• 제목/요약/키워드: Uniform Flow

검색결과 1,419건 처리시간 0.023초

에어포일 이산소음 특성에 관한 연구 (A Study on Discrete Frequency Noise from a Symmetrical Airfoil in a Uniform Flow)

  • Kim, H. J.;Lee, S.;N. Fujisawa
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.365.2-365
    • /
    • 2002
  • The flow field around a symmetrical airfoil in a uniform flow under the generation of noise was studied by experiments and numerical simulation. The experiments are conducted by visualizing the surface flow over the airfoil with a shear-sensitive liquid-crystal coating and by measuring the instantaneous velocity field around the trailing edge of the airfoil. The numerical simulation was carried out by LES. (omitted)

  • PDF

SOFC 셀 성능 향상 및 수명 저하 방지를 위한 입구와 출구 2개의 유로 설계 (Design of flow path with 2 inlet and outlets to improve cell performance and prevent cell degradation in Solid Oxide Fuel Cell)

  • 김동우;염은섭
    • 한국가시화정보학회지
    • /
    • 제19권2호
    • /
    • pp.56-62
    • /
    • 2021
  • Solid oxide fuel cells (SOFCs) is the high efficiency fuel cell operating at high temperatures ranging from 700-1000℃. Design of the flow paths of the fuel and air in SOFCs is important to improve cell performance and prevent cell degradation. However, the uneven distribution of current density in the traditional type having one inlet and outlet causes cell degradation. In this regard, the parallel flow path with two inlet and outlets was designed and compared to the traditional type based on computational fluid dynamics (CFD) simulation. To check the cell performance, hydrogen distribution, velocity distribution and current density distribution were monitored. The results validated that the parallel designs with two inlets and outlets have a higher cell performance compared to the traditional design with one inlet and outlet due to a larger reaction area. In case of uniform-type paths, more uniform current density distribution was observed with less cross-sectional variation in flow paths. In case of contracted and expanded inflow paths, significant improvement of performance and uniform current density was not observed compared to uniform parallel path. Considering SOFC cell with uniform current density can prevent cell degradation, more suitable design of SOFC cell with less cross-sectional variation in the flow path should be developed. This work can be helpful to understand the role of flow distribution in the SOFC performance.

링 블로어 내부유동장 및 성능특성 연구 (Performance and Internal Flow Analysis on Ring Blower)

  • 장춘만;한기영
    • 한국유체기계학회 논문집
    • /
    • 제11권4호
    • /
    • pp.38-44
    • /
    • 2008
  • This paper describes the performance and internal flow characteristics of two-stage high pressure ring blower. Chamber-type test rig is designed and manufactured for the performance test of the ring blower. Detailed flow characteristics inside the impeller and casing are analyzed by three-dimensional numerical simulation. Throughout numerical simulation, non-uniform inflow to the impeller inlet and reverse flow are observed near the inlet duct of the blower. This non-uniform inflow makes various recirculation flow inside the casing with the complicated shape of casing. Low velocity region is locally formed near the both sides of impeller outlet due to the non-uniform inflow to the impeller, thus deteriorates the performance of a ring blower.

액체중의 원형 실린더 주위에서의 강제대류 층류 열전달에 관한 수치해석적 연구 (A Numerical Study on the Laminar convective Heat Transfer around a Circular Cylinder in a Uniform Cross Flow of Liquid)

  • 강신형;홍기혁
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.26-36
    • /
    • 1996
  • Many researches were carried out to estimate heat transfer rate on a circular cylinder in a uniform flow. Various empirical correlations were suggested in the past through experimental studies, however there are considerable discrepancies in the estimated values of heat transfer coefficient. The effect of fluid physical properties on the forced convective heat transfer between a circular cylinder and the external flow was numerically investigated in the present study, The flow and temperature fields were solved using a Finite Volume Method over a wider range of Prandtl number(0.7-40,000) than existing correlations. The cold as well as the hot cylinders in the uniform liquid flow of constant temperature were investigated. A unified correlation was obtainde for both cases.

  • PDF

하이브리드법을 이용한 열전냉각의 수치해석 연구 (Computer Simulation Study of the Thermoelectric Cooling by Hybrid Method)

  • 김남진;이재용;김종보
    • 태양에너지
    • /
    • 제20권1호
    • /
    • pp.97-108
    • /
    • 2000
  • The purpose of this study is to minimize the heat transfer surface area and cold fluid exit temperature of heat exchanger which applied to the refrigeration and air-conditioning system by utilizing the thermoelectric principle. Both uniform and non-uniform current distribution methods which applied to the analysis of the TE elements that incorporates heat exchanger were investigated. The non-uniform current distribution method had the better coefficient of performance and had the lower cold fluid exit temperature of the TE cooling system than the uniform current distribution method. It was found that if a TE cooling system incorporates a heat exchanger, a non-uniform current distribution should guarantee to the lowest cold fluid exit temperature. Also, the hybrid method (combination of the uniform and non-uniform current distribution method) is investigated to achieve the best results by combining the uniform and non-uniform current distributions. The results show that it can lower the cold fluid exit temperature and reduce the heat transfer surface area for the parallel flow arrangement if we apply the constant current in some entry region and the non-uniform increasing current in the direction of the cold fluid flow afterwards.

  • PDF

Uncertainty assessment for a towed underwater stereo PIV system by uniform flow measurement

  • Han, Bum Woo;Seo, Jeonghwa;Lee, Seung Jae;Seol, Dong Myung;Rhee, Shin Hyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권5호
    • /
    • pp.596-608
    • /
    • 2018
  • The present study aims to assess test uncertainty assessment method of nominal wake field measurement by a Stereoscopic Particle Image Velocimetry (SPIV) system in a towing tank. The systematic uncertainty of the SPIV system was estimated from repeated uniform flow measurements. In the uniform flow measurement case, time interval between image frames and uniform flow speed were varied to examine the effects of particle displacement and flow around the SPIV system on the systematic standard uncertainty. The random standard uncertainty was assessed by repeating nominal wake field measurements and the estimated random standard uncertainty was compared with that of laser Doppler velocimetry. The test uncertainty assessment method was applied to nominal wake measurement tests of a very large crude oil carrier model ship. The nominal wake measurement results were compared with existing experimental database by other measurement methods, with its assessed uncertainty.

과열기 관군에서의 증기유량 균일 배분 연구 (A Study on the Uniform Distribution of Steam Flow in the Superheater Tube System)

  • 박호영;김성철
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.416-426
    • /
    • 2008
  • The boiler tube failure often experienced in the superheater of a utility boiler can seriously affect the economic and safe operation of the power plant. It has been known that this failure is mainly caused by the thermal load deviation in the superheater tube system, and deeply intensified by the non-uniform distribution of steam flow rates. The nonuniform steam flow is distinctively prominent at low power load rather than at full power load. In this paper, we analyze the steam flow distribution in the superheater tube system by using one dimensional flow network model. At 30% power load, the deviation of steam flow rate is predicted to be within 0.8% of the averaged flow rate. This deviation can be reduced to 0.1% and 0.07% by assuming two cases, that is, the removal of 13th tube at each tube rows and the installation of intermediate header, respectively. The assumed two cases would be effective for the uniform steam flow distribution across 85 superheater tube rows.

초음속 흡입구의 통로길이와 받음각에 따른 유동장 변화 연구 (A NUMERICAL STUDY OF FLOWFIELD AT A SUPERSONIC INLET BY CHANGING ANGLES OF ATTACK AND CHANNEL LENGTH)

  • 류경진;임설;김상덕;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.21-27
    • /
    • 2010
  • The flow characteristics on a supersonic inlet with bleeding system by changing angles of attack and channel length conditions are studied by computational 3D turbulent flow analysis. A compressible upwind flux difference splitting Navier-Stokes method with $k-{\omega}$ turbulence model is used to analysis the inlet flowfield. More non-uniform flowfields are shown at the AIP when angle of attack becomes bigger and bigger. These non-uniform flowfield works the performance aggravating factors of the supersonic engine. Non-uniform flowfield by changing channel length at the various angle of attack are investigated.

  • PDF

고밀도 균일 안개스크린을 위한 에어로졸 유동의 최적 생성조건 (Optimal Conditions of Aerosol Flow Generation for High-density and Uniform Fog Screen)

  • 신동수;송우석;김진원;김우진;구자예
    • 한국분무공학회지
    • /
    • 제22권1호
    • /
    • pp.13-21
    • /
    • 2017
  • The fog screen is a device projecting the media to the aerosol flow field. As major parameters to generate dense and steady fog screen, shear stress, optical blockage ratio and SMD were obtained result through experiment. The micro droplet was generated by the piezo oscillation element, and the aerosol flow mixed with an air flow was sprayed into the vertical direction from the top of the fog screen through the 280 mm slot. For produce a dense, uniform fog screen, the shear effect, optical blockage ratio and SMD between aerosol and air curtain were measured. The minimum and maximum shear stress conditions were selected and it was confirmed that the optical transmission deviation of the aerosol flow field was small when the aerosol and air curtain flow rates were changed. When the aerosol and air curtain flow power were 18 V (1.51 m/s) and 24 V (2.55 m/s), respectively, under the condition of the minimum shear stress and laminar flow, the optical blockage ratios with the spray length were small, and it produced a most stable and high density uniform fog screen by injecting a constant of $10{\mu}m$ or less.

물성치의 변화를 고려한 균일유동 중에 있는 원형 실린더 주위의 층류 열전달 (Effects of Variable Properties on the Laminar Heat Transfer around a Circular Cylinder in a Uniform Flow)

  • 강신형;홍기혁;고상근
    • 대한기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.1584-1595
    • /
    • 1993
  • 본 연구에서는 Re수가 40이하의 정상 층류유동에서 온도가 실린더와 자유유동 사이의 열전달계수에 미치는 영향을 수치해석적으로 연구하였다. 유체의 온도 Ta를 200~900K, 실린더의 온도Tw를 300~900K의 범위에서 Tm/Ta를 0.67~2.75까지 변화시 키며 계산을 수행하였다. 수치계산 결과를 분석하여 실험적으로 관찰하기 어려운 불성치의 변화가 열전달에 미치는 영향을 검토하고, 아울러 실린더가 자유유동에 의해서 냉각되는 경우 뿐만 아니라 가열되는 경우의 연구도 병행하였고, 두가지 경우 에 모두 적용할 수 있는 열전달관계식을 구하였다. 본 연구에서는 Gr/$Re^2$=0 이고 복사에 의한 열전달량은 강제대류에 의한 열전달량의 1%이하이므로 자연대류 및 복사열 전달의 효과는 무시하였다.