• 제목/요약/키워드: Unified PWM

검색결과 16건 처리시간 0.022초

A New Method for Elimination of Zero-Sequence Voltage in Dual Three-Level Inverter Fed Open-End Winding Induction Motors

  • Geng, Yi-Wen;Wei, Chen-Xi;Chen, Rui-Cheng;Wang, Liang;Xu, Jia-Bin;Hao, Shuang-Cheng
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.67-75
    • /
    • 2017
  • Due to the excessive zero-sequence voltage in dual three-level inverter fed open-end winding induction motor systems, zero-sequence circumfluence which is harmful to switching devices and insulation is then formed when operating in a single DC voltage source supplying mode. Traditionally, it is the mean value instead of instantaneous value of the zero-sequence voltage that is eliminated, through adjusting the durations of the operating vectors. A new strategy is proposed for zero-sequence voltage elimination, which utilizes unified voltage modulation and a decoupled SVPWM strategy to achieve two same-sized equivalent vectors for an angle of $120^{\circ}$, generated by two inverters independently. Both simulation and experimental results have verified its efficiency in the instantaneous value elimination of zero-sequence voltage.

직류 지하철 급전시스템용 회생인버터 시스템 (Regeneration inverter system for DC traction system)

  • 조기현;장수진;김종윤;원충연;김용기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.28-32
    • /
    • 2007
  • In this paper, a unified regenerative inverter and control algorithm are proposed in order to perform regenerative action and active power filter action. While the regenerative mode of traction, it works as regenerative inverter to reduce a excessive power of DC bus line and the powering mode of the traction, it works as active power filter to compensate ac current distortion, power factor, and voltage unbalance. In the paper, a regeneration inverter used PWM DC/AC inverter algorithm. And an active power filter used p-q theory. We are carrying out a mode analysis of DC traction system similar to actual system with MG-set and experimenting with prototype model. Through the simulation and experiment, we were proving the regeneration inverter operation which suggested in this paper.

  • PDF

UPFC의 스위칭레벨 상세 모의 및 동적 특성 고찰 (Study of Dynamic Characteristics of an UPFC Switching-Level Model)

  • 원동준;김선호;한학근;이송근;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1287-1289
    • /
    • 1999
  • The UPFC(Unified Power Flow Controller) controls the magnitude and phase of the series injected voltage to exchange the real and reactive power with transmission line. The UPFC consists of two inverters connected together through the DC link capacitor. This paper describes the detailed UPFC switching-level model. PWM (Pulse Width Modulation) method is chosen to operate the inverters. Automatic voltage control mode and automatic power flow control mode is selected to control the UPFC. EMTP simulation is offered to obtain the basic operation characteristics of the UPFC and the dynamic characteristics of the UPFC is studied in detail.

  • PDF

직류가선전압 모의장치를 적용한 지하철용 회생인버터 시스템 (Regenerative Inverter System for Railway with DC Line Voltage Simulator)

  • 지용혁;조기현;장수진;원충연;김용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1515-1521
    • /
    • 2007
  • In this paper, a unified regenerative inverter system for railway with DC line voltage simulator is proposed. In order to determine the operation characteristics of the regenerative inverter, the DC line voltage simulator is proposed. The DC line voltage simulator, which is based on the AC-DC PWM converter, varies the DC voltage according to the fluctuating voltage which is measured in the actual DC line. The suitable operating point of the regenerative inverter can be estimated from the simulation result. The regenerative inverter operates two modes. When the DC line voltage exceed the operating point, already set up, it works as regenerative inverter to return the excessive power of DC line to the grid. When the DC line voltage is under the operating point, it works as active power filter to compensate harmonic currents. In this paper, the control algorithm of the DC line voltage simulator and that of the regenerative inverter is proposed.

  • PDF

Minimum Current Control for PWM Inverter-Mounted Drive System

  • Shin, Woo-Seok;Choe, Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.352-356
    • /
    • 1998
  • This paper describes minimum current control method for size reduction and performances improvement at unified inverter-induction motor system. This control method is based on V/F without speed sensor. Through the use of minimum stator current points at required torque during V/F operation it is possible to minimize the size of heat-sink related with the losses of power circuit and to improve overall efficiency compared to conventional V/F control. Using this proposed scheme, it is so much more useful to apply to some fields such a selectric vehicles. air conditioning system and textile mills where the limited space is given and required low cost.

  • PDF

영구 자석형 동기 전동기를 이용한 고속 엘리베이터 구동 시스템 개발 (Development of High-Speed Elevator Drive System using Permanent-magnet Synchronous Motor)

  • 류형민;김성준;설승기;권태석;김기수;심영석;석기룡
    • 전력전자학회논문지
    • /
    • 제6권6호
    • /
    • pp.538-545
    • /
    • 2001
  • 본 논문에서는 영구 자석형 동기 전동기를 이용한 고속 엘리베이터 시스템 용 무기어식 구동 시스템의 개발 사례를 소개한다. 엘리베이터 구동원으로서 영구 자석형 동기 전동기의 채택은 에너지 절약, 승차감 향상, 기계실의 하중 부담 감소 및 효율적인 공간 활용 등의여러 장점을 지닌다. 전력 변환 장치로는 기존의 다이오드 정류기와 제동 저항 대신 직류단 전압 제어 회생 운전 그리고 낮은 고조파 함유율이 역률 1 제어가 가능한 승압형 PWM 컴버터를 채택하였다. 제어 시스템은 고속 대용량의 단일 DSP를 사용하여 통합형 제어 시스템을 구축함으로써 전체 제어 시스템의 신뢰성 및 성능을 크게 향상시켰다. 시험 장치로는 고속 엘리베이터용 부사 시뮬레이터 시스템을 개발하여 운전 거리에 대한 제약 없이 구동 시스템의 다양한 시험이 가능해졌다.

  • PDF