• Title/Summary/Keyword: Uniformity Coefficient

Search Result 160, Processing Time 0.033 seconds

Preparation of MgO Protective layer by reactive magnetron Sputtering (반응성 스퍼트링에 의한 MgO 유전체 보호층 형성에 관한 연구)

  • Ha, H. J.;Lee, W. G.;Ryu, J. H.;Song, Y.;Cho, J. S.;Park, C. H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.59-62
    • /
    • 1996
  • Plasma displays (PDP) as a large area wall-hanging display device are rabidly developed with flat CRT, TPT LCD and etc. Especially, AC Plasma Display Panels(AC PDPs) have the inherent memory function which is effective for large area displays. The memory function in AC PDPs is caused by the accumulation of the electrical charge on the protecting layer formed on the dielectric layer. This MgO protective layer prevents the dielectric layer from sputtering by ion in discharge plasma and also has the additional important roll in lowering the firing voltage due to the large secondary electron emission coefficient). Until now, the MgO Protective layer is mainly formed by E-Beam evaporation. With increasing the panel size, this process is difficult to attain cost reduction, and are not suitable for large quantity of production. To the contrary, the methode of shuttering are easy to apply on mass production and to enlarge the size of the panel and shows the superior adhesion and uniformity of thin film. In this study, we have prepared MgO protective layer on AC PDP Cell by reactive magnetron sputtering and studied the effect of MgO layer on the surface discharge characteristics of ac PDP.

  • PDF

Analysis of Spray Characteristics of Tractor-mounted Boom Sprayer for Precise Spraying

  • Kim, Ki-Duck;Lee, Hyeon-Seung;Hwang, Seok-Joon;Lee, Young-Joo;Nam, Ju-Seok;Shin, Beom-Soo
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.258-264
    • /
    • 2017
  • Purpose: This study determines the spray characteristics and effective spray width of a tractor-mounted commercial boom sprayer through experiments. Methods: Performance tests were conducted to investigate the spray characteristics of the nozzles on a commercial boom sprayer. The flow rate and spray width of a single nozzle were measured at three levels of spray pressure (0.5, 0.7, and 1.0 MPa) and spray height (15, 30, and 45 cm), respectively. The average value of three repetition tests was used as the representative value. A coefficient of variation (CV) was used as an index of spray uniformity, and the width that guarantees CV values of approximately 15% was determined as the effective spray width. The spray characteristics of the overall boom sprayer were derived analytically by superimposing the spray characteristics of a single nozzle. Results: The test results for a single nozzle showed that the spray width tended to increase as the spray height and spray pressure increased. The effective spray width for a single nozzle was the largest at a spray pressure of 1.0 MPa and spray height of 45 cm, which resulted in a coverage of 84 cm of width. The effective spray width for the entire boom sprayer was also the largest at the spray pressure of 1.0 MPa and spray height of 45 cm, with a magnitude of 424.5 cm. The chemical spraying work in an actual field was simulated by applying a spray width of 400 cm. As a result of the operation for three swaths, the CV value was less than 10% for 1,200 cm of the overall spray width, which meant that uniform application was achieved. Conclusions: It was reasonable to set the effective spray width of the boom sprayer used in this study to 400 cm.

Analysis on Bowing and Formation of Al Doped P+ Layer by Changes of Thickness of N-type Wafer and Amount of Al Paste (N타입 결정질 실리콘 웨이퍼 두께 및 알루미늄 페이스트 도포량 변화에 따른 Bowing 및 Al doped p+ layer 형성 분석)

  • Park, Tae Jun;Byun, Jong Min;Kim, Young Do
    • Korean Journal of Materials Research
    • /
    • v.25 no.1
    • /
    • pp.16-20
    • /
    • 2015
  • In this study, in order to improve the efficiency of n-type monocrystalline solar cells with an Alu-cell structure, we investigate the effect of the amount of Al paste in thin n-type monocrystalline wafers with thicknesses of $120{\mu}m$, $130{\mu}m$, $140{\mu}m$. Formation of the Al doped $p^+$ layer and wafer bowing occurred from the formation process of the Al back electrode was analyzed. Changing the amount of Al paste increased the thickness of the Al doped $p^+$ layer, and sheet resistivity decreased; however, wafer bowing increased due to the thermal expansion coefficient between the Al paste and the c-Si wafer. With the application of $5.34mg/cm^2$ of Al paste, wafer bowing in a thickness of $140{\mu}m$ reached a maximum of 2.9 mm and wafer bowing in a thickness of $120{\mu}m$ reached a maximum of 4 mm. The study's results suggest that when considering uniformity and thickness of an Al doped $p^+$ layer, sheet resistivity, and wafer bowing, the appropriate amount of Al paste for formation of the Al back electrode is $4.72mg/cm^2$ in a wafer with a thickness of $120{\mu}m$.

Reflection on Kinetic Models to the Chlorine Disinfection for Drinking Water Production

  • Lee, Yoon-Jin;Nam, Sang-ho
    • Journal of Microbiology
    • /
    • v.40 no.2
    • /
    • pp.119-124
    • /
    • 2002
  • Experiments for the characterization of inactivation were performed in a series of batch processes with the total coliform used as a general indicator organism based on the chlorine residuals as a disinfectant. The water samples were taken from the outlet of a settling basin in a conventional surface water treat- ment system that is provided with the raw water drawn from the mid-stream of the Han River, The inactivation of total coliform was experimentally analysed for the dose of disinfectants contact time, filtration and mixing intensity. The curves obtained from a series of batch processes were shaped with a general tailing-off and biphasic mode of inactivation, i.e. a sharp loss of bacterial viability within 15 min followed by an extended phase. In order to observe the effect of carry-over suspended solids on chlorine consumption and disinfection efficiency, the water samples were filtered, prior to inoculation with coliforms, with membranes of both 2.5$\mu$m and 11.0 $\mu$m pore size, and with a sand tilter of 1.0 mm in effective size and of 1.4 in uniformity coefficient. As far as the disinfection efficiency is concerned, there were no significant differences. The parameters estimated by the models of Chick-Wat-son, Hom and Selleck from our experimental data obtained within 120 min are: log(N/N$\_$0/)=-0.16CT with n=1, leg(N/N$\_$0/)=-0.71C$\^$0.87/ with n 1 for the Chick-Watson model, log (N/N$\_$0/)=-1.87C$\^$0.47/ T$\^$0.36/ for the Hom model, log (MHo)=-2.13log (1+CT/0.11) for the Selleck model. It is notable that among the models reviewed with regard to the experimental data obtained, the Selleck model appeared to most closely resemble the total coliform survival curve.

Fragmentation Fractal Analysis on Particle-size Distribution (Fragmentation 프랙탈을 이용한 입도분포 분석)

  • 민덕기;이완진
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.199-206
    • /
    • 2003
  • Particle-size distribution in soils is one of the most fundamental physical properties of soils. One of the latest developments in the study of particle-size distributions has focused on the use of fractal theories. In this study, the fragmentation fractals were used for determining the characteristics of the particle-size distribution curve. It was shown that the mass-size distribution method was more practical than the cumulative number-size distribution method. From the co-relation between fractal dimensions($D_{tot}$) and the coefficient of uniformity($C_{u}$), there was a sharp increase in fractal dimensions for $C_{u}$<4, but fractal dimension converged the single value for $D_{u}$$\geq$6. Fractal dimensions were affected by small sized particles for $C_{c}$$\geq$3 and large sized particles for $C_{c}$/<3. As a result of the analysis of the influence of the effective size($D_{10}$), it was observed that the changes of $D_{tot}$/ were nominal beyond the effective size.

A Study on Utility for Fine Aggregates and Engineering Characteristics by Mineralogical Composition of Sands on the Coast of Jeju Island (제주 해안지역 모래의 광물성분에 기인한 공학적 특성 및 잔골재 활용방안 연구)

  • Kim, Seung Hyun;Lee, Dong Wook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.4
    • /
    • pp.57-68
    • /
    • 2014
  • This study categorizes the distributed sand around coastal area of Jeju volcanic Island into three groups according to their components, and arranges their characteristics. In the case of basic physical properties, the silicate sand has slightly greater specific gravity than general sand, and the carbonate sand with widespread distribution has a lower specific gravity. In the gross, the carbonate sand has poor particle classifying and low uniformity coefficient because carbonate minerals of relatively large grain size are mixed. The relation between compressive strength and components shows conflicting tendency that silicate and carbonate components have positive correlation and negative correlation with compressive strength, respectively. Based on the components ratio of one to one, the sand having low carbonate component ratio is expected to be able to utilize in construction fine aggregate. To compare between square root (ACI 308) and cube root (KCI 2012) of compressive strength at computation of elastic modulus, it is considered to non-dimensional elastic modulus.

Influence of latitude wind pressure distribution on the responses of hyperbolodial cooling tower shell

  • Zhang, Jun-Feng;Ge, Yao-Jun;Zhao, Lin
    • Wind and Structures
    • /
    • v.16 no.6
    • /
    • pp.579-601
    • /
    • 2013
  • Interference effects are of considerable concern for group hyperboloidal cooling towers, but evaluation methods and results are different from each other because of the insufficient understanding on the structure behavior. Therefore, the mechanical performance of hyperboloidal cooling tower shell under wind loads was illustrated according to some basic properties drawn from horizontal rings and cantilever beams. The hyperboloidal cooling tower shell can be regarded as the coupling of horizontal rings and meridian cantilever beams, and this perception is beneficial for understanding the mechanical performance under wind loads. Afterwards, the mean external latitude wind pressure distribution, CP(${\theta}$), was artificially adjusted to pursue the relationship between different CP(${\theta}$) and wind-induced responses. It was found that the maximum responses in hyperboloidal cooling tower shell are primarily dominated by the non-uniformity of CP(${\theta}$) but not the local pressure amplitude CP or overall resistance/drag coefficient CD. In all the internal forces, the maximum amplitude of meridian axial tension shows remarkable sensitivity to the variation of CP(${\theta}$) and it's also the controlling force in structure design, so it was selected as an indicator to evaluate the influence of CP(${\theta}$) on responses. Based on its sensitivity to different adjustment parameters of CP(${\theta}$), an comprehensive response influence factor, RIF, was deduced to assess the meridian axial tension for arbitrary CP(${\theta}$).

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Characteristics of wind loading on internal surface and its effect on wind-induced responses of a super-large natural-draught cooling tower

  • Zou, Yun-feng;Fu, Zheng-yi;He, Xu-hui;Jing, Hai-quan;Li, Ling-yao;Niu, Hua-wei;Chen, Zheng-qing
    • Wind and Structures
    • /
    • v.29 no.4
    • /
    • pp.235-246
    • /
    • 2019
  • Wind loading is one of important loadings that should be considered in the design of large hyperbolic natural-draught cooling towers. Both external and internal surfaces of cooling tower are under the action of wind loading for cooling circulating water. In the previous studies, the wind loads on the external surface attracted concernedly attention, while the study on the internal surface was relatively ware. In the present study, the wind pressure on the internal surface of a 220 m high cooling tower is measured through wind tunnel testing, and the effect of ventilation rate of the packing layer on internal pressure is a major concern. The characteristics of internal wind pressure distribution and its effect on wind-induced responses calculated by finite element method are investigated. The results indicate that the wind loading on internal surface of the cooling tower behaves remarkable three-dimensional effect, and the pressure coefficient varies along both of height and circumferential directions. The non-uniformity is particularly strong during the construction stage. Analysis results of the effect of internal pressure on wind-induced responses show that the size and distribution characteristics of internal pressure will have some influence on wind-induced response, however, the outer pressure plays a dominant role in the wind-induced response of cooling tower, and the contribution of internal pressure to the response is small.

Experimental Study of Pressure Drop in Compressible Fluid through Porous Media (다공성재를 통과하는 압축성 유체의 압력강하에 관한 실험적 연구)

  • Seo, Min Kyo;Kim, Do Hun;Seo, Chan Woo;Lee, Seoung Youn;Jang, Seok Pil;Koo, Jaye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.759-765
    • /
    • 2013
  • This study proposes the characteristics of the pressure drop in a compressible fluid through porous media for application to a porous injector in a liquid rocket engine in order to improve the uniformity of the drop size distribution and the mixing performance of shear coaxial injectors. The fluid through the porous media is a Non-Darcy flow that shows a Nonlinear relation between the pressure drop and the velocity at high speed and high mass flow rate. The pressure drop of the Non-Darcy flow can be derived using the Forchheimer equation that includes the losses of viscous and inertia resistance. The permeability and Ergun coefficient represented as a function of the pressure drop and pore size can be applied to the porous injector, where the fluid through the porous media is compressible. A generalized correlation between the pressure drop in relation to the pore size was derived.