• Title/Summary/Keyword: Unfilled sealant

Search Result 8, Processing Time 0.035 seconds

EFFECT OF TIME ELAPSED FROM APPLICATION TO CURING ON THE PENETRATION OF SEALANT (치면열구전색제 도포 후 광중합 할 때까지의 경과시간이 전색제 침투에 미치는 영향)

  • Choi, Sun-Ah;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.491-498
    • /
    • 2005
  • Occlusal fissures and pits are ideal places for the development of caries. Pit and fissure sealants are now considered as a very effective means to prevent dental caries. The purpose of this investigation was to examine the effect on the sealant penetration of the elapse of time from the application of sealant until exposure to visible light, and to examine the effect of the filler content and tooth position on the sealant penetration. 192 extracted human premolars were used to this experiment. Following enamel conditioning, a light-polymerized sealant was applied and 4 different periods of time(3, 5, 10, 20 seconds) were allowed until exposure to the light source. The results obtained were as follows; 1. According to time, in both unfilled sealant and filled sealant penetration increases deeply through mindfulness. 2. Sealant that apply to mandiblar premolar penetrated deeply through than to maxillay teeth. 3. Penetration difference according to filler content, unfilled sealant penetrated deeply through than filled sealant. The result from this study indicated that unfilled sealant penetrated most deeply in mandible when at least 20s time elapsed.

  • PDF

THE FISSURE PENETRATION AND MICROLEAKAGE OF PIT AND FISSURE SEALANT WITH MECHANICAL PREPARATION (기계적 삭제방법을 이용한 치면열구전색제의 열구 침투도 및 미세누출)

  • Kim, Ji-Yeon;Lee, Jae-Ho;Park, Ki-Tae;Kim, Seong-Oh;Choi, Byung-Jai;Son, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.164-173
    • /
    • 2005
  • Mechanical preparation has been introduced to provide the sealant retention. The objective of this study was to compare the fissure penetration and the microleakage of pit and fissure sealant using mechanical preparation(mechanical preparation + acid etching) and acid etching only. An additional objective of this study was to compare the fissure penetration and the microleakage of unfilled and filled sealant in both methods. Sixty human premolars extracted for orthodontic purpose were selected. Thirty teeth were acid etched alone and remaining thirty teeth were prepared with a $\frac{1}{4}$ round bur and then acid etched. One-half of teeth in each surface treatment method were sealed with unfilled sealant and the other half were sealed with filled sealant. All of the teeth were thermocycled for 1200 cycles at $5^{\circ}C\;and\;55^{\circ}C$ and immersed in 5% methylene blue for 24 hours. Each tooth was sectioned bucco-lingually at mesial pit and distal pit and examined under a Measurescope. In the case of mechanical preparation, fissure penetration of sealant was significantly increased compared with the case of acid etching only(P < 0.05). The filled and unfilled sealant using mechanical preparation showed significantly decreased microleakage when compared with the unfilled sealant using acid etching only(P < 0.05). No differences were found in fissure penetration and microleakage between unfilled and filled sealant in both methods. Taken together, the results of this study suggest that mechanical preparation and filled sealant are recommended when placing pit and fissure sealant. However, further clinical studies should be performed in regard to microleakage.

  • PDF

THE EFFECTS OF DRYING AGENTS AND BONDING AGENTS ON THE SHEAR BOND STRENGTH OF SEALANTS TO ENAMEL (치면건조제와 접착제의 사용에 따른 치면열구전색재의 전단결합강도에 관한 연구)

  • Lim, Hyun-Hwa;Jang, Ki-Taek;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.196-203
    • /
    • 2003
  • The application of sealants is a highly technique-sensitive procedure, requiring an extremely dry field prior to placement. Moisture contamination of the etched enamel surface before sealant placement is cited as the main reason for sealant failure. The purpose of this study was to evaluate the effects of different methods of sealant application on the shear bond strength of sealants to enamel. In groups 1, 2, 3, 4 Teethmate(unfilled sealant) was used, while Ultraseal XTplus(filled sealant) was used in groups 5, 6, 7, 8. Groups 1 and 5(control) were acid etched for 15 seconds using 35% phosphoric acid, washed and then dried. In groups 2, 6 drying agents were applied, and in groups 3, 7 bonding agents were applied and light cured. In groups 4 and 8 both drying agent and bonding agent were applied. Then sealant was cured to the specimen using molds 3mm in diameter and 2mm in height. Thermocycling was performed and shear bond strength was finally measured. The following results were obtained : 1. Groups using filled sealant(groups 5, 6, 7, 8) showed higher shear bond strengths compared to groups using unfilled sealant(groups 1, 2, 3, 4). 2. Among groups using unfilled sealant(groups 1, 2, 3, 4), groups 2, 3, 4 showed significantly higher shear bond strength compared to group 1(p<0.05). There were no significant differences among groups 2, 3 and 4. 3. There were no significant differences(p>0.05) among groups using filled sealant(groups 5, 6, 7, 8). 4. When modes of fracture were examined, cohesive failure was observed in groups 2, 3 and 4.

  • PDF

THE EFFECT OF FLUORIDE PRETREATMENT ON SHEAR BOND STRENGTH BETWEEN ENAMEL AND FISSURE SEALANT (불소 전처리가 법랑질과 치면열구전색재의 전단결합강도에 미치는 영향)

  • Ryu, Phil-Jun;Jang, Ki-Taek;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.522-529
    • /
    • 2001
  • This study seeks to know the effect of fluoride topical application on the shear bond strength between enamel and fissure sealant. On group 1,2,3,4, Teethmate A(unfilled sealant) and on group 5,6,7,8 Ultraseal XT(filled sealant) were used. Group 1 and 5 were not pre-treated with fluoride and group 2 and 6 were pre-treated with 1.23% APF for 4minutes. Group 3 and 7 were pretreated with 2.0% NaF for 4 minutes. and group 4 and 8 were pumiced with abrasive containing fluoride for 10 seconds. Prepared specimens were acid etched for 30 seconds using 35% phosphoric acid, and then sealant was cured to the specimen using a 3mm diameter by 2mm height mold. They went through thermocycling. Its shear bond strength was measured, and then acid etched both groups that were pretreated with fluoride and that were not pretreated with fluoride. Then we examined the surface of the specimen with EM and came up with these results. In groups using unfilled sealant(group 1,2,3.4) there were no significant differences between oops pretreated with fluoride and groups not pretreated with fluoride. In groups using filled sealant(group 5,6,7,8), groups 6 and 7(treated with 1.23% APF 2.0% NaF respectively) showed significantly lower shear bond strength, compared to group 5 (not pretreated with fluoride) and group 8 (pumiced with abrasive containing fluoride) (p<0.05).

  • PDF

Evaluation of High-power Light Emitting Diode Curing Light on Sealant Polymerization (고출력 발광 다이오드 광중합기의 치면열구전색제 중합능 평가)

  • Park, Youngjun;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.57-63
    • /
    • 2019
  • This study aimed to determine whether the curing times of Xtra Power and High Power modes of high-power light emitting diode (LED) curing light are sufficient for polymerization of resin sealants. The specimens were prepared and their microhardness values were measured and compared with those of specimens polymerized under conventional LED curing light. The filled sealant polymerized for 8 seconds in the High Power mode and for 3 seconds in the Xtra Power mode showed significantly lower microhardness than the control specimen (p = 0.000). The unfilled sealant polymerized for 8, 12 seconds in the High Power mode and for 6 seconds in the Xtra Power mode showed significantly lower microhardness than the control specimen (p = 0.000). The results of this study suggest that the short curing time with the Xtra Power and High Power modes of highpower LED curing light are not sufficient for adequate polymerization of sealants under specific conditions, taking into account the curing times and the type of sealant.

Enamel pretreatment with Er:YAG laser: effects on the microleakage of fissure sealant in fluorosed teeth

  • Memarpour, Mahtab;Kianimanesh, Nasrin;Shayeghi, Bahareh
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.180-186
    • /
    • 2014
  • Objectives: The purpose of this in vitro study was to evaluate the microleakage and penetration of fissure sealant in permanent molar teeth with fluorosis after pretreatment of the occlusal surface. Materials and Methods: A total of 120 third molars with mild dental fluorosis were randomly divided into 6 groups (n = 20). The tooth surfaces were sealed with an unfilled resin fissure sealant (FS) material. The experimental groups included: 1) phosphoric acid etching (AE) + FS (control); 2) AE + One-Step Plus (OS, Bisco) + FS; 3) bur + AE + FS; 4) bur + AE + OS + FS; 5) Er:YAG laser + AE + FS; and 6) Er:YAG laser + AE + OS + FS. After thermocycling, the teeth were immersed in 0.5% fuchsin and sectioned. Proportions of mircoleakage (PM) and unfilled area (PUA) were measured by digital microscope. Results: Overall, there were significant differences among all groups in the PM (p = 0.00). Group 3 showed the greatest PM, and was significantly different from groups 2 to 6 (p < 0.05). Group 6 showed the lowest PM. Pretreatment with Er:YAG with or without adhesive led to less PM than bur pretreatment. There were no significant differences among groups in PUA. Conclusions: Conventional acid etching provided a similar degree of occlusal seal in teeth with fluorosis compared to those pretreated with a bur or Er:YAG laser. Pretreatment of pits and fissures with Er:YAG in teeth with fluorosis may be an alternative method before fissure sealant application.

INFLUENCE OF THE ENAMEL TREATMENT WITH ER:YAG LASER ON THE MICROLEAKAGE OF PIT AND FISSURE SEALANT (Er:YAG 레이저를 이용한 법랑질 표면처리가 치면열구전색제의 미세누출에 미치는 영향)

  • Lee, Ji-Hyun;Kim, Jae-Moon;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.192-200
    • /
    • 2006
  • The aim of this study was to assess the microleakage underneath a pit and fissure sealant bonded to occlusal surfaces treated by Er:YAG laser To determine the most effective energy density of laser, fourteen specimens were irradiated from 50mJ to 300mJ at 3Hz. After irradiation, the lased specimens were observed under the scanning electron microscope. Thirty six non-carious extracted premolars were randomly assigned to four groups of nine teeth: group 1, no treatment on the occlusal surface; group 2, acid etching for 15 seconds; group 3, Er:YAG laser irradiation; group 4, acid etching followed by Er:YAG laser irradiation. The pits and fissures were sealed with unfilled sealant(Helioseal F) and the specimen teeth were thermo-cycled, immersed in 2% Rhodamine B solution, longitudinally sectioned and analyzed for microleakage with fluorescent microscope. The results were as follows: 1. Er:YAG lased surfaces with 50mJ, 3Hz showed a similar pattern of irregularity with acid etched enamel surfaces 2. The mean microleakage score increased in the order of group 2, 4, 3 and 1. There was no significant difference among group 1, 3 and 4(p>0.05), however group 2 showed significantly less microleakage compared with group 1 and 3. Conclusively, the laser irradiation seemed not enough to replace the acid etching for proper retention of pit and fissure sealants.

  • PDF

A STUDY ON MICROLEAKAGE OF PREVENTIVE RESIN RESTORATION (예방적 레진수복의 미세누출에 관한 연구)

  • Koo, Hyun-Jung;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.504-511
    • /
    • 2001
  • Preventive resin restoration, extended concept of occlusal pit and fissure sealing, is procedure composed of as follows. Cavity preparation is limited to areas of initial caries The cavity is then restored with composite resin, while other sound pits and fissures are sealed with pit and fissure sealant. If pit and assure sealant with which microrestoration is possible is used, it may be of great benefit to both patient and operator in case of difficult-to-control children s treatment. However study on preventive resin restoration using this kind of materials have been scarce. The purpose of this study was to compare the microleakage of four different modes of preventive resin restoration. Restoration using only composite resin was compared together Fifty-five bicuspids were prepared with small class I cavity preparation on the occlusal surface, divided into the following groups and restored accordingly. Group 1 : Cavity was restored with Z-100 composite resin Group 2 : Cavity was restored with Z-100 composite resin. Pits and fissures were then sealed with Teethmate F-1 Group 3 : Cavity was restored with Z-100 composite resin Pits and fissures were then sealed with Ultraseal XT-plus Group 4 : Cavity and pits and fissures were restored with Ultraseal XT-plus altogrether Group 5 : Cavity was restored with Ultraseal XT-plus. Pits and fissures were then sealed with the same material. After restoration, the samples were thermocycled 500 times between $5^{\circ}C$ and $55^{\circ}C$ with a dwell time of 30 seconds. After thermocycling, the samples were dipped into 1% methylene blue solution for 24 hours, then rinsed with tap water. The teeth were then embedded in resin and cut buccolingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage. The results were as follows : 1. Group 4 showed the greatest microleakage, while group 3, showed the least. The mean microleakage decreased in the following order:4>1>5>2>3. 2. There was no stastically significant difference between group 1 and group 5(p>0.05). However, group 1 showed significantly greater microleakage compared to group 2 and 3(p<0.05) Group 1 showed significantly less microleakage compared to group 4(p<0.05). 3. Group 2 showed no statistically significant difference compared to group 3(p>0.05). However group 2 showed significantly less microleakage compared to group 4 and 5(p<0.05) 4. Group 3 showed significantly less microleakage compared to group 4 and 5(p<0.05). 5. Group 5 showed significantly less microleakage than group 4(p<0.05).

  • PDF