• Title/Summary/Keyword: Unexpected result

Search Result 442, Processing Time 0.026 seconds

Risk Assessment for Contact Accident of Buoy - Focusing on Busan New Port - (등부표 접촉사고 발생의 위험성 평가에 관한 기초 연구 - 부산항신항 해역을 중심으로 -)

  • Lee, Myoung-ki;Park, Young-Soo;Jeong, Hae-Sang;Gug, Seung-Gi
    • Journal of Navigation and Port Research
    • /
    • v.44 no.3
    • /
    • pp.158-165
    • /
    • 2020
  • Buoys are a necessary component for the safety of vessel traffic. However, if the buoy becomes inoperable from damage and loss, it can have significant impact on vessel traffic safety as well as unexpected budget spending. The purpose of this study was to evaluate the risk of accidental contact by applying the marine traffic assessment index that can reflect the traffic flow in the sea area. First, Busan Port No. 5 fairway, with a high number of buoys and many contact accidents, was set as the sea area for assessment. to investigate the status of accidental contact and evaluate risk of contact accidents based on the IALA Waterway Risk Assessment Programme (IWRAP MkII) and Potential Assessment of Risk Model (PARK Model). As a result, buoys are near the P recautionary Area wherein the traffic flow was complicated by the Masan port vessel and Busan new port vessel, and buoys are near the entrance of the Gadeok waterway, wherein vessels show a pattern of navigation across the fairway and buoys are near the breakwater in the inner fairway were considered as high risk for contact accidents. This study can be used as basic data for establishing an integrated model to evaluate the risk of buoy contact accidents.

An Efficient Secure Routing Protocol Based on Token Escrow Tree for Wireless Ad Hoc Networks (무선 애드 혹 네트워크에서 보안성을 고려한 Token Escrow 트리 기반의 효율적인 라우팅 프로토콜)

  • Lee, Jae Sik;Kim, Sung Chun
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.4
    • /
    • pp.155-162
    • /
    • 2013
  • Routing protocol in ad hoc mobile networking has been an active research area in recent years. However, the environments of ad hoc network tend to have vulnerable points from attacks, because ad hoc mobile network is a kind of wireless network without centralized authentication or fixed network infrastructure such as base stations. Also, existing routing protocols that are effective in a wired network become inapplicable in ad hoc mobile networks. To address these issues, several secure routing protocols have been proposed: SAODV and SRPTES. Even though our protocols are intensified security of networks than existing protocols, they can not deal fluidly with frequent changing of wireless environment. Moreover, demerits in energy efficiency are detected because they concentrated only safety routing. In this paper, we propose an energy efficient secure routing protocol for various ad hoc mobile environment. First of all, we provide that the nodes distribute security information to reliable nodes for secure routing. The nodes constitute tree-structured with around nodes for token escrow, this action will protect invasion of malicious node through hiding security information. Next, we propose multi-path routing based security level for protection from dropping attack of malicious node, then networks will prevent data from unexpected packet loss. As a result, this algorithm enhances packet delivery ratio in network environment which has some malicious nodes, and a life time of entire network is extended through consuming energy evenly.

Methods of Recycling Soil Washing Wastewater for Volume Reduction (토양세척폐액 부피감소를 위한 재생방법 연구)

  • 김계남;원휘준;오원진
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.1
    • /
    • pp.17-26
    • /
    • 2003
  • The sorption experiment of cobalt was performed after the TRIGA soil was intentionally contaminated with cobalt was found that the sorption equilibrium coeficiency of soil decontamination was high when the ratio of soil mass to the volume of citric acid becomes 1:5 The TRIGA soil contaminated with 0.01 M, 0.001 M, and 0.0001 M of cobalt solution were decontaiminated with 0.01 M citric acid. The cobalt concentrtion in the wastewater were measured to be correspondingly 36.0, 14.0, 1.5 ppm. The results of wastewater recycling experiment by chemical precipitation method revealed that corresponding cobalt removal efficiency were 97% 88%. It was shown that the removal efficiency decreases as the cobalt concentration in the wastewater decreases. During the decontamination experiment, a lot of NaOH had to be added, and the volume of final solid waste reached almost 10% of that of the contaminated soil. The result of wastewater recyling experiment by ion exchange resin meted rethod revealed that to more the strong acid resins are used, the higher the cobalt removal efficiency becomes and the cobalt removal efficiency becomes and the lower the pH of recycling wastewater become. In order to obtain more than 95% removal efficiency, more than 0.625 g of strong acid resin was necessary in each of 3 experiments. There was an unexpected problem that a lot of strong acid resin waste was produced which amounts to 9.2% (volume) of the contaminated soil.

Virus-Resistance Analysis in Transgenic Tobacco Expressing Coat Protein Gene of Cucumber Mosaic Virus (오이모자이크바이러스 외피단백질유전자 발현 담배의 바이러스 저항성 분석)

  • 손성한;김경환;박종석;황덕주;한장호;이광웅;황영수
    • Korean Journal of Plant Tissue Culture
    • /
    • v.24 no.3
    • /
    • pp.153-160
    • /
    • 1997
  • Cucumber mosaic virus (CMV) leads to a cause of poor crop productivity and quality. To solve this problem, we attempted to develop a virus-resistance tobacco plants by using viral coat protein (CP) gene. Transgenic tobacco plants expressing CMV CP gene were analysed by the resistance upon CMV infection. The virus-resistance was measured in $\textrm{T}_{1}$, generation by the inhibition of plant growth and the expression of the mosaic symptoms infected with CMV. The transgenic lines were divided into four groups: highly resistant, resistant, moderate and susceptible based on their growth and symptom severity. Out of 39 transgenic lines, 16 lines showed significant virus-resistance. And of resistant lines, 2 lines were designated highly resistant based on the facts that they achieved similar plant height to that of non-infected tobacco plants and showed lower disease symptom than that of other lines. The steady state level of CP RNA and coat protein level were measured by northern blot and immunoblot analysis. The CP RNA was highly accumulated in most resistant and moderate lines but barely detected in susceptible lines. The coat protein was detected in most lines regardless of their resistance to CMV. from this result, virus-resistance appeared to correlate more with CP RNA level than the level of coat protein. However, in two highly resistant lines, CP RNA level was unexpectedly low. This unexpected phenomenon need to be further investigated.

  • PDF

An Analysis on Evacuation Scenario at Metro-stations using Pedestrian Movement-based Simulation Model (보행류 기반 도시철도역사 평가 시뮬레이터를 활용한 대피 시나리오 분석)

  • You, So-young;Jung, Rea-hyuck;Chung, Jin-hyuck
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.2
    • /
    • pp.36-49
    • /
    • 2016
  • A subway system is one of the major transportation modes at a metropolitan area. When it meets the other lines, the metro station, so-called transferring station, is usually threatened by severe pedestrian congestion and safety issue of transit users including the transportation vulnerable. Although transportation planners forecast travel demand at the beginning, it is not easy to predict pedestrian flows precisely for a long term if land use plans have dramatically changed. Due to expensive costs, structural extension of metro stations is limited. Therefore, it requires efficient and technical improvements as meeting the demand of pedestrian and physical characteristics. In this study, the core mechanism of pedestrian movement-based simulation model was introduced and evacuation scenarios were analyzed with the developed model. As a result, the multiple optimal routes for unexpected events at the solid space of the multiple stories are easily searched through the simulator and in the case of Sadang Station, travel time can be reduced by 60% when the evacuation information and intuitive design are provided.

Detection of Anti-Lua in an Unexpected Antibody Screening Test: A Case Report and Literature Review (비예기항체 선별검사에서 항-Lua의 검출: 증례보고 및 문헌고찰)

  • Song, Sae Am;Oh, Seung Hwan;Park, Tae Sung;Son, Hye Soo;Sung, Sung Kyung;Lee, Ja Young;Jun, Kyung Ran;Shin, Jeong Hwan;Kim, Hye Ran;Lee, Jeong Nyeo
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.169-172
    • /
    • 2012
  • Lutheran a antigen ($Lu^a$) is detected in 6 to 8% of Caucasians and Africans. In Korean and other Asian populations, it is very rare or nearly absent. Therefore, although $Lu^a$ has a considerable immunizing capacity, sensitization to $Lu^a$ is a rare event. Here we report on a rare case of anti-$Lu^a$ in a 70 year-old female patient with Lu (a-/b+) phenotype and review the relevant literature. Due to the paucity of $Lu^a$ positive panel cells in antibody screening and identification tests, detection of this rare antibody to $Lu^a$ antigen is not feasible. Therefore, we should keep in mind the possibility of the misleading false negative result in detection of antibody to this low incidence antigen.

A Study on the Reinforcement of Bridge Foundation in the Limestone Cavity (석회암 공동지역의 교량기초 보강에 관한 연구)

  • Lee, Sang-Chul;Ryu, Chang-Yeol;Cho, Kook-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • Irregular distributions of limestone cavity in Gang-Won province area may cause unexpected accidents from reduced serviceability or failure of structure. It is requested that an appropriate ground reinforcement method should be used to improve bearing capacity of structure, and the method should also be satisfied with environmental requirements. Among several methods used for foundation constructions in cavity area, Rod Jet Pile(RJP) method has been widely used. While the RJP method was used to improve bearing capacity for the railway bridge foundations, water pollutions of drinking water as well as fishery located adjacent to this project area were occurred. The main reason of the water pollution was cement runoff used in cement mortar during injecting material in RJP method. Laboratory tests were performed to prevent water pollution. The compaction mortar method using low movable material was selected for this project. The quality of water at a fishery adjacent to the site and the compressive strength of cores taken from the construction site were measured. Test results show that the water pollutions was minimized, and the average compressive strength of foundation material was over 5 MPa. As a result of this study, compaction mortar method can be used to ensure the bearing capacity of foundation and to prevent environment pollutions.

CHEMICAL PROPERTIES OF CORES IN DIFFERENT ENVIRONMENTS; THE ORION A, B AND λ ORIONIS CLOUDS

  • Yi, Hee-Weon;Lee, Jeong-Eun;Liu, Tie;Kim, Kee-Tae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.42.1-42.1
    • /
    • 2019
  • We observed 80 dense cores ($N(H_2)$ > $10^{22}cm^{-2}$) in the Orion molecular cloud complex which contains the Orion A (39 cores), B (26 cores), and ${\lambda}$ Orionis (15 cores) clouds. We investigate the behavior of the different molecular tracers and look for chemical variations of cores in the three clouds in order to systematically investigate the effects of stellar feedback. The most commonly detected molecular lines (with the detection rates higher than 50%) are $N_2H^+$, $HCO^+$, $H^{13}CO^+$, $C_2H$, HCN, and $H_2CO$. The detection rates of dense gas tracers, $N_2H^+$, $HCO^+$, $H^{13}CO^+$, and $C_2H$ show the lowest values in the ${\lambda}$ Orionis cloud. We find differences in the D/H ratio of $H_2CO$ and the $N_2H^+/HCO^+$ abundance ratios among the three clouds. Eight starless cores in the Orion A and B clouds exhibit high deuterium fractionations, larger than 0.10, while in the ${\lambda}$ Orionis cloud, no cores reveal the high ratio. These chemical properties could support that cores in the ${\lambda}$ Orionis cloud are affected by the photo-dissociation and external heating from the nearby H II region. An unexpected trend was found in the $[N_2H^+]/[HCO^+]$ ratio with a higher median value in the ${\lambda}$ Orionis cloud than in the Orion A/B clouds than; typically, the $[N_2H^+]/[HCO^+]$ ratio is lower in higher temperatures and lower column densities. This could be explained by a longer timescale in the prestellar stage in the ${\lambda}$ Orionis cloud, resulting in more abundant nitrogen-bearing molecules. In addition to these chemical differences, the kinematical difference was also found among the three clouds; the blue excess, which is an infall signature found in optically thick line profiles, is 0 in the ${\lambda}$ Orionis cloud while it is 0.11 and 0.16 in the Orion A and B clouds, respectively. This result could be another evidence of the negative feedback of active current star formation to the next generation of star formation.

  • PDF

A Study on the Activation Measures of Library's Online Services to Overcome COVID-19 (코로나 19 극복을 위한 도서관 온라인서비스 활성화 방안에 관한 연구)

  • Noh, Younghee;Kang, Pil Soo;Kim, Yoon-Jeong
    • Journal of Korean Library and Information Science Society
    • /
    • v.51 no.4
    • /
    • pp.185-210
    • /
    • 2020
  • The library faced an unexpected crisis of COVID-19, and as a countermeasure strategy, non-face-to-face online service has been reinforced. Therefore, this study attempted to present a plan to overcome the challenges arising from rapidly changing external environment and current crisis. To this end, data search, electronic library, library service, cultural event and open space management status of 288 public libraries serviced as an integrated site were investigated. Based on this, the meaning of online services in the post-COVID-19 era and the implication of it were examined. As a result, first, the increase in the use rate of online data search services with the spread of non-face-to-face culture, second, the expansion of the services of the electronic library, third, the diversification of non-face-to-face, online services, fourth, expansion of online cultural event services, fifth, the diversification of open space services were proposed, sixth, Introduced an artificial intelligence system for unattended loan return based on access and the Seventh, expansion of experiential cultural support services and educational contents through VR, AR and MR. It is deemed necessary for the research on the future direction of the library's non-face-to-face services to be conducted by investigating the current status of online services in various types of libraries and the types and case studies of library services in the era of COVID-19.

A Study on the application method of UPS's Battery Safety for battleship Command and Fire Control System (지휘무장통제체계용 UPS 배터리의 안전성 확보방안 연구)

  • Park, Gun-Sang;Kim, Jae-Yun;Kim, Dong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.587-596
    • /
    • 2021
  • Naval battleships have systems to perform special purposes, such as the Command and Fire Control System (CFCS). Some of the this equipment should be equipped with an Uninterruptible Power System (UPS ) to ensure operational continuity and the backup of important data, even during unexpected power outages caused by problems with the ship's power generator. Heavy combat losses can occur if the equipment cannot satisfy the function. Therefore, it is important to design a stable UPS. The battery and Battery Management System (BMS) are two of the most important factors for designing a stable UPS. A power outage will be encountered if the battery and BMS are not stable. The customer will be exposed to abnormal situations, loss of important tactical data, and inability to operate some of the CFCS. As a result, an enhanced safety system should be designed. Thus, this study implemented and verified the improved system in terms of three methods, such as comparative analysis of the batteries, improvement about leakage current of the circuit, and tests of the aggressive environmental resistance to improve the UPS for CFCS.