• Title/Summary/Keyword: Unicell

Search Result 8, Processing Time 0.024 seconds

Experimenal Study on Unsteady Double-Diffusive Convection in a Rectangle (사각형 용기내의 비정상 이중확산유동에 관한 실험적 연구)

  • 홍남호;김창수;현명택
    • Journal of Ocean Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.105-113
    • /
    • 1994
  • Double-diffusive convection induced by simultaneously-imposed lateral temperature and concentration gradients in a rectangular enclosure with aspect retio, 2.0 has been studied experimentally for adiabatic and isothermal horizontal boundary conditions. Visual observations show two distinct flow structures depending on the buoyancy ratio. The unicell flow structure is observed for a lower buoyancy ratio while the layered flow structure appears for a higher buoyancy ratio. There exists an unstable flow regime between two buoyancy ratios.

  • PDF

Morphological variation of Scenedesmus quadricauda (Turpin) de Br bisson and Scenedesmus armatus (Chodat) G.M. Smith in culture (내실배양에 따른 Scenedesmus quadricauda(Turpin) de Br bisson과 Scenedesmus armatus(Chodat) G.M. Smith의 형태변이)

  • 안선숙
    • Journal of Plant Biology
    • /
    • v.28 no.4
    • /
    • pp.305-315
    • /
    • 1985
  • Morphological variations within the species of Scenedesmus in Korea, S. armatus and 2 strains of S. quadricauda were investigated. Taxonomic characters such as length of long spine, ridge, unicell-colony transformation, and colony types were compared. The length of long spine was constant, whereas the distribution of the spine varied with the age of culture. Ridge and short spine in S. armatus occurred constantly, whereas those in S. quadricauda varied with the composition of the media and age of culture. Strains CY-1 and CY-2 showed 6 different colony types in the stationary culture, whereas S. armatus formed only two types, armatus and armatus-longus types. All strains showed unicell-colony transformation. The cell became minimum when the daughter cell was released, and reached maximum at division.

  • PDF

Numerical Study on Double-Diffusive Convection in a Stratified Trapezoidal Enclosure (성층화된 사다리꼴 용기내에서의 이중확산유동에 관한 수치해석)

  • 현명택
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.143-150
    • /
    • 1992
  • Numerical simulation is made of a stably stratified salt-water solution due to lateral heating in an equilateral trapezoidal enclosure using boundary-fitted coordinate in grid generation. Results show four types of the global fluid pattern depending on the buoyancy ratio in the enclosure, i.e., unicell flow pattern for the low buoyancy ratio, layered flow pattern for the increasing buoyancy ratio, layered flow pattern with stagnant zone for the relatively high buoyancy ratio and stagnant flow pattern for the much higher buoyancy ratio.

  • PDF

A Study on Friction and Wear of Foam Rubbers (발포고무의 마찰 및 마모특성에 관한연구)

  • 범석훈
    • The Korean Journal of Rheology
    • /
    • v.7 no.1
    • /
    • pp.50-59
    • /
    • 1995
  • 겨울용 타이어인 '발포고무 타이어'의 트레드에 적용되는 발포고무의 물성과 마찰 및 마모특성을 조사하였다. 천연고무인 SMR-CV60과 합성고무인 BR-01(Cis-1, 4 Polybutadiene)을 70:30 비율로 혼합하였고 발포제로는 개질화된 azodicarbonamide (상품 명:UNICELL AD#2)을 변량 첨가하여 다양한 발포도의 발포고무를 준비하였다. 발포도의 증 가로 발포고무의 Young's modulus와 파괴에너지는 점진적으로 감소하였으나 Tan $\delta$ 는 일정한 값을 유지하였다. 매끄러운 유리표면위에서 높은 마찰계수를 보인 발포고무는 발포 도의 증가로 크게 감소하였고 거친 표면일수록 마찰계수는 상승하였다. 이같은 마찰계수의 증감경향이 교차되는 발포도는 30~40%이었다. $0^{\circ}C$에서의 마찰계수도 유리 표면에서감소하 고 거친표면에서 상승하는 경향을 보였으며 증감경향이 교차하는 발포도는 20%로 낮아졌 다. 마찰표면을 마그네시아 분말로 처리하면 전반적으로 마찰계수는 감소하였고 발포도의 크기에 관계없이 마찰표면이 거칠수록 큰 마찰계수를 나타내었다. 발포고무의 발포도가 커 지면 마모손실량도 비례하여 증가하였으며 발포도가 낮은 고무에서는 비교적 규칙적인 융기 간격이 보였으나 발포도가 30%이상으로 되면 불규칙적인 마모표면과 더불어 많은 마모 부 스러기가 관찰되었다.

  • PDF

Natural Convection in a Three Dimensional Inclined Enclosure (경사진 3차원 밀폐 공간 내에서의 자연대류)

  • Bae Dae Seok;Kwon Oh Boong;Kim Hyun Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.168-176
    • /
    • 2005
  • In an inclined enclosure with the upper part cooled and the lower part heated, quantitative data of the temperature and velocity are obtained simultaneously using thermo-sensitive liquid crystals. Experimental results are Presented for Pr=909. aspect ratios of 1/14. 2/14 and 3/14, angle of inclination, 0$\leq$$\theta$$\leq$45 to the horizontal line. The numerical results are obtained in the same conditions as experiments by the finite volume method and its results are compared with experimental results. It is found that the number of cell is decreased with increasing the angle of inclination. and a unicell is formed at nearby 6=30$^{circ}$ which is not affected by the aspect ratio.

Natural Convection Heat Transfer in Inclined Rectangular Enclosures (경사진 사각형 공간내의 자연대류 열전달)

  • Chang, Byong-Hoon
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.44-53
    • /
    • 2011
  • The laminar natural convection of air in 2-D rectangular enclosure in which two opposing isothermal walls were kept at different temperatures is investigated numerically for Rayleigh number up to $10^6$. Computations were performed for the width-to-height ratios of 1, 2, and 4, and for the inclination angle range of $0^{\circ}{\leq}{\theta}{\leq}90^{\circ}$. For each aspect ratio, the influence of the inclination angle on the flow patterns and heat transfer rates were examined for $10^3{\leq}Ra{\leq}10^6$. It is found that the growth of secondary flow in the corners led to the decrease in overall heat transfer for small aspect ratio case, and the transition from a three-cell structure to a unicell flow pattern in large aspect ratio led to a step-like change in heat transfer. A new correlation of mean Nusselt number is presented for the vertical case of ${\theta}=90^{\circ}$.

Finite Element Analysis of Natural Convection of Fluids with Low Prandtl Number in a Square Enclosure (유한요소법을 이용한 정방형 밀폐용기내의 플란틀수가 낮은 유체의 자연대류에 관한 연구)

  • 김무현;이진호;강신형;손영석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.541-550
    • /
    • 1988
  • Natural convection in a square enclosure was investigated numerically for low prandtl number fluids using Finite Element Method. In case of Ra=10$^{4}$, 10$^{5}$ and 10$^{6}$ the temperature gradient decreases gradually at the lower end of the hot wall(or at the upper end of the cold wall) as prandtl number decreases in the range of 0.01 .leq. Pr .leq. 10. Maximum heat transfer occurs at a somewhat higher point from the lower end of hot wall(or at somewhat lower point from the upper end of the cold wall) and it draws near to the lower end of the hot wall(or draws near to the upper end of the cold wall) with increasing prandtl number. The flow in the enclosure appears as an Unicell Pattern for Ra .leq. 10$^{4}$ and secondarily flows(or tertiary flows) appears in the core region for Ra .geq. 10$^{5}$ . The line joining the center of secondary cells skewes in a clockwise direction as the Prandtl number decreases.

Fundamental studies on thermosolutal convection in mercurous bromide(Hg2Br2) physical vapor transport processes (브로민화 수은(I)(Hg2Br2) 물리적 증착공정에서 온도농도대류의 기초연구)

  • Geug Tae Kim;Moo Hyun Kwon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.110-115
    • /
    • 2023
  • During the Hg2Br2 physical vapor transport process, with increasing the partial pressure of component B, PB from 40 Torr to 200 Torr, a unicellular convective flow structures move from the crystal growth region to the center region in the vapor phase. The boundary layer flow is dominant for PB = 40 Torr, and the core region flow is dominant for PB = 200 Torr. The flow in the vapor phase shows a three-dimensional convective flow structure with a single cell (unicellular) for PB = 40 Torr and 200 Torr, exhibits an asymmetrical flow with respect to the x, y central axis under the horizontally oriented configuration with an aspect ratio (length-to-width) of 3 and linear conducting walls. The critical temperature difference between the source and crystal region is about 30 K. The total molar flux of Hg2Br2 increases with the temperature difference until the total molar flux reaches the critical value. At the critical total molar flux, the total molar flux abruptly decreases.