sealing edge of pouches. When the laminated stand-up pouches composed of G-PET/PET/PET/CPP and G-PET/PET/NY/CPP were retorted and microwaved, significant deformations were noticed in both samples after retorting. Besides, pouches contained titanium dioxide showed more intense thermal deformation than the control. When the $10{\mu}m$ aluminium foil was affixed on the pouch, small thermal deformation was observed only in the bottom layer. More studies are required to prevent the thermal deformation of packaging materials used for RTE foods during microwave heating by developing the technologies to increase the thermal stability of CPP layer and the modification of packaging design to modify the microwave access into the package.

  • PDF

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.23-26
    • /
    • 2005
  • Introduction: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Methods and Materials: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator , an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was performed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS (192-Ir HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3000cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Result: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1cGy, 57.1cGy, 103.8cGy, 162.7cGy, 165.7cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1cGy, 57.1cGy Conclusion: Patients with locally recurrent tumor in uterine cervix cancer treated with modified MIUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry Provided by the template and cylinders, and improved dose distributions in irregular tumor volume without rectal complication

  • PDF

Evaluation of Deformation Characteristics and Vulnerable Parts according to Loading on Compound Behavior Connector (복합거동연결체의 하중재하에 따른 변형 특성 및 취약부위 산정)

  • Kim, Ki-Sung;Kim, Dong-wook;Ahn, Jun-hyuk
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.524-530
    • /
    • 2019
  • Purpose: In this paper, we construct a detailed three-dimensional interface element using a three-dimensional analysis program, and evaluate the composite behavior stability of the connector by applying physical properties such as the characteristics of general members and those of reinforced members Method: The analytical model uses solid elements, including non-linear material behavior, to complete the modeling of beam structures, circular flanges, bolting systems, etc. to the same dimensions as the design drawing, with each member assembled into one composite behavior linkage. In order to more effectively control the uniformity and mesh generation of other element type contact surfaces, the partitioning was performed. Modeled with 50 carbon steel materials. Results: It shows the displacement, deformation, and stress state of each load stage by the contact adjoining part, load loading part, fixed end part, and vulnerable anticipated part by member, and after displacement, deformation, The effect of the stress distribution was verified and the validity of the design was verified. Conclusion: Therefore, if the design support of the micro pile is determined based on this result, it is possible to identify the Vulnerable Parts of the composite behavior connector and the degree of reinforcement.

Superconducting Thick Film by Lateral Field Assisted EPD (측면보조전계 인가 전기영동전착 초전도후막)

  • 전용우;소대화;조용준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.679-685
    • /
    • 2004
  • Although the electrophoretic deposition method has the advantage of simple processing procedure, less fabrication facilities, and easier control for deposition thickness and wire length, providing economical and technical merits, it also has the disadvantages of cracking and porosity phenomena, requiring an improved processing method for higher particle density and constant particle orientation. we have developed an optimization method to increase the particle density and to unify its orientation, and have performed a study to overcome the cracking and porosity problems in the fabricated superconductor. In order to improve the surface uniformity and the conduction properties of the fabricated YBCO thick films, a system that applies alternate voltage vertically has been developed for the first time and applied to the electrophoretic deposition process. The applied alternate electric field caused a force to be exerted on each YBCO particle and resulted in a rotation of the particle in the direction of applied electric field, accomplishing a uniform particle orientation. We name this process as the shaky-aligned electrophoretic deposition method. For commercial utilization and efficiency, in this dissertation, alternating voltage of 60 Hz and 25 ∼ 120 V/cm was proposed to apply it as a subsidiary source for shaky-flow deposition so that the fabricated thin film showed uniform surface morphology with less voids and cracks and Tc,zero of 90 K and the critical current density of 3419 A/$cm^2$.

A Proposal of USN-based DER(Decentralized Energy Resources) Management System (USN 기반의 댁내 분산 전력 관리 시스템 제안)

  • Kim, Bo-Min;Kim, Jeong-Young;Bang, Hyun-Jin;Jang, Min-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.871-874
    • /
    • 2010
  • Needs for Smart Grid development are increasing all over the world as a solution to its problem according to depletion of energy resources, climatic and environmental rapidly change and growing demand for electrical power. Especially decentralized power is attracting world's attention. In this mood a new era for a unit scale of decentralized power environment is on its way in building. However there is a problem to have to be solved in the uniformity of power quality because the amount of power generated from renewable energy resources such as wind power and solar light is very sensitive to climate fluctuation. And thus this paper tries to suggest an energy management method on basis of real time monitoring for meteorological data. In the current situation of lacking in USN-based killer application in Smart Grid field, this paper proposes the USN-based DER management system which collects the meteorological data and control power system througout utilizing wireless sensor network technique this business. This communication technique is regarded to be efficient in aspects of installation cost and tits maintenance cost. The proposed EMS model embodies the method for predicting the power generation by monitoring and analyzing the climatic data and controling the efficient power distribution between the renewable energy and the existing power. The ultimate goal of this paper is to provide the technological basis for achieving zero-energy house.

  • PDF

Terms Standardization between the Rules of Diagnosis Radiation Equipment Safety Management and Atomic Energy Law : Problems and Suggestions (진단용 방사선발생장치의 안전관리에 관한 규칙과 원자력법의 용어통일 개선 방향)

  • Kim, Hwa-Gon;Kang, Se-Sik;Kim, Chang-Soo;Park, Cheol-Seo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.39-46
    • /
    • 2006
  • The rules and terms are described different meaning, in this results the research is accomplished for preventing practical workers from confusion. Atomic law are kept up modification and development in our situation by the ICRP's recommendation, on the other hand, the rules of diagnosis radiation equipment safety managements are modified partial, then resulted in confusion. The study was comparison between the rules of diagnosis radiation equipment safety management and atomic energy law, and the modification items obtained were as follows. 1. With each other different the terms and units are used. With the exception of special terms for affairs usage, it is needless to say that common term uniformity is standardized. The standardization of rules and guidance have not need to confusion radiological practical workers. 2. The following is omitted. 1) The radiation protection against tile patient and the hospital visitor. 2) Radiation dose limit of the woman patient who is in the process of becoming pregnant. 3) Radiation dose limit of the person who is not regarded as madical madical exposure. 4) The control of the exposure of pregnant of women at work.

  • PDF